Plan Review Details - Permit 07020453
Plan Review Stops For Permit 07020453
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-11-27 Cont ID  
Sent By shill Date 2007-11-27 Time 13:14 Rev Time 0.00
Received By shill Date 2007-11-27 Time 13:14 Sent To  
Notes
2007-11-27 13:14:40REVISON (DIFFERENT NOAS FOR DOORS)

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-09-11 Cont ID  
Sent By lmartine Date 2007-09-11 Time 07:31 Rev Time 0.00
Received By lmartine Date 2007-09-11 Time 07:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-11 Cont ID  
Sent By shill Date 2007-06-11 Time 13:22 Rev Time 0.00
Received By shill Date 2007-06-11 Time 13:22 Sent To  
Notes
2007-06-11 13:47:28****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 FROM PREVIOUS LIST:
  
 1.)BUILDING INFORMATION, ITEM 3, CONSTRUCTION TYPE
 SHOULD INCLUDE A OR B, FBC 6, NOT "PROTECTED".
  
 2ND REVIEW, NOW STATES "UNPROTECTED".INCLUDE A OR B.
  
  
 2-7.)ADDRESSED.
  
 8.)THE APPLICAITON STATES THAT YOU ARE "REMOVING REAR
 WINDOWS AND BLOCKING THEM UP."SHOW THIS ON THE PLAN,
 PROVIDE A DETAIL.REQUIRED FIRE RESISTANCE IS TO BE
 MAINTAINED; ALL REQUIREMENTS ARE TO BE SHOWN ON THE
 PLAN AND DETAILS ARE TO BE EITHER A TESTED ASSEMBLY OR
 CALCULATED FIRE RESISTANCE FBC9.
  
 2ND REVIEW - PROVIDE A DETAIL FOR INFILL AS REQUESTED.
  
  
 9.)THE PLAN STATES THAT YOU ARE ADDING ONE REAR DOOR.
 PROVIDE A PRODUCT APPROVAL FOR THE DOOR.PROVIDE A
 DETAIL.
  
 2ND REVIEW - PROVIDE A DETAIL AS REQUESTED.IS THE
 STOREFRONT GOING TO BE USED IN THIS LOCATION?
  
 10.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED
 IN ADDITION TO THE NOA SUBMITTED, FAC9B72.
 WWW.FLORIDABUILDING.ORG
  
 2ND REVIEW - NOT ADDRESSED.
  
 11.)PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER
 OF RECORD, FBC*106.3.3.
  
 2ND REVIEW - NOT ADDRESSED.
  
 12.)A1 NOTES THAT BAHAMA SHUTTERS ARE TO BE INSTALLED
 ON EACH NEW DOOR AND WINDOW.HOW FAR INTO THE PATH OF
 TRAVEL WILL THIS SHUTTER EXTEND?SHOW THE LINE OF THE
 BAHAMA SHUTTER AND SIDEWALK ON THE SITE PLAN.SHOW THE
 SHUTTERS ON THE ELEVATIONS.
  
 2ND REVIEW - SHOW THE HEIGHT OF THE BOTTOM OF THE
 BAHAMA SHUTTER.SEE FBC11-4.4.
  
 13.)THE WINDOW NOTES STATE THAT -176 PSF IS REQUIRED
 FOR THE STOREFRONT, ELEVATIONS REQUIRE -36.4.WHERE
 THERE IS A CONFLICT, THE MOST STRINGENT WILL APPLY. THE
 PRODUCT APPROVAL SUBMITTED ARE NOT COMPLIANT WITH THIS
 DESIGN PRESSURE REQUIREMENT (-176PSF).
  
 14.)SEE ITEM 8 ABOVE.
  
 15.)THE NEW SOUTH ELEVATION SHOWS NEW FIXED GLASS AND
 A RECTANGLE AROUND THE WINDOW.WHAT IS THIS?THE
 OPENING APPEARS LARGER.PROVIDE DETAILS AND CLARIFY
 SCOPE OF WORK.
  
 2ND REVIEW - WHAT ARE THE RECTANGLES?THERE IS AN
 UNIDENTIFIED RECTANGULAR SHAPE AROUND ONE WINDOW IN 3RD
 STREET ELEVATION, A LARGE RECTANGLE AND SMALLER
 RECTANGLE AROUND A WINDOW (OR IS THIS A DOOR?) ON
 EXISTING SOUTH ELEVATION.ALSO NOTE THAT THIS
 ELEVATION IS LABELED 3RD STREET AND ALSO LABELED SOUTH,
 SHOULD BE CONSISTENT WITH LABELING.
  
