Plan Review Details - Permit 07020129
Plan Review Stops For Permit 07020129 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-10-31 |
|
|
Cont ID |
|
Sent By |
jjohnsto |
Date |
2007-10-31 |
Time |
15:06 |
Rev Time |
8.00 |
Received By |
jjohnsto |
Date |
2007-10-31 |
Time |
15:02 |
Sent To |
|
|
Notes |
2007-10-31 15:06:23 | CONSTRUCTION SERVICES DEPARTMENT | | 200 SECOND STREET, 3RD FLOOR, | | WEST PALM BEACH, FLORIDA33401 | | TEL:561-805-6713FAX:561-805-6731 | | | | JAMES JOHNSTON, | | BUILDING PLAN EXAMINER II | | E-MAIL:JJOHNSTON @WPB.ORG | | | | | | PERMIT NO 07020129 | | PROJECT CHURCH OF CHRIST | | ADDRESS 909 3RD STREET | | DATE OCTOBER 30, 2007 | | | | | | BUILDINGPLANREVIEW | | | | FLORIDA BUILDING CODES 2004 W REVISIONS | | | | 1 | | NOTICE OF COMMENCEMENT | | AITEM NO. 7BLANK,INFORMATION REQUIRED | | BITEM NO. 8BLANK,INFORMATION REQUIRED | | | | C THE NOTARY INFORMATION DESCRIBED HEREIN IS | | MISSING. | | DNAME OF PERSON, INFORMATION REQUIRED E | | TYPE OF AUTHORITY,INFORMATION REQUIRED F TYPE | | OF IDENTIFICATION,INFORMATION REQUIRED | | | | COMMENTA COPY OF THIS DOCUMENT SHALL BE RETAINED FOR | | USE AS REQUIRED. | | PLEASE SUBMIT A NEW COMPLETED AND RECORDED | | NOTICE OF COMMENCEMENT FOR COMPLIANCE REVIEW | | | | 2 | | ARCHITECT TITLE BLOCK | | COMMENTTHE ARCHITECT MUST PROVIDE THE DBPR WITH THE | | | | CORRECT ADDRESS THAT MATCHES THE INFORMATION IN THE | | TITLE BLOCK. | | SEE ATTACHED INFORMATION ON FILE W DBPR | | | | | | 3 | | TITLE BLOCK | | FLORIDA ADMINISTRATIVE CODE61G1-16.004 | | A TITLE BLOCK IS REQUIRED ON ALL ARCHITECTURAL | | DRAWINGS. | | THE TITLE BLOCK MUST AT A MINIMUM CONTAIN THE | | FOLLOWING | | | | INFORMATION: | | FIRM NAME,ADDRESS,TELEPHONE NUMBER | | NAME OR IDENTIFICATION OF PROJECT | | DATE PREPARED | | A SPACE FOR THE SIGNATURE AND DATED SEAL | | A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING THE | | DOCUMENT | | | | COMMENTPLEASE PROVIDE THIS INFORMATION ON ALL PLAN | | SHEETS | | | | | | 4 | | PROJECT INFORMATION | | FBC2004 BUILDING W/ 2005 AND 6 REVISIONS | | FBC2004 ACCESSIBILITYCHAPTER 11 | | FBC2004 EXISTING BUILDING | | LEVEL OF ALTERATION FBC EXISTING LEVEL III | | TYPE OF CONSTRUCTION FBC503 | | V-B | | SPRINKLED / UN-SPRINKLED | | UN-SPRINKLED | | BASIC WIND SPEED | | 140MPH | | WIND EXPOSUREFBC1609.4B | | WIND IMPORTANCE FACTOR1604.5CATII - | | 1.00 | | TYPE OF OCCUPANCY | | A | | OCCUPANT LOADFBC 1004 62 | | | | COMMENT-NOTE THE FOLLOWING INFORMATION ON | | THE COVER SHEET | | | | | | 5 | | ACCESSIBLE ROUTE. A CONTINUOUS UNOBSTRUCTED PATH | | CONNECTING ALL ACCESSIBLE ELEMENTS AND SPACES OF A | | BUILDING OR FACILITY. INTERIOR ACCESSIBLE ROUTES MAY | | INCLUDE | | CORRIDORS, FLOORS, RAMPS, ELEVATORS, LIFTS, AND CLEAR | | FLOOR | | SPACE AT FIXTURES. EXTERIOR ACCESSIBLE ROUTES MAY | | INCLUDE | | PARKING ACCESS AISLES, CURB RAMPS, CROSSWALKS AT | | VEHICULAR WAYS, WALKS, RAMPS AND LIFTS. | | | | 5A | | FLORIDA BUILDING CODE BUILDING 11-4.3ACCESSIBLE | | ROUTE | | (1)AT LEAST ONE ACCESSIBLE ROUTE WITHIN THE BOUNDARY | | OF THE SITE SHALL BE PROVIDED FROM PUBLIC | | TRANSPORTATION | | STOPS, ACCESSIBLE PARKING, AND ACCESSIBLE PASSENGER | | LOADING ZONES, AND PUBLIC STREETS OR SIDEWALKS TO THE | | ACCESSIBLE BUILDING ENTRANCE THEY SERVE. | | THE ACCESSIBLE ROUTE SHALL, TO THE MAXIMUM EXTENT | | FEASIBLE, | | COINCIDE WITH THE ROUTE FOR THE GENERAL PUBLIC. | | | | 5B | | 11-4.30.7 SYMBOLS OF ACCESSIBILITY. | | (1) FACILITIES AND ELEMENTS REQUIRED TO BE IDENTIFIED | | AS | | ACCESSIBLE BY SECTION 11-4.1 SHALL USE THE | | INTERNATIONAL | | SYMBOL OF ACCESSIBILITY. | | THE SYMBOL SHALL BE DISPLAYED AS SHOWN IN FIGURE 43 (A) | | AND FIGURE 43 (B). | | | | COMMENT ? PROVIDE A SITE PLAN WITH THE FOLLOWING | | APARKING SPACES W LINES - MEASUREMENTS -COLORS B | | HANDICAP PARKING SPACE WITH DOUBLE LINES, COLOR OF | | STRIPING, HANDICAP SYMBOL ON PAVEMENT, | | CHANDICAP SIGN W POLE. SHOW POLE HEIGHT FROM GRADE TO | | BOTTOM OF SIGN ATTACHED, | | DATTACHED SIGN WITH HC SYMBOL ? STRIPING, COLOR AND | | DOLLAR VALUE OF FINE INSERTED | | EACCESS ISLE WITH STRIPING-WIDTH OF ISLE AND | | CONNECTION | | TO BUILDING EXTERIOR PORCH WALKWAY | | | | | | 6 | | FBC BUILDING 11-4.1.3 ACCESSIBLE BUILDINGS: | | NEW CONSTRUCTION | | (1)AT LEAST ONE ACCESSIBLE ROUTE COMPLYING WITH | | SECTION | | 11-4.3 SHALL CONNECT ACCESSIBLE BUILDING OR FACILITY | | ENTRANCES WITH ALL ACCESSIBLE SPACES AND ELEMENTS | | WITHIN THE BUILDING OR FACILITY. | | | | COMMENT | | APROVIDE A DETAIL SHOWING THE ELEVATIONS OF THE | | APPROACH | | FROM THE ACCESSIBLE ISLE (5 FEET WIDE)IN THE | | PARKING LOT | | TO THE NEW PORCH SLAB. SHOW PAVING ELEVATION, RAMP | | IF | | REQUIRED AND SLAB ELEVATION | | | | BPROVIDE A DETAIL SHOWING THE ELEVATION OF THE NEW | | PORCH | | SLAB ANDTHE ENTRANCE OF THE BUILDING ADDITION | | SLAB | | | | CPROVIDE A DETAIL SHOWING THE ELEVATIONS OF THE NEW | | PORCH SLAB CONNECTING TO THE EXISTING PORCH SLAB. | | | | | | | | | | 7 | | FBC BUILDING1609.1.3COMPONENTS & CLADDING ANCHORAGE | | AGAINST OVERTURNING, UPLIFT AND SLIDING. STRUCTURAL | | MEMBERS AND SYSTEMS AND COMPONENTS | | AND CLADDING IN A BUILDING OR STRUCTURE SHALL BE | | ANCHORED | | TO RESIST WIND-INDUCED OVERTURNING, UPLIFT AND SLIDING | | | | AND TO PROVIDE CONTINUOUS LOAD PATHS FOR THESE FORCES | | TO THE FOUNDATION. | | | | COMMENTS-PROVIDE A WINDOWAND DOOR SCHEDULE WITH THE | | INFORMATION AS FOLLOWS | | A WINDOW SIZE | | BROUGH OPENING SIZE | | CWINDOW TYPE SH ?FIXED- | | DWIND LOADS CHPT 1609.DESIGN PRESSURE NEG AND POS | | FOR EACH WINDOW | | EGLAZINGIMPACT ? NON IMPACT | | FEXTERIOR DOOR TYPE AND SIZE | | GDESIGN PRESSURE FOR EACH DOOR WIND LOADS CHPT 1609. | | | | DESIGN PRESSURE NEG AND POS | | | | | | | | 8 | | 1008.1.8.3 LOCKS AND LATCHES. | | LOCKS AND LATCHES SHALL BE PERMITTED TO PREVENT | | OPERATION | | OF DOORS WHERE ANY OF THE FOLLOWING EXISTS: | | 2.IN BUILDINGS IN OCCUPANCY GROUP A HAVING AN | | OCCUPANT LOAD OF 300 OR LESS,AND IN CHURCHES, THE | | MAIN | | EXTERIOR DOOR OR DOORS ARE PERMITTED TO BE EQUIPPED | | WITH | | KEY-OPERATED LOCKING DEVICES FROM THE EGRESS SIDE | | PROVIDED: | | 2.1.THE LOCKING DEVICE IS READILY DISTINGUISHABLE | | AS LOCKED, | | 2.2.A READILY VISIBLE DURABLE SIGN IS POSTED ON | | THE EGRESS | | SIDE ON OR ADJACENT TO THE DOOR STATING: THIS DOOR TO | | REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. | | THE SIGN SHALL BE IN LETTERS 1 INCH (25 MM) HIGH ON A | | CONTRASTING BACKGROUND, | | | | COMMENTS- | | PROVIDE A HARDWARE SCHEDULE FOR THE EXTERIOR DOORS | | PROVIDE A HARDWARE SCHEDULE FOR THE INTERIOR DOORS | | | | | | | | 9 | | PRODUCT APPROVALS REQUIRED | | FBC 1609.1.4 AND WPB ADMINISTRATIVE CODE 106.3 | | REGULATED BY DCA RULE 9B-72FLORIDA PRODUCT APPROVALS | | | | COMMENTS- | | ATHE NOAPGT SH WINDOW EXPIRED10/8/2006 SUBMIT A | | NEW NOA WITH A FLORIDA PRODUCT APPROVAL | | | | BTHE FLORIDA PRODUCT APPROVAL FOR THESIMPSON STRONG | | TIE | | WAS SUBMITTED WITHOUT THE NOA. THE FLORIDA APPROVAL IS | | THE | | COVER SHEET. THE NOA DESCRIBES THE PRODUCT IN DETAIL | | | | | | | | 10 | | FBC BUILDING 104.3 EXAMINATION OF DOCUMENTS 104.3.1 | | PLAN REVIEW. THE BUILDING OFFICIAL SHALL EXAMINE OR | | CAUSE TO BE EXAMINED EACH APPLICATION FOR A PERMIT AND | | THE ACCOMPANYING DOCUMENTS, CONSISTING OF DRAWINGS | | SPECIFICATIONS, COMPUTATIONS AND ADDITIONAL DATA, AND | | SHALL | | ASCERTAIN BY SUCH EXAMINATIONS WHETHER THE | | CONSTRUCTION | | | | INDICATED AND DESCRIBED IS IN ACCORDANCE WITH THE | | REQUIREMENTS OF THE TECHNICAL CODES AND ALL OTHER | | PERTINENT | | LAWS OR ORDINANCES. | | | | COMMENT | | PROVIDE THE SLAB ELEVATION AND THE TOP OF BEAM | | ELEVATION | | ON SHEET 2 | | | | | | | | 11 | | 1807.2.1 FLOORS. | | DAMP PROOFING MATERIALS FOR FLOORS SHALL BE INSTALLED | | BETWEEN | | THE FLOOR AND THE BASE COURSE REQUIRED BY SECTION | | 1807.4.1 , | | EXCEPT WHERE A