Plan Review Stops For Permit 07020267 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-05-24 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2007-05-24 |
Time |
|
Sent To |
|
|
Notes |
2007-04-10 11:03:14 | THE ADDRESS ON THE SUBMITTED APPLICATION (600 NO. | | DIXIE)DOES NOT MATCH THE SITE PLAN LOCATION (600 SO. | | DIXIE). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2008-12-01 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-12-01 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-12-01 |
Time |
07:53 |
Sent To |
|
|
Notes |
2008-12-01 07:53:16 | REVISION TO SHEETS #1 & 2. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-09-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-09-05 |
Time |
15:38 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2008-09-05 |
Time |
15:38 |
Sent To |
|
|
Notes |
2008-09-05 15:39:15 | REVISION # & 6 SHEET 1& 2 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-05-12 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2008-05-12 |
Time |
07:47 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2008-05-03 |
Time |
07:10 |
Sent To |
|
|
Notes |
2008-05-12 07:47:12 | BUILDING PLAN REVIEW | | PERMIT: 07020267 | | ADD: 600 S.DIXIE HWY | | CONT: AMERICA HOME CARE. | | TEL: (954)646-2283 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2007 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW: REVISION | | ACTION: DENIED | | | | 1) 61G1-18.002PROCEDURES FOR A SUCCESSOR ARCHITECT | | ADOPTING AS HIS OWN THE WORK OF ANOTHER ARCHITECT. (1) | | A SUCCESSOR REGISTERED ARCHITECT SEEKING TO REUSE | | ALREADY SEALED CONTRACT DOCUMENTS UNDER THE SUCCESSOR | | REGISTERED ARCHITECT'S SEAL MUST BE ABLE TO DOCUMENT | | AND PRODUCE UPON REQUEST EVIDENCE THAT HE HAS IN FACT | | RECREATED ALL THE WORK DONE BY THE ORIGINAL REGISTERED | | ARCHITECT. FURTHER, THE SUCCESSOR REGISTERED ARCHITECT | | MUST TAKE ALL PROFESSIONAL AND LEGAL RESPONSIBILITY FOR | | THE DOCUMENTS WHICH HE SEALED AND SIGNED AND CAN IN NO | | WAY EXEMPT HIMSELF FROM SUCH FULL RESPONSIBILITY. PLANS | | NEED NOT BE REDRAWN BY THE SUCCESSOR REGISTERED | | ARCHITECT; HOWEVER, JUSTIFICATION FOR SUCH ACTION MUST | | BE AVAILABLE THROUGH WELL KEPT AND COMPLETE | | DOCUMENTATION ON THE PART OF THE SUCCESSOR REGISTERED | | ARCHITECT AS TO HIS HAVING RETHOUGHT AND REWORKED THE | | ENTIRE DESIGN PROCESS. A SUCCESSOR REGISTERED ARCHITECT | | MUST USE HIS OWN TITLE BLOCK, SEAL AND SIGNATURE AND | | MUST REMOVE THE TITLE BLOCK, SEAL AND SIGNATURE OF THE | | ORIGINAL REGISTERED ARCHITECT BEFORE SEALING, SIGNING | | AND DATING ANY SEALED CONTRACT DOCUMENTS. | | (2) PRIOR TO SEALING, SIGNING AND DATING WORK, A | | SUCCESSOR REGISTERED ARCHITECT SHALL BE REQUIRED TO | | NOTIFY THE ORIGINAL REGISTERED ARCHITECT, HIS | | SUCCESSORS, OR ASSIGNS BY CERTIFIED LETTER TO THE LAST | | KNOWN ADDRESS OF THE ORIGINAL REGISTERED ARCHITECT OF | | THE SUCCESSOR'S INTENTION TO USE OR REUSE THE ORIGINAL | | REGISTERED ARCHITECT'S WORK. THE SUCCESSOR REGISTERED | | ARCHITECT WILL TAKE FULL RESPONSIBILITY FOR THE DRAWING | | AS THOUGH THEY WERE THE SUCCESSOR REGISTERED | | ARCHITECT'S ORIGINAL PRODUCT. | | | | 2)UNLESS THE NEW ARCHITECT IS TAKING OVER THE PROJECT | | HE CANNOT MAKE ANY CHANGES TO THE DRAWINGS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | (561)805-6726 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-05-24 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-05-24 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-05-24 |