 NEW COMMENTS:
  
 16.)THE PARKING SPACES ARE TO BE LOCATED ON AN
 ACCESSIBLE ROUT NO LESS THAN 44" WIDE, FBC11-4.6(1).
  
 17.)PROVIDE AN ACCESSIBLE PARKING SPACE DETAIL.
  
 18.)SIGNAGE REQUIRED IN COMPLIANCE WITH FBC11-4.6.4.
  
 19.)WHAT ARE THE VARIOUS GRAPHICS ALONG THE BUILDING
 ENTRY?IT IS NOT CLEAR IF THE DOORS MEET MANEUVERING
 CLEARANCE REQUIREMENTS OF FBC11-4.13.6.
  
 20.)UNIT F, UNIT G ENTRIES ARE NOT ON AN ACCESSIBLE
 ROUTE.SEE FBC11-4.14.1.
  
 21.)PROVIDE A DETAIL FOR THE STAIRS AND STAIR RAIL
 FOR THE PROPOSED SITTING AREA, FBC11-4.9.
  
 22.)VERTICAL ACCESSIBILITY REQUIRED TO THE PROPOSED
 SITTING AREA, FBC11-4.1.2(2).
  
 23.)SHOW STOOP HEIGHT AT UNIT ENTRANCES, SHOWN ON
 ELEVATIONS, FBC11-4.3.8.
  
 24.)SCOPE OF WORK, C1 STATES THAT NO STRUCTURAL WORK
 IS TO BE DONE.CLARIFY THE PURPOSE OF THIS INCORRECT
 STATEMENT ON THE PLAN.
  
 25.)SEE ATTACHED FS553.80(2)(B).A 4X PLAN REVIEW
 FEE WILL BE CHARGED IF COMMENTS ARE NOT PROPERLY
 ADDRESSED A THIRD TIME.A SET HAS BEEN RETAINED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-20 Cont ID  
Sent By shill Date 2007-03-20 Time 11:17 Rev Time 0.00
Received By shill Date 2007-03-20 Time 11:17 Sent To Z
Notes
2007-03-20 11:30:10****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FACFLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)BUILDING INFORMATION, ITEM 3, CONSTRUCTION TYPE
 SHOULD INCLUDE A OR B, FBC 6, NOT "PROTECTED".
  
 2.)BUILDING INFORMATION, ITEM 3, STATES THAT THIS IS
 "PROTECTED".INCLUDE FIRE RESISTANCE RATING
 REQUIREMENTS.
  
 3.)BUILDING INFORMATION, ITEM 5, STATES THAT THIS IS
 A 2 STORY EXISTING, BUILDING, THE SITE PLAN SHOWS A 1
 STORY BUILDING.
  
 4.)DECLARE BUILDING HEIGHT.
  
 5.)ITEM 9 E STATES SEE WINDOW & DOOR SCHEDULE; NO
 SCHEDULE WAS INCLUDED.THE DESIGN PRESSURES ARE
 DECLARED IN TWO DIFFERENT PLACES, NEITHER OF WHICH IS A
 WINDOW/DOOR SCHEDULE.
  
 6.)THE WINDOW WALL SYSTEM NOTES STATES "THE BOD IS
 BASED ON . . . "WHAT IS BOD?
  
 7.)ASTM C936-82, SOLID CONCRETE INTERLOCKING PAVING
 UNITS, IS IN THE PACKAGE.THE PURPOSE OF THIS IS NOT
 CLEAR.THIS IS AN OUTDATED STANDARD, 15 YEARS OLD. C1,
 SOMEONE HAS WRITTEN THAT PAVING IS NOT IN THIS
 CONTRACT.
  
 8.)THE APPLICAITON STATES THAT YOU ARE "REMOVING REAR
 WINDOWS AND BLOCKING THEM UP."SHOW THIS ON THE PLAN,
 PROVIDE A DETAIL.REQUIRED FIRE RESISTANCE IS TO BE
 MAINTAINED; ALL REQUIREMENTS ARE TO BE SHOWN ON THE
 PLAN AND DETAILS ARE TO BE EITHER A TESTED ASSEMBLY OR
 CALCULATED FIRE RESISTANCE FBC9.
  
 9.)THE PLAN STATES THAT YOU ARE ADDING ONE REAR DOOR.
 PROVIDE A PRODUCT APPROVAL FOR THE DOOR.PROVIDE A
 DETAIL.
  
 10.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED
 IN ADDITION TO THE NOA SUBMITTED, FAC9B72.
 WWW.FLORIDABUILDING.ORG
  
 11.)PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER
 OF RECORD, FBC*106.3.3.
  