SEPARATE FLOOR IS PROVIDED ABOVE A | | CONCRETE SLAB. | | WHERE INSTALLED BENEATH THE SLAB, DAMP PROOFING SHALL | | CONSIST OF | | NOT LESS THAN 6-MIL POLYETHYLENE WITH JOINTS LAPPED NOT | | LESS THAN | | 6 INCHES | | | | COMMENTPROVIDE THE MATERIAL DESCRIPTION OF THE | | VISQUEEN | | | | | | | | 12 | | 1805.3.4 FOUNDATION ELEVATION. | | ON GRADED SITES, THE TOP OF ANY EXTERIOR FOUNDATION | | SHALL | | EXTEND ABOVE THE ELEVATION OF THE STREET GUTTER AT | | POINT OF | | DISCHARGE OR THE INLET OF AN APPROVED DRAINAGE DEVICE | | A | | | | MINIMUM OF 12 INCHES (305 MM) PLUS 2 PERCENT. | | | | COMMENTPROVIDE THE FINISHED FLOOR ELEVATION FOR THIS | | SLAB | | | | | | | | 13 | | 1609.1 WIND LOADS | | BUILDINGS, STRUCTURES AND PARTS THEREOF SHALL BE | | DESIGNED | | TO WITHSTAND THE MINIMUM WIND LOADS PRESCRIBED HEREIN. | | | | DECREASES IN WIND LOADS SHALL NOT BE MADE FOR THE | | EFFECT | | OF SHIELDING BY OTHER STRUCTURES. | | | | COMMENTEXPOSURE B | | APROVIDE THE WIND LOADS ON THE BUILDING ELEVATIONS | | 1609.6BHORIZONTAL AND VERTICAL - END ZONES | | - INTERIOR ZONE | | | | BPROVIDE THE WIND LOADS ON THE ROOF STRUCTURE | | ELEVATION | | SEE TABLE1609.6A | | | | CPROVIDE THE WIND LOADSTHE ROOF OVERHANG | | ELEVATION TABLE 1609.6C | | | | | | | | 14 | | 705.4FIRE WALLS -FIRE RESISTANCE RATING | | | | COMMENT | | SEE TABLE 705.4 GROUP ANOTE A | | WALLS SHALL BE NOT LESS THAN 2-HOUR FIRE-RESISTANCE | | RATED | | WHERE SEPARATING BUILDINGS OF TYPE II OR V | | CONSTRUCTION | | | | | | | | 15 | | 705.5 HORIZONTAL CONTINUITY. | | FIRE WALLS SHALL BE CONTINUOUS FROM EXTERIOR WALL TO | | EXTERIOR | | WALL AND SHALL EXTEND AT LEAST 18 INCHES BEYOND THE | | EXTERIOR | | SURFACE OF EXTERIOR WALLS. | | | | EXCEPTIONS: | | 1.FIRE WALLS SHALL BE PERMITTED TO TERMINATE AT | | THE INTERIOR | | SURFACE OF COMBUSTIBLE EXTERIOR SHEATHING OR SIDING | | PROVIDED | | THE EXTERIOR WALL HAS A FIRE-RESISTANCE RATING OF AT | | LEAST 1 HOUR | | FOR A HORIZONTAL DISTANCE OF AT LEAST 4 FEETON BOTH | | SIDES OF | | THE FIRE WALL. | | OPENINGS WITHIN SUCH EXTERIOR WALLS SHALL BE PROTECTED | | BY FIRE | | ASSEMBLIES HAVING A FIRE PROTECTION RATING OF NOT LESS | | | | THAN ? HOUR. \ | | | | COMMENTSEE THIS CHAPTER RELATING TO THE FIRE WALL AND | | THE | | UNDERSIDE OF THE COMBUSTIBLE ROOF PANELS | | | | | | | | 16 | | 710.6 PENETRATIONS AND JOINTS. | | THE SPACE AROUND PENETRATING ITEMS AND IN JOINTS SHALL | | BE | | FILLED WITH AN APPROVED MATERIAL TO LIMIT THE FREE | | PASSAGE | | OF SMOKE. | | | | 713.2 INSTALLATION. | | FIRE-RESISTANT JOINT SYSTEMS SHALL BE SECURELY | | INSTALLED | | IN OR ON THE JOINT FOR ITS ENTIRE LENGTH SO AS NOT TO | | DISLODGE, | | LOOSEN OR OTHERWISE IMPAIR ITS ABILITY TO ACCOMMODATE | | EXPECTED BUILDING MOVEMENTS AND TO RESIST THE PASSAGE | | OF FIRE AND HOT GASES. | | | | COMMENTPROVIDE THE PRODUCT TO BE USED TO SEAL THE | | MASONRY FIRE WALL UNDER THE ROOF TO THE PLYWOOD PANEL | | SHEATHING | | | | | | | | 17 | | 715.3 FIRE DOOR AND SHUTTER ASSEMBLIES. | | APPROVED FIRE DOOR AND FIRE SHUTTER ASSEMBLIES SHALL | | BE | | CONSTRUCTED OF ANY MATERIAL OR ASSEMBLY OF COMPONENT | | MATERIALS THAT CONFORMS TO THE TEST REQUIREMENTS OF | | SECTION 715.3.1 , 715.3.2 OR 715.3.3 AND THE FIRE | | PROTECTION RATING INDICATED IN TABLE 715.3 . | | | | COMMENT- PROVIDE THE FIRE DOOR RATING AND ASSEMBLY SEE | | TABLE715.3 FOR THE FOUR HOUR FIRE WALL | | | | | | | | 18 | | ROOF FRAMING PLAN | | | | COMMENT | | PLEASE PROVIDE A ROOF FRAMING PLAN THAT SHOWS THE | | CONNECTION OF THE NEW ROOF TO THE EXISTING ROOF. | | DETAIL THE FRAMING, BRACING, CRICKETS, VALLEYS, | | FRAMING MEMBER SIZES REQUIRED | | | | | | | | PLEASE NOTE | | THEBUILDING IS RATED BY CODE A TYPEV-B . | | AS THE DESIGNER YOU CAN RATE THE BUILDING | | WITH A FOUR HOUR WALL SO THE BUILDING | | STANDS ALONE, BUT IN DOING SO YOU MUST | | COMPLY WITH THE FOLLOWING COMMENTS AND | | CODE SECTIONS REFERENCED IN THIS CRITIQUE. | | ITEM NO,14,15,16,17 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-07-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-07-18 |
Time |
21:22 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2007-07-18 |
Time |
21:22 |
Sent To |
|
|
Notes |
2007-07-18 21:40:02 | BUILDING PLAN REVIEW | | PERMIT: 07020129 | | ADD: 909 3RD ST | | CONT: NEWBOLD CONSTRUCTION | | TEL: (561)644-5764 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | YOUR ANTICIPATED COOPERATION. | | | | 2) FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | THE COURT.NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | NOT ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3) COMPLIED. | | | | 4) COMPLIED. | | | | 5) PLEASE PROVIDE THE UNITY OF TITLE FOR LOTS 12 & | | 13.THE DOCUMENT SUBMITTED FOR REVIEW HAS NOT BEEN | | SUBMITTED TO THE CLERK OF THE COURT OF PALM BEACH | | COUNTY. ONCE RECORDED PLEASE PROVIDE DOCUMENTATION. | | | | 6) COMPLIED. | | | | 7) COMPLIED. | | | | 8) COMPLIED. | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-03-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-03-13 |
Time |
09:59 |
Rev Time |
3.33 |
Received By |
jwitmer |
Date |
2007-03-13 |
Time |
09:59 |
Sent To |
|
|
Notes |
2007-03-13 10:08:12 | BUILDING PLAN REVIEW | | PERMIT: 07020129 | | ADD: 909 3RD ST | | CONT: NEWBOLD CONSTRUCTION | | TEL: (561)644-5764 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | THE COURT. | | NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | NOT ACTUALLY | | COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF, | | SUCH NOTICE IS | | NULL & VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE | | OF COMMENCEMENT | | AT THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 3)110.2* W. P. B. ADMINISTRATIVE | | CODE, INFORMATION THAT IS REQUIRED FOR | | RECORD KEEPING & FOR CERTIFICATE OF | | OCCUPANCY: | | A) THE EDITION OFTHE CODE UNDER WHICH | | THE PERMIT WAS ISSUED. | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | WITH THE PROVISIONS OF CHAPTER 3. | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | IN CHAPTER 6, TABLE 601. | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | IS REQUIRED. | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | OF THE BUILDING PERMIT. | | | | 4) PLANS ARE COLOR COPIES, PLEASE CREATE ORIGINAL | | DOCUMENTS, AND GET ORIGINAL SIGN-OFFS FROM THE VARIUOS | | GOVERNMENTAL AGENCIES. | | | | 5) PLEASE PROVIDE THE UNITY OF TITLE FOR LOTS 12 & | | 13.THE DOCUMENT SUBMITTED FOR REVIEW HAS NOT BEEN | | SUBMITTED TO THE CLERK OFTHE COURT OF PALM BEACH | | COUNTY. | | ONCE RECORDED PLEASE PROVIDE DOCUMENTATION. | | | | 6)THE ENERGY CALCULATIONS SUBMITTED ARE ON THE | | 2001FBC FORMS, THERE HAS BEEN CHANGES IN THE ENERGY | | CODE AS WELLL AS THE ENERGY FORM SINCE THE 2001 FBC, | | PLEASE CORRECT. | | | | 7)FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, | | PROVIDE 2 COPIES(3 IF THRESH- | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | TESTING REPORTS,MISSING REPORTS ARE AS | | FOLLOWS: | | A) WINDOWS- SINGLE HUNG SUBMITTED REVISION# 2 STATE | | WEBSITE ON CURRENT REVISION# 7. | | ALSO HIGHLIGHT WHICH WINDOW SERIES | | TO BE INSTALLED. | | | | B) EXTERIOR DOORS- THERMA-TRU DOORS FOR THE DOUBLE | | DOORS TO MEET THE WIND PRESSURE REQUIRES A HIGH RISE | | THRESHOLD, PLEASE SEE 1008.1.6, WHICH ALINE WITH | | ACCESSIBLITY REQUIREMENTS. | | 1008.1.6 THRESHOLDS. | | THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.75 INCH (19.1 | | MM) IN HEIGHT FOR SLIDING DOORS SERVING DWELLING UNITS | | OR 0.5 INCH (12.7 MM) FOR OTHER DOORS. RAISED | | THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 0.25 | | INCH (6.4 MM) AT DOORWAYS SHALL BE BEVELED WITH A SLOPE | | NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS | | HORIZONTAL (50-PERCENT SLOPE). | | | | C) ROOFING ASSEMBLIES, STATE APPROVAL FOR OWENS CORNING | | ASPHALT SHINGLES,ARE NOT ON REVISION # 1 NO LONGER, | | ALSO THE REPORT SUBMITTED IS A MIAMI-DADE REPORT NUT A | | UL-REPORT. PLEASE PROVIDE THE APPROPRIATE REPORT , | | STARTER INFORMATION + INFORMATION FOR 3 TAB . | | | | 8)WPB ADMIN CODE 106.3* PRODUCT | | APPROVALS. THOSE PRODUCT WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2007-10-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-10-17 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-10-16 |
