Plan Review Stops For Permit 07020358 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
F |
Date |
2008-02-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-02-06 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-02-06 |
Time |
10:31 |
Sent To |
|
|
Notes |
2008-02-06 10:35:10 | 2004 FBC W/2006 REVISIONS | | LEVEL 2 ALTERATION AND ADDITION | | | | REVISION TO ENCLOSE CARPORT INTO A GARAGE IS DENIED BY | | BUILDING | | | | 1) THE VALUE OF THE REVISED WORK ($ 15,000.00) HAS BEEN | | ADDED TO THE PREVIOUS VALUE OF WORK. ADDITIONAL FEES OF | | $4 | | | | 2) WHEN MAKING REVISIONS TO APPROVED PLANS, THE NEW | | PLANS ARE REQUIRED TO CONTAIN THE INFORMATION ON THE | | OLD DRAWINGS THAT IS NOT BEING CHANGED, AS WELL AS, THE | | NEW INFORMATION. THE REVISED/NEW INFORMATION SHOULD BE | | CLOUDED AND LABELED WITH THE REVISION NUMBER. SEE FBC | | 106.1.3* AND 106.1.1* CITY AMENDMENTS. NOTE: THESE | | PLANS NEED TO SHOW THE SCOPE OF WORK FOR THE ENTIRE | | PROJECT IN ADDITION TO THE REVISION TO ENCLOSE THE | | GARAGE. SOME OF THE INFORMATION FROM THE APPROVED PLANS | | WAS NOT SHOWN ON THE REVISED SHEET A-1. | | | | 3) COMPLIED. | | | | 4) THE WEST ELEVATION WAS ADDED TO PLANS. HOWEVER, THE | | EAST ELEVATION WAS ELIMINATED. PLEASE SHOW BOTH | | ELEVATIONS ON THE DRAWINGS. FBC 106.1.1* CITY | | AMENDMENTS. | | | | 5) COMPLIED. | | | | 6) COMPLIED. | | | | 7) COMPLIED. | | | | 8) SUBMIT PRODUCT APPROVALS FOR THE OVERHEAD GARAGE | | DOOR, THE SIDE SWING GARAGE DOOR, THE ROOF COVERING. | | SEE FAC RULE 9B-72. THE PRODUCT APPROVALS THAT WERE | | SUBMITTED ARE FOR GAF RIDGE CAP SHINGLES AND THEY WERE | | NOT APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 9)FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 10) COMPLIED. | | | | 11) SHOW COMPLIANCE WITHR302.1 EXTERIOR WALLS. | | EXTERIOR WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM) | | SHALL HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE | | RATING WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL | | NOT EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM | | AN ADJACENT PROJECTION OR WALL. PROJECTIONS EXTENDING | | INTO THE 6-FOOT (1829 MM) SEPARATION DISTANCE SHALL | | HAVE NOT LESS THAN 1-HOUR FIRE-RESISTIVE CONSTRUCTION | | ON THE UNDERSIDE. | | R302.2 OPENINGS. | | OPENINGS SHALL NOT BE PERMITTED IN THE EXTERIOR WALL OF | | A DWELLING OR ACCESSORY BUILDING THAT IS SEPARATED FROM | | AN ADJACENT BUILDING BY A DISTANCE OF LESS THAN 6 FEET | | (1828 MM). THIS DISTANCE SHALL BE MEASURED | | PERPENDICULAR TO THE LINE USED TO DETERMINE THE | | SEPARATION DISTANCE. | | THE NEW GARAGE WALLS APPEAR TO BE LESS THAN 6 FEET FROM | | THE PROPERTY LINE. PROVIDE A SURVEY/SITE PLAN THAT | | INDICATES THAT THE DISTANCE TO STRUCTURES ON THE | | ADJACENT PROPERTY WILL COMPLY WITH THE REQUIRED | | DISTANCES OR COMPLY WITH THE CODE SECTIONS LISTED | | ABOVE. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2008-01-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-01-10 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-01-10 |
Time |
07:04 |
Sent To |
Z |
|
Notes |
