Plan Review Stops For Permit 07020441 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
12 |
Status |
P |
Date |
2009-08-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-08-05 |
Time |
07:48 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2009-08-05 |
Time |
07:48 |
Sent To |
|
|
Notes |
2009-08-05 07:48:41 | | | BUILDING PLAN REVIEW | | PERMIT: 07020441 | | ADD: 6600S DIXIE HWY | | CONT: S. E. C. CONSTRUCTION & DEV | | TEL: (561)797-6007 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVISION REVIEW | | ACTION: BUILDING PROVISO: | | AUGUST 5/ 2009 | | 1) SHEETS A-102 &A-105.1 REVISION# 4 PLANS HAVE DELETED | | THE REQUIRED 34" SINK HEIGTH FOR SINKS. DOUG WISE B.O. | | VISITED THE JOBSITE AND DERTERMINED THE ROOM IN | | QUESTION , ROOM# 129 APPEARS TO BE A BREAK ROOM AND THE | | SINK AND COUNTERTOP TO BE AT 34" PER: | | 11-4-24.2 HEIGTH. SINKS SHALL BE MOUNTED WITH COUNTER | | OR RIM NO HIGHER THAN 34" ABOVE THE FINISH FLOOR. | | 11-4.1.1(3) AREAS USED ONLY BY EMPLOYEES AS WORK AREAS. | | AREAS THAT ARE USED ONLY AS WORK AREAS SHALL BE | | DESIGNED AND CONSTRUCTED SO THAT INDIVIDUALS WITH | | DISABILITIES CAN APPROACH, ENTER, AND EXIT THE AREAS. | | THIS CODE DOES NOT REQUIRE THAT ANY AREAS USED ONLY AS | | WORK AREAS BE CONSTRUCTED TO PERMIT MANEUVERING WITHIN | | THE WORK AREA OR BE CONSTRUCTED OR EQUIPPED (I.E., WITH | | RACKS OR SHELVES) TO BE ACCESSIBLE. | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | SURVEY: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
11 |
Status |
F |
Date |
2009-08-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-08-03 |
Time |
15:57 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2009-08-03 |
Time |
14:37 |
Sent To |
|
|
Notes |
2009-08-03 16:15:15 | BUILDING PLAN REVIEW | | PERMIT: 07020441 | | ADD: 6600S DIXIE HWY | | CONT: S. E. C. CONSTRUCTION & DEV | | TEL: (561)797-6007 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVISION REVIEW | | ACTION: DENIED | | 1) SHEETS A-102 &A-105.1 REVISION# 4 PLANS HAVE DELETED | | THE REQUIRED 34" SINK HEIGTH FOR SINKS. | | 11-4-24.2 HEIGTH. SINKS SHALL BE MOUNTED WITH COUNTER | | OR RIM NO HIGHER THAN 34" ABOVE THE FINISH FLOOR. | | 11-4.1.1(3) AREAS USED ONLY BY EMPLOYEES AS WORK AREAS. | | AREAS THAT ARE USED ONLY AS WORK AREAS SHALL BE | | DESIGNED AND CONSTRUCTED SO THAT INDIVIDUALS WITH | | DISABILITIES CAN APPROACH, ENTER, AND EXIT THE AREAS. | | THIS CODE DOES NOT REQUIRE THAT ANY AREAS USED ONLY AS | | WORK AREAS BE CONSTRUCTED TO PERMIT MANEUVERING WITHIN | | THE WORK AREA OR BE CONSTRUCTED OR EQUIPPED (I.E., WITH | | RACKS OR SHELVES) TO BE ACCESSIBLE. | | | | I HAVE REVIEWED THIS REVISION WITH THE BUILDING | | OFFICIAL DOUGWISE AND THE CONCLUSION IS THESE AREAS ARE | | NOT A WORK AREA THAT RESULTS IN SUCH AS A LAB OR | | DOCTORS OFFICE. | | THE OWNERS HAVE THREE OPTIONS; | | A) WRITING A LETTER TO THE BUILDING OFFICAL INDICATING | | THES AREAS ARE GOING TO BE WORK AREAS EXEMPTING THEM | | FROM THE REQUIRMENTS OF 11-4.1.1(3). IN DOING SUCH IT | | WILL CREATE A BUILDING | | STIPULATION THAT WILL PRINT ON THE C.O AS WELL AS TIE | | TO THE LAND FILE, WHEN TENANTS APPLY FOR THEIR | | OCCUPATIONAL LICENSE IT WILL LIMIT TTHE USAGE OF THE | | BUILDING. | | | | B) APPLY TO THE STATE FOR A WAIVER OF THE ACCESSIBILITY | | CODE. | | | | C) REMOVE THE REVISION AND LET THE PLANS STAND AS A 34" | | HEIGTH SINK AS THE PLANS WERE PERMITTED. | | | | I TRIED TO CONTACT TTHE DESIGNER OF RECORD FRIDAY JULY | | 31,2009, AND SPOKE WITH SECRETARY, HE WOULD CALL BACK | | IN THE AFTERNOON, TO DATE NO TELEPHONE CALL | | ARCHITECT JOSE PEROTTI (305)442-1262 | | | | DENIED SETS OF PLANS ARE NOW KEPT BY CITY. | | . | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | SURVEY: | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
10 |
Status |
P |
Date |
2009-08-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-08-03 |
Time |
15:56 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
2009-07-31 |
Time |
11:21 |
Sent To |
|
|
Notes |
2009-08-03 15:56:51 | REVISIUON# 4 SHEET A-601 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
9 |
Status |
P |
Date |
2009-07-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-07-16 |
Time |
11:08 |
Rev Time |
3.33 |
Received By |
jwitmer |
Date |
2009-07-16 |
Time |
11:08 |
Sent To |
PC |
|
Notes |
2009-07-16 11:10:10 | REVISIONS: | | A-101 | | A-102 | | A-103 | | A-201 | | A-202 | | A-601 | | A-602 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
P |
Date |
2009-05-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-05-29 |
Time |
10:57 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
2009-05-29 |
Time |
10:57 |
Sent To |
PC |
|
Notes |
2009-05-29 10:58:40 | REVISION: ENTRY DOORS NOA 04-0427.05 INDUSTRIAL | | MILLWORK CORP TENER SERIES WOOD ENTRY DOORS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2009-02-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-02-19 |
Time |
11:24 |
Rev Time |
1.11 |
Received By |
jwitmer |
Date |
2009-02-19 |
Time |
11:24 |
Sent To |
|
|
Notes |
2009-02-19 11:31:02 | REVISIONS; | | REVIEWED | | ENGINEERS' LETTER ALLOWING 1X BUCKS INSTEAD OF 2X BUCKS | | AS ILLUSTRATED ON SHEET S3 DETAIL# 2. | | A-601 NEW WALL DETAILS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2009-02-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-02-19 |
Time |
11:22 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2009-02-19 |
Time |
11:22 |
Sent To |
PC |
|
Notes |
2009-02-19 11:24:24 | REVISION DATED 1-19-09 | | REVIEWED: | | A-201 | | A-202 | | A-602 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2009-02-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2009-02-19 |
Time |
08:48 |
Rev Time |
3.33 |
Received By |
jwitmer |
Date |
2009-02-19 |
Time |
08:48 |
Sent To |
|
|
Notes |
2009-02-19 09:10:18 | BUILDING PLAN REVIEW | | PERMIT: 07020441 | | ADD: 6600S DIXIE HWY | | CONT: S. E. C. CONSTRUCTION & DEV | | TEL: (561)797-6007 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVISION REVIEW # 1 DATED 01-19-09 | | ACTION: DENIED | | | | 1) PLEASE CORRECT REVISION NUMBERS TO CORRESPOND WITH | | DATE SEQUENCE. FOR INSTANCE YOU HAVE A REVISION# 1 | | DATED 6-28-07 WHICH WAS THE RESPONCE TO THE BUILDING | | DEPARTMENT COMMENTS. IT IS VERY CONFUSING TO FIND A NEW | | SET OF REVISIONS AND STILL BE REVISION # 1 WHEN THE | | FIRST SET OF REVISIONS OCCURRED 6-28-09. 106.1.1* | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION NATURE AND EXTENT OF WORK | | PROPOSED UNDER THIS REVISION. | | | | 2) SHEET A-102: | | 2A) THE FRONT ENTRY DOORS ARE NOT INDICATED AS A | | REVISION. 106.1.1*. | | | | 2B) THERE ARE FOUR AREAS ON THE PLAN HIGH LIGHTED IN | | RED WHERE THE 18" MANEUVERING CLEARENCES AT DOORS IS | | MISSING 11-4.13.6. ALSO SEE 11-4.1.1(3) ACCESSIBILITY | | FOR WORKERS, AREAS USED ONLY BY EMPLOYEES AS WORK | | AREAS. AREAS THAT ARE USED ONLY AS WORK AREAS SHALL BE | | DESIGNED AND CONSTRUCTED SO THAT INDIVIDUALS WITH | | DISABILITIES CAN APPROACH, ENTER, AND EXIT THE AREAS. | | DOOR 105 | | DOOR 107 | | DOOR 109 | | DOOR 135 | | | | 3) SHEET A103 MAY OR MAY NOT NEED REVISITED DEPENDING | | ON THE REVISIONS TO BE MADE ON SHEET A-102. | | | | | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)805-6731 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2008-10-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-10-17 |