Time |
09:16 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-04-03 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-04-03 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-03-31 |
Time |
10:51 |
Sent To |
PC |
|
Notes |
2007-03-31 11:22:37 | BUILDING PLAN REVIEW | | PERMIT: | | ADD: | | CONT: | | TEL: (561)###-#### | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 2ND | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | THE COURT. | | NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3)OK | | | | 4)OK | | | | 5) OK | | | | 6)FBC 11-7.2(2) (I) A PORTION OF THE MAIN COUNTER | | WHICH IS A MINIMUM OF 36 INCHES IN LENGTH SHALL BE | | PROVIDED WITH A MAXIMUM HEIGHT OF 36 INCHES.IN NEW | | CONSTRUCTION, WHERE THE SELLING SPACE IS UNDER 5,000 | | SQUARE FEET, ONLY ONE CHECK-OUT AISLE IS REQUIRED TO BE | | ACCESSIBLE. SHOW COMPLIANCE WITH ELEVATION DRAWINGS. | | | | 6A)11-2.2 EQUIVALENT FACILITATION. | | DEPARTURES FROM PARTICULAR TECHNICAL AND SCOPING | | REQUIREMENTS OF THIS CODE BY THE USE OF OTHER DESIGNS | | AND TECHNOLOGIES ARE PERMITTED WHERE THE ALTERNATIVE | | DESIGNS AND TECHNOLOGIES USED WILL PROVIDE | | SUBSTANTIALLY EQUIVALENT OR GREATER ACCESS TO AND | | USABILITY OF THE FACILITY. SHOW THE WHEELCHAIR TURNING | | SPACE IN OFFICE #2. SEE FBC.CH.11 FIG #3. | | | | 7)FBC.11-5.2 WHERE FOOD OR DRINKIS SERVED AT | | COUNTERS EXCEEDING 34 INCHES IN HEIGHT FOR CONSUMPTION | | BY COUSTOMERS SEATED ON STOOLS OR STANDING AT THE | | COUNTER, A PORTION OF THE MAIN COUNTERWHICH IS60 | | INCHES IN LENGTH MINIMUM SHALL BE PROVIDED IN | | COMPLIANCE WITH SECTION 11-4.32 OR SERVICES SHALL BE | | AVAILABLE AT TABLES WITHIN THE SAME AREA. | | | | 7A)FBC. 11-4.33.3AT LEAST ONE COMPANION FIXED SEAT | | SHALL BE PROVIDED NEXT TO EACH WHEEL CHAIR SEATING | | AREA. SHOW COMPLIANCE WITH ELEVATION DRAWINGS. ALSO | | SHOW THE ELEVATION DETAILS OF THE TABLE PROVIDED. SEE | | FIG.45. | | | | | | 8)OK | | | | 9)SHOWER STALLS SHALL COMPPLY WITH SECTION 11-4.21 | | PROVIDE AN ELEVATION DRAWINGS WITH ALL THE | | DIMENTIONS............ | | OK, BUT SHOWER #2 IS MISSING THE DIMENTIONS. COMPLY AND | | SHOW DIMENTIONS. ALSO INDICATE THE TYPE OF | | MATERIALWHICH WILL BE USED FOR THE GRAB BARS BACKING | | AND THE 250 LBSREQUIREMENT OF SECTION 11-4.26.3. | | | | 10)OK | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-02-16 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-02-16 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-02-15 |
Time |
15:21 |
Sent To |
|
|
Notes |
2007-02-15 16:31:20 | BUILDING PLAN REVIEW | | PERMIT: | | ADD: | | CONT: | | TEL: (561)###-#### | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2)FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | THE COURT. | | NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3)110.2* W. P. B. ADMINISTRATIVE | | CODE, INFORMATION THAT IS REQUIRED FOR | | RECORD KEEPING & FOR CERTIFICATE OF | | OCCUPANCY: | | A) THE EDITION OFTHE CODE UNDER WHICH | | THE PERMIT WAS ISSUED. FBC 2004 WITH 2006 REVISIONS | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | WITH THE PROVISIONS OF CHAPTER 3. | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | IN CHAPTER 6, TABLE 601. | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | IS