Time |
15:51 |
Sent To |
I |
|
Notes |
2007-10-17 11:55:20 | 2007-10-17 11:55:20 | | | | *** DENIED 3RD REVIEW ***** | | | | ** PLEASE SEE COMMENTS FROM PREVIOUS REVIEWS STILL NEED | | TO BE ADDRESSED ALONG WITH NEW COMMENTS AS PLANS/RISER | | HAS BEEN REVISED ONCE AGAIN. | | | | | | 1) NOTE: AS REQUESTED ON THE TWO PREVIOUS REVIEWS. | | PLEASE STATE AND SHOW ON PLANS THE RELEVANT CODE IN | | WHICH PROJECT IS DESIGNED UNDER. | | THE YEARS FOR CODES ARE REQUIRED. | | PLEASE ALSO SEE PALM BEACH COUNTY IS BEING NOTED ON | | SHEET E-1 WHEN PROJECT IS IN THE CITY OF WEST PALM | | BEACH. | | PLEASE BE SURE ALL PLANS REFLECT THE LATEST ADOPTED | | CODES PER THE STATE OF FLORIDA. PLEASE SEE THE | | FOLLOWING WHICH ARE CURRENTLY ADOPTED AS OF DECEMBER | | 8TH, 2006. | | 2004 FBC W/ 2006 REVISIONS. THIS WILL AFFECT PLANS | | SUBMITTED | | 2005 NFPA-70 (NEC). THIS WILL AFFECT PLANS SUBMITTED. | | 2002 NFPA-72 | | 2003 NFPA-101 | | | | ** PLEASE SEE COMMENTS FROM OTHER TRADES WHICH MAY | | INDICATE CODES NEEDED. | | | | 2) NOTE:PLEASE CORRELATE ELECTRICAL ON PLANS WITH | | THAT OF THE ARCHITECTURAL AND MECHANICAL PLANS. FOR | | EXAMPLE: PLEASE SEE THE LOCATION OF THE NEW SUB PANEL | | ON A AND M SHEETS ARE IN A COMPLETELY SEPARATE LOCATION | | AND THE SIZE OF THE PANEL IS NOT THE SAME AS THE | | ELECTRICAL PLANS. | | PLEASE LABEL ALL ELECTRICAL EQUIPMENT ON PLANS FOR | | ELECTRICAL. * PANEL *A*, ETC. | | NEC 110.26, 240.4, 215.5, 230,ETC | | FBC 106.1.2, 106.3.5.1.2 | | | | 3) NOTE: PLEASE SEE THE ELECTRICAL RISER DIAGRAM AS | | SUBMITTED ALONG WITH LOAD CALCULATIONS AND PLANS DO NOT | | CORRELATE WITH NUMEROUS ITEMS. THIS REVIEWER CAN ONLY | | GIVE A FEW EXAMPLES AS THERE ARE TOO MANY ITEMS WHICH | | DO NO MATCH AND DO NOT THE MINIMUM REQUIREMENTS OF THE | | ELECTRICAL CODE. | | | | FOR EXAMPLE: | | PLEASE SEE E-1 ABOVE ELECTRICAL LEGEND WHICH INDICATES | | A 400AMP MLO PANEL, YET THERE IS NO WHERE ON ELECTRICAL | | RISER WHICH INDICATES A 400MLO PANEL. | | PLEASE SEE LOAD CALCULATIONS WHICH INDICATE PANEL *C* | | AND *LP* AS EXISTING CHURCH AND NEW FELLOWSHIP HALL, | | YET THE PANEL SCHEDULES TO THE RIGHT DO NOT INDICATE | | THE SAME LOADS OR PANEL SIZES. | | PLEASE SEE RISER WHICH SHOWS PANEL *C* AS 125AMP, YET | | PANEL SCHEDULES SHOW BOTH *C* AND *LP* AS 200AMP. HOW | | CAN *C* AND *LP* PANEL SCHEDULE BE THE SAME WHEN THEY | | CLEARLY DO NOT HAVE THE SAME CIRCUITS? | | PLEASE SEE RISER SHOWS 3PHASE EQUIPMENT, PANELS SERVICE | | ETC INCLUDING AS NOTED FOR CONDUCTOR COLOR CODING YET | | THE RISER AND SEVERAL OTHER LOCATIONS ONLY INDICATE A | | SINGLE PHASE SERVICE. | | | | **THE ABOVE ARE ONLY SOME OF THE INCONSISTENCIES ON | | PLANS. THERE ARE SEVERAL OTHER ITEMS WHICH ARE TOO MANY | | TO LIST. | | ** PLEASE SUBMIT ELECTRICAL PLANS, LOAD CALCULATIONS, | | AND RISER DIAGRAM WHICH CORRELATE, ARE CODE COMPLIANT | | AND CAN BE REVIEWED AS AN ELECTRICAL INSTALLATION. MAY | | NOT HAVE A 40 SPACE MLO AS DISTRIBUTION PANEL. NEC, | | 100, 230.70,71,72,76,79, 215.5, 310.16, 240.4 ETC | | **2005 NATIONAL ELECTRICAL CODE** | | FBC 106.3.5.1.2, 106.1.2 | | | | 4) NOTE: PLEASE SEE 700.12F AS ALL EXIT AND EMERGENCY | | LIGHTING FIXTURES AS NOTED ON THE PREVIOUS REVIEWS ARE | | REQUIRED TO BE CIRCUITED TO THE NORMAL BRANCH CIRCUIT | | LIGHTING IN THAT AREA. PLEASE SEE THAT PLANS HAVE | | REVISED AND CORRECTED MOST OF THESE BUT NOT ALL. (END | | OF FELLOWSHIP HALL) | | | | 5) NOTE:PLEASE KNOW THAT COMPLETE LOAD CALCULATIONS | | WHICH MEET THE MINIMUM REQUIRED BY CODE. THE SAME | | SECTIONS AS GIVEN IN THE PREVIOUS TWO REVIEWS REMAIN. | | THE CALCULATIONS ARE STILL SHOWING ONE CALCULATION FOR | | NEW PANELS WHICH ARE NOT THE SAME AS PANEL SCHEDULES OR | | PLANS. THIS WAS NOTED ABOVE FOR COORDINATION OF PLAN | | HOWEVER AS THIS WAS SPECIFICALLY NOTED ON PREVIOUS | | REVIEW, IT IS BEING NOTED ONCE AGAIN. | | PLEASE SUBMIT LOAD CALCULATIONS WHICH ARE CODE | | COMPLAINT, CORRELATE WITH PLANS, AND PANEL SCHEDULES. | | FOR EXAMPLE, PLEASE SEE SEVERAL BRANCH CIRCUITS WHICH | | ARE SHOWING LOADS WHICH EXCEED THE RATINGS FOR THE | | BRANCH CIRCUIT. SEE ONE SET OF PLANS ARE REDLINED FOR | | SOME OF THESE CIRCUITS SUCH AS CIRCUIT #15 ON *C*/LP*, | | WHICH SHOWS 3.6KW ON A SINGLE POLE 20AMP CIRCUIT. | | (3600VA DIVIDED BY 120V IS 30AMPS) THIS IS NOT | | PERMITTED ON THE BRANCH CIRCUIT. (TYPICAL MAXIMUM LOAD | | ON A 20AMP BRANCH CIRCUIT IS 1920VA). | | SEE CIRCUITS #6, #15, #24 ETC ON LP-A, #8, #15, #16, | | #17, #18 ETC ON *C* *LP*. | | PLEASE SEE NEC 220, 220.12, 220.14, 220.42, 220.44, | | ETC. | | 215.5, 215.3, 230.42 ETC | | 310.16, 240.4 ETC. | | 210.3, 210.20, 210.23 ETC. | | PLEASE KNOW THERE ARE SEVERAL AND TOO MANY SPECIFIC | | CODE SECTIONS TO STATE ON REVIEW NOTES. PLEASE SEE NEC | | 2005. | | FBC 106.1.2, 106.3.5.1.2 | | | | 6) NOTE: PLEASE SEE AS PANEL SCHEDULE AND LOAD | | CALCULATIONS FOR PANEL *C*/*LP* SHOWS A PANEL AS | | 200AMPS AND LOADS WHICH EXCEEDS THE 125AMP RATING OF | | PANEL ON RISER (AS SHOWN) PLEASE BE SURE TO SEE 250.122 | | FOR SIZING ADJUSTMENTS OF THE EQUIPMENT GROUNDING | | CONDUCTOR. PLEASE KNOW IN ANY CASE THE #8 AS SHOWN ON | | RISER FOR THE 125AMP PANEL IS TOO SMALL PER 250.122 ** | | THIS WILL BE REQUIRED TO BE COORDINATED WITH THE NOTED | | ABOVE WITH RESPECT TO RISER ETC. | | | | 7) NOTE: PLEASE VERIFY 250MCM FROM MAIN DISCONNECT TO | | PANEL *LP* ON RISER.. THIS IS BEING SHOWN AS A 200AMP | | PANEL. PLEASE VERIFY THAT THE LUGS ON THIS EQUIPMENT | | WILL ACCEPT THE 250MCM. | | 110.3, 90.7, 110.14 FOR LISTING OF EQUIPMENT. | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | 8) NOTE: PLEASE SEE MISSING EQUIPMENT GROUNDING | | CONDUCTOR TO PANEL *LP*> | | 250.110, 250.24, 250.122 | | | | 9) NOTE: PLEASE SUBMIT THE PANEL DESIGNATIONS AND PANEL | | SCHEDULES FOR EACH OF THE PANELS WHICH ARE SHOWN ON | | RISER. AS NOTED ABOVE IN NOTES #5 AND #2, THERE IS | | COORDINATION NEEDED. | | PLEASE SEE ONLY TWO PANEL SCHEDULES WERE SUBMITTED AND | | REVIEW FOR CODE COMPLIANCE COULD NOT BE COMPLETED. | | 408.4, 215.5,240.4, 310.16 ETC | | FBC 106.3.5.1.2, 106.1.2 | | | | 10) NOTE: PLEASE SEE NEW NOTE ADDED TO THE LOWER LEFT | | HAND SIDE OF E-2 WHICH STATES *PREVIOUS PERMIT | | #07020129 EXPIRED*. HOW IS THIS POSSIBLE WHEN THIS | | PERMIT WHICH IS CURRENTLY IN REVIEW IS STILL THE SAME | | PERMIT WHICH HAS NOT EXPIRED? | | PLEASE ADJUST PLANS. | | ** THE PREVIOUS PERMIT APPLICATION DID EXPIRE HOWEVER | | WAS NEVER ISSUED FOR PERMIT. THAT PERMIT NUMBER IS | | 05010378. | | THIS DOES NOT NEED TO BE ON PLANS AS IT WAS NEVER | | ISSUED AND WORK WAS NOT DONE UNDER THAT PERMIT. | | | | 11) NOTE: PLEASE SEE COMPLIANCE WITH FBC CHAPTER 13 HAS | | NOT YET BEEN ACHIEVED. | | A) PLEASE SEE THE ENERGY CALCULATIONS AS SUBMITTED DO | | NOT CORRELATE WITH PLANS. PLEASE BE SURE TO SEE | | MECHANICAL REVIEW FOR POSSIBLE METHOD OF CALCULATION | | COMMENT. | | PLEASE SEE THERE SEEMS TO BE TWO DIFFERENT TYPES OF | | LIGHTING FIXTURES ON PLANS AS E-1 SHOWS A COMPLETELY | | DIFFERENT TYPE OF LIGHT FIXTURE/SYMBOL THAN ON E-2. | | PLEASE SEE THE FIXTURE LEGEND DOES NOT CONTAIN THE | | COMPLETE WATTAGE INFORMATION FOR ALL LIGHT FIXTURES | | (EXAMPLE RECESSED FLUORESCENT LIGHT). PLEASE BE SURE | | THIS INFORMATION CORRELATES WITH THE INPUT DATA | | REPORT. | | PLEASE SEE THE EXTERIOR LIGHTS ON THE PLANS DO NOT | | CORRELATE WITH THE INPUT DATA REPORT OR THE FIXTURE | | LEGEND. ONE ITEM FOR EXAMPLE IS THAT THE WALL PACK | | FIXTURE WHICH IS ON LEGEND BUT *BLANK*? | | PLEASE SEE THE INPUT DATA REPORT SHOWS