Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-06-15 Cont ID  
Sent By jgomez Date 2007-06-15 Time 11:10 Rev Time 0.00
Received By jgomez Date 2007-06-15 Time 11:10 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-08 Cont ID  
Sent By jgomez Date 2007-06-08 Time 16:18 Rev Time 0.00
Received By jgomez Date 2007-06-08 Time 16:18 Sent To Z
Notes
2007-06-08 16:34:30BUILDING REVIEW SECOND CHECKLIST:
 1- NOTICE OF COMMENCEMENT:
 A) NEED TO BE RECORDED.
  
 B) NEEDS TO BE COMPLETE. PROVIDE CONTRACTOR'S
 INFORMATION.
  
 2- ENGINEER OF RECORD NEEDS TO REVIEW AND APPROVE IN
 WRITING ALL PRODUCT APPROVALS AS REQUIREDBY SEC.
 106.3.3CITY AMENDMENTS TO FBC 2004.
  
 3- PLANS NEED TO BE APPROVED AND STAMPED BY THE
 HISTORICAL BOARD IN THE FIFTH FLOOR OF THIS BUILDING
 PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-11 Cont ID  
Sent By jgomez Date 2007-04-11 Time 17:26 Rev Time 0.00
Received By jgomez Date 2007-04-11 Time 12:44 Sent To PC
Notes
2007-04-11 17:45:09BUILDING REVIEW CHECKLIST:
 1- NEW ROOF: PROVIDE ROOF FRAMING PLAN SHOWING
 CALCULATED UPLIFT LOADS AND TRUSS ANCHOR SCHEDULE.
 SEC. 106.1.2 CITY AMENDMENTSTO FBC 2004.
  
 2- EXTERIOR ELEVATIONS DON'T MATCH ROOF TRUSS LAYOUT
 PLAN PROVIDED.REVISE AS REQUIRED.
  
 3- PROVIDE CLEAR FLOOR PLANSSHOWING WALLS TO BE
 REMOVED, NEW WALLS, ETC.SEC. 106.1.2 CITY AMENDMENTS
 TO FBC 2004.
  
 4- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDASTATUTE.
  
 5- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72
 FOR:
 A) SIMPSON CONNECTORS SPECIFIED ON PLANS.
 B) WINDOW MULLIONS.
 C) FRENCH DOORS AND ALL NEW EXTERIOR DOORS.
 D) STORM PANELS.NEED TO PROVIDE 2004 CODE VERSION
 PRODUCT APPROVAL. ONE SUBMITTED IS 2001 CODE VERSION.
 ***NOTE: ALSO,CLEARLY IDENTIFY SPECIFIC ANCHOR TYPE
 AND SPACING TO BE USED.
 ***ALSO, CLEARLY IDENTIFY OPENINGS TO HAVE STORM
 SHUTTERS.
  
 6- ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND
 APPROVED IN WRITING (NOT SIGNING AND SEALING) BY THE
 DESIGNER OF RECORD AS REQUIRED BY SEC. 106.3.3 CITY
 AMENDMENTS TO FBC 2004.
  
 7- ENERGY CALCULATIONS: PROVIDE CURRENT FORM 600A-2004
 R AND OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM.
  
 8- SPECIFY SIZE AND TYPE OF EGRESS WINDOW AT BEDROOM
 #3, WHICH WAS CHANGED FROM DOOR TO WINDOWTO VERIFY
 COMPLIANCE WITH SEC. R310 OF 2004 FLORIDA RESIDENTIAL
 CODE.
  
 9- SPECIFY CALCULATED DESIGN PRESSURES FOR WINDOWS AND
 DOORS TO VERIFY COMPLIANCE WITH SEC. R301 OF 2004
 FLORIDA RESIDENTIAL CODE AND COMPLIANCE WITH PRODUCT
 APPROVAL SUBMITTED.
  
 10-NEW ROOF: SPECIFY ROOF PITCH TO VERIFY IF DOUBLE
 LAYER OF UNDERLAYMENT IS REQUIRED OR NOT.
  
 11- SPECIFY ROOF SHEATHING NAILING SIZE AND SPACING AS
 REQUIRED BY SEC. R803.2.3.1 OF 2004 FLORIDA RESIDENTIAL
 CODE.
  
 12- TYPICAL WALL SECTION IS INCOMPLETE. SPECIFY DRYWALL
 AT WALLS AND CEILING. SEC. 106.1.2 CITY AMENDMENTS TO
 FBC 2004.
  
 13- DESIGNER OF RECORD TO SIGN AND DATE ALL DRAWINGS AS
 REQUIREDBY SEC. 106.3.4.3 CITY AMENDMENTS TO FBC
 2004.
  
 14- DESIGNER OF RECORD TO SPECIFY ALL DESIGN CRITERIA
 INCLUDING CODE USED, ALL WIND LOADS, ALL DEAD LOADS,
 ALL LIVE LOADS AS REQUIRED BY SEC. R301 AND TABLE
 R301.5OF 2004 FLORIDA RESIDENTIAL CODE.
  
