Plan Review Stops For Permit 07020350 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2007-03-20 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-03-20 |
Time |
12:37 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2007-03-20 |
Time |
12:36 |
Sent To |
PC |
|
Notes |
2007-03-20 12:37:22 | OK PER BUILDING PLAN REVIEW L.MARTINEZ./WRT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-04-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-04-23 |
Time |
13:44 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2007-04-23 |
Time |
12:49 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-03-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-03-01 |
Time |
16:42 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2007-03-01 |
Time |
16:37 |
Sent To |
M |
|
Notes |
2007-03-01 16:41:53 | | | DENIED/INCOMPLETE INFORMATION | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} PROVIDE A LOAD CALCULATION FOR THE | | LOAD INTENDED TO BE SERVED. 215.5. | | | | 2} PROVIDE A PANEL SCHEDULE FOR THE | | GENERATOR PANEL. 106.3.5.4 FBC AS | | AMMENDED. | | | | THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2007-04-24 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-04-24 |
Time |
08:09 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2007-04-24 |
Time |
08:09 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2007-03-13 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-03-13 |
Time |
11:11 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2007-03-13 |
Time |
11:11 |
Sent To |
B |
|
Notes |
2007-03-13 11:21:00 | DENIED | | REFERENCE: FBC-2004 FUEL GAS; CITY OF WEST PALM BEACH, | | GAS PERMIT APPLICATION REQUIREMENTS AND RESIDENTIAL | | GENERATOR PERMIT APPLICATION REQUIREMENTS; | | | | THE FOLLOWING INFORMATION IS REQUIRED FOR GAS PLAN | | REVIEW TO MEET CODE COMPLIANCE: | | | | 1. PLEASE SUBMIT 2 COPIES OF MANUFACTURER'S | | SPECIFICATIONS/CUT SHEETS FOR GENERATOR SHOWING | | LISTINGS FROM A NATIONALLY RECOGNIZED TESTING | | LABORATORY (NRTL) AND VERIFICATION OF GENERATOR BTU,S. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-04-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-09 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-09 |
Time |
13:49 |
Sent To |
E |
|
Notes |
2007-04-09 13:49:33 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-02-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-26 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-26 |
Time |
08:40 |
Sent To |
E |
|
Notes |
2007-02-26 08:40:33 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-03-20 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-03-20 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-02-15 |
Time |
13:31 |
Sent To |
PC |
|
Notes |
2007-02-15 13:32:05 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2007-03-02 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-03-02 |
Time |
09:39 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2007-03-02 |
Time |
09:39 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2007-02-22 |
|
|
Cont ID |
|
Sent By |
adavila |
Date |
2007-02-22 |
Time |
12:53 |
Rev Time |
0.00 |
Received By |
adavila |
Date |
2007-02-22 |
Time |
12:53 |
Sent To |
I |
|
Notes |
2007-02-22 12:53:24 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. |
|
|