TWO TYPES OF | | FIXTURES, YET NEITHER OF THESE IS ON FIXTURE LEGEND. | | PLANS DO SHOW THREE TYPES OF LIGHTING FIXTURES | | OUTSIDE. | | PLEASE COMPLETE FIXTURE TYPE DESIGNATIONS ON PLANS AND | | FIXTURE LEGEND SO THESE CORRELATE. THEN PLEASE | | CORRELATE ALL LIGHTING INFORMATION ON PLANS WITH THAT | | OF THE INPUT DATA REPORT. | | PLEASE SEE 13-415.1.AB.1, 13-415.1.A, .B, .C, 13-415.2, | | 13-415.2.ABC.1.3 ETC. | | ** PLEASE SEE ONLY ONE COPY OF THE INPUT DATA REPORT | | WAS SUBMITTED. PLEASE SUBMIT TWO COPIES AS ONE WILL BE | | STAMPED FOR FILE AND THE OTHER IS STAMPED FOR FIELD SET | | OF PLANS. | | B) PLEASE SEE THE PLANS DO NOT INDICATE ANY METHOD OF | | CONTROLS FOR EXTERIOR LIGHTING WHICH COMPLIES WITH | | 13-415.1.ABC.1, 13-415.1.ABC.1.4 | | PLEASE SEE NO CONTROLS ARE SHOWN FOR 13-415.1.ABC.1, | | 13-415.1.ABC.1.2 | | | | 12) NOTE: PLEASE SEE PREVIOUS REVIEW GAVE NOTICE TO FS | | 553.80(2)(B) WITH RESPECT TO REPEAT COMMENTS FOR CODE | | COMPLIANCE. PLEASE SEE THERE ARE SEVERAL CODE SECTIONS | | WHICH WERE REPEATED AND THE FEE HAS BEEN ASSESSED AS | | REQUIRED BY THE FLORIDA STATUTES. | | THIS FEE IS DUE BEFORE PLANS CAN BE RE-SUBMITTED FOR | | THE NEXT REVIEW. THIS FEE IS NOT THE RESPONSIBILITY OF | | THE CONTRACTOR OR OWNER. THIS IS SET-FORTH BY THE | | BOARDS AND THE STATE FOR THE DESIGN PROFESSIONAL. THE | | FEE IS $1860.00 | | ** PLEASE KNOW ONE COPY OF ELECTRICAL PLANS AND ENERGY | | CALCULATIONS WILL BE RETAINED BY THIS OFFICE. OTHER | | SHEETS MAY BE RETAINED BY OTHER TRADES. | | | | 13) NOTE: PLEASE SEE ONCE AGAIN THE ARCHITECT ON | | ELECTRICAL PLANS DID NOT DATE THE PLANS WHEN THEY WERE | | SIGNED AND SEALED. THIS WAS A NOTE GIVEN ON PREVIOUS | | REVIEWS AND IS STILL REQUIRED AS THIS IS A FLORIDA | | STATUTE. | | PLEASE SEE 481.221 | | | | ** AS STATED ON PREVIOUS REVIEW: | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS | | OR COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. | | IF THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY | | WAY, NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, | | PLEASE DO NOT HESITATE IN CONTACTING THIS OFFICE AND | | THIS REVIEWER. | | | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | 2007-10-16 15:53:17 | 2007-10-17 15:53:17 | | | | PLANS REMOVED FROM INCOMING FOR REVIEW DUE TO DATE FOR | | WHICH ELECTRICAL REVIEWER IS UP TO. | | PLANS WILL BE RETURNED TO INCOMING WAITING FOR | | COMMERCIAL BOARD ONCE REVIEW IS COMPLETED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2007-06-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-06-24 |
Time |
12:18 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-06-24 |
Time |
11:16 |
Sent To |
|
|
Notes |
2007-06-24 12:18:15 | | | | | *** UNSAT 2ND REVIEW*** | | | | ** PLANS FAILED FOR MANY OF THE SAME ITEMS AS STATED ON | | PREVIOUS REVIEW. PLEASE SEE THERE ARE ALSO NEW COMMENTS | | BASED ON REVISIONS AND CHANGES MADE TO PLANS. | | ** PLANS ORIGINALLY SUBMITTED UNDER PERMIT NUMBER | | 05010378 WHICH BECAME *EXPIRED*. | | | | | | 1) NOTE:THIS REMAINS THE SAME NOTE AS THIS | | INFORMATION WAS NOT PLACED ON PLANS. | | PLEASE BE SURE ALL PLANS REFLECT THE LATEST ADOPTED | | CODES PER THE STATE OF FLORIDA. PLEASE SEE THE | | FOLLOWING WHICH ARE CURRENTLY ADOPTED AS OF DECEMBER | | 8TH, 2006. | | 2004 FBC W/ 2006 REVISIONS. THIS WILL AFFECT PLANS | | SUBMITTED | | 2005 NFPA-70 (NEC). THIS WILL AFFECT PLANS SUBMITTED. | | 2002 NFPA-72 | | 2003 NFPA-101 | | | | ** PLEASE SEE COMMENTS FROM OTHER TRADES WHICH MAY | | INDICATE CODES NEEDED. | | | | 2) NOTE:PLEASE CORRELATE ELECTRICAL ON PLANS WITH | | THAT OF THE PANEL SCHEDULE(S). | | PLEASE SEE THERE ARE COMMENTS BELOW WITH RESPECT TO | | CIRCUITING WHICH IS STILL NOT CORRECT. | | NEC 408.4 | | PLEASE CORRELATE AND COORDINATE ALL. | | FBC 106.1.2, 106.3.5.1.2 | | PLEASE CORRELATE PANEL SCHEDULE AND COMPLETE PANEL | | SCHEDULE(S) SO THAT ALL ITEMS ON PANEL SCHEDULE ARE | | SPECIFIC TO AREAS AND ROOMS IN WHICH THEY FEED. PLEASE | | SEE COMMENTARY BELOW EXTRACTED FROM THE CODE. *SECTION | | 408.4 WAS REVISED FOR THE 2005 CODE TO REQUIRE THAT THE | | IDENTIFICATION FOR EVERY CIRCUIT SUPPLIED BY A | | PANELBOARD OR SWITCHBOARD BE LEGIBLE AND CLEARLY STATE | | THE SPECIFIC PURPOSE FOR WHICH THE CIRCUIT IS USED. | | CIRCUITS USED FOR THE SAME PURPOSE MUST BE IDENTIFIED | | AS TO THEIR LOCATION. FOR EXAMPLE, SMALL APPLIANCE | | BRANCH CIRCUITS CAN SUPPLY OUTLETS IN THE KITCHEN, | | DINING ROOM, AND KITCHEN COUNTERTOPS. IDENTIFYING THE | | CIRCUITS AS SMALL APPLIANCE BRANCH CIRCUITS IS NOT | | ACCEPTABLE; INSTEAD, THEY SHOULD BE IDENTIFIED AS | | "KITCHEN WALL RECEPTACLES,'' "DINING ROOM FLOOR | | RECEPTACLE,'' OR "KITCHEN COUNTERTOP RECEPTACLES LEFT | | OF SINK.'' CIRCUIT DIRECTORIES CONTAINING MULTIPLE | | ENTRIES WITH ONLY "LIGHTS'' OR "OUTLETS'' DO NOT | | PROVIDE THE SUFFICIENT DETAIL REQUIRED BY THIS | | SECTION. | | | | 3) NOTE: PLEASE SEE THIS IS THE SAME NOTE AS PREVIOUS | | REVIEW. PLEASE SEE SEVERAL EMERGENCY LIGHTS AND EXIT | | LIGHTS ARE STILL BEING SHOWN ON DEDICATED CIRCUITS | | WHICH ARE ONLY PERMITTED UNDER CERTAIN CONDITIONS, | | BASED ON PLANS THE EXCEPTIONS AS STATED IN THE NEC DOES | | NOT APPLY AND THESE FIXTURES ARE REQUIRED TO BE | | CIRCUITED TO THE LOCAL LIGHTING CIRCUIT IN ANY ONE | | AREA. PLEASE SEE THE NOTE WITH RESPECT TO LOADS. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE 700.12F FOR EMERGENCY AND EXIT LIGHTS. | | THIS COMMENT WAS MADE ON ALL OTHER REVIEWS UNDER | | PREVIOUS PERMIT APPLICATION; HOWEVER NO CHANGES TO | | PLANS OR CIRCUITING HAVE BEEN MADE. PLEASE SEE OTHER | | AREA ON PLANS WHICH DO NOT SHOW CIRCUITS FOR THESE, | | NOTE TO CIRCUIT TO PANEL HOWEVER THESE SHALL BE | | CIRCUITED TO LOCAL LIGHTING BRANCH CIRCUIT. | | THE BRANCH CIRCUIT FEEDING THE UNIT EQUIPMENT SHALL BE | | THE SAME BRANCH CIRCUIT AS THAT SERVING THE NORMAL | | LIGHTING IN THE AREA AND CONNECTED AHEAD OF ANY LOCAL | | SWITCHES. | | | | 4) NOTE:PLEASE KNOW THAT COMPLETE LOAD CALCULATIONS | | FOR THE PROPOSED SERVICE AND PANELS AS PREVIOUSLY | | REQUESTED HAS NOT BEEN SUBMITTED. | | PLEASE SEE TWO SEPARATE LOAD CALCULATIONS SHOWN FOR | | SAME PANEL? | | FBC 106.1.2, 106.3.5.1.2 | | | | ** PREVIOUS REVIEW NOTE** | | PLEASE SHOW LOAD CALCULATIONS, PLEASE SHOW PER, 220.12, | | 220.14, 220.42, 220.44 ETC. | | PLEASE ALSO SHOW ALL CONTINUOUS LOADS AT 125% PER | | 215.3, AND 230.42 | | PLEASE SEE LOAD CALCULATIONS SUBMITTED DO NOT ALL | | CORRELATE WITH THE LOADS SHOWN ON PANELS. PLEASE SEE | | SUB PANEL *C*. | | PLEASE SHOW LOAD CALCULATIONS FOR SERVICE AS REQUESTED | | ON PREVIOUS REVIEWS UNDER OLD EXPIRED PERMIT. PLEASE | | SEE ITEMS ON LOAD CALCULATIONS WHICH ARE NOT ON PANEL | | SCHEDULE(S). (SIGN CIRCUIT) | | | | 5) NOTE: PLEASE SEE ONCE AGAIN THE SERVICE RISER HAS | | BEEN REVISED AND IS STILL NOT CODE COMPLIANT. PLEASE | | SEE NOTES ON E-1 WHICH STATES THIS NEW SERVICE IS A MLO | | PANEL WHEREAS THE RISER INDICATES THIS AS A METER/MAIN | | COMBO? 