Time |
14:59 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2008-10-17 |
Time |
14:59 |
Sent To |
PC |
|
Notes |
2008-10-17 14:59:43 | S1,S2 & S4 REVISION# 1. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-08-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-08-29 |
Time |
14:26 |
Rev Time |
1.55 |
Received By |
jwitmer |
Date |
2007-08-29 |
Time |
11:53 |
Sent To |
|
|
Notes |
2007-08-29 14:31:20 | BUILDING PROVISOS: | | 07020441 | | 6600 S DIXIE HWY. | | | | 1) THE NEW CUSTOM FRONT ENTRY DOOR TO BE UNDERA | | SEPERATE PERMIT WITH ASSOCIATED FEES AND REVIEW. | | | | 2)109.3.10* IMPACT OF CONSTRUCTION. ALL CONSTRUCTION | | ACTIVITY REGULATED BY THIS CODE SHALL BE PERMORMED IN A | | MANNER SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF | | ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED TO | | AFFECT SAID PROPERTY PURSUANT TO A CONSENT BY THE | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | AGREEABLE TO THE | | APPLICABLE PROPERTY OWNER.THIS INCLUDES BUT IS NOT | | LIMITED TO THE CONTROL OF DUST, NOISE, WATER OR | | DRAINAGE RUN-OFF, DEBRIS, AND THE STORAGE OF | | CONSTRUCTION MATERIALS. NEW CONSTRUCTION ACTIVITY SHALL | | NOT ADVERSELY IMPACT HISTORIC SURFACE WATER DRAINAGE | | FLOWS SERVING ADJACENT PROPERTIES, & MAY REQUIRE | | SPECIAL DRAINAGE DESIGN COMPLYING WITH | | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS | | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, | | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, PATIOS, | | DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | FT OF PERMEABLE LAND AREA ON ANY PARCELL SHALL | | AS A PERMIT CONDITION, PROVIDE A PROFESSIONALLY | | PREPARED DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE | | WITH THIS PARAGRAPH. UPON COMPLETION OF THE | | IMPROVEMENT, A CERTIFICATE FROM A | | LICENSED ENGINEER SHALL BE SUBMITTED TO THE INSPECTOR | | IN ORDER TO RECEIVE APPROVAL OF THE FINAL INSPECTION. | | | | 3) 109.3.10.1 HURRICANE PROTECTION. IT SHALL BE | | UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION RELATED | | MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 HRS. | | AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS.ANY | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO | | SECTION 113 OF THIS CHAPTER. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-06-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-06-27 |
Time |
14:24 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2007-06-27 |
Time |
14:24 |
Sent To |
|
|
Notes |
2007-06-27 14:27:00 | BUILDING PLAN REVIEW | | PERMIT: 07020441 | | ADD: 6600S DIXIE HWY | | CONT: S. E. C. CONSTRUCTION & DEV | | TEL: (561)797-6007 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1) --- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) COMPLIED, HOWEVER THE 90 WITHOUT ACTIVITY MAY RUN | | OUT ON THE NOC REQUIRING IT TO BE REVISED. | | | | 3) PARTIALLY COMPLETE, PLANS SUBMITTED AFTER DEC.8, | | 2006 ARE TO BE DESIGNED UNDER THE 2004 FBC WITH 2006 | | REVISIONS, PLEASE CORRECT. | | | | 4-5) COMPLIED. | | | | 6) 2ND REQUEST, WPB ADMIN CODE 106.3* PRODUCT | | APPROVALS. THOSE PRODUCT WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 7) 2ND REQUEST, WE NEED AGREEMEENT FROM THE DESIGN | | PROFESSIONAL THAT THEY ARE GOING TO COMPLETE THE THIRD | | PARTY QUALITY ASSURANCE FOR THE FRONT DOOR VERIFYING | | THE ASSEMBLY PROCESS AND WE NEED FROM THE DESIGN | | PROFESSIONAL THE REQUIREMENTS FOR THE INSTALLATION OF | | THE DOOR JAMB. IF THE CUSTOM FRONT DOOR DOES HAVE GLASS | | UNITS IT IT OR THE SIDELIGHTS EITHER LARGE MISSLE | | TESTING HAS TO OCCUR OR A PROTECTIVE SHUTTER SYSTEM | | WILL HAVE TO BE ADDED TO THIS PERMIT WITH THE REQUIRED | | PRODUCT APPROVALS AND INFORMATION TO SECURE THE STORM | | SHUTTERS OR PANELS. | | FRONT DOOR TO BE BUILT AS A ONE TIME APPROVAL , THE | | DESIGNER OF RECORD WILL NEED TO SUPERVISE THE ASSEMBLY | | OF THE DOOR AND THE INSTALATION OF DOOR AND FRAME, AND | | SIGN AND SEAL AFFADAVIT TO THE EFFECT. THIS WILL BE A | | PROVISO REQUIRED BEFORE A CERTIFICATE OF COMPLETION CAN | | BE ISSUED. | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-03-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-03-15 |
Time |
15:44 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2007-03-15 |
Time |
15:44 |
Sent To |
|
|
Notes |
2007-03-15 16:21:46 | BUILDING PLAN REVIEW | | PERMIT: 07020441 | | ADD: 6600S DIXIE HWY | | CONT: S. E. C. CONSTRUCTION & DEV | | TEL: (561)797-6007 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1) --- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | THE COURT. | | NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | NOT | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH | | NOTICE IS NULL & VOID. NOTE: 713.13(6) THE POSTING OF | | THE NOTICE OF | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | INSPECTION. | | | | 3) COVER SHEET A-1 DESIGN DATA INDICATES THE DESIGN TO | | ASCE 7-98, THE CURRENT STANDARD UNDER THE 2006 FBC IS | | ASCE 7-02. | | | | 4) PLANS ALSO INDICATE THERE ARE NO OPENINGS IN END | | ZONES, 10% OF 55'-2"OR 5'-2" OR 40% OF BUILDING MEAN | | ROOF HEIGTH13'-0"= 5'-21/2", PLEASE CORRECT THE WINDOWS | | PRESSURES IN THE END ZONES. TABLE 1609.6B. | | | | 5) PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 6) WPB ADMIN CODE 106.3* PRODUCT | | APPROVALS. THOSE PRODUCT WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 7) FRONT DOOR TO BE BUILT AS A ONE TIME APPROVAL , THE | | DESIGNER OF RECORD WILL NEED TO SUPERVISE | | THE ASSEMBLY OF THE DOOR AND THE INSTALATION OF DOOR | | AND FRAME, AND SIGN AND SEAL AFFADAVIT TO THE EFFECT. | | THIS WILL BE A PROVISO REQUIRED BEFORE A CERTIFICATE OF | | COMPLETION CAN BE ISSUED. | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-02 |
Time |
18:40 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-02 |
Time |
18:00 |
Sent To |
|
|
Notes |
2007-08-02 18:40:36 | STAMPED PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2007-06-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-06-05 |
Time |
20:53 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-06-05 |
Time |
19:08 |
Sent To |
|
|
Notes |