2008-01-10 10:50:46 | 2004 FBC W/2006 REVISIONS | | LEVEL 2 ALTERATION AND ADDITION | | | | REVISION TO ENCLOSE CARPORT INTO A GARAGE IS DENIED BY | | BUILDING | | | | 1) SPECIFY THE VALUE OF THE ADDITIONAL WORK (CURRENTLY | | $21,013.00) AND PAY ADDITIONAL PERMIT FEES. SEE FBC | | 108.1* AND 108.2* CITY AMENDMENTS. | | | | 2) WHEN MAKING REVISIONS TO APPROVED PLANS, THE NEW | | PLANS ARE REQUIRED TO CONTAIN THE INFORMATION ON THE | | OLD DRAWINGS THAT IS NOT BEING CHANGED, AS WELL AS, THE | | NEW INFORMATION. THE REVISED/NEW INFORMATION SHOULD BE | | CLOUDED AND LABELED WITH THE REVISION NUMBER. SEE FBC | | 106.1.3* AND 106.1.1* CITY AMENDMENTS. NOTE: THESE | | PLANS NEED TO SHOW THE SCOPE OF WORK FOR THE ENTIRE | | PROJECT IN ADDITION TO THE REVISION TO ENCLOSE THE | | GARAGE. SOME OF THE INFORMATION FROM THE APPROVED PLANS | | WAS NOT SHOWN ON THE REVISED SHEET A-1. | | | | 3) COMPLIED. | | | | 4) THE WEST ELEVATION WAS ADDED TO PLANS. HOWEVER, THE | | EAST ELEVATION WAS ELIMINATED. PLEASE SHOW BOTH | | ELEVATIONS ON THE DRAWINGS. FBC 106.1.1* CITY | | AMENDMENTS. | | | | 5) COMPLIED. | | | | 6) COMPLIED. | | | | 7) COMPLIED. | | | | 8) SUBMIT PRODUCT APPROVALS FOR THE OVERHEAD GARAGE | | DOOR, THE SIDE SWING GARAGE DOOR, THE ROOF COVERING. | | SEE FAC RULE 9B-72. THE PRODUCT APPROVALS THAT WERE | | SUBMITTED ARE FOR GAF RIDGE CAP SHINGLES AND THEY WERE | | NOT APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | 9)FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 10) COMPLIED. | | | | 11) SHOW COMPLIANCE WITHR302.1 EXTERIOR WALLS. | | EXTERIOR WALLS SEPARATED BY LESS THAN 6 FEET (1828 MM) | | SHALL HAVE NOT LESS THAN A ONE-HOUR FIRE-RESISTIVE | | RATING WITH EXPOSURE FROM BOTH SIDES. PROJECTIONS SHALL | | NOT EXTEND TO A POINT CLOSER THAN 4 FEET (1220 MM) FROM | | AN ADJACENT PROJECTION OR WALL. PROJECTIONS EXTENDING | | INTO THE 6-FOOT (1829 MM) SEPARATION DISTANCE SHALL | | HAVE NOT LESS THAN 1-HOUR FIRE-RESISTIVE CONSTRUCTION | | ON THE UNDERSIDE. | | R302.2 OPENINGS. | | OPENINGS SHALL NOT BE PERMITTED IN THE EXTERIOR WALL OF | | A DWELLING OR ACCESSORY BUILDING THAT IS SEPARATED FROM | | AN ADJACENT BUILDING BY A DISTANCE OF LESS THAN 6 FEET | | (1828 MM). THIS DISTANCE SHALL BE MEASURED | | PERPENDICULAR TO THE LINE USED TO DETERMINE THE | | SEPARATION DISTANCE. | | THE NEW GARAGE WALLS APPEAR TO BE LESS THAN 6 FEET FROM | | THE PROPERTY LINE. PROVIDE A SURVEY/SITE PLAN THAT | | INDICATES THAT THE DISTANCE TO STRUCTURES ON THE | | ADJACENT PROPERTY WILL COMPLY WITH THE REQUIRED | | DISTANCES OR COMPLY WITH THE CODE SECTIONS LISTED | | ABOVE. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2007-11-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-11-26 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-11-26 |
Time |
07:22 |
Sent To |
Z |
|
Notes |
2007-11-26 10:40:11 | 2004 FBC W/2006 REVISIONS | | LEVEL 2 ALTERATION AND ADDITION | | | | REVISION TO ENCLOSE CARPORT INTO A GARAGE IS DENIED BY | | BUILDING | | | | 1) SPECIFY THE VALUE OF THE ADDITIONAL WORK (CURRENTLY | | $21,013.00) AND PAY ADDITIONAL PERMIT FEES. SEE FBC | | 108.1* AND 108.2* CITY AMENDMENTS. | | | | 2) WHEN MAKING REVISIONS TO APPROVED PLANS, THE NEW | | PLANS ARE REQUIRED TO CONTAIN THE INFORMATION ON THE | | OLD DRAWINGS THAT IS NOT BEING CHANGED, AS WELL AS, THE | | NEW INFORMATION. THE REVISED/NEW INFORMATION SHOULD BE | | CLOUDED AND LABELED WITH THE REVISION NUMBER. SEE FBC | | 106.1.3* AND 106.1.1* CITY AMENDMENTS. | | | | 3) THE DETAILS ON SHEET D-1 DO NOT CORRESPOND WITH THE | | FRONT ELEVATION SHOWN ON A-1. THE ELEVATION SHOWS A | | GABLE AT THE RIGHT SIDE. PLEASE CLARIFY. FBC 106.1.1* | | CITY AMENDMENTS | | | | 4) THE RIGHT SIDE ELEVATION IS NOT LABELED ON SHEET | | A-1. FBC 106.1.1* CITY AMENDMENTS | | | | 5) SPECIFY THE SIZE AND SPACING OF THE ROOF RAFTERS. | | FBC 106.1.1* CITY AMENDMENTS | | | | 6) SPECIFY THE SPACING OF THE 2 X 6 WALL FRAMING. FBC | | 106.1.1* CITY AMENDMENTS | | | | 7) SPECIFY THE WALL COVERING FOR THE GABLE END ON THE | | RIGHT ELEVATION. FBC 106.1.1* CITY AMENDMENTS | | | | 8) SUBMIT PRODUCT APPROVALS FOR THE OVERHEAD GARAGE | | DOOR, THE SIDE SWING GARAGE DOOR, THE ROOF COVERING. | | SEE FAC RULE 9B-72. | | | | 9)106.3* PRODUCT APPROVALS. THOSE PRODUCT WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 10) THE ROOF SHEATHING NAILING INFORMATION ON SHEET D-1 | | IS INCORRECT. PLEASE REVISE. ROOF SHEATHING IS REQUIRED | | TO BE IN ACCORDANCE WITH SECTION R803.2.3.1 OF 2006 | | REVISIONS TO 2004 FBC RESIDENTIAL CODE. WOOD STRUCTURAL | | PANEL SHEATHING SHALL BE FASTENED TO ROOF FRAMING WITH | | 8D RING-SHANK NAILS AT 6 INCHES ON CENTER AT EDGES AND | | 6 INCHES ON CENTER AT INTERMEDIATE FRAMING. SPACING OF | | RING-SHANK FASTENERS SHALL BE 4 INCHES ON CENTER IN | | NAILING ZONE 3 FOR 130 MPH OR GREATER DESIGN WIND | | SPEEDS IN ACCORDANCE WITH FIGURE R803.2.3.1. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-07-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-07-11 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-07-11 |
Time |
07:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-07-06 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-07-06 |
Time |
09:18 |
Sent To |
|
|
Notes |
2007-07-06 10:44:39 | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) THE SYSTEM THAT WAS SELECTED FOR THE FIRESTONE | | MODIFIED ROOF SYSTEM ON PAGE 31 OF NOA 05-0830.10, DOES | | NOT ALLOW ENHANCED FASTENING TO INCREASE THE DESIGN | | PRESSURE. THEREFORE, THE CALCULATIONS FROM THE ENGINEER | | FOR ENHANCED FASTENING ARE NOT ALLOWED. SEE LIMITATION | | #9 ON PAGE 34 OF THE NOA. ONE SET OF THE ENGINEER'S | | CALCULATIONS HAVE BEEN RETAINED. | | | | 3) THE ENERGY CALCULATION FORM THAT WAS SUBMITTTED IS | | OUTDATED. SUBMIT THE CURRENT ONE, WHICH IS FORM | | 600C-04. | | | | 4) THE OWNER/ AGENT IS REQUIRED TO SIGN THE ENERGY | | CALCULATION FORM. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-04-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-04-26 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-04-26 |
Time |
06:52 |
Sent To |
|
|
Notes |
2007-04-26 10:17:44 | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 3) SUBMIT TWO CLEAR AND LEGIBLE COPIES OF ALL PRODUCT | | APPROVALS. NOTE: THESE WILL BE COPIED INTO FILES FOR | | RECORD RETENTION. THEREFORE, THEY MUST BE CLEAR AND | | READABLE. | | | | 4)PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. SEE THE FL. COVERSHEET FOR THE FIRESTONE ROOFING | | MATERIAL ATTACHED TO THIS REVIEW. | | | | 5)WPB ADMIN CODE 106.3* PRODUCT | | APPROVALS. THOSE PRODUCT WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. THE LETTER FROM THE | | DESIGNER OF RECORD DOES NOT INCLUDE ALL OF THE ITEMS | | REQUIRED TO HAVE PRODUCT APPROVALS SUBMITTED BY RULE | | 9B-72. | | | | 6) SUBMIT PRODUCT APPROVALS FOR THE GLASS BLOCK, THE | | OUTSWING EXTERIOR GARAGE DOOR, THE 8' X 7' OVERHEAD | | GARAGE DOOR, THE SIMPSON AND USP CONNECTORS AND THE | | SINGLE HUNG WINDOWS. | | | | 7) THE PRODUCT APPROVAL NOA SUBMITTED FOR THE PGT | | SGD-70, SLIDING GLASS DOOR, HAS PAGES OF THE NOA THAT | | ARE ILLEGIBLE. THE ENTIRE REPORT MUST BE LEGIBLE. | | | | 8)SPECIFY WHICH ONE OF THE APPROVED ASSEMBLIES LISTED | | IN THE NOA FOR THE FIRESTONE MODIFIED ROOF SYSTEM WILL | | BE INSTALLED. INDICATE THE FASTENING OPTION THAT WILL | | BE USED AND DESIGN PRESSURE FOR THE SELECTED ASSEMBLY. | | CIRCLE THE APPROPRIATE ITEMS ON THE NOA. THE REQUIRED | | UPLIFT PRESSURES ARE -59.2 FOR ROOF ZONE 2 AND -89.0 | | FOR ROOF ZONE 3. IF THE DESIGN PRESSURES ARE TOO LOW | | FOR THESE AREAS, SUBMIT RAS 117 CALCULATIONS PER | | GENERAL LIMITATION #7. SEE PAGE 34 OF THE NOA. | | | | 9) NO ENERGY CALCULATIONS WERE SUBMITTED. PLEASE SUBMIT | | THE 2004 FORMS # 600C-04 . THE OWNER/AGENT IS REQUIRED | | TO SIGN THE ENERGY CALC. FORM. SEE FBC CHAPTER 13. | | | | 10) AN EMERGENCY ESCAPE AND RESCUE OPENING TO THE | | EXTERIOR REQUIRED BY FBC R310 MUST BE PROVIDED AT THE | | EXISTING BEDROOM ADJACENT TO THE ADDITION WHICH HAS THE | | REAR WINDOWSTHAT ARE BEING ENCLOSED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-03-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-03-29 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-03-29 |
Time |
07:27 |
Sent To |
|
|
Notes |
2007-03-29 09:30:00 | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 3) SUBMIT TWO LEGIBLE COPIES OF THE PRODUCT APPROVALS. | | | | 4)PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. | | | | 5)WPB ADMIN CODE 106.3* PRODUCT | | APPROVALS. THOSE PRODUCT WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 6) SUBMIT PRODUCT APPROVALS FOR THE GLASS BLOCK AND | | SINGLE HUNG WINDOW. | | | | 7) THE PRODUCT APPROVAL NOA SUBMITTED FOR THE PGT | | SGD-70, SLIDING GLASS DOOR, HAS BEEN REVISED BY NOA # | | 06-0523.03. SUBMIT CURRENT NOA. | | | | 8)SPECIFY WHICH ONE OF THE APPROVED ASSEMBLIES LISTED | | IN THE NOA FOR THE FIRESTONE MODIFIED ROOF SYSTEM WILL | | BE INSTALLED. INDICATE THE FASTENING OPTION THAT WILL | | BE USED AND DESIGN PRESSURE FOR THE SELECTED ASSEMBLY | | BY CIRCLING THE APPROPRIATE ITEMS ON THE NOA. THE | | REQUIRED UPLIFT PRESSURES ARE -59.2 FOR ROOF ZONE 2 NAD | | -89.0 FOR ROOF ZONE 3. IF THE DESIGN PRESSURES ARE TOO | | LOW FOR THESE AREAS, SUBMIT RAS 117 CALCULATIONS IF | | ALLOWED BY GENERAL LIMITATION #7 ON PAGE 34 OF THE | | NOA. | | | | | | 9) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED | | GRADE. | | CONCRETE AND MASONRY FOUNDATION WALLS SHALL EXTEND | | ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT | | ALL POINTS A MINIMUM OF 4 INCHES (102 MM) WHERE MASONRY | | VENEER IS USED AND A MINIMUM OF 6 INCHES (152 MM) | | ELSEWHERE. | | | | 10) SHOW COMPLIANCE WITH SECTION 704 INSPECTION FOR | | TERMITES. | | IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE | | INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS | | AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING | | SHALL NOT BE LESS THAN 6 INCHES (152 MM). EXCEPTIONS: | | 1.PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS | | THAN 5 / 8 INCH (17.1 MM) THICK ADHERED DIRECTLY TO THE | | MASONRY FOUNDATION SIDEWALL. | | 2.ACCESS OR VEHICLE RAMPS WHICH RISE TO THE | | INTERIOR FINISH FLOOR ELEVATION FOR THE WIDTH OF SUCH | | RAMPS ONLY. | | 3.A 4-INCH (102 MM) INSPECTION SPACE ABOVE PATIO | | AND GARAGE SLABS AND ENTRY AREAS. | | 4.IF THE PATIO HAS BEEN SOIL TREATED FOR TERMITES, | | THE FINISH ELEVATION MAY MATCH THE BUILDING INTERIOR | | FINISH FLOOR ELEVATIONS ON MASONRY CONSTRUCTION ONLY. | | 5.MASONRY VENEERS. | | | | 11) DETAIL F1 ON S1 SHOWS A 1-1/2" X 8" RECESS AT THE | | EXTERIOR OF THE MONOLITHIC FOUNDATION AND THE WALL | | SECTION ON D1 DOES NOT. PLEASE CLARIFY. | | | | 12) SHOW COMPLIANCE WITH R301.2.1.2 INTERNAL PRESSURE. | | | | WINDOWS IN BUILDINGS LOCATED IN WIND-BORNE DEBRIS | | REGIONS SHALL HAVE GLAZED OPENINGS PROTECTED FROM | | WIND-BORNE DEBRIS OR THE BUILDING SHALL BE DESIGNED AS | | A