Plan Review Details - Permit 07020382
Plan Review Stops For Permit 07020382 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-03-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-23 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-03-23 |
Time |
17:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-03-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-13 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-03-13 |
Time |
17:00 |
Sent To |
|
|
Notes |
2007-03-13 17:04:32 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | 1.)ON SHEET 8 OF THE ASSA PRODUCT APPROVAL, YOU HAVE | | CIRCLED 47.8, MAX OF 12' SPAN.SEE OPENING 3, 66 PSF | | EXCEEDS THE MAXIMUM PANEL SPAN.THE INFORMATION | | CIRCLED ON THE PRODUCT APPROVAL SHOULD CORRELATE WITH | | THE JOB. | | | | 2.)4" SPACING IS REQUIRED FOR SPANS OVER 8'6, | | 61.9-75.3 PSF.YOU HAVE SPECIFIED 8" ON THE | | INSTALLATION SCHEDULE. | | | | 3.)YOU HAVE CIRCLED 6' SPAN ON THE CHART FOR THE | | PANELS, BUT THE 85" OPENING DOES NOT SPECIFY IF YOU ARE | | INSTALLING VERTICALLY OR HORIZONTALLY SO SHOULD USE THE | | WORST CONDITION.THE ANCHORING IS THE SAME, BUT THE | | INFORMATION CIRCLED ON THE PRODUCT APPROVAL SHOULD | | CORRELATE WITH THE INSTALLATION SCHEDULE. \ | | | | 4.)PLEASE CONTACT ME IF YOU NEED ASSISTANCE IN | | DETERMINING HOW TO SUBMIT CODE COMPLIANT PAPERWORK. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-03-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-07 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-03-07 |
Time |
11:24 |
Sent To |
|
|
Notes |
2007-03-07 11:26:13 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBEXISTING BUILDING CODE 2004 | | FBC R RESIDENTIAL 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | FBC2004 | | | | 1.)NO ACCORDION ANCHOR SPACING IS SPECIFIED ON THE | | INSTALLATION SCHEDULE. | | | | ALSO PLEASE CLARIFY WHAT "F" IS, SHUTTER WIDTH AND | | HEIGHT FOR OPENING 3. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-03-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-19 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-19 |
Time |
09:51 |
Sent To |
B |
|
Notes |
2007-03-19 09:51:41 | TO "SHILL" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-03-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-10 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-10 |
Time |
15:14 |
Sent To |
B |
|
Notes |
2007-03-10 15:14:49 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-03-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-07 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-02-15 |
Time |
14:51 |
Sent To |
|
|
Notes |
2007-02-15 14:51:51 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy