Plan Review Details - Permit 07020477
Plan Review Stops For Permit 07020477
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-04-18 Cont ID  
Sent By shill Date 2007-04-18 Time 16:32 Rev Time 0.00
Received By shill Date 2007-04-18 Time 16:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-07 Cont ID  
Sent By shill Date 2007-03-07 Time 13:20 Rev Time 0.00
Received By shill Date 2007-03-07 Time 13:20 Sent To  
Notes
2007-03-07 13:21:15****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY
 AN ENGINEER. DOCUMENTS PREPARED BY AN ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 ____4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.
  
 ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4
 ABOVE.
  
 _XX_9.PROVIDE INFORMATION IN REGARDS TO THE
 BUILDING LOCATION AND REVISE EXPOSURE CATEGORY
 FBC1609.6.2.1(2), FBC R301.2.1.4 IF NECESSARY
 (CURRENTLY EXPOSURE B ON THE PLAN, APPEARS FROM AERIALS
 TO BE EXPOSURE C).NOTE THAT THE DEFINITION FOR
 EXPOSURE C HAS CHANGED EFFECTIVE DECEMBER 8, 2006
 FBC1609.4, FBC R301.2.1.4.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-04-04 Cont ID  
Sent By spalmer Date 2007-04-04 Time 17:40 Rev Time 0.00
Received By spalmer Date 2007-04-04 Time 17:40 Sent To B
Notes
2007-04-04 17:40:45TO SAMANTHA HILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-07 Cont ID  
Sent By shill Date 2007-03-07 Time 13:21 Rev Time 0.00
Received By shill Date 2007-02-20 Time 18:30 Sent To  
Notes
2007-02-20 18:30:34TO "MISC" BOX#1