2007-06-05 20:55:08 | ** UNSAT ** | | | | *** PLEASE KNOW THAT AS SOME ITEMS ARE NOT SHOWN FOR | | CODE COMPLIANCE AT THIS TIME OR MISSING FOR REVIEW, | | THERE MAY BE NEW COMMENTS ON THE FOLLOWING REVIEW NOT | | YET ABLE TO BE MADE. | | | | ** PLEASE ALSO SEE THERE ARE SEVERAL ITEMS FROM | | PREVIOUS REVIEW WHICH ARE IN NEED OF ADDRESSING AND NEW | | COMMENTS BASED ON REVISED SHEETS OR SUBMITTED DOCUMENTS | | WHICH WERE NOT THE SAME AS PREVIOUS SUBMITTED PLANS. | | PLANS HAVE CHANGED DESIGNERS OF RECORD. | | | | | | 1) NOTE:PLEASE SEE THIS COMMENT REMAINS THE SAME AS | | ONLY THE CODES ON THE ELECTRICAL PLANS WERE CORRECTED. | | THE CODES ON THE ARCHITECTURAL COVER SHEETS WHICH WERE | | OK ON PREVIOUS PLANS ARE NOT THE SAME ON THE NEW | | ARCHITECTURAL SHEETS? | | ELECTRICAL CODE NOT STATED, WRONG LIFE SAFETY CODE, NOT | | THE LATEST CORRECT FBC. | | PLEASE ADJUST. | | PREVIOUS REVIEW NOTE: | | PLEASE KNOW THAT PERMIT APPLICATION HAS BEEN SUBMITTED | | AFTER DECEMBER 8TH, 2006 WHICH PLACES PROJECTS UNDER | | THE NEW CODES ADOPTED BY THE STATE. PLEASE SEE THAT | | THIS SHALL INCLUDE 2006 REVISIONS TO THE 2004 FBC FOR | | ALL TRADES AND THE 2005 NFPA-70. PLEASE KNOW THERE ARE | | CHANGES IN THE FBC WHICH WILL AFFECT DESIGNS FOR ALL | | TRADES. | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | REVIEWER AT A MINIMUM. | | 2004 FBC W/ 2006 REVISIONS. | | 2005 NFPA-70 | | 2002 NFPA-72 | | 2003 NFPA-101 | | | | 2) NOTE: PLEASE NOW SEE MISSING TITLE BLOCK INFORMATION | | FORLANDSCAPE ARCHITECT AND FIRM AS REQUIRED UNDER | | FLORIDA ADMINISTRATIVE CODE 61G1-16.004. PLEASE ALSO | | SEE FLORIDA STATUTES AND 481.219. | | PLEASE SEE MISSING THE REQUIRED PRINTED NAME AND | | PRINTED LICENSE NUMBER OF DESIGNER AND MISSING FIRM | | LICENSE NUMBER ALSO KNOWN AS THE CERTIFICATE OF | | AUTHORIZATION NUMBER. | | | | 3) NOTE: PLEASE SEE THE NEW LANDSCAPE SHEETS NOW | | CONTAIN A *RUBBERSTAMP* FOR THE REQUIRED *ORIGINAL* | | SIGNATURE FROM THE ARCHITECT OF RECORD. PLEASE SEE FS | | 481.221. THIS IS REQUIRED WHETHER OR NOT COMMENT IS | | MADE BY ANY OTHER TRADE. | | | | 4) NOTE: PLEASE SE THE ENERGY CALCULATIONS SUBMITTED IN | | FACT CONTAINS A *RAISED SEAL* OVER *PHOTO-COPIED* | | SIGNATURES AND DATED SHEETS. THIS IS THE SAME ON ALL | | LOCATIONS ON BOTH SETS OF ENERGY CALCULATIONS | | SUBMITTED. | | PLEASE SEE FBC 13-103.1.1.1, FLORIDA STATUTES, 471.025 | | AND FLORIDA ADMINISTRATIVE CODE 61G15-23.002 WHICH | | REQUIRES AN *ORIGINAL SIGNATURE* FOR ALL PLANS AND | | DOCUMENTS SIGNED, DATED AND SEALED BY THE ENGINEER. | | | | 4) NOTE:PLEASE SUBMIT ENERGY/PERFORMANCE CALCULATIONS | | FOR NEW LIGHTING WHICH CORRELATES WITH THE ELECTRICAL | | PLANS AND LIGHTING LEGEND SHOWN. PLEASE SEE LIGHTING AS | | SHOWN ON CALCULATIONS DOES NOT CORRELATE. MANY ARE OK, | | HOWEVER NOT ALL. | | PLEASE GO OVER EACH AND COORDINATE PLANS WITH | | CALCULATIONS. | | PLEASE SEE FBC 2004 W/ 2006 REVISIONS. 13-103.1.1.1, | | 13-415.1.AB.1.1, 13-415.2. | | | | 5) NOTE: PLEASE SEE THAT PLANSNOW INDICATE SOME KIND | | OF *FUTURE* GENERATOR ON SOME SHEETS BUT NOT ON SITE | | PLANS, LANDSCAPE, BUILDING ELECTRICAL ETC. | | PLEASE SEE SPECS/CUT SHEETS ARE BEING SUBMITTED FOR | | THIS UNIT, BUT NO PROVISIONS ON ELECTRICAL PLANS ARE | | BEING GIVEN OR INFORMATION? | | PLEASE KNOW IF ONE IS TO BE INSTALLED BASED ON THE | | PROPOSED LOCATION AT THE REAR OF BUILDING IT DOES NOT | | MEET THE MINIMUM CLEARANCES FOR UNIT FROM BUILDING. | | PLEASE SEE POSSIBLE COMMENTS FROM ZONING FOR PLACING IN | | PARKING AREA. | | PLEASE SEE 90.7, 110.3 | | PLEASE KNOW THE GENERATOR WILL NO BE INCLUDED UNDER | | THIS PERMITTED SET OF PLANS IF NOT INFORMATION IS | | SUBMITTED OR SHOWN. THIS IS A NOTE FOR INFORMATIONAL | | PURPOSE THAT THE UNIT AT LOCATION SHOWN DOES NOT MEET | | CODE. | | FBC 106.1.2 | | | | 6) NOTE:PLEASE COMPLETE CIRCUIT FOR ROOF TOP GFI ON | | PLANS. PLEASE COMPLETE WHAT APPEARS TO BE A DEDICATE | | CIRCUIT IN CONFERENCE ROOM #1. THE SYMBOL IS NOT ON | | LEGEND AND THE CLOSET ONE MENTIONS DEDICATED CIRCUIT?? | | PLEASE CLARIFY. | | FBC 106.1.2, 106.3.5.1.2 | | | | 7) NOTE: PLEASE SEE AS THE PLANS HAVE BEEN REVISED FOR | | MECHANICAL EQUIPMENT; PLEASE SEE 424.3B FOR THE MINIMUM | | OCP REQUIRED FOR HEAT FOR A/C UNITS. (MIN 125%) PLEASE | | ALSO CORRELATE THE OCP SHOWN ON PANEL SCHEDULE *A* WITH | | THE OCP SHOWN IN LOAD CALCULATIONS. | | THIS WILL CHANGE THE BREAKER SIZE, AND CONDUCTORS. | | 240.4,310.16. | | | | 8) NOTE: PLEASE INDICATE THE SIZE AND TYPE OF GROUNDING | | ELECTRODES IN THE NEW REVISED SYSTEM AS SHOWN. LENGTH, | | TYPE OF GROUND RODS ETC. | | 250.50, 250.53 | | FBC 106.1.2, 106.3.5.1.2 | | | | 9) NOTE: PLEASE SEE PANEL *C* ON RISER WHICH DOES NOT | | CORRELATE WITH THE NUMERICAL ELECTRICAL RISER NOTE. | | PLEASE SEE NOTE MENTIONS 100AMP PANEL WITH A 200AMP | | MAIN BREAKER YET PANEL SCHEDULE SHOWS THIS PANEL AS | | 150AMPS? | | THIS IS THE SAME AS PREVIOUS PLANS. | | | | 10) NOTE: PLEASE SEE PANEL *B* AND NOTE ABOVE FOR PANEL | | *C*. PLEASE CORRELATE WITH ELECTRICAL NOTES ALSO AND | | THE RISER WHICH SHOWS NOTE #10. NOTE #10 IS ALSO USED | | FOR PANEL *D*. | | PLEASE CORRELATE. PANEL *B* IS SHOWN AS 150AMP ON | | SCHEDULE AND 200AMPS ON NOTES. | | FBC 106.1.2, 106.3.5.1.2 ADMIN SECTION FOR ADDITIONAL | | INFORMATION. | | | | 11) NOTE: PLEASE SEE PANEL *A* IS STILL SHOWN AS 200A | | MCB ON PANEL SCHEDULE AND YET NOTES FOR PANEL *A* | | INDICATES THIS TO BE A 225AMP PANEL? | | | | 12) NOTE: AS NOTED ABOVE IN NOTE 10 FOR PANEL *C*, | | PLEASE SEE PANEL *D* NOTE WHICH MENTIONS THIS AS A | | 200AMP MCB PANEL YET, PANEL IS SHOWN AS MLO. FBC | | 106.3.5.1.2, 106.1.2 FOR COORDINATION. | | | | ** PLEASE SEE THE SPECS SUBMITTED FOR THE LIGHTING | | SWITCHES SUBMITTED ARE NOT NEEDED AS A LIGHTING CONTROL | | *SYSTEM* IS NO LONGER INDICATED. | | ** PLEASE SEE THE CLOCK SPEC SHEETS ARE NOT NEEDED FOR | | SETS. THANK YOU FOR SUBMITTING TO SHOW UNIT AND | | LISTING. | | | | ** PLEASE KNOW AS SOME OF THE INFORMATION ON WHETHER OR | | NOT A GENERATOR IS GOING TO BE INSTALLED IT IS NOT | | POSSIBLE TO REVIEW FOR THESE ITEMS. | | | | ** PLEASE SEE ONE SET OF PLANS IS REDLINED FOR MANY OF | | THESE ITEMS WHICH MAY HELP TO LOCATE ITEMS AS NOTED. | | | | ** PLEASE KNOW AS STATED ON PREVIOUS REVIEW: PLEASE BE | | SURE TO CALL IF THERE ARE ANY QUESTIONS OR COMMENTS | | WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF THERE ARE | | ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, NOT | | UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO NOT | | HESITATE IN CONTACTING THIS OFFICE AND THIS REVIEWER. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-03-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-03-04 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-03-04 |
Time |
15:44 |
Sent To |
|
|
Notes |
2007-03-04 17:09:14 | ** UNSAT ** | | | | 1) NOTE: PLEASE KNOW THAT PERMIT APPLICATION HAS BEEN | | SUBMITTED AFTER DECEMBER 8TH, 2006 WHICH PLACES | | PROJECTS UNDER THE NEW CODES ADOPTED BY THE STATE. | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH WILL | | AFFECT DESIGNS FOR ALL TRADES. | | PLEASE LIST THE FOLLOWINGON ELECTRICAL SHEETS FOR | | THIS REVIEWER AT A MINIMUM. | | 2004 FBC W/ 2006 REVISIONS.(ALREADY ON MAIN | | ARCHITECTURAL SHEETS) | | 2005 NFPA-70 | | 2002 NFPA-72 | | 2003 NFPA-101 | | | | 2) NOTE: PLEASE SEE MISSING TITLE BLOCK INFORMATION FOR | | ARCHITECT AND FIRM AS REQUIRED UNDER FLORIDA | | ADMINISTRATIVE CODE 61G1-16.004. PLEASE ALSO SEE | | FLORIDA STATUTES AND 481.219. | | PLEASE SEE MISSING THE REQUIRED PRINTED NAME AND | | PRINTED LICENSE NUMBER OF DESIGNER AND MISSING FIRM | | LICENSE NUMBER ALSO KNOWN AS THE CERTIFICATE OF | | AUTHORIZATION NUMBER. | | | | 3) NOTE:PLEASE SUBMIT ENERGY/PERFORMANCE CALCULATIONS | | FOR NEW LIGHTING WHICH CORRELATES WITH THE ELECTRICAL | | PLANS AND LIGHTING SHOWN. PLEASE SEE LIGHTING AS SHOWN | | ON CALCULATIONS DOES NOT CORRELATE. | | PLEASE ALSO BE SURE THESE ARE SIGNED, DATED AND SEALED | | BY THE DESIGNER OF RECORD AND THE PERSON RESPONSIBLE | | FOR ENERGY CALCULATIONS. | | PLEASE SEE THAT AN AUTOMATED METHOD OF LIGHTING | | CONTROLS IS BEING NOTED ON SYMBOL LEGEND HOWEVER THE | | ENERGY CALCULATIONS DO NOT CORRELATE WITH THIS AS THEY | | SHOW *MANUAL ON/OFF* FOR THIS? | | PLEASE BE SURE ONCE THE METHOD OF CONTROLS IS FIGURED | | FOR THE PLANS TO BE SURE TO CORRELATE CONTROL METHODS | | ON THE ENERGY CALCULATIONS/PERFORMANCE CALCULATIONS. | | PLEASE SEE FBC 2004 W/ 2006 REVISIONS. 