Plan Review Stops For Permit 07020516 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-06-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-13 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-13 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-04-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-04-10 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-04-10 |
Time |
10:57 |
Sent To |
|
|
Notes |
2007-04-10 11:06:43 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | FROM PREVIOUS LIST: | | | | 1.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED | | FOR THE ROOF PANELS, FAC9B72. | | THE ELITE PANEL ENGINEERING IS IN THE PACKAGE. | | MIAMIDADE NOA WAS SUBMITTED FOR DYPLAST PRODUCTS.IF | | YOU ARE USING ELITE PANELS, PRODUCT APPROVALS REQUIRED | | FAC9B72.IF YOU ARE USING DYPLAST PRODUCTS, REMOVE THE | | ELITE PANEL ENGINEERING. | | | | 2.)PLEASE MARK DETAILS AND CONNECTIONS SPECIFIC TO | | THIS JOB.PLEASE USE INK RATHER THAN A HIGHLIGHTER. | | | | 2ND REVIEW, ALSO MARK THE PRODUCT APPROVAL.THERE ARE | | SEVERAL OPTIONS REGARDING PANEL SIZE; SPAN COMPLIANCE | | CANNOT BE DETERMINED WITHOUT COMPLETE INFORMATION. | | FBC*106.AS REQUESTED, MARK DETAILS AND CONNECTIONS | | SPECIFIC TO THIS JOB. | | | | 3.)ADDRESSED. | | | | 4.)ADDITIONAL FEES DUE (RADON), SEE ATTACHED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-03-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-24 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-03-24 |
Time |
08:38 |
Sent To |
|
|
Notes |
2007-03-24 08:40:11 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FACFLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED | | FOR THE ROOF PANELS, FAC9B72. | | | | 2.)PLEASE MARK DETAILS AND CONNECTIONS SPECIFIC TO | | THIS JOB.PLEASE USE INK RATHER THAN A HIGHLIGHTER. | | | | 3.)REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), FBC | | R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE C | | HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | R301.2.1.4. | | | | 4.)ADDITIONAL FEES DUE (RADON), SEE ATTACHED. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-06-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-06 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-06 |
Time |
10:57 |
Sent To |
B |
|
Notes |
2007-06-06 10:57:16 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-05-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-15 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-15 |
Time |
11:48 |
Sent To |
B |
|
Notes |
2007-05-15 11:48:47 | TO "SHILL' DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-04-03 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-04-03 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-04-03 |
Time |
17:41 |
Sent To |
B |
|
Notes |
2007-04-03 17:41:35 | TO SAMANTHA HILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-02-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-26 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-26 |
Time |
16:20 |
Sent To |
B |
|
Notes |
2007-02-26 16:20:27 | TO "MISC" BOX#2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-03-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-24 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-02-22 |
Time |
18:30 |
Sent To |
|
|
Notes |
2007-02-22 18:31:07 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2007-02-25 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-02-25 |
Time |
19:38 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-02-25 |
Time |
19:38 |
Sent To |
I |
|
Notes |
2007-02-25 19:40:05 | ***PROVISO*** | | | | 1) SCREEN ENCLOSURE SHALL BE A MINIMUM OF THREE (3) | | FEET FROM THE REAR PROPERTY LINE AND THREE (3) FEET | | FROM THE NON-ZERO SIDE PROPERTY LINE. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. |
|
|