230.70, 230.71 (MAIN REQUIRED). PLEASE SEE THE | | RISER SHOWS AND NOTES THIS SERVICE AS NEW YET THE RISER | | ALSO CONTAINS NOTES FOR EXISTING? PLEASE SEE THE | | FEEDERS FOR THE NEW 200AMP PANEL ARE NOT CODE COMPLIANT | | PER 310.16 | | PLEASE SEE THE RISER WHICH SHOWS TWO MAIN DISCONNECTS: | | ONE 200AMPS AND THE OTHER 150AMPS BOTH FEEDING A SINGLE | | CONDUIT WITH 2/0 FEEDERS TO A GUTTER WHICH TAPS TO | | 125AMP PANEL AND A 150AMP PANEL. THIS ENTIRE SCENARIO | | IS NOT CODE COMPLIANT FROM THE FEEDERS, THE TAPS, TO | | TERMINATION IN OPC, THE SINGLE CONDUIT WITH TWO | | BREAKERS SHOWN FEEDING ONE? ETC ETC. PLEASE SEE 215.5, | | 310.16, 240.4, 408, 240.21 ETC. THERE ARE TOO MANY CODE | | SECTIONS TO BE REFERENCED. | | PLEASE SUBMIT A CODE COMPLIANT RISER. | | PLEASE SUBMIT THE PANEL SCHEDULES WHICH INDICATE THE | | OCP FEEDING TO SUB PANELS. | | PLEASE SEE THE 2005 NEC AND KNOW IF ANY OF THESE | | CONDITIONS EXIST AT THIS LOCATION AS SHOWN ON PLANS, | | THE ENTIRE ELECTRICAL SERVICE WILL BE REQUIRED TO | | BROUGHT UP TO CODE. | | | | ** PREVIOUS REVIEW NOTE** | | PLEASE SEE A COMPLETELY NEW RISER DIAGRAM HAS NOW BEEN | | SUBMITTED AND IS MISSING INFORMATION NEEDED FOR CODE | | COMPLIANCE AND FOR REVIEW. | | PLEASE SEE THE NEXT SEVERAL ITEMS ARE BEING STATED IN | | THIS ONE COMMENT. | | A) PLEASE SEE MISSING AIC RATINGS FOR ALL SERVICE | | EQUIPMENT AND MAINS. | | B) PLEASE SHOW LOCATIONS OF ALL SERVICE EQUIPMENT ON | | PLANS. | | C) PLEASE CORRELATE PLANS AND RISER AND PANELS. PLEASE | | SEE PLANS SHOWS 150A PANEL AS EXISTING, PANEL SCHEDULE | | FOR *C* SHOWS 150AMP AND 125AMP. PLEASE SEE LOAD ON | | THIS PANEL DOES NOT CORRELATE WITH LOAD CALCULATIONS. | | PLEASE SEE PANEL *B* WHICH SHOWS DIFFERENT FEEDERS, | | DIFFERENT OVER CURRENT PROTECTION ETC. | | D) PLEASE SEE SERVICE ENTRANCE CONDUCTORS ARE NOT RATED | | FOR SERVICE. | | ETC. | | 215.5, 310.16, 408.4, 240.4, 110.9, 240.24, 408.7 ETC | | PLEASE SEE 2005 NEC. | | | | 6) NOTE:PLEASE SEE COMPLIANCE WITH CHAPTER 13 HAS NOT | | BEEN MET. | | PLEASE SEE NO DESIGN CHANGES OR CONSIDERATION WAS GIVEN | | TO PREVIOUS NOTES WITH RESPECT TO LIGHTING CONTROLS | | REQUIRED. | | PLEASE SEE NO INFORMATION OR RESPONSE TO THESE COMMENT | | TO PROVIDE INFORMATION FOR REVIEW WAS IN PACKAGE SO THE | | COMMENTS REMAIN. | | PLEASE SEE NO TIMED SCHEDULING SYSTEM IS SHOWN IF IN | | DESIGN, OTHER MEANS OF LIGHTING CONTROLS MAY BE SUED. | | PLEASE SEE NO AUTOMATED DEVICES ARE SHOWN. | | PLEASE SEE NO OVER RIDE TIMES ARE SHOWN. | | PLEASE SEE NO DEVICE LOCATIONS WERE SHOWN. | | PLEASE SEE THE ENERGY CALCULATIONS AS SUBMITTED FOR | | METHOD OF CONTROLS IS NOT CORRECT. | | PLEASE SEE NO OWNER AGENT WAS SIGNED ON SHEETS AS | | REQUIRED. | | PLEASE SEE THE FIXTURE LEGEND IS NOT COMPLETE WITH ALL | | INFORMATION FOR FIXTURES FOR COORDINATION REVIEW WITH | | THE SUBMITTED ENERGY CALCULATIONS. | | PLEASE SEE NOTE WITH RESPECT TO THE ENGINEER AS SHOWN | | CERTIFYING THE ENERGY CALCULATIONS. | | PLEASE SEE NO SEPARATE SPACE CONTROLS ARE SHOWN. PLEASE | | SEE NOT RESPONSE LETTER WAS SUBMITTED OR INFORMATION | | FOR THIS. | | PLEASE SEE COMPLIANCE WITH THE 2004 FBC CHAPTER 13 FOR | | CONTROL OF LIGHTING PER 13-415.1ABC.1.1, .1.2 AND | | .1.3. | | PLEASE SEE13-415.1.AB.1.1, 13-415.2 FOR LIGHTING | | PERFORMANCE CALCULATIONS ALONG WITH ENERGY | | CALCULATIONS. PLEASE BE SURE TO HAVE THE DESIGNER OF | | RECORD SIGN, DATE AND SEAL THESE AS REQUIRED PER | | 13-103.1.1.1 | | | | 7) NOTE: PLEASE SEE THERE ARE SEVERAL CIRCUITS WHICH | | INDICATE LOADS WHICH EXCEED THE RATING OF THE BREAKERS | | AS SHOWN. 240 | | | | ** PREVIOUS REVIEW NOTES* | | PLEASE CORRELATE ALL LOADS, CONDUCTOR SIZES AND OVER | | CURRENT PROTECTION DEVICES ON PANEL SCHEDULES. PLEASE | | SEE THERE ARE TOO NUMEROUS TO DETAIL EACH,; HOWEVER SEE | | LOADS OF 3.5KW ON 1-POLE 20A BREAKERS, SEE 1-POLE 45AMP | | BREAKERS, SEE #8 AWG ON 20AMP BREAKERS, SEE 30AMP | | BREAKERS ON #12 AWG, 4-POLE BREAKER,ETC ETC. 240.4, | | 310.16 ETC. | | SEE 2005 NEC. | | | | | | 8) NOTE: PLEASE SEE THE SIGNATURE AS SHOWN ON ENERGY | | CALCULATIONS DOES NOT APPEAR TO BE THE SAME AS THE | | SIGNATURE ON FILE FOR THIS DESIGNER OF RECORD. FS | | 471.025/ FAC 61G15-23.002 | | PLEASE SUBMIT A SIGNED, DATED, SEALED, AND NOTARIZED | | LETTER FOR LEGAL SIGNATURE VERIFICATION. | | PLEASE BE SURE THE NOTARY PLACES INFORMATION ON LETTER | | WHICH IS REQUIRED UNDER FS 117.05 | | | | 9) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | REPEAT COMMENTS. | | THIS IS ONLY A NOTICE GIVEN AT THIS TIME. | | PLEASE KNOW THAT DUE TO THE EXTENT OF COMMENTS AND | | NATURE OF COMMENT,FOR ELECTRICALREVIEW AND FOR THAT | | OF OTHER REQUIREMENTS UNDER FLORIDA STATUTES AND | | FLORIDA ADMINISTRATIVE CODE, ONE SET OF PLANS SUBMITTED | | ARE BEING RETAINED BY THIS OFFICE. | | | | 10) NOTE: PLEASE SEE TITLE BLOCK APPEARS TO SHOW | | COMPANY/FIRM AND NOT ONLY THE ARCHITECT AS AN | | INDIVIDUAL. PLEASE PROVIDE CERTIFICATE OF AUTHORIZATION | | NUMBER AS APPLICABLE UNDER FS 481.219, FA C61G1-16.004 | | | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-02-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-02-25 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-02-25 |
Time |
11:56 |
Sent To |
|
|
Notes |
2007-02-25 13:33:51 | *** UNSAT *** | | | | ** PLANS ORIGINALLY SUBMITTED UNDER PERMIT NUMBER | | 05010378 WHICH BECAME *EXPIRED*. | | | | **PLEASE SEE MANY OF THE NOTES ARE THE SAME AS STATED | | IN ORIGINAL REVIEWS AND NUMEROUS NEW COMMENTS DUE TO | | CHANGES MADE TO PLANS WHICH WERE NOT ON PREVIOUS | | REVIEWED PLANS AND NOTES FOR NEW CODE CHANGES. | | | | | | 1) NOTE: PLEASE BE SURE ALL PLANS REFLECT THE LATEST | | ADOPTED CODES PER THE STATE OF FLORIDA. PLEASE SEE THE | | FOLLOWING WHICH ARE CURRENTLY ADOPTED AS OF DECEMBER | | 8TH, 2006. | | 2004 FBC W/ 2006 REVISIONS. THIS WILL AFFECT PLANS | | SUBMITTED | | 2005 NFPA-70 (NEC). THIS WILL AFFECT PLANS SUBMITTED. | | 2002 NFPA-72 | | 2003 NFPA-101 | | | | ** PLEASE SEE THERE ARE SECTIONS OF CODES REFERENCED | | FROM THE 2002 NEC. | | | | 2) NOTE: PLEASE SEE THERE ARE NUMEROUS NOTES ON PLANS | | WHICH REFERENCE ITEMS TO THIS BEING A RESIDENTIAL | | DWELLING? PLEASE ADJUST ALL NOTES ACCORDINGLY. THIS | | SCOPE OF WORK IS NOT FOR A RESIDENTIAL DWELLING. | | | | 3) NOTE:PLEASE SHOW ALL CIRCUITING ON PLANS AND | | CORRELATE WITH PANEL SCHEDULE(S). | | PLEASE SEE THERE ARE A FEW ITEMS ON PLANS WHICH STILL | | DO NOT SHOW THE CIRCUITING. | | PLEASE SEE ALL CIRCUITS WHICH REFLECT TO A PANEL AND | | CIRCUITS WHICH ARE NOT PART OF THE SUBMITTED PANEL | | SCHEDULES SUBMITTED. | | PLEASE ALSO SEE WATER FOUNTAIN HAS BEEN ADDED TO PLANS; | | HOWEVER PLANS DO NOT INDICATE ANY ELECTRICAL | | RECEPTACLES FOR THIS UNIT. | | PLEASE CORRELATE AND COORDINATE ALL. | | FBC 106.1.2, 106.3.5.1.2 | | | | 4) NOTE: PLEASE CORRELATE PANEL SCHEDULE AND COMPLETE | | PANEL SCHEDULE(S) SO THAT ALL ITEMS ON PANEL SCHEDULE | | ARE SPECIFIC TO AREAS AND ROOMS IN WHICH THEY FEED. | | PLEASE SEE COMMENTARY BELOW EXTRACTED FROM THE CODE. | | *SECTION 408.4 WAS REVISED FOR THE 2005 CODE TO REQUIRE | | THAT THE IDENTIFICATION FOR EVERY CIRCUIT SUPPLIED BY A | | PANELBOARD OR SWITCHBOARD BE LEGIBLE AND CLEARLY STATE | | THE SPECIFIC PURPOSE FOR WHICH THE CIRCUIT IS USED. | | CIRCUITS USED FOR THE SAME PURPOSE MUST BE IDENTIFIED | | AS TO THEIR LOCATION. FOR EXAMPLE, SMALL APPLIANCE | | BRANCH CIRCUITS CAN SUPPLY OUTLETS IN THE KITCHEN, | | DINING ROOM, AND KITCHEN COUNTERTOPS. IDENTIFYING THE | | CIRCUITS AS SMALL APPLIANCE BRANCH CIRCUITS IS NOT | | ACCEPTABLE; INSTEAD, THEY SHOULD BE IDENTIFIED AS | | "KITCHEN WALL RECEPTACLES,'' "DINING ROOM FLOOR | | RECEPTACLE,'' OR "KITCHEN COUNTERTOP RECEPTACLES LEFT | | OF SINK.'' CIRCUIT DIRECTORIES CONTAINING MULTIPLE | | ENTRIES WITH ONLY "LIGHTS'' OR "OUTLETS'' DO NOT | | PROVIDE THE SUFFICIENT DETAIL REQUIRED BY THIS | | SECTION. | | | | 5) PLEASE SEE 700.12E FOR EMERGENCY AND EXIT LIGHTS. | | THIS COMMENT WAS MADE ON ALL OTHER REVIEWS UNDER | | PREVIOUS PERMIT APPLICATION; HOWEVER NO CHANGES TO | | PLANS OR CIRCUITING HAVE BEEN MADE. PLEASE SEE OTHER | | AREA ON PLANS WHICH DO NOT SHOW CIRCUITS FOR THESE, | | NOTE TO CIRCUIT TO PANEL HOWEVER THESE SHALL BE | | CIRCUITED TO LOCAL LIGHTING BRANCH CIRCUIT. | | THE BRANCH CIRCUIT FEEDING THE UNIT EQUIPMENT SHALL BE | | THE SAME BRANCH CIRCUIT AS THAT SERVING THE NORMAL | | LIGHTING IN THE AREA AND CONNECTED AHEAD OF ANY LOCAL | | SWITCHES. | | | | 6) NOTE: PLEASE SHOW LOAD CALCULATIONS, PLEASE SHOW | | PER, 220.12, 220.14, 220.42, 220.44 ETC. | | PLEASE ALSO SHOW ALL CONTINUOUS LOADS AT 125% PER | | 215.3, AND 230.42 | | PLEASE SEE LOAD CALCULATIONS SUBMITTED DO NOT ALL | | CORRELATE WITH THE LOADS SHOWN ON PANELS. PLEASE SEE | | SUB PANEL *C*. | | PLEASE SHOW LOAD CALCULATIONS FOR SERVICE AS