REQUIRED. | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | OF THE BUILDING PERMIT. | | ------------------------------------- | | ) NUMBER OF UNITS | | ) NUMBER OF FLOORS | | ) NUMBER OF ROOMS | | ) SQ. FT. FOOTPRINT | | ) SQ. FT. UNDER ROOF (TOTAL) | | ) OCCUPANT LOAD | | ) FLOOD ZONE | | ) FLOOD ELEVATION | | )L.O.M.R. | | | | 4)THE VALUE ON THE APPLICATION IS LOW.108.3*IF, | | IN THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED | | VALUATION OF BUILDING, ALTERATION. STRUCTURE, | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | PLUMBING, MECHANICAL, INTERIOR FINISH, ARCHITECTURAL | | AND DESIGN FEES, MARKETING COST, OVERHEAD AND PROFIT; | | EXCLUDING LAND ONLY. OUR VALUATION REFERENCE IS ICC | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS | | SERVICES. | | | | 5)FBC 106.3.5.1.1SUBMIT A LIFE SAFETY PLAN SHOWING | | THE MEANS OF EGRESS AND TRAVEL DISTANCE. IS THERE A | | SPRINKLER SYSTEM IN THIS AREA?CLARIFY. | | | | 6)FBC 11-7.2(2) (I) A PORTION OF THE MAIN COUNTER | | WHICH IS A MINIMUM OF 36 INCHES IN LENGTH SHALL BE | | PROVIDED WITH A MAXIMUM HEIGHT OF 36 INCHES.IN NEW | | CONSTRUCTION, WHERE THE SELLING SPACE IS UNDER 5,000 | | SQUARE FEET, ONLY ONE CHECK-OUT AISLE IS REQUIRED TEO | | BE ACCESSIBLE. SHOW COMPLIANCE WITH ELEVATION | | DRAWINGS. | | | | 7)FBC.11-5.2 WHERE FOOD OR DRINKIS SERVED AT | | COUNTERS EXCEEDING 34 INCHES IN HEIGHT FOR CONSUMPTION | | BY COUSTOMERS SEATED ON STOOLS OR STANDING AT THE | | COUNTER, A PORTION OF THE MAIN COUNTERWHICH IS60 | | INCHES IN LENGTH MINIMUM SHALL BE PROVIDED IN | | COMPLIANCE WITH SECTION 11-4.32 OR SERVICES SHALL BE | | AVAILABLE AT TABLES WITHIN THE SAME AREA. | | | | 8)CLARIFY IF THE BUILDING OR NEW SPACE HAS A | | SPRINKLER SYSTEM, AND IF IT DOES, STATE THE TYPE OF | | SPRINKLER SYSTEM ON THE DRAWINGS. SEE SHEET 1. | | | | 9)SHOWER STALLS SHALL COMPPLY WITH SECTION 11-4.21 | | PROVIDE AN ELEVATION DRAWINGS WITH ALL THE DIMENTIONS. | | | | 10)FBC 1210.3 SHOWER COMPARTMENTS AND WALLS ABOVE | | BATHBUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED | | WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT | | LESS THAN 70 INCHES ABOVE THE DRAIN INLET. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2008-12-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-12-05 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-12-05 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2008-09-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-09-16 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-09-16 |
Time |
10:21 |
Sent To |
|
|
Notes |
2008-09-16 14:23:54 | | | | | NONCOMPLIANT/ REVISION DENIED | | | | ALL COMMENTS RELATE TO SHEET #2, UNLESS OTHERWISE | | NOTED. SEE REVIEWED SET FOR SOME, BUT NOT ALL, EXAMPLES | | OF NONCOMPLIANCE. | | | | 1} THE "EM" FIXTURES MUST BE CIRCUITED PER 700.12 NEC | | (F)(4). THE ADDED "EM" LIGHTS AND SOME MISSED ON | | PREVIOUS REVIEW, EXIT AND EMERGENY, DO NOT COMPLY. | | | | 2} THERE ARE SEVERAL MOTION SENSORS THAT HAVE BEEN | | REMOVED AND WERE NOT INDICATED AS A REVISION (CLOUDED) | | ON THE PLAN. INDICATE HOW COMPLIANCE WITH | | 13-415.1.ABC.1.2 SPACE CONTROL, IS TO BE ACHIEVED, OR | | INSTALL, THE PERMITTED DETECTORS | | | | 3} THERE ARE CHANGES IN TYPE "I" AND "J" FIXTURES AND | | ADDITIONS OF TYPE "H", "L", "M", AND "N" FIXTURES. IT | | IS NOT CLEAR HOW THE