Plan Review Details - Permit 07020065
Plan Review Stops For Permit 07020065
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2007-06-04 Cont ID  
Sent By lursu Date 2007-06-01 Time 08:54 Rev Time 0.00
Received By lursu Date 2007-06-04 Time 13:58 Sent To  
Notes
2007-06-01 09:40:35THE SURVEY PLAN WAS SUPPLIED WITH THE PERMIT
 APPLICATION AND BASED ON THAT ,THE NEW HOUSE IS BEING
 BUILT ON LOT 8 ,AND THE SITE ADDRESS REMAINS AS 1031
 11TH ST , WEST PALM BEACH , FL 33401.THE MINOR
 SUBDIVISION WAS APPROVED BY P&Z.THE OTHER NEW LOT
 FORMED , LOT 9 , WILL RECEIVE A NEW SITE ADDRESS
 .PLEASE CONTACT THIS OFFICE FOR MORE INFORMATION.
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-05-29 Cont ID  
Sent By jgomez Date 2007-05-29 Time 14:05 Rev Time 0.00
Received By jgomez Date 2007-05-29 Time 07:38 Sent To PC
Notes
2007-05-29 14:30:35BUILDING REVIEW SECOND CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 2- PAY IMPACT FEES TO PALM BEACH COUNTY.BRING BACK
 STAMPED PLANS AND COPY OF PAID RECEIPT.
  
 3- OWES $2527.82 FOR UPDATED VALUATION, RADON FEES AND
 OUTSTANDING BALANCE AT TIME OF PERMIT APPLICATION.
  
 4- ENERGY CALCULATIONS:
 A) REVISE OVERHANG HEIGHT AND OVERHANG LENGTH. SEE
 PLANS AND REVISE AS REQUIRED.
  
 B) COMPLETE ALL INFORMATION ON TOP OF FORM.
 INCLUDING BUILDER INFORMATION.
  
 C) OWNER/AGENT TO SIGN AND DATE AT BOTTOM OF FORM.
  
 5- PROVIDE COMPLETE INFORMATIONFOR STORM SHUTTERS.
 PROVIDEPRODUCT APPROVAL AND COMPLETE INSTALLATION
 SCHEDULE.SEE ATTACHED SAMPLE.ALSO,CIRCLE ON STORM
 SHUTTERS DRAWINGS SPECIFIC MOUNTING CONDITIONS,
 SPECIFIC ANCHOR TYPE AND SPACING ACCORDING TO THE
 DESIGN PRESSURES, EDGE DISTANCE, CONNECTION TYPE AND
 STRUCTURE TO BE ATTACHED TO (CONCRETE BLOCK OR
 CONCRETE). SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
 ***NOTE: DESIGNER OF RECORD TO REVIEW AND APPROVE (NOT
 SIGNING AND SEALIING)IN WRITING ALL PRODUCT APPROVALS
 AS REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC
 2004.
  
 6-A) SURVEY DOESN'T MATCH FLOOR PLANS.
  
 B) CLARIFY WHICH LOT IS GOING TO BE BUILT, LOT 8 OR
 9.REVISE INFORMATION WITH PERMIT CLERK.
  
 C) CONTACT LILYAT (561)822-1239 TO CLARIFY CORRECT
 LOT, PARCEL ID AND HOUSE NUMBER.
  
 D) PROPERTY IS LOCATED ON FLOOD ZONE "B", NOT"C".
 REVISE SURVEY AS REQUIRED.
  
 7- A)REVISE PLYWOODSHEATHING NAILING SCHEDULE ON
 SHEET S-3.SEE SEC. R803.2.3.1 OF 2004 FLORIDA
 RESIDENTIAL CODE AND REVISE AS REQUIRED.
  
 B) ALSO, REVISE NOTE REGARDING RING SHANK NAILS NOT
 REQUIRED FOR MEAN ROOF HEIGHTS LESS THAN 25'-0" HIGH.
 SEE SEC. ABOVE AND REVISE AS REQUIRED.
  
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-23 Cont ID  
Sent By jgomez Date 2007-03-23 Time 12:38 Rev Time 0.00
Received By jgomez Date 2007-03-23 Time 12:38 Sent To  
Notes
2007-03-23 13:00:51BUILDING REVIEWCHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC 713.13
 FLORIDA STATUTES.
  
 2- BRING PLANS TO PALM BEACH COUNTY FOR IMPACT FEES.
 BRING BACK STAMPED PLANS AND COPY OF PAID RECEIPT.
 ***NOTE: MAKE SURE CORRECT BUILDING AREA IS SHOWN ON
 PLANS.
  