REQUESTED | | ON PREVIOUS REVIEWS UNDER OLD EXPIRED PERMIT. PLEASE | | SEE ITEMS ON LOAD CALCULATIONS WHICH ARE NOT ON PANEL | | SCHEDULE(S). (SIGN CIRCUIT) | | | | 7) NOTE: PLEASE SEE A COMPLETELY NEW RISER DIAGRAM HAS | | NOW BEEN SUBMITTED AND IS MISSING INFORMATION NEEDED | | FOR CODE COMPLIANCE AND FOR REVIEW. | | PLEASE SEE THE NEXT SEVERAL ITEMS ARE BEING STATED IN | | THIS ONE COMMENT. | | A) PLEASE SEE MISSING AIC RATINGS FOR ALL SERVICE | | EQUIPMENT AND MAINS. | | B) PLEASE SHOW LOCATIONS OF ALL SERVICE EQUIPMENT ON | | PLANS. | | C) PLEASE CORRELATE PLANS AND RISER AND PANELS. PLEASE | | SEE PLANS SHOWS 150A PANEL AS EXISTING, PANEL SCHEDULE | | FOR *C* SHOWS 150AMP AND 125AMP. PLEASE SEE LOAD ON | | THIS PANEL DOES NOT CORRELATE WITH LOAD CALCULATIONS. | | PLEASE SEE PANEL *B* WHICH SHOWS DIFFERENT FEEDERS, | | DIFFERENT OVER CURRENT PROTECTION ETC. | | D) PLEASE SEE SERVICE ENTRANCE CONDUCTORS ARE NOT RATED | | FOR SERVICE. | | ETC. | | 215.5, 310.16, 408.4, 240.4, 110.9, 240.24, 408.7 ETC | | PLEASE SEE 2005 NEC. | | | | 8) NOTE: PLEASE SEE COMPLIANCE WITH THE 2004 FBC | | CHAPTER 13 FOR CONTROL OF LIGHTING PER 13-415.1ABC.1.1, | | .1.2 AND .1.3. | | PLEASE SUBMIT ENERGY CALCULATIONS PER THE 2004 FBC W/ | | 2006 REVISION. PLEASE SEE ENERGY CALCULATIONS SUBMITTED | | ARE FROM THE 2001 FBC. | | PLEASE SEE 13-415.2 FOR LIGHTING PERFORMANCE | | CALCULATIONS ALONG WITH ENERGY CALCULATIONS. PLEASE BE | | SURE TO HAVE THE DESIGNER OF RECORD SIGN, DATE AND SEAL | | THESE AS REQUIRED PER 13-103.1.1.1 | | | | 9) NOTE: PLEASE SEE FLORIDA STATUES 481.221 WHICH | | REQUIRES TO THE ARCHITECT TO ALSO DATE PLANS WHEN | | SIGNING AND SEALING SAID PLANS. | | | | 10) NOTE: PLEASE SEE PLANS SUBMITTED ARE IN FACT | | COLORED PHOTO-COPIES OF PLANS STAMPED PREVIOUSLY BY THE | | CITY ZONING REVIEWER AND PALM BEACH COUNTY FOR IMPACT | | FEES. PLEASE KNOW THAT THESE SHALL BE ORIGINAL AND MAY | | NOT MAKE CHANGES TO PLANS AND COLOR PHOTO-COPY PLANS. | | PLANS WILL BE REQUIRED TO GO BACK TO HISTORIC, ZONING, | | AND PALM BEACH COUNTY AS PERMIT APPLICATION IS NOW | | UNDER NEW PALM BEACH COUNTY IMPACT FEE SCHEDULE AS OF | | JAN 1ST, 2006. | | | | 11) NOTE: PLEASE SEE PLANS WHICH STILL STATE *CORAL KEY | | DESIGN*. PLEASE KNOW AS PER FS481.229, A DESIGNER, | | DRAFTING, CADD DESIGN COMPANY MAY NOT DESIGN PLANS | | FORCOMMERICAL/ PUBLIC USE OF THIS NATURE. THIS HAS BEEN | | CONFIRMED WITH THE STATE OF FLORIDA LEGAL COUNSEL TO | | THE BOARD OF ARCHITECTS AND THIS COMMENT WAS MADE ON | | PREVIOUS REVIEWS UNDER THE EXOIRED PERMIT. | | FURTHER CONTACT MAY BE DONE WITH STATE PROSECUTOR | | MR.DAVID MINACCI, OR STATE INVESTIGATOR MR. LES SMITH. | | | | 12) NOTE: PLEASE CORRELATE ALL LOADS, CONDUCTOR SIZES | | AND OVER CURRENT PROTECTION DEVICES ON PANEL | | SCHEDULES. | | PLEASE SEE THERE ARE TOO NUMEROUS TO DETAIL EACH,; | | HOWEVER SEE LOADS OF 3.5KW ON 1-POLE 20A BREAKERS, SEE | | 1-POLE 45AMP BREAKERS, SEE #8 AWG ON 20AMP BREAKERS, | | SEE 30AMP BREAKERS ON #12 AWG, 4-POLE BREAKER,ETC | | ETC. | | 240.4, 310.16 ETC. | | SEE 2005 NEC. | | | | 13) NOTE: PLEASE SEE MISSING A/C UNITS AND THERE | | REQUIRED DISCONNECTING MEANS PER 440.11. PLEASE SEE | | MISSING CU DISCONNECT, PLEASE SEE MISSING AHU | | DISCONNECT ETC. PLEASE SEE SOME SHOWN WITH A RECEPTACLE | | FOR UNIT TO PLUG-IN WHICH IS PROHIBITED. | | 422.30, 422.31, 440.11 ETC. | | | | 14) NOTE: PLEASE SEE AHU'S WITH OVER CURRENT PROTECTION | | WHICH IS TOO HIGH FOR THE 5KW LOAD SHOWN. AHU'S #1 AND | | #2. | | 240.4, 310.16, AND FBC 106.1.2, 106.3.5.1.2 FOR | | COORDINATION. | | | | | | 15) NOTE: PLEASE KNOW THAT DUE TO THE EXTENT OF | | COMMENTS AND NATURE OF COMMENT,FOR ELECTRICALREVIEW | | AND FOR THAT OF OTHER REQUIREMENTS UNDER FLORIDA | | STATUTES AND FLORIDA ADMINISTRATIVE CODE, ONE SET OF | | PLANS SUBMITTED ARE BEING RETAINED BY THIS OFFICE. | | | | 16) NOTE: PLEASE SEE THAT THE NEWLARGER ADA BATHROOM | | SHALL CONTAIN A BATTERY BACK UP LIGHTING FIXTURE FO | | SOME TYPE. LS 101 7.8, 7.9. PLEASE CIRCUIT PER 700.12 | | FO TEH NEC. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
F |
Date |
2007-10-25 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-10-25 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-10-25 |
Time |
12:16 |
Sent To |
|
|
Notes |
2007-10-25 12:39:59 | *****UNSAT***** | | | | THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN | | THE OTHER REVIEWERS AND THE FOLLOWING FIRE REVIEW | | COMMENTS HAVE BEEN SATISFIED: | | | | A.SHOW THE LOCATION OF THE 2A10BC FIRE | | EXTINGUISHER(S).OLD COMMENT | | | | B.ON SHEET 2, ONLY ONE EMERGENCY LIGHT IS SHOWN IN | | THE PROPOSED FELLOWSHIP HALL WHEREAS, TWO EMERGENCY | | LIGHTS ARE SHOWN ON THE M-1 SHEET. PLEASE RECTIFY. NEW | | COMMENT | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE ON THE PLAN EACH ITEM WAS | | ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2007-07-23 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-07-23 |
Time |
12:48 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-07-23 |
Time |
12:32 |
Sent To |
|
|
Notes |
2007-07-23 12:35:06 | *****DENIED***** | | | | THE FOLLOWING COMMENTS FROM THE PREVIOUS PLAN REVIEW | | STILL NEED TO BE ADDRESSED: | | | | | | 4.INDICATE THE OCCUPANT LOAD FOR THE PROPOSED | | STRUCTURE BASED UPON THE OCCUPANT LOAD FACTORS THAT ARE | | CHARACTERISTIC OF THE USE OF THE SPACE OR DETERMINED AS | | THE MAXIMUM PROBABLE POPULATION OF THE SPACE UNDER | | CONSIDERATION, WHICHEVER IS GREATER. | | | | 5.ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM AN AREA | | HAVING AN OCCUPANT LOAD OF 100 OR MORE SHALL BE | | PROVIDED WITH PANIC HARDWARE OR FIRE EXIT HARDWARE. | | | | 6.PLEASE PROVIDE A LAYOUT SHOWING THE ARRANGEMENT OF | | FURNISHINGS, TABLES, SEATS, AND(OR) EQUIPMENT. | | | | 7.SHOW THE LOCATION OF THE 2A10BC FIRE | | EXTINGUISHER(S). | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE ON THE PLAN EACH ITEM WAS | | ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2007-03-21 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-03-21 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-03-21 |
Time |
11:55 |
Sent To |
FIRE |
|
Notes |
2007-03-21 14:20:14 | *****DENIED***** | | | | | | 1.THE COMPLETE ADDRESS OF WHERE THE SCOPE OF WORK | | WILL BE CONDUCTED SHALL BE IN THE TITLE BLOCK OF EACH | | SUBMITTED PLAN SHEET. | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 3.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL NOT | | INTERFERE OR HINDER EMERGENCY RESPONSE ACCESS TO THE | | SAID PROPERTY OR VICINITY THEREOF. | | | | 4.INDICATE THE OCCUPANT LOAD FOR THE PROPOSED | | STRUCTURE BASED UPON THE OCCUPANT LOAD FACTORS THAT ARE | | CHARACTERISTIC OF THE USE OF THE SPACE OR DETERMINED AS | | THE MAXIMUM PROBABLE POPULATION OF THE SPACE UNDER | | CONSIDERATION, WHICHEVER IS GREATER. | | | | 5.ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM AN AREA | | HAVING AN OCCUPANT LOAD OF 100 OR MORE SHALL BE | | PROVIDED WITH PANIC HARDWARE OR FIRE EXIT HARDWARE. | | | | 6.PLEASE PROVIDE A LAYOUT SHOWING THE ARRANGEMENT OF | | FURNISHINGS, TABLES, SEATS, AND(OR) EQUIPMENT. | | | | 7.SHOW THE LOCATION OF THE 2A10BC FIRE | | EXTINGUISHER(S). | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-09-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-27 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-27 |
Time |
10:18 |
Sent To |
|
|
Notes |
2007-10-17 12:02:25 | TO "COMM" BD#10 | 2007-09-27 10:19:04 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-06-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-07 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-07 |
Time |
11:11 |
Sent To |
|
|
Notes |
2007-06-21 14:56:30 | TO "COMM" BD#64 | 2007-06-07 11:12:17 | WATIING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-03-21 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-03-21 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-02-06 |