 15- SPECIFY ATTIC ACCESS FOR NEW PITCHED ROOF AT REAR
 OF HOUSE AS REQUIRED BY SEC. R807 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-06-15 Cont ID  
Sent By btrobaug Date 2007-06-15 Time 09:53 Rev Time 0.33
Received By btrobaug Date 2007-06-15 Time 09:41 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-06-01 Cont ID  
Sent By btrobaug Date 2007-06-01 Time 15:36 Rev Time 0.50
Received By btrobaug Date 2007-06-01 Time 14:18 Sent To P
Notes
2007-06-01 15:35:52 
  
 NONCOMPLIANT
  
 THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
 IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417
 FS, RESPECTIVELY.
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-03-08 Cont ID  
Sent By btrobaug Date 2007-03-08 Time 09:23 Rev Time 1.00
Received By btrobaug Date 2007-03-08 Time 07:47 Sent To M
Notes
2007-03-08 09:23:46 
  
 DENIED/INCOMPLETE INFORMATION
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT
 SIZE AND TYPE, GROUNDING DETAILS. 215.5
  
 2} PROVIDE A PANEL SCHEDULE PER 408.4. PLEASE SEE NEW
 VERBAGE FOR 2005 NEC: "THE IDENTIFICATION SHALL INCLUDE
 SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE
 DISTINGUISHED FROM ALL OTHERS."
  
 3} IF THE MAIN DISCONNECT IS NEW,OBTAIN THE
 AVAILABLE FAULT CURRENT AT THE UTILITY
 AND CALCULATE THE SAME AT THE EQUIPMENT.
 INDICATE THE AIC RATING FOR THE
 EQUIPMENT IS EQUAL TO OR GREATER THAN
 THE AVAILABLE FAULT.PER 110.9 AND 110.10:
  
 4} REGARDING NOTE #7: WHETHER OR NOT THE EXISTING
 SERVICE CAN BE USED AS A TEMPORARY FOR CONSTRUCTION
 WOULD BE AT THE DISCRETION OF THE ELECTRICAL INSPECTOR,
 WHO WOULD MAKE THAT DETERMINATION AS A SAFETY ISSUE.
 REGARDLESS, GFI PROTECTION PER 590.6.
  
 5} 210.52(C)(3) PENINSULAR COUNTER SPACES AT LEAST ONE
 RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH PENINSULAR
 COUNTER SPACE WITH A LONG DIMENSION OF 600 MM (24 IN.)
 OR GREATER AND A SHORT DIMENSION OF 300 MM (12 IN.) OR
 GREATER. A PENINSULAR COUNTERTOP IS MEASURED FROM THE
 CONNECTING EDGE. EXCEPTION TO (5): TO COMPLY WITH THE
 CONDITIONS SPECIFIED IN (1) OR (2), RECEPTACLE OUTLETS
 SHALL BE PERMITTED TO BE MOUNTED NOT MORE THAN 300 MM
 (12 IN.) BELOW THE COUNTERTOP. RECEPTACLES MOUNTED
 BELOW A COUNTERTOP IN ACCORDANCE WITH THIS EXCEPTION
 SHALL NOT BE LOCATED WHERE THE COUNTERTOP EXTENDS MORE
 THAN 150 MM (6 IN.) BEYOND ITS SUPPORT BASE.
  
 6} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-06-11 Cont ID  
Sent By adarroug Date 2007-06-11 Time 09:22 Rev Time 0.00
Received By adarroug Date 2007-06-11 Time 09:22 Sent To E
Notes
2007-06-11 09:23:13TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-05-23 Cont ID  
Sent By adarroug Date 2007-05-23 Time 14:38 Rev Time 0.00
Received By adarroug Date 2007-05-23 Time 14:38 Sent To E
Notes
2007-05-23 14:39:14TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-04-11 Cont ID  
Sent By jgomez Date 2007-04-11 Time 17:45 Rev Time 0.00
Received By jgomez Date 2007-04-11 Time 17:45 Sent To  
Notes
2007-02-23 11:38:30TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-06-14 Cont ID  
Sent By tgordon Date 2007-06-14 Time 11:42 Rev Time 0.30
Received By tgordon Date 2007-06-14 Time 11:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-03-09 Cont ID  
Sent By mperson Date 2007-06-14 Time 10:59 Rev Time 0.35
Received By tgordon Date 2007-03-09 Time 14:26 Sent To P
Notes
2007-03-09 14:34:05*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON FORM600A-04-R,
 SEE 2004 FBC 13-600.3.A (12-8-06 REVISION).
  
 2) WHEN RE-SUBMITTING THE NEW ENERGY CALCULATIONS BE
 SURE THEIR SIGNED BY OWNER/AGENT ALSO, PER 2004 FBC
 13-600.3.ABC.2.
  