 12.)A1 NOTES THAT BAHAMA SHUTTERS ARE TO BE INSTALLED
 ON EACH NEW DOOR AND WINDOW.HOW FAR INTO THE PATH OF
 TRAVEL WILL THIS SHUTTER EXTEND?SHOW THE LINE OF THE
 BAHAMA SHUTTER AND SIDEWALK ON THE SITE PLAN.SHOW THE
 SHUTTERS ON THE ELEVATIONS.
  
 13.)THE WINDOW NOTES STATE THAT -176 PSF IS REQUIRED
 FOR THE STOREFRONT, ELEVATIONS REQUIRE -36.4.WHERE
 THERE IS A CONFLICT, THE MOST STRINGENT WILL APPLY.
 THE PRODUCT APPROVAL SUBMITTED ARE NOT COMPLIANT WITH
 THIS DESIGN PRESSURE REQUIREMENT (-176PSF).
  
 14.)THE APPLICATON STATES "REMOVING ALL REAR WINDOWS
 AND BLOCKING THEM UP."THE NEW REAR ELEVATION A1 SHOWS
 THE EXISTING WINDOWS.PERMIT APPLICATION SHOULD BE
 CONSISTENT WITH THE PLAN AND THE SCOPE OF WORK.
  
 15.)THE NEW SOUTH ELEVATION SHOWS NEW FIXED GLASS AND
 A RECTANGLE AROUND THE WINDOW.WHAT IS THIS?THE
 OPENING APPEARS LARGER.PROVIDE DETAILS AND CLARIFY
 SCOPE OF WORK.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-11-27 Cont ID  
Sent By adarroug Date 2007-11-27 Time 08:51 Rev Time 0.00
Received By adarroug Date 2007-11-27 Time 08:51 Sent To B
Notes
2007-11-27 08:52:15TO "SHILL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-15 Cont ID  
Sent By adarroug Date 2007-05-15 Time 09:17 Rev Time 0.00
Received By adarroug Date 2007-05-15 Time 09:17 Sent To B
Notes
2007-05-15 09:18:13TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-04-27 Cont ID  
Sent By adarroug Date 2007-04-27 Time 11:38 Rev Time 0.00
Received By adarroug Date 2007-04-27 Time 11:38 Sent To Z
Notes
2007-04-27 11:39:10TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-20 Cont ID  
Sent By shill Date 2007-03-20 Time 11:57 Rev Time 0.00
Received By shill Date 2007-02-21 Time 11:36 Sent To  
Notes
2007-02-22 09:31:56TO "MISC" BOX#1

Review Stop Z ZONING
Rev No 4 Status P Date 2007-05-30 Cont ID  
Sent By astelly Date 2007-05-30 Time 14:42 Rev Time 0.00
Received By astelly Date 2007-05-30 Time 14:42 Sent To  
Notes
2007-05-30 14:47:33PROVISO
  
 AMY F. STELLY
 URBAN DESIGN
 822-1440
  
 PLEASE SUBMIT AN UPDATED SURVEY FOR THE PROPERTY.
  
 PLEASE PROVIDE 2 PARKING SPSACES/1000 SQ.FT AS PER
 ARTICLE IV, SEC 94-108(D)
  
 THERE IS NO ACCSEEIBLE ROUTE TO THE BUILDING.
  
 TWO-WAY DRIVE AISLES FOR 90 DEGREE PARKING MUST BE A
 MINIMUM OF 24 FEET.
  
 PLEASE CONSULT ARTICLE IV, SEC 94-443 FOR LANDSCAPE
 BUFFER REQUIREMENTS.
  
 THE REQUIRED RETAIL AREA MUST BE 30 FEET IN DEPTH AS
 PER SEC 94-108(3)(C).
  
 A HOLD WILL BE PLACED ON ALL OCCUPATIONAL LICENSES FOR
 THIS ADDRESS UNTIL ALL OF THE ZONING REQUIREMENTS ARE
 SATISFIED.

Review Stop Z ZONING
Rev No 3 Status F Date 2007-05-11 Cont ID  
Sent By astelly Date 2007-05-11 Time 13:49 Rev Time 0.00
Received By astelly Date 2007-05-11 Time 13:49 Sent To I
Notes
2007-05-11 15:07:28AMY F. STELLY
 URBAN DESIGN
 822-1440
  
 PLEASE SUBMIT AN UPDATED SURVEY FOR THE PROPERTY.
 PLEASE PROVIDE 2 PARKING SPSACES/1000 SQ.FT AS PER
 ARTICLE IV, SEC 94-108(D)
 THERE IS NO ACCSEEIBLE ROUTE TO THE BUILDING.
 TWO-WAY DRIVE AISLES FOR 90 DEGREE PARKING MUST BE A
 MINIMUM OF 24 FEET.
 LANDSCAPE BUFFER MUST BE CARRIED AROUND TO SCREEN OAVED
 DRIVE ON THE NORTH SIDE OF THE PROPERTY.
 PLEASE CONSULT ARTICLE IV, SEC 94-443 FOR LANDSCAPE
 BUFFER REQUIREMENTS.
 THE REQUIRED RETAIL AREA MUST BE 30 FEET IN DEPTH AS
 PER SEC 94-108(3)(C).