Time |
16:35 |
Sent To |
|
|
Notes |
2007-02-13 14:50:23 | TO "COMM" BD#16 | 2007-02-06 16:35:25 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2007-11-11 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-11-11 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-11-11 |
Time |
14:08 |
Sent To |
|
|
Notes |
2007-11-11 15:02:28 | REVIEW #: 3RD | | ACTION: DENIED | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | 1. FLOOR PLAN CALLS FOR A TOTAL OF 930 CFM. A FOUR TON | | AHU WILL PRODUCE 1600 CFM. WHERE WILL THE OTHER 670 CFM | | GO? AN AIR DISTRIBUTION SYSTEM SHALL BE DESIGNED AND | | INSTALLED TO SUPPLY THE REQUIRED DISTRIBUTION OF AIR IN | | ACCORDANCE WITH FBC,M 603.1. | | | | 2. THIS COMMENT WAS NOT ADDRESSED. NO OUTSIDE AIR | | CALCULATIONS PROVIDED. NO OUTSIDE AIR VENTILATION SHOWN | | ON PLANS. SHOW COMPLIANCE WITH FBC,M 403.3. | | | | 3. THIS COMMENT WAS PARTIALLY ADDRESSED. CFM OF BATH | | EXHAUST FANS STILL NOT SHOWN ON PLANS. SHOW COMPLIANCE | | WITH FBC,M 403.3. | | | | 4. THIS COMMENT WAS NOT ADDRESSED. SHOW COMPLIANCE WITH | | FBC,M 602.2.1 | | | | 5. THIS COMMENT WAS NOT ADEQUATELY ADDRESSED. LOCATION | | OF CONDENSATE DISPOSAL NOT SHOWN. A SHUTOFF SWITCH ON A | | CONDENSATE PUMP IS NOT A CODE COMPLIANT MEANS OF | | AUXILIARY DRAIN PROTECTION. COMPLY WITH ONE OF THE | | ALLOWED METHODS AS LISTED IN FBC,M SECTION 307.2.3. | | | | 6. OK | | | | 7. NOW ENERGY CALCULATIONS SHOW 4.8 TONS OF AIR AND | | MANUAL N SHOWS 5 TONS OF AIR, BUT EQUIPMENT LISTED IS | | ONLY 4 TONS. PLEASE COORDINATE ALL DOCUMENTATION AND | | EQUIPMENT LISTING. | | | | 8. OK | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-06-29 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-06-29 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-06-28 |
Time |
19:57 |
Sent To |
|
|
Notes |
2007-06-29 15:08:34 | -----------------DENIED----------------- | | FBC 2004 CODE FAMILY W/ 2006 REVISIONS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | 1. PLEASE PROVIDE CFMS FOR ALL SUPPLY DROPS, REGISTERS | | AND GRILLS. FBC 106.1.2 | | | | 2. PLEASE PROVIDE OUTDOOR AIR CALCULATIONS SHOWING SIZE | | AND LOCATION OF OUTDOOR AIR SOURCE, OCCUPANCY | | CLASIFICATION, OCCUPANT LOAD AND CFM OF OUTDOOR AIR | | REQUIRED PER FBC,M 403.3 AND FBC 106.3.5.1.4 | | | | 3. PLEASE SHOW CFM, DUCT SIZE AND DISCHARGE LOCATION | | FOR TOILET ROOM EXHAUST FANS PER FBC,M 401.5, TABLE | | 403.3 AND FBC 106.3.5.1.4 | | | | 4. A/C CLOSET LOOKS TO BE USED AS A PLENUM. DRAIN LINE | | MATERIAL IS SHOWN ON PLAN TO BE 3/4" PVC WHICH MAY NOT | | BE USED IN A PLENUM PER FBC,M 602.2.1. | | | | 5. PLEASE SHOW MEANS AND LOCATION OF CONDENSATE | | DISPOSAL PER FBC,M 307.2.1 AND MEANS OF SECONDARY OR | | AUXILIARY DRAIN PROTECTION PER FBC,M 307.2.3. ALSO, | | PLEASE SHOW ROUTING OF REFRIGERANT LINES. ARE THEY | | OVERHEAD OR UNDERGROUND? FBC,M 1107.2.1 | | | | 6. PLEASE PROVIDE AN EQUIPMENT SCHEDULE ON PLANS | | INCLUDING SIZE, SEER, MODEL NUMBERS, HEAT STRIP AND | | ELQUIPMENT ELECTRICAL RATINGS. FBC 106.3.5.1.3 | | | | 7. ENERGY CALCULATIONS STATE MAX TONNAGE AT 4, BUT | | PLANS CALL FOR 5 TONS OF COOLING. PLEASE SHOW | | CORRELATION BETWEEN PLANS AND ENERGY CALCULATIONS. | | NOTE: MANUAL N, COOLING LOADS AND ENERGY CALCULATIONS | | MAY NEED TO BE ADJUSTED ONCE ABOVE ADJUSTMENTS ARE | | MADE. | | | | 8. WHAT IS THE PURPOSE OF TWO RETURN GRILLS CONNECTED | | BY A 14" DUCT IN THE MIDDLE OF A NON-SEPARATED SPACE? | | WHAT IS THE SIZE OF THE GRILLS? WILL THERE BE SOME SORT | | OF PARTITION DIVIDING THE SPACE? THERE IS NONE SHOWN ON | | A/C OR ARCHITECTURAL PLANS. IF THERE IS TO BE A | | PARTITION, THE RETURN DUCT IS TOO SMALL TO MEET THE | | BALANCED RETURN EXCEPTIONS OF FBC,M 601.4. THE RETURN | | DUCT WOULD NEED TO BE AT LEAST 16" TO CLAIM THE | | EXCEPTION. IF THERE IS TO BE A FOLDING OR ACCORDIAN | | STYLE PARTITION, PLEASE CHECK FOR STRUCTURAL | | REQUIREMEMNTS, AS NONE ARE SHOWN ON PLANS AT THIS | | TIME. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | RONALD J REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-03-14 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-03-14 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-03-14 |
Time |
09:00 |
Sent To |
|
|
Notes |
2007-03-14 09:12:57 | ---------------DENIED------------------ | | | | NO INFORMATION WAS SUBMITTED FOR MECHANICAL SYSTEMS. | | PLEASE SUBMIT PLANS SHOWING ALL AIR CONDITIONING AND | | VENTILLATION WORK, INCLUDING ANY NECESSARY DETAIL | | DRAWINGS, EQUIPMENT SCHEDULE AND UPDATED ENERGY | | CALCULATIONS. | | | | | | RONALD J REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2007-12-01 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-12-01 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-12-01 |
Time |
11:03 |
Sent To |
|
|
Notes |
2007-12-01 11:31:51 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | FBC-2004 BUILDING | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | ****FROM PREVIOUS REVIEW**** | | | | ******FROM PREVIOUS REVIEWS: | | | | 1. OK | | 2. OK | | 3. OK | | 4. OK | | 5. OK | | 6. OK | | | | 7. SHT 2 SHOW THE CLEAR FLOOR SPACE FOR ALL ACCESSIBLE | | FIXTURES ON THE FLOOR PLAN. THE DRINKING FOUNTAIN IS | | REQUIRED TO BE 15" OFF THE WALL AND CENTERED ON THE 30" | | WIDTH OF THE CLEAR FLOOR SPACE. AS SHOW THE SERVICE | | SINK IS ENCROACHING INTO THE CLEAR FLOOR SPACE OF THE | | DRINKING FOUNTAIN. | | ****NO RESPONSE/NOT ADDRESSED. | | ******RESPONSE NOTED, BUT THE CLEAR FLOOR SPACE IS NOT | | SHOWN ON THE FLOOR PLAN FOR THE FIXTURES. | | | | 8. THE ACCESSIBLE STALL SHALL COMPLY WITH FIGURE | | 11-30E. A LAV IS REQUIRED IN THE STALL AND 5' OF CLEAR | | FLOOR SPACE IS REQUIRED FROM THE WALL ADJACENT TO THE | | WATER CLOSET AND UP TO THE SIDE OF THE LAV. SECTION | | 11-4.17.3 EXCEPTIONS (1)(2). | | ****NO RESPONSE/NOT ADDRESSED. | | ******RESPONSE NOTED, BUT THE LAV SHALL BE MINIMUM 15" | | OFF THE WALL TO THE CENTER OF THE FIXTURE TO BE | | CENTERED ON THE 30" WIDTH OF THE CLEAR FLOOR SPACE. | | (RECOMMEND CHANGE THE LAYOUT OF THE ACCESSIBLE STALL IN | | THE WOMEN'S TOILET ROOM. THE LAV CAN BE BEHIND THE W/C | | OF THE MEN'S TOILET ROOM AND COMPLY). | | | | 9. OK | | | | ***********NEW COMMENTS*********** | | | | 1B. SUBMIT A DETAIL FOR THE W/C'S SHOW COMPLIANCE WITH | | THE FOLLOWING: | | A. 11-4.16.2 CLEAR FLOOR SPACE | | B. 11-4.16.3 HEIGHT | | C. 11-4.16.4 GRAB BARS | | D. 11-4.16.5 FLUSH CONTROLS | | E. 11-4.16.6 DISPENSERS | | ******NO RESPONSE, NOT ADDRESSED | | | | 2B. SUBMIT A DETAIL FOR THE STALLS SHOWING COMPLIANCE | | WITH THE FOLLOWING: | | A. 11-4.17.3 SIZE & ARRANGEMENT (EXCEPTION NEW | | CONSTRUCTION) (FIG 30E) | | ******RESPONSE NOTED, BUT THE LAV IS NOT SHOWN AS 15" | | OFF THE WALL TO THE CENTERLINE OF THE FIXTURE AS | | REQUIRED TO BE CENTERED ON THE FIXTURE. | | | | 3B. SUBMIT A DETAIL FOR THE DRINKING FOUNTAIN SHOWING | | COMPLIANCE WITH THE FOLLOWING: | | A. 11-4.15.2 SPOUT HEIGHT | | B. 11-4.15.3 SPOUT LOCATION | | C. 11-4.15.5(1) CLEARANCES | | D. 11-4.15.5(2) CLEAR FLOOR SPACE | | E. 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING. | | ******NO RESPONSE, NOT ADDRESSED. | | | | 4B. SUBMIT A DETAIL FOR THE LAVS SHOWING COMPLIANCE | | WITH THE FOLLOWING: | | A. 11-4.19.2 HEIGHT & CLEARANCES | | B. 11-4.19.3 CLEAR FLOOR SPACE | | C. 11-4.19.4 EXPOSED PIPES & SURFACES | | D. 11-4.19.5 FAUCETS | | E. 11-4.19.6 MIRRORS | | ******NO RESPONSE, NOT ADDRESSED. | | | | 5B. OK | | | | 6B. SUBMIT A DETAIL FOR THE SINK SHOWING COMPLIANCE | | WITH THE FOLLOWING: | | A. 11-4.24.2 HEIGHT | | B. 11-4.24.3 KNEE CLEARANCE | | C. 11-4.24.4 SINK DEPTH | | D. 11-4.24.5 CLEAR FLOOR SPACE - FORWARD APPROACH | | REQUIRED MAX 19" UNDERNEATH THE SINK. -CABINET DOORS | | ARE NOT ALLOWED. | | E. 11-4.24.6 EXPOSED PIPES & SURFACES | | F. 11-4.24.7 FAUCETS | | ******RESPONSE NOTED, NOT ADDRESSED. | | | | 7B. OK | | | | *****NEW COMMENTS (3RD REVIEW)***** | | | | 1C. THE SANITARY AND WATER RISER DIAGRAMS DO NOT | | REFLECT THE FLOOR PLAN. (SEE EXAMPLE OF A SANT RISER | | DIAGRAM THAT REFLECT THE FLOOR PLAN). PLEASE SUBMIT | | SANT AND WATER RISERS THAT REFLECT THE FLOOR PLAN AFTER | | THE LAV CHANGE IN THE ACCESSIBLE STALL IN THE WOMENS | | TOILET ROOM. SECTION 106.3.5.1.3. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | ****NO RESPONSE/NOT ADDRESSED | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-07-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-07-14 |
