Plan Review Details - Permit 07020234
Plan Review Stops For Permit 07020234 |
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-10-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-17 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-17 |
Time |
12:35 |
Sent To |
M |
|
Notes |
2007-10-17 12:36:30 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-04-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-25 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-25 |
Time |
13:02 |
Sent To |
M |
|
Notes |
2007-04-25 13:02:27 | TO "M" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-04-03 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-04-03 |
Time |
17:20 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-04-03 |
Time |
17:20 |
Sent To |
M |
|
Notes |
2007-04-03 17:20:47 | TO TOM GORDON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-02-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-02-16 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2007-02-09 |
Time |
16:52 |
Sent To |
|
|
Notes |
2007-02-09 16:53:35 | TO "M" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2007-10-23 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-10-23 |
Time |
09:34 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-10-23 |
Time |
09:34 |
Sent To |
|
|
Notes |
2007-10-23 09:35:29 | REVISION TO MECH. PLAN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-04-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-04-26 |
Time |
10:30 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-04-26 |
Time |
10:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-04-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-04-04 |
Time |
09:28 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-04-04 |
Time |
09:28 |
Sent To |
|
|
Notes |
2007-04-04 09:30:47 | *** DENIED *** | | **AS NOTED IN LAST REVIEW 2-16-07** | | | | 1) MECHANICAL PLANS THAT WERE SUBMITTED HAVE FADED | | INFORMATION (SEE ADDRESS AND EQUIPMENT LISTING) ON THEM | | AND SHOW THE SUPPLY AND RETURN AIR GRILLS AS STRAIGHT | | LINES, A STRAIGHT LINE IS NOT AN ACCEPTABLE SYMBOL FOR | | AN A/C GRILL. SEE 2004 FBC 106.1.1 INFORMATION ON | | CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE | | PERMITTED TO BE SUBMITTED WHEN APPROVED BY THE BUILDING | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | BY THE BUILDING OFFICIAL (SEE ALSO SECTION 106.3.5 ). | | | | 2) ALL RECORDS ARE ELECTRONICALLY SCANNED FOR RETENTION | | AND THE PLANS THAT WERE SUBMITTED ARE NOT ACCEPTABLE | | FOR RETENTION, SEE 2004 FBC CITY WPB AMEND. 106.1.3. | | | | 3) SEE YELLOW HIGH LIGHTS ON PLANS FOR MISSING | | INFORMATION AND FADED INFORMATION. | | | | 4) SEE ATTACHED NOTICE FS 553.80(2)(B) REGARDING FOUR | | TIMES THE FEE. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-02-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-02-16 |
Time |
14:16 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-02-16 |
Time |
14:16 |
Sent To |
|
|
Notes |
2007-02-16 14:28:44 | *** DENIED *** | | 1) PLEASE SUBMIT MECHANICAL PLANS THAT SHOW THE | | LOCATION OF THE SUPPLY AIR GRILLS, RETURN AIR GRILLS, | | A/C EQUIPMENT, AN EQUIPMENT LISTING(MAKE, MODEL, | | BTU'S., SEER, ETC.). | | | | 2)CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY. PER 2004 FBC 106.1.1. | | | | 3) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE PRINTED NAME AND | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. PER | | FBC 104.2.1. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
|