13-103.1.1.1, | | 13-415.1.AB.1.1, 13-415.2,AND 13-415.2.ABC.1.2 (3) | | FOR TRACK LIGHTING (WHERE APPLICABLE) | | | | 4) NOTE: PLEASE SEE THAT PLANS DO INDICATE SOME | | CONTROLS FOR LIGHTING HOWEVER PLEASE SUBMIT MORE | | INFORMATION FOR SYSTEM BEING PROPOSED. | | FBC 106.1.2 ADMIN SECTION | | 110.3, 90.7 NEC. | | | | 5) NOTE: PLEASE SEE THE ACCESS TO THE ELECTRICAL ROOM | | WILL NOT BE PERMITTED THROUGH A STORAGE ROOM. 240.24. | | PLEASE KNOW THAT ALL ACCESS TO OVER CURRENT PROTECTION | | DEVICES SHALL BE ACCESSIBLE ON A CONTINUING BASIS. | | PLEASE KNOW THIS IS REQUIRED BY THIS OFFICE AND THE | | OFFICE OF THE FIRE MARSHAL. | | PLEASE SEE THE LOCATION OF THE PANEL *D* IS BEING NOTED | | AND SHOWN IN A STORAGE ROOM WHICH IS NOT PERMITTED. | | PLEASE SEE THE LOCATION AND MINIMUM CLEARANCES FOR THE | | ELECTRICAL PANEL(S) NEED TO MEET 110.26. | | PLEASE ALSO SEE 408.7 AND 240.24 FOR LOCATION OF EASILY | | IGNITABLE MATERIALS AND CLOSE PROXIMITY OF COMBUSTIBLES | | WITH OVER CURRENT PROTECTION DEVICES. | | PLEASE ADJUST PLANS. | | | | 6) NOTE:PLEASE SEE PLANS ON ARCHITECTURAL SHEETS | | NOTES SERVICE AS EXISTING HOWEVER THE ELECTRICAL PLANS | | AND RISER SEEM TO NOTE AND INDICATE ALL OF THIS | | EQUIPMENT AS NEW. PLEASE CLARIFY AND ADJUST NOTE ON | | ARCHITECTURAL PLANS IF ALL NEW AS SHOWN. | | FBC 106.1.2, 106.3.5.1.2 | | | | 7) NOTE: PLEASE KNOW THAT THE PLANS NEED TO CORRELATE | | WITH ALL CIRCUIT DESIGNATIONS ON PLANS FOR ROOMS AND | | AREAS. PLEASE SEE TEXT WHICH IS TAKEN FROM COMMENTARY | | IN THE CODE WHICH STATES THE USE OF *GEN LT* ETC IS NOT | | ACCEPTABLE. | | *SECTION 408.4 WAS REVISED FOR THE 2005 CODE TO REQUIRE | | THAT THE IDENTIFICATION FOR EVERY CIRCUIT SUPPLIED BY A | | PANEL-BOARD OR SWITCHBOARD BE LEGIBLE AND CLEARLY STATE | | THE SPECIFIC PURPOSE FOR WHICH THE CIRCUIT IS USED. | | CIRCUITS USED FOR THE SAME PURPOSE MUST BE IDENTIFIED | | AS TO THEIR LOCATION. FOR EXAMPLE, SMALL APPLIANCE | | BRANCH CIRCUITS CAN SUPPLY OUTLETS IN THE KITCHEN, | | DINING ROOM, AND KITCHEN COUNTERTOPS. IDENTIFYING THE | | CIRCUITS AS SMALL APPLIANCE BRANCH CIRCUITS IS NOT | | ACCEPTABLE; INSTEAD, THEY SHOULD BE IDENTIFIED AS | | ``KITCHEN WALL RECEPTACLES,'' ``DINING ROOM FLOOR | | RECEPTACLE,'' OR ``KITCHEN COUNTERTOP RECEPTACLES LEFT | | OF SINK.'' CIRCUIT DIRECTORIES CONTAINING MULTIPLE | | ENTRIES WITH ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT | | PROVIDE THE SUFFICIENT DETAIL REQUIRED BY THIS | | SECTION.* | | 408.4, 310.16, 240.4 ETC | | FBC 106.3.5.1.2 | | | | 8) NOTE: PLEASE SEE MECHANICAL REVIEW COMMENTS AS THE | | M-SHEETS DO NOT SEEM TO INDICATE ANY MECHANICAL | | EQUIPMENT. PLEASE KNOW THAT REVIEW OF EQUIPMENT FOR | | ELECTRICAL COMPLIANCE CAN NOT BE DONE AT THIS TIME. | | PLEASE COMPLETE. | | FBC 106.1.2, 106.3.5.1.2 | | | | 9) NOTE: PLEASE SEE PANEL SCHEDULE *A* IS NOT COMPLETE | | FOR CONDUCTOR SIZES REQUIRED FOR AC EQUIPMENT. PLEASE | | ALSO SEE MISSING LOAD FOR THE RTU. | | PLEASE COMPLETE FOR REVIEW OF CODE COMPLIANCE. 310.16, | | 240.4, 220, 408.4 | | | | 10) NOTE: PLEASE SEE 700.12E FOR CIRCUITING OF | | EMERGENCY AND EXIT LIGHTS. PLEASE SEE MOST ARE | | CIRCUITED CORRECTLY AND ONLY ONE OR SO IS CIRCUITED TO | | OTHER THAN THE LOCAL LIGHTING BRANCH CIRCUIT. | | | | 11) NOTE: PLEASE CLARIFY MEZZANINE LEVEL FOR LIGHTING | | AND CONTROL. | | PLEASE KNOW LIGHTING CONTROL WILL ALSO BE REQUIRED AT | | THE MEZZ LEVEL AND RECEPTACLE FOR SERVICE PER 210.63, | | 210.70. | | | | 12) NOTE: PLEASE SEE PANEL *C* ON RISER WHICH DOES NOT | | CORRELATE WITH THE NUMERICAL ELECTRICAL RISER NOTE. | | PLEASE SEE NOTE MENTIONS 100AMP PANEL WITH A 200AMP | | MAIN BREAKER YET PANEL SCHEDULE SHOWS THIS PANEL AS | | 150AMPS? | | | | 13) NOTE: PLEASE SEE PANEL *B* AND NOTE ABOVE FOR PANEL | | *C*. PLEASE CORRELATE WITH ELECTRICAL NOTES ALSO AND | | THE RISER WHICH SHOWS NOTE #10. NOTE #10 IS ALSO USED | | FOR PANEL *D*. | | PLEASE CORRELATE. | | FBC 106.1.2, 106.3.5.1.2 ADMIN SECTION FOR ADDITIONAL | | INFORMATION. | | | | 14) NOTE: PLEASE SEE NOTE FOR GROUNDING ELECTRODE | | SYSTEM MENTIONS NEW *BLDG STEEL* YET THIS BEING AN | | EXISTING BUILDING IT IS UNCLEAR WHERE THE NEW BUILDING | | STEEL IS BEING SHOWN. REVIEW OF ARCHITECTURAL AND | | STRUCTURAL PLANS DOES NOT REVEAL THIS. | | PLEASE KNOW AS AN EXISTING BUILDING THE FOOTER STEEL IS | | NOT A REQUIRED ATTACHMENT UNLESS NEW.OPENING OF THE | | OLDER EXISTING FOOTER TO MAKE AN ATTACHMENT COULD | | CREATE ISSUES FOR THE STRUCTURAL INTEGRITY OF THE | | EXISTING FOOTER DEPENDING ON THE AGE ETC. | | 250.50 | | | | 15) NOTE: PLEASE CORRELATE THE CIRCUITING FOR CLOCK | | FEED AS THE LOAD AND AMPERAGE ON THE PANEL SCHEDULE, | | PLANSAND LOAD CALCULATIONS LEND THIS TO BE A 20AMP | | AND SINGLE POLE CIRCUIT, HOWEVER THE PANEL SCHEDULE | | SHOWS THIS FEED AS A 2-POLE 30AMP CIRCUIT WITH #10 | | AWG? | | PLEASE CORRELATE. | | FBC 106.3.5.1.2 | | | | 16) NOTE: PLEASE SEE PANEL *D* NOTE WHICH MENTIONS THIS | | AS A 200AMP MCB PANEL YET, PANEL IS SHOWN AS MLO. FBC | | 106.3.5.1.2, 106.1.2 FOR COORDINATION. | | | | ** PLEASE KNOW AS SOME INFORMATION IS NOT SUBMITTED AT | | THIS TIME FOR REVIEW THER MAY BE COMMENTS ON ANY | | FOLLOWING REVIEWS. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2007-10-03 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-10-03 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-10-03 |
Time |
15:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
F |
Date |
2007-08-24 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-08-24 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-08-24 |
Time |
10:42 |
Sent To |
|
|
Notes |
2007-08-24 11:18:07 | **** FAILED **** | | | | 1. WHAT CHANGES YOU MADE FROM LAST TIME WE APPROVED FOR | | ENG REVIEWIN JUNE1,2007, REV 2.?? DID YOU MAKE | | ANY CHANGES IN STORM WATER CALS., PERVIOUS/IMPERVIOUS | | AREA ETC ? PLEASE EXPLAIN. | | 2. YOU HAVE NOT SEALED& SIGNEDP.E. SEAL. IN ALL 3 | | CIVIL DRAWINGS. NEED TO SEAL & SIGN | | 3.YOU HAVE POLLUTION PREVENTION SILT FENCEONLY ON | | EAST & SOUTH SIDE,NEED SOME SILT FENCE ON NORTH & | | WEST SIDE ALSO, PLEASE EXPLAIN. | | 4. AFTER CONTROL STRUCTURE BLEEDING, WHERE STORM WATER | | GOES, EITHER SFWMD OR IN CITY CANAL, PLEASE EXPLAIN | | | | RASIK CHOKSHI805-6723 | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2007-06-01 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-06-01 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-06-01 |
Time |
12:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2007-03-09 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-03-09 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-03-09 |
Time |
08:10 |
Sent To |
M |
|
Notes |