Time |
07:06 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-07-14 |
Time |
07:06 |
Sent To |
|
|
Notes |
2007-07-14 07:47:52 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | FBC-2004 BUILDING | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | ****FROM PREVIOUS REVIEW**** | | | | 1. OK | | | | 2. SHOW THE SQUARE FOOTAGE OF THE BUILDING ON THE | | PLANS. SECTION 106.1.2. | | ****NO RESPONSE/NOT ADDRESSED | | | | 3. OK | | 4. OK | | | | 5. SUBMIT CALCULATIONS FOR MINIMUM FACILITIES. AS SHOWN | | THERE APPROXIMATELY 1,158SSF NET DIVIDED BY 5 NET AS | | INDICATED IN TABLE 1004.1.2 THERE ARE 232 OCCUPANTS. | | PER TABLE 403.1 232 DIVIDED BY 2 EQUALS 116 MEN - 116 | | WOMEN. DIVIDED BY 40 EQUALS 2.9 OR 3 WATER CLOSETS EACH | | REQUIRED FOR MEN AND WOMEN, WITH 2 LAVS EACH FOR MEN | | AND WOMEN. | | ****NO RESPONSE/NOT ADDRESSED | | | | 6. OK | | | | 7. SHT 2 SHOW THE CLEAR FLOOR SPACE FOR ALL ACCESSIBLE | | FIXTURES ON THE FLOOR PLAN. THE DRINKING FOUNTAIN IS | | REQUIRED TO BE 15" OFF THE WALL AND CENTERED ON THE 30" | | WIDTH OF THE CLEAR FLOOR SPACE. AS SHOW THE SERVICE | | SINK IS ENCROACHING INTO THE CLEAR FLOOR SPACE OF THE | | DRINKING FOUNTAIN. | | ****NO RESPONSE/NOT ADDRESSED | | | | 8. THE ACCESSIBLE STALL SHALL COMPLY WITH FIGURE | | 11-30E. A LAV IS REQUIRED IN THE STALL AND 5' OF CLEAR | | FLOOR SPACE IS REQUIRED FROM THE WALL ADJACENT TO THE | | WATER CLOSET AND UP TO THE SIDE OF THE LAV. SECTION | | 11-4.17.3 EXCEPTIONS (1)(2). | | ****NO RESPONSE/NOT ADDRESSED | | | | 9. OK | | | | ***********NEW COMMENTS*********** | | | | 1B. SUBMIT A DETAIL FOR THE W/C'S SHOW COMPLIANCE WITH | | THE FOLLOWING: | | A. 11-4.16.2 CLEAR FLOOR SPACE | | B. 11-4.16.3 HEIGHT | | C. 11-4.16.4 GRAB BARS | | D. 11-4.16.5 FLUSH CONTROLS | | E. 11-4.16.6 DISPENSERS | | | | 2B. SUBMIT A DETAIL FOR THE STALLS SHOWING COMPLIANCE | | WITH THE FOLLOWING: | | A. 11-4.17.3 SIZE & ARRANGEMENT (EXCEPTION NEW | | CONSTRUCTION) (FIG 30E) | | | | 3B. SUBMIT A DETAIL FOR THE DRINKING FOUNTAIN SHOWING | | COMPLIANCE WITH THE FOLLOWING: | | A. 11-4.15.2 SPOUT HEIGHT | | B. 11-4.15.3 SPOUT LOCATION | | C. 11-4.15.5(1) CLEARANCES | | D. 11-4.15.5(2) CLEAR FLOOR SPACE | | E. 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING. | | | | 4B. SUBMIT A DETAIL FOR THE LAVS SHOWING COMPLIANCE | | WITH THE FOLLOWING: | | A. 11-4.19.2 HEIGHT & CLEARANCES | | B. 11-4.19.3 CLEAR FLOOR SPACE | | C. 11-4.19.4 EXPOSED PIPES & SURFACES | | D. 11-4.19.5 FAUCETS | | E. 11-4.19.6 MIRRORS | | | | 5B. PER SECTION 11-4.22.3 SHOW A 5' TURNING AREA IN THE | | TOILET ROOMS. | | | | 6B. SUBMIT A DETAIL FOR THE SINK SHOWING COMPLIANCE | | WITH THE FOLLOWING: | | A. 11-4.24.2 HEIGHT | | B. 11-4.24.3 KNEE CLEARANCE | | C. 11-4.24.4 SINK DEPTH | | D. 11-4.24.5 CLEAR FLOOR SPACE - FORWARD APPROACH | | REQUIRED MAX 19" UNDERNEATH THE SINK. -CABINET DOORS | | ARE NOT ALLOWED. | | E. 11-4.24.6 EXPOSED PIPES & SURFACES | | F. 11-4.24.7 FAUCETS | | | | 7B. SUBMIT A PLUMBING FLOOR PLAN INDICATING THE | | CONNECTIONS FOR THE SANITARY BUILDING DRAIN AND THE | | WATER SERVICE FOR THE ADDITION. SECTION 106.1.2. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | ****NO RESPONSE/NOT ADDRESSED | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-03-10 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-03-10 |
Time |
05:50 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-03-09 |
Time |
18:59 |
Sent To |
|
|
Notes |
2007-03-10 07:13:02 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | FBC-2004 BUILDING | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1. INDICATE THE CODE IN EFFECT FOR THE DESIGN OF THE | | BUILDING ON THE PLANS. (FBC-2004 W/06 AMENDMENTS). | | SECTION 106.1.2. | | | | 2. SHOW THE SQUARE FOOTAGE OF THE BUILDING ON THE | | PLANS. SECTION 106.1.2. | | | | 3. SHT 1 THE SANITARY RISER DIAGRAM DOES NOT REFLECT | | THE FLOOR PLAN. THE FIXTURE LAYOUT OF THE RISER DOES | | NOT REFLECT THE FIXTURE LAYOUT OF THE FLOOR PLAN AND | | THE SERVICE SINK IS NOT INDICATED ON THE RISER | | ISOMETRIC DIAGRAM. PLEASE CORRELATE THE RISER AND THE | | FLOOR PLAN. SECTION 106.1.1. (SEE EXAMPLE OF A RISER | | DIAGRAM THAT REFLECTS THE EXISTING FLOOR PLAN AS | | SHOWN). | | | | 4. SHT 1 THE WATER RISER DIAGRAM DOES NOT REFLECT THE | | FLOOR PLAN. PLEASE CORRELATE THE RISER AND THE FLOOR | | PLAN. SECTION 106.1.1. | | | | 5. SUBMIT CALCULATIONS FOR MINIMUM FACILITIES. AS SHOWN | | THERE APPROXIMATELY 1,158SSF NET DIVIDED BY 5 NET AS | | INDICATED IN TABLE 1004.1.2 THERE ARE 232 OCCUPANTS. | | PER TABLE 403.1 232 DIVIDED BY 2 EQUALS 116 MEN - 116 | | WOMEN. DIVIDED BY 40 EQUALS 2.9 OR 3 WATER CLOSETS EACH | | REQUIRED FOR MEN AND WOMEN, WITH 2 LAVS EACH FOR MEN | | AND WOMEN. | | | | 6. ALL SHEETS, THE ADDRESS OF THE ARCHITECT IS REQUIRED | | IN THE TITLE BLOCK. FAC 61G1-16.004(1) & FS 481.2055. | | (SEE ATTACHED SHEET). | | | | 7. SHT 2 SHOW THE CLEAR FLOOR SPACE FOR ALL ACCESSIBLE | | FIXTURES ON THE FLOOR PLAN. THE DRINKING FOUNTAIN IS | | REQUIRED TO BE 15" OFF THE WALL AND CENTERED ON THE 30" | | WIDTH OF THE CLEAR FLOOR SPACE. AS SHOW THE SERVICE | | SINK IS ENCROACHING INTO THE CLEAR FLOOR SPACE OF THE | | DRINKING FOUNTAIN. | | | | 8. THE ACCESSIBLE STALL SHALL COMPLY WITH FIGURE | | 11-30E. A LAV IS REQUIRED IN THE STALL AND 5' OF CLEAR | | FLOOR SPACE IS REQUIRED FROM THE WALL ADJACENT TO THE | | WATER CLOSET AND UP TO THE SIDE OF THE LAV. SECTION | | 11-4.17.3 EXCEPTIONS (1)(2). | | | | 9. PLEASE SHOW COMPLIANCE WITH THE FOLLOWING FOR THE | | LAVS: | | A. 11-4.19.4 EXPOSED PIPES & SURFACES | | B. 11-4.19.5 FAUCETS | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2007-10-25 |
|
|
Cont ID |
|
Sent By |
mflis |
Date |
2007-10-25 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
mflis |
Date |
2007-10-25 |
Time |
11:35 |
Sent To |
|
|
Notes |
2007-10-25 11:37:35 | ZONING REVIEW: FAILED | | | | ** PREVIOUS APPROVAL INCLUDED PROVISO; RESUBMITTED | | DRAWINGS DID NOT ADDRESS THESE CONDITIONS; NEXT | | SUBMITTAL SHOULD SHOW MODIFICATIONS** | | | | 1) PLEASE MODIFY SITE PLAN TO ALIGN CURB CUT AND 24'-0" | | WIDE PARKING LOT DRIVE. | | 2) PLANS PRESENTLY ARE INCORRECT, SHOWING CARS ENTERING | | OVER SIDEWALK | | 3) CURB CUT SHOULD BE MOVED WEST FOR CORRECT ALIGNMENT | | 4) ACCURATE LANDSCAPE PLANS ARE NOT PROVIDED; ZONING | | WILL REVIEW INSTALLATION PER DAC APPROVAL | | | | MATT FLIS - 822-1445 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-07-03 |
|
|
Cont ID |
|
Sent By |
mflis |
Date |
2007-07-03 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
mflis |
Date |
2007-07-03 |
Time |
08:57 |
Sent To |
|
|
Notes |
2007-07-03 09:00:55 | ZONING REVIEW: APPROVED WITH PROVISO: | | | | 1) PLEASE MODIFY SITE PLAN TO ALIGN CURB CUT AND 24'-0" | | WIDE PARKING LOT DRIVE. | | | | * PLANS PRESENTLY ARE INCORRECT, SHOWING CARS ENTERING | | OVER SIDEWALK | | * CURB CUT SHOULD BE MOVED WEST FOR CORRECT ALIGNMENT | | * ACCURATE LANDSCAPE PLANS ARE NOT PROVIDED; ZONING | | WILL REVIEW INSTALLATION | | | | MATT FLIS - 822-1445 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-02-23 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2007-02-23 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2007-02-23 |
Time |
16:19 |
Sent To |
|
|
Notes |
2007-02-23 16:20:45 | PLEASE MODIFY THE PARKING ACCORDING WITH CONDITIONS | | IMPOSED BY DAC APPROVAL. |
|
|
|