 3- SHEET A-1.0:
 A) REVISE TYPE OF CONSTRUCTION. SEE SEC. 602 FBC
 2004. TYPE OF CONSTRUCTION SHOWN ON PLANS APPLIES TO
 TYPE IIIB.
 B) ADD 2004 FLORIDA RESIDENTIAL CODE, WHICH IS THE
 ONE THAT APPLIES TO SINGLE FAMILY RESIDENCES.
 C) AREA CALCULATIONS ON SHEET A-1.0 ARE DIFFERENT
 THAN THOSE SHOWN ON SHEET A-1.1. REVISE AS REQUIRED.
  
 4- ENERGY CALCULATIONS:
 A) REVISE OVERHANG LENGTH AND HEIGHT. SEE PLANS.
 B) MAKE SURE A/C AREA MATCHES PLANS.
 C) COMPLETE ALL INFORMATION ON TOP OF FORM.
  
 5- PROVIDE COMPLETE INFORMATION FOR STORM SHUTTERS.
 PROVIDE PRODUCT APPROVAL AND COMPLETE INSTALLATION
 SCHEDULE. SEE ATTACHED SAMPLE OF INSTALLATION
 SCHEDULE.
  
 *** NOTE: DESIGNER OF RECORD TO REVIEW AND APPROVE IN
 WRITING PRODUCT APPROVAL AS REQUIRED BY SEC. 106.3.3
 CITY AMENDMENTS TO FBC 2004.
  
 6- BUILDING VALUATION AND RADON FEES WILL BE UPDATED
 WHEN CORRECT FLOOR AREAS ARE PROVIDED.
  
 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72
 FOR:
 A) INSWING ENTRY DOOR AS SHOWN ON PLANS.
 *** NOTE: PLEASE MAKE SURE DRAWINGS ARE LEGIBLE.
 B) IMPACT SLIDING GLASS DOORS AS SPECIFIED ON
 PLANS.
 *** NOTE: SEE SIZE OF DOORS SPECIFIED ON PLANS.
 C) DOUBLE GARAGE DOOR AS SHOWN ON EXTERIOR
 ELEVATION.
 D) ASPHALT SHINGLES.NOA #04-0305.03 EXPIRED ON
 02/21/07.
 E) SINGLE HUNG WINDOWS. NEED LEGIBLE DRAWINGS. F)
 COLONIAL SHUTTERS SHOWN ON EXTERIOR ELEVATIONS.
  
 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 9- ARCHITECT TO PROVIDE ALL HIS INFORMATION AND FIRM'S
 REGISTRATION NUMBERAS REQUIRED BY SEC. 61G1-16.004 OF
 FLORIDA ADMINISTRATIVE CODE.
  
 10- SURVEY TO HAVE ORIGINAL SIGNATURE AS REQUIRED BY
 CHAPTER 472 FLORIDA STATUTES.
  
 11- SHEET A-2.1:
 A) FLOOR PLAN CALLS FOR ONE 16'X7' GARAGE DOOR.
 ELEVATION SHOWS 2 SMALL GARAGE DOORS. CLARIFY/REVISE AS
 REQUIRED TO MATCH.
  
 12- SHEET A-3.1:A) PORCH SECTION AND TYPICAL WALL
 SECTION CALL FOR "ASPHALT TILE ROOF". CLARIFY WHAT IS
 IT?. REVISE AS REQUIRED.
  
 B) SPECIFY FASTENERS FOR 2X4 FRAMED DOWN CEILING AT
 ENTRY PORCH. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 13- SHEET A-4.1:
 A) DETAIL #1 IS FOR WINDOW AND DOOR BUCK DETAIL.
 CLARIFY TITLE SAYS WINDOW, WHILE DETAIL SAYS DOOR
 FRAME.
 B) THERE ARE TWO DIFFERENT SPECS FOR BUCK FASTENING.
 SEE DETAIL 1 AND WINDOW/DOOR BUCK NOTES ON SHEET S-2
 AND REVISE AS REQUIRED.
 C) HURRICANE PANEL DETAIL: EDGE DISTANCE IS
 INCORRECT. STUCCO THICKNESS CAN'T BE CONSIDERED FOR
 EDGE DISTANCE. REVISE AS REQUIRED. SEE ACTUAL STORM
 PANELS PRODUCT APPROVAL.
 ***NOTE: THIS DETAIL IS NOT REQUIRED. IT'S EASIER AND
 WILL AVOID DISCREPANCIES IF ONLY THE PRODUCT APPROVAL
 FOR STORM SHUTTERS IS PROVIDEDANDAPPROVED BY THE
 DESIGNER OF RECORD.
 D) SECTION AT REAR PORCH: SPECIFY LEDGERS FOR ROOF
 SHEATHING SUPPORT AT MASONRY WALL. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
 ALSO,SPECIFY FIREBLOCKING. SEC. R602.8 2004 FLORIDA
 RESIDENTIAL CODE.
  