MAXIMUM WATTAGES STILL COMPLY WITH | | 13-415.2B FBC AS STATED IN THE NOTE ON SHEET | | #4,THEREFORE THE FOLLOWING IS REQUIRED: | | | | THE INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR | | A SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | SHALL BE DETERMINED BY EITHER THE BUILDING AREA METHOD | | DESCRIBED IN SECTION 415.2.C.1 OR THE SPACE-BY-SPACE | | METHOD DESCRIBED IN SECTION 415.2.B.1. THE INSTALLED | | INTERIOR LIGHTING POWER IDENTIFIED IN ACCORDANCE WITH | | SECTION 415.2.ABC.1.1 SHALL NOT EXCEED THE INTERIOR | | LIGHTING POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH | | SECTION 415.2.C.1 OR 415.2.B.1. THIS CAN BE | | DEMONSTRATED ON THE PLANS INDICATING THE WATTAGES OF | | THE LUMINAIRES CHOSEN FOR THE PROJECT CONFORM TO THE | | DENSITY REQUIREMENTS. INDICATE WATTAGES ON THE FIXTURE | | SCHEDULE AND SQUARE FOOTAGE FOR EACH ARE IN COMPLIANCE | | THE WITH WATTAGE ALLOWANCE*** NOTE : OFFICE AREAS ARE | | NOT ALLOWED 1.5 WATTS PER SQUARE FOOT. | | | | 4} ADD THE COST OF THE ADDITIONAL LABOR, MATERIAL AND | | EQUIPMENT ADDED IN THIS REVISION TO THE ORIGINAL VALUE | | ON THE APPLICATION ADJUST THE VALUE AT THE PERMIT | | CLERK?S DESK, AND PAY THE DIFFERENCE IN FEES PRIOR TO | | RESUBMITTING. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2008-05-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-05-22 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-05-22 |
Time |
16:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-04-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-04-09 |
Time |
12:24 |
Rev Time |
0.10 |
Received By |
btrobaug |
Date |
2007-04-09 |
Time |
07:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2007-02-13 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-02-13 |
Time |
13:27 |
Rev Time |
1.00 |
Received By |
btrobaug |
Date |
2007-02-13 |
Time |
07:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
6 |
Status |
P |
Date |
2008-12-02 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-12-02 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-12-02 |
Time |
14:35 |
Sent To |
|
|
Notes |
2008-12-02 14:48:27 | ***** REVISION #7, DATED 11/07/2008, APPROVED***** | | | | | | REVISED SHEETS 1, 2, & 4 WERE STAMPED INITIALED AND | | DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIORE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
F |
Date |
2008-09-22 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-09-22 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-09-22 |
Time |
13:41 |
Sent To |
|
|
Notes |
2008-09-22 13:48:13 | *****PROVISO***** | | | | | | REVISED SHEET 1 STAMPED, INITIALED, AND DATED; HOWEVER | | REVISED PLAN SHEETS 2 & 4 TO BE FIRE-STAMPED WHEN THE | | ELECTRICAL PLAN REVIEW COMMENT(S) HAVE BEEN SATISFIED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIORE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
F |
Date |
2008-05-12 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-05-12 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-05-12 |
Time |
12:56 |
Sent To |
|
|
Notes |
2008-05-12 13:03:04 | *****PROVISO***** | | | | | | REVISED SHEETS 1 AND 2 TO BE FIRE-STAMPED WHEN THE | | BUILDING REVIEW COMMENT(S) HAVE BEEN SATISFIED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2007-05-10 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-05-10 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-05-10 |