PARTIALLY ENCLOSED BUILDING IN ACCORDANCE WITH THE | | FLORIDA BUILDING CODE, BUILDING . GLAZED OPENING | | PROTECTION FOR WIND-BORNE DEBRIS SHALL MEET THE | | REQUIREMENTS OF THE LARGE MISSILE TEST OF ASTM E 1996 | | AND OF ASTM E 1886, SSTD 12, ,OR TAS 201, 202 AND 203 | | REFERENCED THEREIN. | | | | 13) SHOW COMPLIANCE WITH R806.1 VENTILATION REQUIRED. | | ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE | | CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF | | RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE | | SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE | | ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE | | PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WITH 1 / 8 | | INCH (3.2 MM) MINIMUM TO ? INCH (6.4 MM) MAXIMUM | | OPENINGS. | | | | 14) SPECIFY THE LENGTH OF THE ROOF OVERHANG. SEE R320.7 | | PROTECTION AGAINST TERMITES AND DECAY. CONDENSATE LINES | | AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1 FOOT | | AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY | | UNDERGROUND PIPING, TAIL EXTENSIONS OR SPLASH BLOCKS. | | GUTTERS WITH DOWN SPOUTS ARE REQUIRED ON ALL BUILDINGS | | WITH EAVES OF LESS THAN 6 INCHES HORIZONTAL PROJECTION | | EXCEPT FOR GABLE END RAKES OR ON A ROOF ABOVE ANOTHER | | ROOF. | | | | 15) PROVIDE STRUCTURAL DETAILS OF THE EXISTING PORCH, | | PART OF WHICH IS BEING ENCLOSED. | | | | 16) THE WRONG ENERGY CALC. FORMS WERE SUBMITTED. PLEASE | | SUBMIT THE 2004 FORMS # 600C-04 . THE OWNER/AGENT IS | | REQUIRED TO SIGN THE ENERGY CALC. FORM. SEE FBC CHAPTER | | 13. | | | | 17) SPECIFY THE ROOF SHEATHING FASTENER SPACING.ROOF | | SHEATHING IS REQUIRED TO BE IN ACCORDANCE WITH SECTION | | R803.2.3.1 OF 2006 REVISIONS TO 2004 FBC RESIDENTIAL | | CODE. WOOD STRUCTURAL PANEL SHEATHING SHALL BE FASTENED | | TO ROOF FRAMING WITH 8D RING-SHANK NAILS AT 6 INCHES ON | | CENTER AT EDGES AND 6 INCHES ON CENTER AT INTERMEDIATE | | FRAMING. SPACING OF RING-SHANK FASTENERS SHALL BE 4 | | INCHES ON CENTER IN NAILING ZONE 3 FOR 130 MPH OR | | GREATER DESIGNWIND SPEEDS IN ACCORDANCE WITH FIGURE | | R803.2.3.1. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2008-01-07 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-01-07 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-01-07 |
Time |
12:49 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2007-11-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-11-21 |
Time |
07:32 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-11-21 |
Time |
06:47 |
Sent To |
B |
|
Notes |
2007-11-21 07:32:21 | | | | | REVISION DENIED/INCOMPLETE INFORMATION | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | NONCOMPLIANT WITH THE FOLLOWING: | | | | 1} SHEET E-1 IS INCOMPLETE. THE WORK ORIGINALLY | | PERMITTED IS NOT SHOWN. THIS SHEET CANNOT BE REPLACED | | WITH A PARTIAL. 106.1.1 FBC AS AMENDED. INFORMATION ON | | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | ELECTRONIC MEDIA DOCUMENTS ARE PERMITTED TO BE | | SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL (SEE ALSO SECTION 106.3.5). | | | | 2} THE VALUE OF THE ADDITIONAL WORK MUST BE ADDED TO | | THE ORIGINAL FEES. ADJUST THE VALUE AT THE PERMIT | | CLERK?S DESK, AND PAY THE DIFFERENCE IN FEES PRIOR TO | | RESUBMITTING. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-06-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-06-04 |
Time |
13:32 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2007-06-04 |
Time |