 14- SHEET S-2:DETAIL 1/S-2 CALLS FOR (3)2X4 STUDS,
 WHILE 2ND FLOOR FRAMING PLAN CALLS FOR (4)2X4 STUDS.
 CLARIFY/REVISE AS REQUIRED TO MATCH.
  
  
 15- SHEET S-3:
 A) REVISE PLYWOOD SHEATHING NAILING SPECIFICATIONS
 FOR ROOF SHEATHING. SEE SEC. R803.2.3.1 OF 2004 FLORIDA
 RESIDENTIAL CODE.
 B) SPECIFICATION GIVENON PLYWOOD SHEATHING NAILING
 SCHEDULE AND OVERHANG DETAIL DON'T MATCH. REVISE AS
 REQUIRED.
 C) CONNECTOR SCHEDULE: REVISE UPLIFT AND FASTENERS
 SPECIFIED FOR SIMPSON HETAL 16 AND SP4. SEE CURRENT
 CATALOG AND UPDATE AS REQUIRED. OTHERWISE, PROVIDE
 COMPLETE ENGINEERING ANALYSIS FOR VALUES AND NUMBERS
 THAT ARE DIFFERENT FROM THOSE TESTED AND PUBLISHED BY
 MANUFACTURER. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
 D) MAXIMUM DESIGN PRESSURES SHOWN ARE LOW COMPARED
 TO TABLE R301.2((2) OF 2004 FLORIDA RESIDENTIALCODE
 OR TABLES IN ASCE 7-02.PROVIDE ACTUAL CALCULATIONS
 SHOWING HOW THE MAXIMUM POSITIVE AND NEGATIVE LOADS ARE
 DETERMINED. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 16- SOIL TEST REPORT TO HAVE ENGINEERING FIRM
 CERTIFICATE OF AUTHORIZATION NUMBER IN ALL SHEETS AS
 REQUIRED BY SEC. 61G15-23.002 FLORIDA ADMINISTRATIVE
 CODE
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-05-17 Cont ID  
Sent By btrobaug Date 2007-05-24 Time 11:00 Rev Time 0.50
Received By btrobaug Date 2007-05-17 Time 12:33 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-02-12 Cont ID  
Sent By btrobaug Date 2007-02-12 Time 16:34 Rev Time 0.50
Received By btrobaug Date 2007-02-09 Time 06:42 Sent To M
Notes
2007-02-09 07:25:10 
  
  
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} PER 110.9 AND 110.10: OBTAIN THE
 AVAILABLE FAULT CURRENT AT THE UTILITY
 AND CALCULATE THE SAME AT THE EQUIPMENT.
 INDICATE THE AIC RATING FOR THE
 EQUIPMENT IS EQUAL TO OR GREATER THAN
 THE AVAILABLE FAULT. ELECTRICAL NOTE #15 DOES NOT
 SATISFY THIS REQUIREMENT.
  
 2} THE REFERENCE TO THE 2002NEC IS ALSO INCORRECT IN
 THAT NOTE. THE 2005 NEC WAS ADOPTED BY THE FLORIDA
 LEGISLATURE EFFECTIVE 8 DECEMBER 2006. THE APPLICATION
 FOR THIS PROJECT WAS AFTER THAT DATE AND THE PLANS ARE
 SUBJECT TO THAT CODE. PLEASE CHANGE ALL NOTES TO
 REFLECT THIS CHANGE.
  
 3} THE RISER DIAGRAM IS UNCLEAR ON HOW THE SERVICE
 ENTRANCE CONDUCTORS ROUTE TO THE MAIN BRAKER. IF THEY
 ROUTE OVERHEAD THROUGH THE GARAGE, THEN A MAIN
 DISCONNECT IS REQUIRED AT THE METER. SEE 230.70(A)(1).
 IF THEY ARE UNDER THE SLAB THE MAIN IN THE PANEL WOULD
 BE ACCEPTABLE. PLEASE CLARIFY AND ADD THE DISCONNECT IF
 NECESSARY.
  
 4} A RECEPTACLE IS REQUIRED IN THE 2ND FLOOR HALL PER
 21052(E).
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 CONSTRUCTION SERVICES DEPARTMENT
 561) 805-6718

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-05-15 Cont ID  
Sent By adarroug Date 2007-05-15 Time 10:04 Rev Time 0.00
Received By adarroug Date 2007-05-15 Time 10:04 Sent To E
Notes
2007-05-15 10:04:34TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-04-26 Cont ID  
Sent By adarroug Date 2007-04-26 Time 16:46 Rev Time 0.00
Received By adarroug Date 2007-04-26 Time 16:46 Sent To Z
Notes
2007-04-26 16:47:07TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-05 Cont ID  
Sent By adarroug Date 2007-03-05 Time 11:58 Rev Time 0.00
Received By adarroug Date 2007-03-05 Time 11:58 Sent To Z
Notes
2007-03-05 11:58:18TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-23 Cont ID  
Sent By jgomez Date 2007-03-23 Time 12:39 Rev Time 0.00
Received By jgomez Date 2007-02-09 Time 06:42 Sent To  
Notes
2007-02-09 06:43:52 
  