Time |
12:25 |
Sent To |
|
|
Notes |
2007-05-10 12:32:53 | *****APPROVED***** | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | BEEN ADDRESSED; PLAN SHEETS 2 AND 4 WERE STAMPED, | | INITIALED, AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2007-04-10 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-04-10 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-04-10 |
Time |
10:20 |
Sent To |
|
|
Notes |
2007-04-10 10:45:05 | *****UNSAT***** | | | | | | 03.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS | | SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT | | OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | ACKNOWLEDGE ON THE APPROPIATE PLAN SHEET | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2007-02-22 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-02-22 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-02-22 |
Time |
12:23 |
Sent To |
AD |
|
Notes |
2007-02-22 18:47:47 | *****DENIED***** | | | | | | 01.THE ACTUAL ADDRESS OF WHERE THE SCOPE OF WORK WILL | | BE CONDUCTED SHALL BE IN THE TITLE BLOCK OF EACH | | SUBMITTED PLAN SHEET.THE CORRECT ADDRESS FOR THIS | | LOCALE IS 600 SOUTH DIXIE HIGHWAY - SUITE 103. | | | | 02.ON SHEET 1, THE MENTIONED CODE OF 2003 NFPA 101 IS | | CORRECT.HOWEVER, ROOM FINISH NOTE #8INCORRECTLY | | REFERENCES 2005 NFPA 101. | | | | 03.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS | | SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT | | OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | 04.THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF | | NEW BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE | | OR HINDER WITH EMERGENCY ACCESS RESPONSE TO THE | | STRUCTURE OR THE VICINITY THEREOF (INCLUDING FIRE | | LANES). | | | | 05.PROVIDE A LIFE SAFETY PLAN SHEET WHICH INDICATES | | THE TRAVEL DISTANCE TO THE EXITS. THIS SHEET MAY ALSO | | INCLUDE THE LOCATION OF EXIT LIGHTS, EMERGENCY LIGHTS, | | FIRE EXTINGUISHERS,FIRE ALARM DEVICES, AND FIRE | | SPRINKLERS APPLICABLE TO THE PROPOSED STRUCTURE. | | | | 06.SHOW/DISPLAY THESUITE NUMBER ON THE EXTERIOR | | ELEVATION SO THAT THIS TENANT SPACE IS DISTINGUISHABLE | | FROM THE OTHER SUITES.AS PER WEST PALM BEACH CODE, | | THOSE NUMBERS SHALL BE NO LESS THAN 3" IN HEIGHT AND NO | | LESS THAN 1" IN WIDTH. | | | | 07.IT IS NOTED ON SHEET 1 THAT DOOR #25 IS NOT A | | REQUIRED EXIT DOOR, HOWEVER SHEET 2 HAS IT LABELED AS | | AN EXIT DOOR.PLEASE EXPLAIN THIS DOOR AND WHERE IT | | WOULD LEAD PEOPLE. | | | | 08.IF SO EQUIPPED WITH A FIRE ALARM SYSTEM, WILL IT | | BE INDEPENDANT OR WILL IT BE TIED INTO THE PRADO | | CONDOMINIUM'S SYSTEM. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | SHEET INDICATING HOW/WHERE ON THE PLANS EACH COMMENT | | WAS ADDRESSED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-11-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-11-18 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-11-18 |
Time |
14:40 |
Sent To |
|
|
Notes |
2008-11-21 16:51:31 | TO "BOB"#13 | 2008-11-18 14:41:14 | WAITING FOR "BOB" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-08-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-08-25 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2008-08-25 |
Time |
10:08 |
Sent To |
|
|
Notes |