12:53 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-04-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-04-25 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-04-25 |
Time |
12:30 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2007-03-06 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-03-06 |
Time |
16:23 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2007-03-06 |
Time |
16:12 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2008-01-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-30 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-30 |
Time |
12:33 |
Sent To |
Z |
|
Notes |
2008-01-30 12:33:42 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2008-01-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-04 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-04 |
Time |
16:43 |
Sent To |
E |
|
Notes |
2008-01-04 16:43:25 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2007-11-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-15 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-15 |
Time |
09:10 |
Sent To |
E |
|
Notes |
2007-11-15 09:11:16 | TO "BTROBAUGH" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2007-07-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-10 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-10 |
Time |
10:36 |
Sent To |
B |
|
Notes |
2007-07-10 10:36:44 | TO "RMCDOUGAL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-06-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-01 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-01 |
Time |
08:17 |
Sent To |
E |
|
Notes |
2007-06-01 08:17:54 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-05-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-22 |
Time |
16:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-22 |
Time |
16:23 |
Sent To |
|
|
Notes |
2007-05-22 16:24:59 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-04-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-20 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-20 |
Time |
14:29 |
Sent To |
E |
|
Notes |
2007-04-20 14:29:39 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-04-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-16 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-16 |
Time |
16:15 |
Sent To |
Z |
|
Notes |
2007-04-16 16:15:25 | TO "Z" BOX/RESUB--NEW SHEETS FOR "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-22 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-22 |
Time |
13:56 |
Sent To |
E |
|
Notes |
2007-02-22 13:57:52 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-03-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-03-29 |
Time |
07:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-02-14 |
Time |
15:19 |
Sent To |
|
|
Notes |
2007-02-14 15:27:24 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2007-03-07 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-03-07 |
Time |
13:41 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2007-03-07 |
Time |
13:41 |
Sent To |
P |
|
Notes |
2007-03-07 13:42:06 | NO MECHANICAL PLANS SUBMITTED, AND NO | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | THIS TIME. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2008-01-08 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-08 |
Time |
14:35 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-08 |
Time |
14:35 |
Sent To |
B |
|
Notes |
2008-01-08 14:37:00 | REVISION: SHEET E-1, SANITARY ISOMETRIC RISER DIAGRAM. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-06-14 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-06-14 |
