Plan Review Details - Permit 07020607
Plan Review Stops For Permit 07020607
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-10-04 Cont ID  
Sent By rmcdouga Date 2007-10-04 Time 07:29 Rev Time 0.00
Received By rmcdouga Date 2007-10-03 Time 18:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-07-10 Cont ID  
Sent By rmcdouga Date 2007-07-10 Time 17:59 Rev Time 0.00
Received By rmcdouga Date 2007-07-10 Time 16:58 Sent To  
Notes
2007-07-10 17:59:26DENIED BY BUILDING
  
 1) THE NOC HAS EXPIRED AND WILL NEED TO BE RE-RECORDED
 BEFORE THE PERMIT IS ISSUED.
  
 2) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE POMA
 CORP. STORM PANELS IS FOR 0.063" ALUMINUM PANELS (NOA
 02-0417.06) AND THE PLANS SPECIFY POMA CORP. 0.050"
 PANELS WITH NO FL# OR NOA # INDICATED. PLEASE CORRECT.
  
  
 3) SPECIFY THE FASTENER TYPE AND SPACING, THE MOUNT
 TYPE AND THE EDGE DISTANCE FOR THE POMA STORM PANELS.
 SINCE THERE IS ONLY ONE OPENING THAT IS BEING SHUTTERED
 THESE ITEMS CAN BE CIRCLED ON THE NOA RATHER THAN
 SUBMITTING AN INSTALLATION SCHEDULE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-06 Cont ID  
Sent By rmcdouga Date 2007-04-06 Time 14:27 Rev Time 0.00
Received By rmcdouga Date 2007-04-06 Time 14:27 Sent To Z
Notes
2007-04-06 15:01:45DENIED BY BUILDING
  
 1) THE FIRM NUMBER FOR COVENANT ARCHITECTURE AND
 CONSTRUCTION LLC IS REQUIRED TO BE LISTED IN THE TITLE
 BLOCK. SEE FS 481 AND FAC 61G1-16.004
  
 2) SUBMIT PRODUCT APPROVALS FOR THE WOOD CONNECTORS AND
 STRAPS SPECIFIED ON THE PLANS AS REQUIRED BY DCA RULE
 9B-72.
  
 3)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE A STATE FL#, A
 CURRENT MIAMI-DADE NOA IS ACCEPTABLE.
  
 4)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 5) SPECIFY THE FASTENER TYPE AND SPACING, THE MOUNT
 TYPE AND THE EDGE DISTANCE FOR THE POMA STORM PANELS.
 SINCE THERE IS ONLY ONE OPENING THAT IS BEING SHUTTERED
 THESE ITEMS CAN BE CIRCLED ON THE NOA RATHER THAN
 SUBMITTING AN INSTALLATION SCHEDULE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-09-24 Cont ID  
Sent By btrobaug Date 2007-09-24 Time 08:05 Rev Time 0.00
Received By btrobaug Date 2007-09-24 Time 07:51 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-06-25 Cont ID  
Sent By btrobaug Date 2007-06-25 Time 17:14 Rev Time 0.00
Received By btrobaug Date 2007-06-25 Time 16:10 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-03-02 Cont ID  
Sent By btrobaug Date 2007-03-02 Time 12:52 Rev Time 0.50
Received By btrobaug Date 2007-03-02 Time 12:48 Sent To P
Notes
2007-03-02 12:51:40 
 NONCOMPLIANT
  
