Plan Review Details - Permit 07020603
Plan Review Stops For Permit 07020603
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-04-07 Cont ID  
Sent By shill Date 2007-04-07 Time 13:56 Rev Time 0.00
Received By shill Date 2007-04-07 Time 13:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-03-23 Cont ID  
Sent By shill Date 2007-03-23 Time 16:35 Rev Time 0.00
Received By shill Date 2007-03-23 Time 16:35 Sent To  
Notes
2007-03-23 16:45:27****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY
 OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
  
 _XX_9.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-09 Cont ID  
Sent By shill Date 2007-03-07 Time 16:33 Rev Time 0.00
Received By shill Date 2007-03-07 Time 16:33 Sent To  
Notes
2007-03-09 11:50:13****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.NO CONNECTION TYPE WAS PROVIDED, AND
 ON THE PRODUCT APPROVAL ALL CONNECTION TYPES ARE
 CIRCLED.IF YOU ARE USING MULTIPLE INSTALLATION
 CONDITIONS, INDICATE WHICH CONNECTION GOES WITH WHICH
 OPENING.IF YOU DESIGN TO "WORST CASE", YOU MAY CIRCLE
 ONE.PLEASE CONTACT ME IF YOU NEED ASSISTANCE IN
 DETERMINING HOW TO SHOW CODE COMPLIANCE.
  
 ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4
 ABOVE.
  
 _XX_9.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-04-03 Cont ID  
Sent By spalmer Date 2007-04-03 Time 18:15 Rev Time 0.00
Received By spalmer Date 2007-04-03 Time 18:15 Sent To B
Notes
2007-04-03 18:15:20TO SAMANTHA HILL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-22 Cont ID  
Sent By adarroug Date 2007-03-22 Time 10:02 Rev Time 0.00
Received By adarroug Date 2007-03-22 Time 10:02 Sent To B
Notes
2007-03-22 10:02:58TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-09 Cont ID  
Sent By shill Date 2007-03-09 Time 11:50 Rev Time 0.00
Received By shill Date 2007-02-23 Time 11:42 Sent To  
Notes
2007-02-23 11:42:55TO "MISC" BOX#1