Time |
11:35 |
Rev Time |
0.20 |
Received By |
mperson |
Date |
2007-06-14 |
Time |
11:35 |
Sent To |
B |
|
Notes |
2007-06-14 11:36:35 | NOTE: NEW SHEET. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2007-04-25 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-04-25 |
Time |
14:26 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2007-04-25 |
Time |
14:26 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-03-09 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-03-09 |
Time |
10:06 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2007-03-09 |
Time |
10:06 |
Sent To |
B |
|
Notes |
2007-03-09 11:16:14 | DENIED | | REFERENCE: FBC-2004 PLUMBING; FBC-2004 CHAPTER 1, CITY | | OF WEST PALM BEACH AMENDMENTS; | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1. FBC-2004 CHAPTER 1, SECTION 106.1.1 INFORMATION ON | | CONSTRUCTION | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | BE OF SUFFICIENT CLARITY TO INDICATE THE | | LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE | | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, | | AS DETERMINED BY THE | | BUILDING OFFICIAL. | | NOTE: SHEET E-1 ISOMETRIC SANITARY RISER DIAGRAM DOES | | NOT REFLECT THE FLOOR PLAN ON SHEET A-1. SHEET A-1 | | INDICATES A NEW KITCHEN WITH A DOUBLE BOWL KITCHEN SINK | | WITH DISHWASHER BUT ON SHEET E-1 ISOMETRIC SANITARY | | RISER DIAGRAM THE WASTE PIPING TO THE NEW KITCHEN IS | | NOT INDICATED. PLEASE REFERENCE THE ATTACHED CORRECTED | | ISOMETRIC SANITARY RISER DIAGRAM TO THE PLUMBING | | COMMENTS THAT REFLECTS THE FLOOR PLAN AND IS CODE | | COMPLIANT FOR THE RESUBMITTAL. | | | | ********IMPORTANT INFORMATION | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | TRANSMITTAL LETTER INDICATING HOW EACH | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
F |
Date |
2008-02-01 |
|
|
Cont ID |
|
Sent By |
adavila |
Date |
2008-02-01 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
adavila |
Date |
2008-01-30 |
Time |
17:13 |
Sent To |
B |
|
Notes |
2008-02-01 13:15:56 | PLANNING AND ZONING DEPARTMENT | | | | ***FAILED*** | | | | 1. THE DIMENSIONS SHOWN ON THE SURVEY SUBMITTED WITH | | THIS REVISION DO NOT MATCH THE DIMENSIONS SHOWN ON THE | | PREVIOUSLY SUBMITTED SURVEY.PLEASE CLARIFY. | | | | 2. REPEAT COMMENT - SETBACK DIMENSIONS SHOWN ON THE | | SITE PLAN DO NOT MATCH THE SETBACK DIMENSIONS SHOWN ON | | THE SURVEY.SETBACK DIMENSIONS WERE REDLINED ON THE | | SITE PLAN OF THE APPROVED PERMIT. | | | | 3. THERE IS A DISCREPANCY BETWEEN THE ROOF OVERHANG | | DIMENSION SHOWN ON THE SURVEY AND THE OVERHANG | | DIMENSION SHOWN ON THE PLANS.PLEASE CLARIFY.PROVIDE | | THE ROOF OVERHANG DIMENSION OF THE EXISTING CARPORT. | | | | 4. ACCORDING TO THE RESUBMITTED PACKET, THE WORK VALUE | | INCREASED BY $15,000.PER SECTION 94-441(C)(2), | | ALTERATIONS WHICH EXCEED 50% OF THE VALUE OF THE | | STRUCTURE SHALL COMPLY WITH ARTICLE XIV OF THE ZONING | | AND LAND DEVELOPMENT REGULATIONS.PLEASE NOTE IN THE | | EVENT THAT THE WORK VALUE INCREASES AGAIN. | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
F |
Date |
2008-01-15 |
|
|
Cont ID |
|
Sent By |
adavila |
Date |
2008-01-15 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
adavila |
Date |
2008-01-11 |
Time |
17:06 |
Sent To |
I |
|
Notes |