Review Stop Z ZONING
Rev No 2 Status F Date 2007-05-07 Cont ID  
Sent By astelly Date 2007-05-07 Time 13:20 Rev Time 0.00
Received By astelly Date 2007-05-07 Time 13:20 Sent To  
Notes
2007-05-07 13:21:12PLEASE SUBMIT A SURVEY FOR THE PROPERTY.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-03-22 Cont ID  
Sent By astelly Date 2007-03-22 Time 18:38 Rev Time 0.00
Received By astelly Date 2007-03-22 Time 18:38 Sent To  
Notes
2007-03-22 18:37:54AMY F. STELLY, URBAN DESIGNER
 561-822-1440
 [email protected]
  
 1) PLEASE UNIFY THE PARCEL ADDRESSED AT 3RD STREET WITH
 THE PARCEL ADDRESSED AS 401 N. ROSEMARY AVE.
  
 2) PLEASE SUBMIT A SURVEY FOR THE PROPERTY.
  
 3) PLEASE SHOW PLANS FOR THE LAYOUT OF THE OFF-STREET
 PARKING, WITH CLEARLY DELINEATED SPACES FOR THE
 DISABLED.
  
 4) PLEASE CONSULT SEC. 94-485 OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS FOR THE GENERAL PROVISIONS OF
 THE PARKING CODE.
  
 5) THE ACCESS DRIVE ON THE NORTHERN SIDE OF THE
 BUILDING MUST BE PAVED WITH A NON-DUSTING SURFACE.
  
 6) THE ACCESS DRIVE ON THE NORTHERN SIDE OF THE
 BUILDING MUST BE DESIGNATED AS ONE-WAY.
  
 7) PLEASE SUBMIT LANDSCAPE PLANS FOR REVIEW.
  
 8) PLEASE INCLUDE ALL EXISTING TREES ON THE SITE AND IN
 THE RIGHT-OF-WAY IN THE LANDSCAPE PLAN.
  
 9) ANY PROPOSED TREE REMOVAL WILL REQUIRE A PERMIT.
  
 10) PLEASE AMEND SITE PLAN NOTES TO REFLECT THE ACTUAL
 CONDITIONS ON SITE AND SCOPE OF WORK.
  
 11) PLEASE AMEND NOTES TO SHOW THE PROPERWEST PALM
 BEACH PROPERTY ADDRESS.
  
 12) STOREFRONT GLAZING MUST BE CLEAR AS REQUIRED BY
 SEC. 94-108(E)(5) OF THE ZONING CODE.
  
 13) MAINTENANCE OF THE EXISTING TRANSOM ABOVE THE
 STOREFRONTS IS PREFERRED.
  
 14) PLEASESHOW AN ELEVATION WITH THE BAHAMA SHUTTERS.
 THE STOREFRONTS MUST NOT BE OBSCURED.
  
 15) PLEASE PROVIDE THE PERCENTAGE OF OPENINGS FOR EACH
 FACADE.
  
 16) THE NOTES INDICATE THAT A CURTAIN WALL SYSTEM WILL
 BE USED. NO CURTAIN WALL IS CURRENTLY SHOWN IN ANY OF
 THE DRAWINGS. IF A CURTAIN WALL IS USED, PLEASE ENSURE
 THAT THE FINISH OF THE CURTAIN WALL IS CONSISTENT WITH
 THE FINISH OF THE STOREFRONTS.
  
 17) THE REGULATING MAP FOR THE DOWNTOWN MASTER PLAN
 REQUIRES RETAIL USES ON 3RD ST. PLEASE DETAIL AND GLAZE
 THE 3RD ST. FRONTAGE AS A STOREFRONT AS REQUIRED BY
 SEC. 94-108(E)(5) OF THE ZONING CODE.
  
 18) PLEASE SUBMIT FLOOR PLANS FOR THE SPACE. DOORS MAY
 NOT SWING INTO THE RIGHT-OF-WAY.
  


Account Summary | Usage Policy | Privacy Policy