2007-03-09 08:09:19 | PLEASE PROVIDE FOLLOWING INFO: | | | | 1. PLEASE SHOW STANDARDS NOTES OF CITY OF WPB ON | | DRAWINGSFOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, | | PARKING, HANDICAP PARKING, PAINTPER CITY CODES ETC.,, | | MUST MEET PER ADA,,ETC.,ALL THESE STANDARDS & NOTES OF | | CITY OF WPB CAN BE OBTAINED FROM 1000 45TH STREET, ENG | | DEPT. | | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | 3. FIRST FLOOR ELEVATION,MUST MEET FL BLDG CODE, FLOOD | | ZONE, CENTER LINE OF ROAD , SIDEWALK ELEVATION. PLEASE | | SHOW ALL THESE ELEVATIONS ON THE DRAWINGS. | | 4. PLEASE PROVIDE A COPY OF SFWMD PERMIT, GEO-TECH | | REPORT. | | 5.PLEASE SHOW STORM WATER CALCULATIONS, WHAT CRITERIA | | YOU ASSUMEDFOR RUNOFF CAL.,, LIKE 1" OVER ENTIRE SITE | | OR2.5"CRITERIA, ? PRE & POSTPERVIOUS AREA, | | IMPERVIOUS AREA & TOTAL SITE AREA. | | 6. HOW YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES | | AROUND YOUR SITE SO, WE CANSEE THE BEST PIPE TO | | CONNECT WITH THE STORM WATERFROM ALL OTHER STORM | | WATER PIPES. PLEASE SHOW DETAIL OF THE CONTROL | | STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING | | ELEVATION, ETC DID YOU USE EXFILTRATION TRENCH ? | | 7. POLLUTION PREVENTION DETAILS,CLOTHES USED FOR SILT | | ETC., PLANS SHOWING SILT FENCE AROUND THE SITE | | 8. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED | | 9. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | YOUR SITE FOR STORM WATER DRAIN. | | 10. ANY ASBESTOS FOUND OR LEAD IN OLD PAINT MUST BE | | HANDLED BY HEALTH DEPT & FDEP. | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | PERMITTING PROCESS | | | | RASIK CHOKSHI805-6723 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2007-08-30 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-08-30 |
Time |
18:39 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-08-30 |
Time |
18:04 |
Sent To |
|
|
Notes |
2007-08-30 18:35:43 | *****APPROVED**** | | | | | | ALL THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS | | HAVE BEEN ADDRESSED;PLAN SHEETS A-106, A-201, AND E-2 | | WERE STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2007-06-29 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-06-29 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-06-28 |
Time |
16:53 |
Sent To |
|
|
Notes |
2007-06-28 17:27:29 | *****UNSAT**** | | PLEASE NOTE THAT SINCE A NEW SHEET (A-106) HAS BEEN | | ADDED, IT MUST ALSO BE REFLECTED IN THE INDEX OF | | DRAWINGS ON A-001.TO MAINTAIN UNIFORMITY ON THE PLAN | | SHEETS, FOLLOW THE CAPITALIZED GUIDELINES TO THE | | COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW: | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.ADD | | ITEM TO D-101 | | | | 2.NFPA 101- 2003 EDITION SHALL BE REFERENCED. ON | | A-001 RECTIFY #6 UNDER CODES & STANDARDS AND ADD 2004 | | EDITION TO THE FLORIDA FIRE PREVENTION CODE | | | | 3.INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE | | CLASS A OR CLASS B IN EXITS AND EXIT CORRIDORS, CLASS | | A, CLASS B, OR CLASS C IN ALL OTHER AREAS.PLEASE | | SPECIFY.YOUR RESPONSE (ON A-106) INDICATES THAT | | CHAPTER 38/39 SHALL COMPLY.BASED UPON AN EXISTING OR | | A NEW OCCUPANCY,REFER TO THE APPROPIATE CHAPTER. ALSO | | SPECIFY WHAT THE INTERIOR CLASSIFICATION ARE GOING TO | | BE, NOT JUST QUOTING THE CODE. | | | | NEW COMMENT | | | | A.ON SHEET A-106 NOTE #1 REFERS TO NFPA 241 AS LIFE | | SAFETY.PLEASE BE ADVISED THAT NFPA 101 IS THE LIFE | | SAFETY CODE, WHEREAS NFPA 241 IS THE STANDARD FOR | | SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION | | OPERATIONS. | | | | | | | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING, | | INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH | | ITEM WAS ADDRESSED. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2007-03-29 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-03-29 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-03-29 |
Time |
13:10 |
Sent To |
|
|
Notes |
2007-03-29 14:08:42 | *****DENIED***** | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 2.NFPA 101- 2003 EDITION SHALL BE REFERENCED. | | | | 3.INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE | | CLASS A OR CLASS B IN EXITS AND EXIT CORRIDORS, CLASS | | A, CLASS B, OR CLASS C IN ALL OTHER AREAS.PLEASE | | SPECIFY. | | | | 4.SHOW LOCATION OF THE 2A10BC RATED FIRE | | EXTINGUISHER(S) WHICH SATISFY THE 75' TRAVEL DISTANCE. | | | | 5.IF THE BUILDING IS EQUIPPED WITH A FIRE ALARM AND | | (OR) FIRE SPRINKLER SYSTEM, WILL THE SCOPE OF WORK | | CAUSE THE SYSTEM(S) TO BE MODIFIED?IF SO, SEPARATE | | PLANS AND PERMIT WILL BE REQUIRED FOR THE REMODEL. | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING, | | INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH | | ITEM WAS ADDRESSED. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2007-10-05 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-10-05 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-10-05 |
Time |
14:19 |
Sent To |
|
|
Notes |
2007-10-05 14:27:41 | ****************PROVISO**************** | | SEPERATE GAS PERMIT REQUIRED. | | FUTURE GENERATOR GAS PIPING AT OWN RISK, SEPERATE | | GEN/COM PERMIT REQUIRED WITH ZONING, ELECTRICAL AND | | MECHANICAL APPROVAL OF GENERATOR PLACEMENT. | | NOTE: PER FBC-2004 FUEL GAS SECTION, 404.12 OUTLET | | CLOSURES. GAS OUTLETS THAT DO NOT CONNECT TO APPLIANCES | | SHALL BE VALVED AND CAPPED GAS TIGHT. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2007-06-16 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-06-16 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-06-16 |
Time |
16:54 |
Sent To |
|
|
Notes |
2007-06-16 16:56:15 | SEPARATE GAS PERMIT REQUIRED.--GAS TO THE FUTURE | | GENERATOR IS AT CONTRACTORS OWN RISK. THERE IS NO | | GUARANTEE THAT THE LOCATION OF THE FUTURE GENERATOR | | WILL BE APPROVED. THERE MAY BE ZONING OR MECHANICAL | | ISSUES THAT MAY PREVENT THE GENERATOR FROM BEING | | LOCATED WHERE SHOWN.--A SHUT OFF VALVE AND A HARD | | CAP ARE REQUIRED ON THE LINE TO THE FUTURE GENERATOR. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2007-03-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-03-14 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-03-14 |
Time |
11:04 |
Sent To |
|
|
Notes |
2007-03-14 11:07:00 | DENIED | | REFERENCE: FBC-2004 FUEL GAS | | | | 1. SUBMIT THE FOLLOWING INFORMATION FOR THE REQUIRED | | GAS PERMIT: | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2004 | | FUEL GAS CODE. (SHOW THE LENGTH FROM THE METER TO THE | | FIRST RISER), | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | 402.4(33). | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | | | F. INDICATE THE DELIVERY PRESSURE (PSI) | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND THE | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | H. CLEARLY SHOW THE LOCATION AND CAP- | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | OR ASME), THE DISTANCE OF THE TANK FROM | | THE BUILDING AND ADJACENT PROPERTY LINES | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | INGS, AND THE LOCATION OF ANY BUILDING | | OPENINGS BELOW THE RELIEF VALVE OF THE | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | I. CLEARLY INDICATE ON THE PLAN IF THE | | LP TANK IS ABOVE OR BELOW GROUND, AND | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | PER NFPA 58. IF THE TANK | | IS BELOW GROUND THE CONTAINER SHALL BE | | SECURILY ANCHORED PER NFPA 58 SECTION | | 3-2.2.7(H). | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2009-07-29 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-07-29 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-07-29 |
Time |
10:47 |
Sent To |
|
|
Notes |
2009-07-29 10:48:33 | GAVE TO WITMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2009-07-08 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-07-08 |
Time |