 ELECTRICAL PLANS AND PERMIT ARE REQUIRED FOR THE SCOPE
 OF WORK. 105.1 FBC.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-09-14 Cont ID  
Sent By adarroug Date 2007-09-14 Time 15:25 Rev Time 0.00
Received By adarroug Date 2007-09-14 Time 15:25 Sent To E
Notes
2007-09-14 15:25:55TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-06-24 Cont ID  
Sent By adarroug Date 2007-06-24 Time 16:39 Rev Time 0.00
Received By adarroug Date 2007-06-24 Time 16:39 Sent To E
Notes
2007-06-24 16:39:32TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-04-06 Cont ID  
Sent By rmcdouga Date 2007-04-06 Time 14:27 Rev Time 0.00
Received By rmcdouga Date 2007-04-06 Time 14:27 Sent To  
Notes
2007-02-26 08:27:11TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-03-14 Cont ID  
Sent By tgordon Date 2007-03-14 Time 08:34 Rev Time 0.15
Received By tgordon Date 2007-03-14 Time 08:34 Sent To B
Notes
2007-03-14 08:35:28NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-09-28 Cont ID  
Sent By mperson Date 2007-09-28 Time 16:46 Rev Time 0.00
Received By mperson Date 2007-09-28 Time 16:46 Sent To B
Notes
2007-09-28 16:49:07******PROVISO******
 PER FBC-2004 PLUMBING, SECTION 704.5
 DEAD ENDS: IN THE INSTALLATION OR
 REMOVAL OF ANY PART OF A DRAINAGE
 SYSTEM, DEAD ENDS SHALL BE PROHIBITED.
 A PLUMBING PERMIT REQUIRED AND
 INSPECTION REQUIRED OF DEMO WORK PRIOR
 TO COVERING DEMO WORK WITH FINNISH
 WALLS, CIELINGS, OR POURED CONCRETE
 SLABS.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-07-03 Cont ID  
Sent By mperson Date 2007-07-03 Time 09:50 Rev Time 0.33
Received By mperson Date 2007-07-03 Time 09:50 Sent To B
Notes
2007-07-03 10:05:48DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL
 IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS,
 SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING
 REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT
 MADE ON PREVIOUS REVIEWS.
  
 ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM
 PREVIOUS REVIEW WITH A NO, OK OR A NO/OK.
 THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE
 PREVIOUS REVIEW NOTES.
  
 A **NO** IS IF THE COMMENT WAS NOT FULLY ADDRESSED
 AND/OR FURTHER EXPLANATION OR CHANGES IN PLANS OR
 DOCUMENTS ARE STILL NEEDED. THIS REVIEWER WILL TRY TO
 BETTER EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT.
  
 AN **OK** WILL BE LABELED AS SUCH ON THE SAME NUMERICAL
 COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS.
  
 A **NO/OK** MEANS PART OF THE COMMENT MAY HAVE BEEN
 ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW
 COMMENT MAY HAVE BEEN FULLY ADDRESSED.
  
 ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF
 THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH.
  
 1. **NO/OK** 1 AUTOMATIC CLOTHES WASHER CONNECTION PER
 20 DWELLING UNITS REQUIRED PER TABLE 403.1, MINIMUM
 NUMBER OF REQUIRED PLUMBING FIXTURES. PLEASE INDICATE
 THIS CONNECTION ON THE RESUBMITTAL.
  
 NOTE: SHEET 2: IS INDICATING A NEW WASHING MACHINE
 BEING LOCATED OUTSIDE. SHEET 3: IS INDICATING A 2" PVC
 TO EXISTING SANITARY, PLEASE KNOW THAT THIS IS SIZED
 WRONG AND THE FOLLOWING INFORMATION IS REQUIRED FOR THE
 WASHING MACHINE ON THE NEXT RESUBMITTAL.
  