 3) PLEASE HAVE MECHANICAL PLANS SIGNED ALSO.ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN. PER FBC 104.2.1 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-06-15 Cont ID  
Sent By mperson Date 2007-06-15 Time 09:58 Rev Time 0.33
Received By mperson Date 2007-06-15 Time 09:58 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-06-14 Cont ID  
Sent By mperson Date 2007-06-14 Time 10:56 Rev Time 0.33
Received By mperson Date 2007-06-14 Time 10:56 Sent To M
Notes
2007-06-14 11:08:34DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTION IS REQUIRED FOR PLUMBING PLAN
 REVIEW TO MEET CODE COMPLIANCE:
  
 1. REVISED SHEET 6:
 FBC-2004 CHAPTER 1,SECTION 106.3.4.3:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME, AND ALSO DATE DRAWING. IF AN ARCHITECT OR
 ENGINEER, COMPLY WITH 418 AND 417 FS, RESPECTIVELY.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS REVIEWER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-03-12 Cont ID  
Sent By mperson Date 2007-03-12 Time 13:09 Rev Time 0.45
Received By mperson Date 2007-03-12 Time 13:09 Sent To B
Notes
2007-03-12 14:12:49DENIED
 REFERENCE: FBC-2004 PLUMBING; FBC-2004 CHAPTER 1, CITY
 OF WEST PALM BEACH AMENDMENTS;
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING
 PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. PER FBC-2004 CHAPTER 1, SECTION 106.1.1 INFORMATION
 ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE
 BUILDING OFFICIAL.
  
 2. SHEET PG.2, SANITARY ISOMETRIC RISER DIAGRAM: PER
 FBC-2004 CHAPTER 1, SECTION 106.3.5.4 RESIDENTIAL (ONE
 AND TWO-FAMILY) PLEASE SUBMIT A PLUMBING SANITARY
 ISOMETRIC RISER DIAGRAM INDICATING ALL WASTE, VENTS,
 TRAPS AND SIZES WITH CLEANOUT LOCATIONS.
 NOTE: THE SUBMITTED DRAWING IS NOT AN ISOMETRIC, IS NOT
 CODE COMPLIANT, AND DOES NOT REFLECT THE FLOOR PLAN.
 PLEASE REFERENCE THE ATTACHED CORRECTED SANITARY
 ISOMETRIC RISER DIAGRAM TO THE PLUMBING COMMENTS FOR
 THE RESUBMITTAL.
  
 3. SHEET PG. 2, SANITARY ISOMETRIC RISER DIAGRAM: PER
 FBC-2004 PLUMBING, SECTION 1002.1 A FIXTURE SHALL NOT
 BE DOUBLE TRAPPED. A WATER CLOSET HAS AN INTEGRAL TRAP
 AND A TRAP NEED NOT BE INDICATED.
  
 4. SHEET PG. 2, SANITARY ISOMETRIC RISER DIAGRAM: PER
 FBC-2004 PLUMBING, SECTION 1002.1 EACH PLUMBING FIXTURE
 SHALL BE SEPERATELY TRAPPED BY A WATER SEAL TRAP.
 NOTE: TRAP REQUIRED FOR TUB.
  
 5. SHEET PG.2, SANITARY ISOMETRIC RISER DIAGRAM:
 (A) 708.3.5 BUILDING DRAIN AND BUILDING
 SEWER JUNCTION. THERE SHALL BE A
 CLEANOUT NEAR THE JUNCTION OF THE
 BUILDING DRAIN AND THE BUILDING SEWER.
 NOTE: PLEASE INDICATE THS CLEANOUT AS A TWO-WAY
 CLEANOUT.
  
 (B) 708.7 MINIMUM SIZE. CLEANOUTS SHALL
 BE THE SAME NOMINAL SIZE AS THE PIPE
 THEY SERVE UP TO 4 INCHES (102MM).
 NOTE: FULL SIZE CLEANOUT (3") REQUIRED FOR WASHING
 MACHINE.
  
 (C) 708.9 ACCESS. ACCESS SHALL BE
 PROVIDED TO ALL CLEANOUTS.
 NOTE: CLEANOUT FOR WASHING MACHINE SHALL BE LOCATED
 FOUR FEET ABOVE FINNISH FLOOR (4' A.F.F.)
  
 6. SHEET PG. 2, SANITARY ISOMETRIC RISER DIAGRAM: PER
 FBC-2004 PLUMBING, SECTION 406.3 STANDPIPE REQUIRED FOR
 WASHING MACHINE. PLEASE INDICATE ON THE RESUBMITTAL.
  
 ********IMPORTANT INFORMATION
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 2 Status P Date 2007-06-11 Cont ID  
Sent By choops Date 2007-06-11 Time 09:15 Rev Time 0.00
Received By choops Date 2007-06-11 Time 09:15 Sent To I
Notes
2007-06-11 09:16:31PROVISO:PROPOSED A/C UNIT TO BE A MINIMUM OF 6.172
 FT. AWAY FROM REAR PROPERTY LINE.
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720

Review Stop Z ZONING
Rev No 1 Status N Date 2007-04-11 Cont ID  
Sent By jgomez Date 2007-04-11 Time 17:23 Rev Time 0.00
Received By jgomez Date 2007-04-11 Time 17:23 Sent To  
Notes
2007-04-11 17:26:31INTERIOR REMODELING.