16:55 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-07-08 |
Time |
16:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2009-07-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2009-07-07 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2009-07-07 |
Time |
17:00 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2009-05-21 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2009-05-21 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2009-05-19 |
Time |
10:42 |
Sent To |
|
|
Notes |
2009-05-21 10:43:34 | SENT TO JIM WITMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2009-02-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-10 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-10 |
Time |
08:35 |
Sent To |
B |
|
Notes |
2009-02-10 08:35:51 | TO "JWITMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2009-02-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-09 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-09 |
Time |
10:05 |
Sent To |
B |
|
Notes |
2009-02-09 10:05:39 | TO "JWITMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2009-02-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-04 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-04 |
Time |
09:35 |
Sent To |
|
|
Notes |
2009-02-04 09:37:19 | TO "COMM" BD#11 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2009-01-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-01-26 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-01-26 |
Time |
11:03 |
Sent To |
M |
|
Notes |
2009-01-26 11:03:58 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-10-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-10-06 |
Time |
08:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-10-06 |
Time |
08:33 |
Sent To |
B |
|
Notes |
2008-10-06 08:33:29 | TO "JWITMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-09-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-10 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-10 |
Time |
14:26 |
Sent To |
|
|
Notes |
2007-10-01 15:11:31 | TO "COMM" BD#8 | 2007-09-10 14:27:03 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-07-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-20 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-20 |
Time |
10:19 |
Sent To |
|
|
Notes |
2007-08-01 13:30:53 | TO "COMM" BD#13 | 2007-07-20 10:20:45 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-05-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-15 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-15 |
Time |
11:09 |
Sent To |
|
|
Notes |
2007-05-31 14:29:35 | TO "COMM" BD#30 | 2007-05-15 11:09:50 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-03-29 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-03-29 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-02-20 |
Time |
16:19 |
Sent To |
|
|
Notes |
2007-02-26 13:34:48 | TO "COMM" BD#57 | 2007-02-20 16:25:25 | WAITING FOR "COMM" BD |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
2 |
Status |
P |
Date |
2009-07-10 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2009-07-10 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2009-07-10 |
Time |
12:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
L |
LANDSCAPING |
Rev No |
1 |
Status |
F |
Date |
2009-07-08 |
|
|
Cont ID |
|
Sent By |
rkussner |
Date |
2009-07-08 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
rkussner |
Date |
2009-07-08 |
Time |
15:58 |
Sent To |
|
|
Notes |
2009-07-08 16:03:22 | ***LANDSCAPE REVIEW FAILED*** | | | | 1, THE FICUS TREES ALONG THE EAST PERIMETER SHALL BE | | CHANGED TO ANOTHER SPECIES. | | | | 2. ALL NEW LANDSCAPING IN THE LANDSCAPE NODE ADJACENT | | TO DIXIE HIGHWAY SHALL BE REMOVED. PLEASE CONTACT LABAN | | REEVES AT 822-2160 TO DISCUSS THE LANDSCAPE OPTIONS FOR | | THAT PLANTING AREA. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | KUSSNER @ (561) 822-1462. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2009-01-29 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2009-01-29 |
Time |
20:59 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2009-01-29 |
Time |
20:59 |
Sent To |
PC |
|
Notes |
2009-01-29 20:59:48 | REVISION #3: PAGES M.1, M.2, M.3 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-08-08 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-08-08 |
Time |
19:51 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-08-08 |
Time |
19:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-06-05 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-06-05 |
Time |
17:18 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-06-05 |
Time |
14:23 |
Sent To |
|
|
Notes |
2007-06-05 17:18:25 | --------------DENIED------------------ | | | | 1. M.4: FIRE DAMPERS LOCATED WITHIN AIR DISTRIBUTION | | AND SMOKE CONTROL SYSTEMS SHALL BE INSTALLED IN | | ACCORDANCE WITH THE REQUIREMENTS OF THIS SECTION, AND | | THE MANUFACTURER?S INSTALLATION INSTRUCTIONS AND | | LISTING. FBC,M 607.2 | | | | 2. M.4: PLEASE SHOW MEANS OF AUXILIARY DRAIN PROTECTION | | FOR ROOFTOP PACKAGE UNITS PER FBC,M 307.2.3. | | | | 3. M.4: DUCT DETECTOR INSTALLATION DETAIL SHOWS | | DETECTOR IN RETURN DUCT. SMOKE DETECTORS SHALL BE | | INSTALLED IN SUPPLY AIR SYSTEMS WITH A DESIGN CAPACITY | | GREATER THAN 2,000 CFM IN THE SUPPLY AIR DUCT. FBC,M | | 606.2.1. | | | | 4. M.4: WALL CAP DETAIL SHOWS WALL CAP W/ BUILT-IN | | DAMPER. THIS WALL CAP WILL NOT WORK FOR INTAKE IF IT | | HAS A BACKDRAFT DAMPER. ALSO, INTAKE OPENINGS ARE TO BE | | PROTECTED IN ACCORDANCE WITH FBC,M TABLE 401.6. | | | | 5. PLEASE PROVIDE ROOF CURB TO STRUCTURE ATTACHMENT AND | | EQUIPMENT TO CURB ATTACHMENT DETAILS, SHOWING THE | | DESIGN TO MEET 140 MPH WIND LOAD REQUIREMENTS OF FBC CH | | 16. | | | | RONALD J REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-03-17 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-03-17 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-03-17 |
Time |
14:27 |
Sent To |
|
|
Notes |
2007-03-17 16:53:40 | ------------------DENIED------------------- | | | | 1. PLEASE PROVIDE AN EQUIPMENT SCHEDULE ON PLANS. FBC | | 106.3.5.1.4 | | | | 2. PLEASE PROVIDE SUBMITTAL DATA FOR THE FIREPLACE | | INCLUDING MANUFACTURER'S INSTRUCTIONS RELATED TO | | VENTING REQUIREMENTS. | | | | 3. DUCT SMOKE DETECTORS SHALL BE INSTALLED TO MONITOR | | THE ENTIRE AIRFLOW OF THE SYSTEM PER FBC,M 606.3. TO | | ACCOMPLISH THIS, THE DETECTOR NEEDS TO BE LOCATED IN | | THE SUPPLY TRUNK BEFORE FIRST TAP OR BRANCH DUCT. | | CONSULT THE MANUFACTURER'S INSTALLATION INSTRUCTIONS | | FOR MINIMUM REQUIRED DISTANCE FROM BLOWER. AN | | AUDIBLE/VISIBLE NOTIFICATION (HORN/STROBE) IN AN | | APPROVED LOCATION IS REQUIRED UPON ACTIVATION OF THE | | SMOKE DETECTOR PER FBC,M 606.4.1(2) | | | | 4. SOME TRANSFER DUCTS (JUMPERS) ARE NOT SIZED TO MEET | | THE BALANCED RETURN AIR EXCEPTIONS AS LISTED IN FBC,M | | 601.4. IF THESE EXCEPTIONS ARE NOT MET, A FIELD TEST | | WILL BE REQUIRED AT FINAL INSPECTION TO SHOW THAT THE | | REQUIREMENT FOR A MAXIMUM PRESSURE DIFFERENTIAL OF | | 0.01" WC HAS BEEN ACHIEVED. | | | | REVIEWED BY: | | RONALD J REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2007-10-05 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-10-05 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-10-05 |
Time |
14:12 |
Sent To |
G |
|
Notes |