 A} PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4
 RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A
 PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING
 THE WASTE, VENT, TRAP AND SIZES WITH CLEANOUT LOCATIONS
 OF THE NEW WASHING MACHINE.
 B} 406.3 WASTE CONNECTIONS.THE TRAP AND FIXTURE DRAIN
 FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.
 C} 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY
 TRAPPED. STANDPIPES SHALL
 EXTEND A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM)
 ABOVE THE TRAP WEIR. ACCESS SHALL BE
 PROVIDED TO ALL STANDPIPES AND DRAINS
 FOR RODDING. PLEASE INDICATE THE WASHING MACHINE
 STANDPIPE ON THE RESUBMITTAL.
 D} 708.7 MINIMUM SIZE. CLEANOUTS SHALL
 BE THE SAME NOMINAL SIZE AS THE PIPE
 THEY SERVE UP TO 4 INCHES (102MM). THE CLEANOUT FOR THE
 WASHING MACHINE SHALL BE THREE INCH (3") PLEASE
 INDICATE THIS ON THE RESUBMITTAL.
 E} 708.9 ACCESS. ACCESS SHALL BE
 PROVIDED TO ALL CLEANOUTS. PLEASE INDICATE THE CLEANOUT
 FOR THE WASHING MACHINE AT FOUR FEET ABOVE FINNISH
 FLOOR (4' A.F.F.) ON THE RESUBMITTAL.
  
 2. **OK**
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-03-12 Cont ID  
Sent By mperson Date 2007-03-12 Time 11:31 Rev Time 0.45
Received By mperson Date 2007-03-12 Time 11:31 Sent To M
Notes
2007-03-12 11:42:36DENIED
 REFERENCE: PBC-2004 PLUMBING; FLORIDA ADMINISTRATIVE
 CODE;
  
 THE FOLLOWING CORRECTION ARE REQUIRED FOR PLUMBING PLAN
 REVIEW TO MEET CODE COMPLIANCE:
  
 1. 1 AUTOMATIC CLOTHES WASHER CONNECTION PER 20
 DWELLING UNITS REQUIRED PER TABLE 403.1, MINIMUM NUMBER
 OF REQUIRED PLUMBING FIXTURES. PLEASE INDICATE THIS
 CONNECTION ON THE RESUBMITTAL.
  
 2. FAC-61G1-16.004 TITLE BLOCK:
 A TITLE BLOCK MUST APPEAR ON ALL
 ARCHITECTURAL OR INTERIOR DESIGN
 DRAWINGS AND SPECIFICATION
 IDENTIFICATION SHEETS. THE TITLE BLOCK
 MUST, AT A MINIMUM, CONTAIN THE
 FOLLOWING INFORMATION:
 (1) FIRM NAME, ADDRESS, AND TELEPHONE
 NUMBER.
 (2) FIRM LICENSE NUMBER.
 (3) NAME OR IDENTIFICATION OF PROJECT.
 (4) DATE PREPARED.
 (5) A SPACE FOR THE SIGNATURE AND DATED
 SEAL.
 (6) A SPACE FOR THE PRINTED NAME OF THE
 PERSON SEALING THE DOCUMENT.
 NOTE: FIRM LICENSE NUMBER MISSING ON TITLE BLOCK,
 PLEASE CORRECT AND RESUBMIT.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 1 Status N Date 2007-04-11 Cont ID  
Sent By adavila Date 2007-04-11 Time 15:33 Rev Time 0.00
Received By adavila Date 2007-04-11 Time 15:18 Sent To  
Notes
2007-04-11 15:26:13PLANNING AND ZONING DEPARTMENT
  
 ***NO REVIEW REQUIRED***
  
 1.PLEASE NOTE THAT PHASE II IS SUBJECT TO
 ADDITIONALLY REVIEW.
  
 2.PLEASE NOTE THAT PURSUANT TO SECTION 94-35(D)(5) OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS, ATTACHED
 OR DETACHED ADDITIONS OF 1,000 OR MORE GROSS SQUARE
 FEET TO AN EXISTING RESIDENTIAL STRUCTURE IS SUBJECT TO
 AN INFORMAL SITE PLAN REVIEW (LEVEL I).
  
 3.PLEASE NOTE THAT PURSUANT TO SECTION 94-76(A)(1) OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS, ONLY FOUR
 (4) DWELLING UNITS ARE PERMITTED ON THIS SITE.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.