 TO BLD RES SHELF ELEC./WRT

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-05-17 Cont ID  
Sent By tgordon Date 2007-05-17 Time 13:47 Rev Time 0.30
Received By tgordon Date 2007-05-17 Time 13:47 Sent To B
Notes
2007-05-17 14:13:10*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 2) SUBMIT COOLING LOAD CALCULATIONS, SEE
 13-607.1.ABC.1.
  
 3) SHOW ON A/C PLANS EQUIPMENT SCHEDULE CONDENSER UNIT
 MODEL NUMBER AND HEATER KW.
  
 4) SHOW THE SIZE OF THE SUPPLY AIR DUCT ON THE FIRST
 FLOOR TRUNK LINE TO THE MIXING BOX (SEE YELLOW HIGH
 LIGHT ON PLANS).
  
 5) THE WATER CLOSET ROOM AT THE MASTER SUITE WILL NEED
 AN EXHAUST FAN, SEE 2004 FBC/R M1506.3.
  
 6) THE 12" RETURN AIR TRANSFER TO THE MASTER SUITE
 NEEDS TO BE 18", SEE 2004 FBC/R M1602.4.
  
 ALL OF THESE CORRECTIONS HAVE BEEN REQUESTED ON OTHER
 IDENTICAL HOMES FOR ROSEMARY ACQUISITIONS SUBMITTED TO
 THIS OFFICE BY SCOTCORP INC.. IN THE FUTURE PLEASE
 CHECK AND CORRECT PLANS FOR THESE SAME JOBS BEFORE
 SUBMITTING FOR PERMIT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-02-12 Cont ID  
Sent By tgordon Date 2007-02-12 Time 16:27 Rev Time 0.25
Received By tgordon Date 2007-02-12 Time 16:27 Sent To P
Notes
2007-02-12 16:27:36*** DENIED ***
 1) PLEASE SHOW ON ENERGY CALCULATIONS CORRECT ADDRESS
 (WEST PALM BEACH) AND ALSO SHOW JURISDICTION NUMBER.
  
 2)NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW.
 PLEASE SUBMIT MECHANICAL PLANS FOR REVIEW, PER 2004 FBC
 WPB AMEND. 106.3.5.4.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-02-14 Cont ID  
Sent By jleech Date 2007-02-14 Time 15:15 Rev Time 0.00
Received By jleech Date 2007-02-14 Time 15:15 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2007-05-07 Cont ID  
Sent By mflis Date 2007-05-07 Time 13:17 Rev Time 0.00
Received By mflis Date 2007-05-07 Time 13:17 Sent To  
Notes
2007-05-07 13:20:41ZONING REVIEW: DENIED
  
 1) INCORRECT SURVEY PROVIDED: NEED CORRECT SURVEY WITH
 PROPOSED STRUCTURE, DRIVEWAY, AND OTHER PAVING
 INDICATED
 2) SURVEY SHOULD INCLUDED BUILDING SETBACKS
 3) ANY WALL, FENCES, OR GATES SHOULD BE SUBMITTED UNDER
 A SEPARATE PERMIT FOR REVIEW
 4) DRIVEWAY AND SIDWALK CONFIGURATION ON SITE PLAN IS
 UNCLEAR; IS THIS ONE SINGLE DRIVEWAY OR TWO DRIVEWAY
 "TRACKS"?
  
 MATT FLIS - 822-1445

Review Stop Z ZONING
Rev No 1 Status F Date 2007-03-14 Cont ID  
Sent By mflis Date 2007-03-14 Time 16:38 Rev Time 0.00
Received By mflis Date 2007-03-14 Time 16:38 Sent To  
Notes
2007-03-14 16:43:51ZONING REVIEW: FAILED
  
 1) SURVEY AND SITE PLAN DO NOT MATCH; SEE PROPOSED
 DRIVEWAY/SIDEWALK CONFIGURATION ON EACH SHOULD MATCH.
  
 2) PER SEC. 94-482 (A) THE LESS OF 1,000 SQUARE FEET OR
 75 PERCENT OF THE FRONT YARD AREA MUST BE LANDSCAPED;
 PLEASE FIND DIMENSION AND NOTES INDICATING THE
 LANDSCAPED AREA ON THE SITE PLAN.
  
 MATT FLIS - 822-1445


Account Summary | Usage Policy | Privacy Policy