2007-10-05 14:18:46 | ****************PROVISO**************** | | PER FBC-2004 W/06 REV. CHAPTER 11 SECTION 11-4.24.6 | | EXPOSED PIPES AND SURFACES. HOT WATER AND DRAIN PIPES | | EXPOSED UNDER SINKS SHALL BE INSULATED OR OTHERWISE | | CONFIGURED SO AS TO PROTECT AGAINST CONTACT. THERE | | SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER SINK. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2007-08-30 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-08-30 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-08-30 |
Time |
15:07 |
Sent To |
|
|
Notes |
2007-08-30 15:19:03 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 FUEL GAS | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | | | ******FROM PREVIOUS REVIEW: | | ***FROM PREVIOUS REVIEWS: | | | | 1. OK | | 2. OK | | 3. OK | | | | 4. SUBMIT THE FOLLOWING INFORMATION FOR THE REQUIRED | | GAS PERMIT: | | | | A. OK | | B. OK | | C. OK | | D. OK | | E. OK | | F. OK | | G. OK | | H. N/A | | I. N/A | | | | 5. SHT A-8 SHOW COMPLIANCE FOR THE FOLLOWING: | | FOR THE LAVS: | | A. OK | | B. OK | | C. OK | | | | 6. SUBMIT A DETAIL FOR THE DRINKING FOUNTAIN SHOWING | | COMPLIANCE WITH SECTION 11-4.15AND ALL SUBSECTIONS, AS | | WELL AS SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE | | WHO HAVE DIFFICULTY BENDING OR STOOPING. SECTION | | 106.1.1. | | ******RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. PLEASE | | INDICATE WHERE THE RESPONSE HAS BEEN ADDRESSED. | | ***RESPONSE NOTED, BUT THE REQUIREMENT FOR SECTION | | 11-4.1.3(10(A) HAS NOT BEEN ADDRESSED. THE FLOOR PLAN | | SHOWS A SINGLE DRINKING FOUNTAIN, BUT SHT A-105.1 SHOWS | | A HI/LOW. PLEASE CLARIFY. IF A SINGLE DRINKING | | FOUNTAIN, SHOW COMPLIANCE FOR THOSE WHO HAVE DIFFICULTY | | BENDING OR STOOPING. | | | | 7. SUBMIT A DETAIL FOR THE KITCHEN SINK SHOWING | | COMPLIANCE WITH SECTION 11-4.24 AND ALL SUBSECTIONS. | | SUBMIT AN ELEVATION VIEW. CABINET DOORS ARE NOT | | APPROVED FOR THE SINK AREA. SECTION 106.1.1. | | ******RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. PLEASE | | INDICATE WHERE THE RESPONSE HAS BEEN ADDRESSED. | | ***RESPONSE NOTED, BUT SHT A-107 HAS NOT BEEN | | SUBMITTED, NOR IS SHT A-107 INDICATED ON THE SHEET | | INDEX SHT A-001. | | | | **********NEW COMMENTS********** | | | | 1B. OK | | 2B. SHT A-105 THE FIXTURES SHALL BE ACCESSIBLE. PLEASE | | SHOW COMPLIANCE FOR THE FOLLOWING: | | ___FOR THE W/C'S: | | A. OK | | B. OK | | ___FOR THE LAV'S: | | A. OK | | | | 3B. SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION | | 11-4.24 AND ALL SUBSECTIONS FOR THE SINKS IN ROOMS 129 | | & IN THE ROOM LEFT OF ROOM 115. | | ***RESPONSE NOTED, BUT SHT A-107 HAS NOT BEEN | | SUBMITTED, NOR IS SHT A-107 INDICATED ON THE SHEET | | INDEX SHT A-001. | | | | 4B. GAS TO THE FUTURE GENERATOR IS AT CONTRACTORS OWN | | RISK. THERE IS NO GUARANTEE THAT THE LOCATION OF THE | | FUTURE GENERATOR WILL BE APPROVED. THERE MAY BE ZONING | | OR MECHANICAL ISSUES THAT MAY PREVENT THE GENERATOR | | FROM BEING LOCATED WHERE SHOWN. | | ***RESPONSE "COMMENT NOTED FOR FUTURE REFERENCE" WILL | | BE INDICATED ON PLANS WHEN APPROVED. | | | | 5B. SHTS L1 & L2 THE LANDSCAPE FIRM LICENSE NUMBER IS | | REQUIRED IN THE TITLE BLOCK ON ALL SHEETS PER FAC | | 61G1-16.004(2) & FS 481.219, 481.2055. -- STAMPED | | SIGNATURES ARE NOT APPROVED. THE SIGNATURE OF THE | | LANDSCAPE ARCHITECT IS REQUIRED.--THE PRINTED NAME | | OF THE PERSON SEALING THE DOCUMENT SHALL BE INDICATED | | IN THE TITLE BLOCK ON EACH SHEET. | | ***RESPONSE NOTED, SHEETS DELETED. | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-06-16 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-06-16 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-06-16 |
Time |
16:34 |
Sent To |
|
|
Notes |
2007-06-16 16:54:27 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 FUEL GAS | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | | | ******FROM PREVIOUS REVIEW: | | | | 1. SHT A-3 SHOW THE CLEAR FLOOR SPACE FOR THE W/C'S PER | | SECTION 11-4.16.2, THE DRINKING FOUNTAIN PER SECTION | | 11-4.15.5, AND THE KITCHEN SINK PER SECTION 11-4.24.5, | | (FORWARD APPROACH REQUIRED). | | ******RESPONSE NOTED, BUT NO CLEAR FLOOR SPACE FOR THE | | DRINKING FOUNTAINS OR SINKS INDICATED. PLEASE INDICATE | | WHICH SHEET THE COMMENT RESPONSE HAS BEEN ADDRESSED | | | | 2. OK | | 3. OK | | | | 4. SUBMIT THE FOLLOWING INFORMATION FOR THE REQUIRED | | GAS PERMIT: | | | | A. OK | | B. OK | | C. OK | | D. OK | | E. OK | | F. OK | | G. OK | | H. N/A | | I. N/A | | | | 5. SHT A-8 SHOW COMPLIANCE FOR THE FOLLOWING: | | FOR THE LAVS: | | A. 11-4.19.2 CLEARANCE (29") | | ******RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. PLEASE | | INDICATE WHERE THE RESPONSE HAS BEEN ADDRESSED.B. | | 11-4.19.4 EXPOSED PIPES & SURFACES ******RESPONSE | | NOTED, BUT COMMENT NOT ADDRESSED. PLEASE INDICATE WHERE | | THE RESPONSE HAS BEEN ADDRESSED.C. 11-4.91.5 FAUCETS | | ******RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. PLEASE | | INDICATE WHERE THE RESPONSE HAS BEEN ADDRESSED. | | | | 6. SUBMIT A DETAIL FOR THE DRINKING FOUNTAIN SHOWING | | COMPLIANCE WITH SECTION 11-4.15AND ALL SUBSECTIONS, AS | | WELL AS SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE | | WHO HAVE DIFFICULTY BENDING OR STOOPING. SECTION | | 106.1.1. | | ******RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. PLEASE | | INDICATE WHERE THE RESPONSE HAS BEEN ADDRESSED. | | | | 7. SUBMIT A DETAIL FOR THE KITCHEN SINK SHOWING | | COMPLIANCE WITH SECTION 11-4.24 AND ALL SUBSECTIONS. | | SUBMIT AN ELEVATION VIEW. CABINET DOORS ARE NOT | | APPROVED FOR THE SINK AREA. SECTION 106.1.1. | | ******RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. PLEASE | | INDICATE WHERE THE RESPONSE HAS BEEN ADDRESSED. | | | | **********NEW COMMENTS********** | | | | 1B. SHT A-102 A DRINKING FOUNTAIN IS REQUIRED PER TABLE | | 403.1. PLEASE INDICATE THE LOCATION ON THE FLOOR PLAN. | | SECTION 106.1.1. | | | | 2B. SHT A-105 THE FIXTURES SHALL BE ACCESSIBLE. PLEASE | | SHOW COMPLIANCE FOR THE FOLLOWING: | | ___FOR THE W/C'S: | | A. 11-4.16.3 HEIGHT | | B. 11-4.16.5 FLUSH CONTROLS | | ___FOR THE LAV'S: | | A. SEE PREVIOUS COMMENT #5. | | | | 3B. SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION | | 11-4.24 AND ALL SUBSECTIONS FOR THE SINKS IN ROOMS 129 | | & IN THE ROOM LEFT OF ROOM 115. | | | | 4B. GAS TO THE FUTURE GENERATOR IS AT CONTRACTORS OWN | | RISK. THERE IS NO GUARANTEE THAT THE LOCATION OF THE | | FUTURE GENERATOR WILL BE APPROVED. THERE MAY BE ZONING | | OR MECHANICAL ISSUES THAT MAY PREVENT THE GENERATOR | | FROM BEING LOCATED WHERE SHOWN. | | | | 5B. SHTS L1 & L2 THE LANDSCAPE FIRM LICENSE NUMBER IS | | REQUIRED IN THE TITLE BLOCK ON ALL SHEETS PER FAC | | 61G1-16.004(2) & FS 481.219, 481.2055. -- STAMPED | | SIGNATURES ARE NOT APPROVED. THE SIGNATURE OF THE | | LANDSCAPE ARCHITECT IS REQUIRED.--THE PRINTED NAME | | OF THE PERSON SEALING THE DOCUMENT SHALL BE INDICATED | | IN THE TITLE BLOCK ON EACH SHEET. | | | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-03-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-03-13 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-03-13 |
Time |
11:48 |
Sent To |
|
|
Notes |