2008-09-11 09:12:58 | MOVED TO #9 | 2008-08-25 10:08:57 | TO "COMM" BD #5. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-05-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-05-21 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-05-21 |
Time |
10:17 |
Sent To |
|
|
Notes |
2008-05-21 10:17:23 | TO "BOB"#6 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-05-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-02 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-02 |
Time |
15:03 |
Sent To |
|
|
Notes |
2007-05-02 15:05:48 | TO "BOB"#11 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-03-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-24 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-24 |
Time |
16:53 |
Sent To |
|
|
Notes |
2007-03-24 16:55:20 | TO "BOB"#3 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-02-22 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-02-12 |
Time |
16:54 |
Sent To |
|
|
Notes |
2007-02-12 16:57:14 | TO "BOB"#6 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2008-12-06 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-12-06 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-12-06 |
Time |
15:48 |
Sent To |
PC |
|
Notes |
2008-12-06 15:48:44 | REVISED M-1 AND M-2 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
F |
Date |
2008-09-09 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-09-09 |
Time |
08:07 |
Rev Time |
1.30 |
Received By |
tgordon |
Date |
2008-09-09 |
Time |
08:07 |
Sent To |
|
|
Notes |
2008-09-09 08:15:39 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | REVISION TO MECHANICAL PLANS M-1 AND M-2. | | *** DENIED *** | | | | 1) MECHANICAL PLAN M-2 EQUIPMENT SCHEDULE A/C SYSTEM #1 | | IS A 9.95 EER. PER 2004 FBC 13-407.1.ABC.3.2A (TABLE) | | THE MINIMUM EER IS 10.3 FOR THIS SIZE SYSTEM. PLEASE | | CORRECT. | | | | 2) THE COOLING LOAD CALCULATIONS WILL NEED TO BE | | REVISED AS THE COOLING ZONES HAVE CHANGED, PER 2004 FBC | | 13-407.1.ABC.1 AND 13-407.1.ABC.1.1. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2008-05-22 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-05-22 |
Time |
13:38 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2008-05-22 |
Time |
13:38 |
Sent To |
|
|
Notes |
2008-05-22 13:49:20 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | (F.S.). | | | | MECHANICAL REVISION PG. M-1 AND M-2. | | | | *** DENIED *** | | 1)A/C SYSTEM #1 MODEL NUMBERS (C/U 2TTA0072 A/H | | TWE063P13) LISTED ON THE A/C EQUIPMENT SCHEDULE COULD | | NOT BE FOUND ON THE ARI DIRECTORY WEB-SITE, PLEASE | | CORRECT OR SUBMIT AN ARI CERTIFICATE, SEE 2004 FBC | | 13-407.1.ABC.3.1.1. | | | | 2) FLEX DUCT FROM AC-1 TO 10X10 OUTSIDE AIR DUCT NEEDS | | TO BE SIZED, PER 2004 FBC/M 106.3.3. | | | | 3) PROVIDE OUTDOOR AIR CALCULATION, PER 2004 FBC/M | | 403.2. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729 | | E-MAIL; [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-05-03 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-05-03 |
Time |
09:27 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-05-03 |
Time |
09:27 |
Sent To |
|
|
Notes |
2007-05-03 09:33:17 | *** PROVISO *** | | 1) CLOTHES DRYER VENT MUST COMPLY WITH CLOTHES DRYER | | MANUFACTURER'S SPECIFICATION'S. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-03-29 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-03-29 |
Time |
11:23 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2007-03-29 |
Time |
11:23 |