2008-01-15 10:55:48 | PLANNING AND ZONING DEPARTMENT | | | | ***FAILED*** | | | | 1. REPEAT COMMENT - PROVIDE 2 COPIES OF A CURRENT | | SURVEY.SURVEY SHALL SHOW WIDTH, DEPTH AND SETBACK | | DIMENSIONS OF THE EXISTING CARPORT, AS WELL AS SETBACK | | DIMENSIONS OF THE EXISTING STRUCTURE. | | A. SURVEY DOES NOT SHOW DIMENSIONS OF THE EXISTING | | CARPORT, INCLUDING ROOF OVERHAND PROJECTIONS. | | B. ONLY 1 COPY OF THE SURVEY WAS SUBMITTED WITH THIS | | APPLICATION. | | | | 2. REPEAT COMMENT - PROVIDE 2 COPIES OF A SITE PLAN | | SHOWING ALL SETBACK DIMENSIONS OF THE EXISTING | | STRUCTURE AND THE PROPOSED GARAGE. | | A. SETBACK DIMENSIONS DO NOT MATCH THE SETBACK | | DIMENSIONS SHOWN ON THE SURVEY. | | B. SETBACK DIMENSIONS TO THE PROPOSED GARAGE ARE NOT | | SHOWN ON THE SITE PLAN. | | | | 3. PROVIDE ROOF OVERHAND DIMENSION ALONG THE NORTH AND | | WEST BUILDING FA?ADES OF THE GARAGE.PLEASE NOTE THAT | | ROOF OVERHANGS MAY NOT PROJECT FURTHER THAN 3 FEET INTO | | A SETBACK, OR FURTHER THAN THE EXISTING ROOF OVERHANG | | PROJECTION. | | | | 4. REAR ELEVATION DOES NOT MATCH PROPOSED PLANS. | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2007-11-28 |
|
|
Cont ID |
|
Sent By |
adavila |
Date |
2007-11-28 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
adavila |
Date |
2007-11-28 |
Time |
13:41 |
Sent To |
I |
|
Notes |
2007-11-28 14:22:00 | PLANNING AND ZONING DEPARTMENT | | | | ***FAILED*** | | | | 1.PROVIDE 2 COPIES OF A CURRENT SURVEY.SURVEY SHALL | | SHOW WIDTH, DEPTH AND SETBACK DIMENSIONS OF THE | | EXISTING CARPORT, AS WELL AS SETBACK DIMENSIONS OF THE | | EXISTING STRUCTURE. | | | | 2.PROVIDE 2 COPIES OF A SITE PLAN SHOWING ALL SETBACK | | DIMENSIONS OF THE EXISTING STRUCTURE AND THE PROPOSED | | GARAGE. | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-05-30 |
|
|
Cont ID |
|
Sent By |
adavila |
Date |
2007-05-30 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
adavila |
Date |
2007-05-23 |
Time |
15:41 |
Sent To |
I |
|
Notes |
2007-05-30 13:04:30 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-04-18 |
|
|
Cont ID |
|
Sent By |
adavila |
Date |
2007-04-18 |
Time |
18:27 |
Rev Time |
0.00 |
Received By |
adavila |
Date |
2007-04-17 |
Time |
08:55 |
Sent To |
Z |
|
Notes |
2007-04-18 18:27:29 | PLANNING AND ZONING DEPARTMENT | | | | ***FAILED*** | | | | 1. PROVIDE ALL SETBACK DIMENSIONS FROM PROPERTY LINE ON | | SITE PLAN (REPEAT COMMENT). | | A. SETBACK DIMENSIONS TO THE WEST PROPERTY LINE ARE NOT | | SHOWN ON SITE PLAN. | | | | 2. SETBACK DIMENSIONS ON SITE PLAN DO NOT MATCH THOSE | | INDICATED ON THE SURVEY. | | A. ACCORDING TO THE SURVEY THE EXISTING STRUCTURE HAS A | | 7.15 FOOT SETBACK TO THE EAST PROPERTY LINE AT THE | | FRONT OF THE HOUSE.SITE PLAN SHOWS A 6.5 FOOT | | SETBACK. | | | | 3. PURSUANT TO SECTION 94-72 OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS, MINIMUM SIDE SETBACK IS 5 | | FEET, 15 FEET TOTAL.NEW GARAGE ADDITION SHALL MEET | | THIS REQUIREMENT. | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-02-22 |
|
|
Cont ID |
|
Sent By |
adavila |
Date |
2007-02-22 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
adavila |
Date |
2007-02-22 |
Time |
08:43 |
Sent To |
I |
|
Notes |
2007-02-22 08:43:57 | PLANNING AND ZONING DEPARTMENT | | | | ***FAILED*** | | | | 1. PLEASE PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | | 2. PROVIDE TWO (2) SIGNED AND SEALED SURVEYS.THE | | SURVEY SHALL BE LESS THAN A YEAR OLD. | | | | 3. PROVIDE DIMENSION BETWEEN PROPOSED ADDITION AND | | EXISTING ACCESSORY STRUCTURE. | | | | 4. PROVIDE ALL SETBACK DIMENSIONS FROM PROPERTY LINE ON | | SURVEY AND SITE PLAN. | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA OR ERIC | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|