2007-03-13 13:55:54 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 FUEL GAS | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | | | 1. SHT A-3 SHOW THE CLEAR FLOOR SPACE FOR THE W/C'S PER | | SECTION 11-4.16.2, THE DRINKING FOUNTAIN PER SECTION | | 11-4.15.5, AND THE KITCHEN SINK PER SECTION 11-4.24.5, | | (FORWARD APPROACH REQUIRED). | | | | 2. SHT A-8 PLUMBING SANITARY RISER DIAGRAM DOES NOT | | REFLECT THE FLOOR PLAN, NOR DOES IT MEET CODE | | REQUIREMENTS. TOILET ROOMS #2 SHOW A W/C & A LAV IN | | EACH ROOM ON THE FLOOR PLAN, BUT ON THE RISER DIAGRAM | | AS DRAWN IT INDICATES BOTH W/C'S IN ONE ROOM AND BOTH | | LAVS IN ANOTHER. ALSO THE W/C'S ARE SHOWN CONNECTING TO | | THE BRANCH LINE & TO THE BUILDING DRAIN LINE. W/C'S | | SHALL BE CONNECTED TO THE BRANCH LINE ONLY.--ONLY | | THE FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT | | TO THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY | | ADDITIONAL FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE | | WET VENT. SECTION 909.1. ALL OTHER FIXTURES BESIDES THE | | FIXTURES IN TOILET ROOMS #2 SHALL CONNECT DOWNSTREAM OF | | THE FIXTURES ON TOILET ROOMS #2.--TOILET ROOMS #1 | | ARE SHOWN ON THE LEFT OF TOILET ROOMS #2 ON THE FLOOR | | PLAN, BUT ARE SHOWN ON THE RIGHT SIDE OF TOILET ROOMS | | #2 ON THE RISER DIGARAM.--THE DRINKING FOUNTAIN IS | | NOT SHOWN ON THE RISER DIAGRAM. CORRELATE FLOOR PLAN | | AND RISER. SECTION 106.1.1.--THE LAVS AND W/C'S IN | | TOILET ROOMS #1 ARE NOT VENTED AS SHOWN. SECTION | | 901.2.1.--TRAPS ARE NOT ALLOWED FOR THE W/C'S AS | | THEY HAVE INTEGRAL TRAPS BUILT IN THEM. SECTION 1002.1. | | (SEE ONE SET OF PLANS SHT A-8 FOR AN EXAMPLE OF A RISER | | DIAGRAM THAT REFLECTS THE FLOOR PLAN AND MEETS CODE | | REQUIREMENTS). | | | | 3. SUBMIT A WATER RISER DIAGRAM THAT REFLECT THE FLOOR | | PLAN. SHOW ALL PIPE SIZES, VALVES ECT. SECTION | | 106.3.5.1.3(3)(10)(13). | | | | 4. SUBMIT THE FOLLOWING INFORMATION FOR THE REQUIRED | | GAS PERMIT: | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2004 | | FUEL GAS CODE. (SHOW THE LENGTH FROM THE METER TO THE | | FIRST RISER), | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | 402.4(33). | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | | | F. INDICATE THE DELIVERY PRESSURE (PSI) | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND THE | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | H. CLEARLY SHOW THE LOCATION AND CAP- | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | OR ASME), THE DISTANCE OF THE TANK FROM | | THE BUILDING AND ADJACENT PROPERTY LINES | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | INGS, AND THE LOCATION OF ANY BUILDING | | OPENINGS BELOW THE RELIEF VALVE OF THE | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | I. CLEARLY INDICATE ON THE PLAN IF THE | | LP TANK IS ABOVE OR BELOW GROUND, AND | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | PER NFPA 58. IF THE TANK | | IS BELOW GROUND THE CONTAINER SHALL BE | | SECURILY ANCHORED PER NFPA 58 SECTION | | 3-2.2.7(H). | | | | 5. SHT A-8 SHOW COMPLIANCE FOR THE FOLLOWING: | | FOR THE LAVS: | | A. 11-4.19.2 CLEARANCE (29") | | B. 11-4.19.4 EXPOSED PIPES & SURFACES | | C. 11-4.91.5 FAUCETS | | | | 6. SUBMIT A DETAIL FOR THE DRINKING FOUNTAIN SHOWING | | COMPLIANCE WITH SECTION 11-4.15AND ALL SUBSECTIONS, AS | | WELL AS SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE | | WHO HAVE DIFFICULTY BENDING OR STOOPING. SECTION | | 106.1.1. | | | | 7. SUBMIT A DETAIL FOR THE KITCHEN SINK SHOWING | | COMPLIANCE WITH SECTION 11-4.24 AND ALL SUBSECTIONS. | | SUBMIT AN ELEVATION VIEW. CABINET DOORS ARE NOT | | APPROVED FOR THE SINK AREA. SECTION 106.1.1. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2009-02-09 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2009-02-09 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2009-02-09 |
Time |
08:46 |
Sent To |
|
|
Notes |
2009-02-09 08:52:37 | ***FAILED*** | | | | PLEASE PROVIDE A WRITTEN NOTATION ON THE PLANS STATING | | THE SPECIFIC NATURE OF THE REVISIONS REQUESTED. NOTE | | THAT IN THE PROPOSED LOCATIONS, THE HEIGHT OF BOTH | | GATES MAY NOT EXCEED FOUR (4) FEET. | | | | ON THE SITE PLAN, THERE IS A DUPLICATE BUILDING | | FOOTPRINT IN THE MIDDLE OF SOUTH DIXIE HIGHWAY. PLEASE | | REMOVE IT AND ENSURE THAT RESUBMITTED PLANS ARE FREE OF | | UNNECESSARY MARKS AND LAYERS. | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1435 | | OR [email protected] WITH QUESTIONS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-08-08 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2007-08-08 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2007-08-08 |
Time |
17:07 |
Sent To |
|
|
Notes |
2007-08-08 17:09:56 | NOTE THAT THE GENERATOR SHOWN ON THE GAS/PLUMBING PLANS | | CANNOT BE APPROVED BY ZONING IN THAT LOCATION. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-06-06 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2007-06-06 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2007-06-06 |
Time |
14:24 |
Sent To |
|
|
Notes |
2007-06-06 14:46:43 | ***FAILED*** | | | | DUMPSTER MUST BE A MINIMUM OF 5 FEET FROM PROPERTY | | LINES. AS SHOWN, THE DUMPSTER IS TOO CLOSE TO THE SOUTH | | PROPERTY LINE. | | | | THERE IS A FUTURE GENERATOR SHOWN ON THE PLUMBING | | PLANS. BE AWARE THAT A GENERATOR MAY NOT BE PLACED IN | | THIS LOCATION AS IT BLOCKS ACCESS TO THE PARKING AND | | DRIVE AISLE. IT WOULD APPEAR THE ONLY VIABLE ON-GROUND | | LOCATION WOULD BE IN THE PARKING ROW ALONG THE EAST | | SIDE OF THE PROPERTY. THE BUILDING REQUIRES 14 PARKING | | SPACES AND 16 ARE PROVIDED. TWO SPACES COULD BE REMOVED | | TO ACCOMMODATE THE GENERATOR. PLEASE NOTE THAT | | GENERATORS SHALL BE SCREENED TO THE SAME STANDARDS AS | | DUMPSTER ENCLOSURES. DEPENDING ON YOUR FUTURE PLANS, IT | | MAY BE PRUDENT TO CONSTRUCT A COMBINATION | | DUMPSTER/GENERATOR ENCLOSURE SO THAT A FUTURE GENERATOR | | MAY BE ACCOMMODATED PER CODE REQUIREMENTS. | | | | PLEASE SHOW CODE COMPLIANT STRIPING ON ALL PARKING | | SPACES. | | | | PLEASE CALL KELLY FREEMAN, PLANNER, AT 561-822-1435 | | WITH QUESTIONS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-03-02 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2007-03-02 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2007-03-02 |
Time |
14:17 |
Sent To |
|
|
Notes |
2007-03-02 14:17:44 | **FAILED** | | | | 1) A LANDSCAPE PLAN SIGNED AND SEALED BY A REGISTERED | | LANDSCAPE ARCHITECT SHALL BE PROVIDED. PLEASE SEE | | ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT | | REGULATIONS FOR SPECIFIC REQUIREMENTS. | | | | 2) PLEASE INCLUDE A PARKING SPACE STRIPING DETAIL THAT | | CONFORMS TO THE REQUIREMENTS OF SECTION 94-485 OF THE | | ZONING AND LAND DEVELOPMENT REGULATIONS. | | | | 3) PLEASE PROVIDE A DETAIL AND ELEVATIONS FOR YOUR | | DUMPSTER ENCLOSURE. YOU MAY WANT TO CONSIDER ENLARGING | | THE ENCLOSURE TO THE NORTH TO ACCOMMODATE A RECYCLING | | CENTER. | | | | 4) ALL PARKING SPACES WILL BE REQUIRED TO HAVE WHEEL | | STOPS LOCATED 2 FEET FROM THE FRONT OF THE SPACES. | | | | 5) THE SECTIONS OF THE BUILDING IN THE SETBACKS (NORTH | | AND WEST ELEVATIONS) MAY NOT BE EXTENDED ABOVE THEIR | | EXISTING HEIGHTS. THIS APPLIES TO THE CLOCK TOWER | | ELEMENT AND THE PARAPET WALLS. | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1435 | | WITH QUESTIONS AND SPECIFIC INFORMATION ABOUT | | LANDSCAPING REQUIREMENTS. |
|
|