Sent To |
|
|
Notes |
2007-03-29 11:34:24 | *** DENIED *** | | 1) IT HAS BEEN OBSERVED THAT MOST CLOTHES DRYER | | MANUFACTURES WILL NOT WARRANTY THEIR EQUIPMENT IF A | | BOOSTER FAN IS INSTALLED IN THE DRYER VENT, PLEASE | | PROVIDE A TECHNICAL SUBMITTAL FROM THE CLOTHES DRYER | | MANUFACTURE STATING THE WARRANTY WILL NOT BE VOIDED IF | | A BOOSTER FAN IS USED, PLEASE DO NOT PROVIDE | | INFORMATION FROM A SALES DEPARTMENT | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-02-15 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-02-15 |
Time |
13:40 |
Rev Time |
1.15 |
Received By |
tgordon |
Date |
2007-02-15 |
Time |
13:40 |
Sent To |
|
|
Notes |
2007-02-15 13:48:37 | *** DENIED *** | | 1) PLEASE SUBMIT COOLING LOAD CALCULATIONS, PER 2004 | | FBC 13-407.1.ABC.1. | | | | 2) AS THE CLOTHS DRYER VENT IS OVER 25 FEET, PLEASE | | SUBMIT DETAILED MANUFACTURER'S SPECIFICATION'S AND | | INSTALLATION INSTRUCTIONS FOR THE CLOTHS DRYER. | | | | 3) SEE MECHANICAL PLANS PAGE M-1, EF-5 NEEDS TO BE 50 | | CFM'S., SEE 2004 FBC/M TABLE 403.3 PUBLIC SPACES, | | SHOWER ROOM, PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
7 |
Status |
P |
Date |
2009-01-14 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2009-01-14 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2009-01-14 |
Time |
10:18 |
Sent To |
|
|
Notes |
2009-01-14 10:19:27 | REVISION OK- SHEET 3 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
F |
Date |
2008-12-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-12-01 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-12-01 |
Time |
12:11 |
Sent To |
|
|
Notes |
2008-12-01 12:17:11 | REVISION DENIED | | REFERENCE: FBC-2004 PLUMBING | | | | ****FROM PREVIOUS REVISION REVIEW: | | | | 1. OK | | 2. OK | | | | 3. SHT 3 OF 4. NEW FLOOR DRAIN IS INDICATED AS A FLOOR | | SINK ON THE FLOOR PLAN. A FLOOR SINK IS REQUIRED FOR | | INDIRECT WASTE. SECTION 802.3. FLOOR SINK SHALL CONNECT | | TO THE VENTED LINE PER SECTION 912.2.4, NOT TO THE | | BRANCH/FIXTURE LINE FOR THE OTHER FLOOR DRAIN IN SPA 2. | | A SEPARATE VENT FOR NEW FLOOR SINK WOULD ALSO WORK. | | SECTION 901.2.1. | | ****RESPONSE NOTED, BUT THE FLOOR PLAN AND SANITARY | | RISER DIAGRAM STILL SHOW THE DRAIN FOR THE ICE MACHINE | | AS A FLOOR DRAIN. A FLOOR SINK IS REQUIRED FOR INDIRECT | | WASTE. FLOOR DRAINS ARE NOT APPROVED INDIRECT WASTE | | RECEPTORS. | | | | ***********NEW COMMENT********** | | | | 1B. A RELIEF VENT IS REQUIRED FOR THE AIR ADMITTENCE | | VALVE INDICATED ON THE NEW S-4 SINK. SECTION 917.3.2. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2008-08-28 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-08-28 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-08-28 |
Time |
09:12 |
Sent To |
|
|
Notes |
2008-08-28 09:24:23 | REVISION DENIED | | REFERENCE: FBC-2004 PLUMBING | | | | 1. SHT 3 OF 4. A WATER HAMMER ARRESTOR IS REQUIRED ON | | THE WATER SUPPLY LINE TO THE ICE MAKER. SECTION 604.9 & | | PDI-WH 201. | | | | 2. SHT 3 OF 4. THE NEW S-4 SINK DRAIN SHALL NOT DRAIN | | THRU THE HORIZONTAL WET VENT FOR THE TOILET ROOM | | FIXTURES. ALL OTHER FIXTURES SHALL DISCHARGE DOWNSTREAM | | OF THE HORIZONTAL WET VENT. SECTION 909.1. SINK SHALL | | CONNECT DOWNSTREAM OF THE TOILET ROOM FIXTURES. | | | | 3. SHT 3 OF 4. NEW FLOOR DRAIN IS INDICATED AS A FLOOR | | SINK ON THE FLOOR PLAN. A FLOOR SINK IS REQUIRED FOR | | INDIRECT WASTE. SECTION 802.3. FLOOR SINK SHALL CONNECT | | TO THE VENTED LINE PER SECTION 912.2.4, NOT TO THE | | BRANCH/FIXTURE LINE FOR THE OTHER FLOOR DRAIN IN SPA 2. | | A SEPARATE VENT FOR NEW FLOOR SINK WOULD ALSO WORK. | | SECTION 901.2.1. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | ONE SET OF THEM LOOSELY ON TOP OF THE | | COLLATED PLANS TO BE REVIEWED. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2008-06-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2008-06-03 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2008-06-03 |
Time |
08:03 |
Sent To |
|
|
Notes |
2008-06-03 08:37:05 | REVISED RISER DIAGRAM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-05-09 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-05-09 |
Time |
07:15 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-05-09 |
Time |
07:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-03-31 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-03-31 |
Time |
07:34 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-03-31 |
Time |
07:34 |
Sent To |
|
|
Notes |
2007-03-31 07:50:40 | DENIED; | | 1. WATER RISER DIAGRAM; WATER HAMMER ARRESTORS ARE | | REQUIRED FOR ALL QUICK CLOSE VALVES ONLY. ONLY THE | | JUICE BAR SINK AND THE AUTOMATIC CLOTHES WASHER HAVE | | QUICK CLOSING VALVES. WATER HAMMER ARRESTORS TO BE | | INSTALLED PER MANUFATURE SPECIFICATIONS, AT THE BOTTOM | | OF THE DROPS NOT IN CEILING. | | 2.SANITARY RISER DIAGRAM; ADD DRINKING FOUNTAIN TO | | RISER DIAGRAM. | | 3. A THERMAL EXPANSION CONTROL IS REQUIRED AT WATER | | HEATER. SHOW OR MAKE A NOTE ON PLAN. SPEC TYPE AND SIZE | | TO BE INSTALLED. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-02-15 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-02-15 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-02-15 |
Time |
09:39 |
Sent To |
PC |
|
Notes |
2007-02-15 10:26:30 | DENIED; | | 1. PLUMBING FIXTURE SCHEDULE, TOILETS TO BE ELONGATED | | TYPE (NOT SURE OF MODEL NUMBER) AND SEAT TO BE OPEN | | FRONT. SEE FBC PLUMBING SECTIONS, 420.2 AND 420.3. | | 2. PLUMBING NOTE # 12; SEE SECTION 410.1. THE ONLY | | EXCEPTION FOR NOT INSTALLING A DRINKING FOUNTAIN IS FOR | | A RESTAURANT. DRINKING FOUNTAIN IS REQUIRED , SEE TABLE | | 403.1 (2B). | | 3. PLUMBING NOTE # 8; PVC PIPE CAN ONLY BE USED 5' INTO | | A BUILDING 605.3. SEE TABLE 605.4 FOR TYPE OF MATERIAL | | THAT CAN BE USED. | | 4. PAGE 1 FLOOR PLAN NOTE #16;SHOW A DETAIL WITH ALL | | REQUIRED MEASUREMENTS TO MEET HANDICAP REQUIREMENTS | | PER. FBC-2004 BUILDING CHAPTER 11. SEE SECTION | | 11-4.24.2 THRU 11-4.24.7. | | 5. SANITARY RISER DIAGRAM; | | A) AUTOMATIC CLOTHES WASHER BRANCH DRAIN TO | | BE 3" SECTION 406.3. | | B)FLOOR DRAIN IN WORK ROOM NOT VENTED AND | | SHOULD HAVE A TRAP PRIMER. | | C) F/D IN WOMAN'S ROOM NOT VENTED. | | D) F/D IN WOMAN'S SHOWER ROOM NOT VENTED. | | E) F/D IN MEN'S ROOM MISSING. | | F) F/D MEN'S SHOWER ROOM NOT VENTED. | | 6. WATER RISER DIAGRAM; AUTOMATIC CLOTHES WASHER | | REQUIRE WATER HAMMER ARRESTORS, TOBE INSTALLED PER | | MANUFACTURE INSTALLATION INSTRUCTIONS. SEE SECTION | | 604.9. | | PLUMBING PLAN REVIEW BY | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2008-09-05 |
|
|
Cont ID |
|
Sent By |
mflis |
Date |
2008-09-05 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
mflis |
Date |
2008-09-05 |
Time |
08:36 |
Sent To |
|
|
Notes |
|
|