Plan Review Details - Permit 07020045
Plan Review Stops For Permit 07020045
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2007-02-13 Cont ID  
Sent By lursu Date 2007-02-13 Time 11:21 Rev Time 0.00
Received By lursu Date 2007-02-13 Time 11:21 Sent To  
Notes
2007-02-13 11:22:49A NEW ADDRESS 1000 PALM BEACH LAKES BLVD IS ISSUED FOR
 THIS NEW HOUSE TO BE BUILT ON PCN = 74 43 43 16 01 025
 0010.
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2007-02-12 Cont ID  
Sent By lursu Date 2007-02-12 Time 11:07 Rev Time 0.00
Received By lursu Date 2007-02-05 Time 15:39 Sent To  
Notes
2007-02-12 11:08:13PERMIT UNDER REVIEW
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]
2007-02-05 15:40:01COPY OF APPL SENT TO LILLI

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-12-21 Cont ID  
Sent By jgomez Date 2007-12-21 Time 15:48 Rev Time 0.00
Received By jgomez Date 2007-12-21 Time 15:48 Sent To PC
Notes
2007-12-21 15:49:19PLANS SUBMITTED WITH PALM BEACH COUNTY IMPACT FEES
 STAMP. NO FEES DUE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-12-21 Cont ID  
Sent By jgomez Date 2007-12-06 Time 08:54 Rev Time 0.00
Received By jgomez Date 2007-12-06 Time 07:34 Sent To PC
Notes
2007-12-06 09:58:12BUILDING REVIEW APPROVED WITH PROVISO:
 1- PROVIDE COMPLETE AND CORRECT INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT. SEE ATTACHED
 INSTALLATION SCHEDULE SAMPLE.
  
 2- REVISE EGRESS WINDOW NOTE ON SHEET 9.1.SEE SEC.
 R310.1.1 FOR MINIMUM CLEAR OPENING SQUARE FEET. AND
 SEC. R310.1.2 FOR MINIMUM CLEAR HEIGHT.
  
 3- PRECAST LINTELS NOA 03-0605.05 EXPIRED ON 05/21/06.
 NEED TO PROVIDE CURRENT NOA.
  
 4- RE-SUBMITCOMPLETE PRODUCT APPROVAL PACKAGE WITH
 DESIGNER OF RECORD APPROVAL IN WRITING (SEC. 106.3.3
 CITY AMENDMENTS TO FBC 2004).LETTER SUBMITTED
 LISTING ALL PRODUCT APPROVALS NEED TO PROVIDE SPECIFIC
 PRODUCT APPROVAL NUMBER OR NOA NUMBER.OR, PROVIDE
 STANDARD COMPANY'S REVIEW STAMP ON EACH PRODUCT
 APPROVAL.GENERAL STATEMENT EG: PGT INDUSTRIES
 EXTERIOR DOOR IS NOT ACCEPTABLE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-05-29 Cont ID  
Sent By jgomez Date 2007-05-29 Time 16:32 Rev Time 0.00
Received By jgomez Date 2007-05-29 Time 16:32 Sent To PC
Notes
2007-05-29 16:48:12BUILDING REVIEW SECOND CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT.SEC. 713.13
 FLORIDA STATUTE.
  
 2- PAY IMPACT FEES TO PALM BEACH COUNTY. BRING BACK
 STAMPED PLANS AND COPY OF PAID RECEIPT.
  
 3- ENERGY CALCULATIONS:
 A) REVISE OVERHANG HEIGHT AND OVERHANG LENGTH. IT
 CAN'T BE ZERO. SEE PLANS AND REVISE AS REQUIRED.
  
 B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM.
  
 4- IF TAKEN CEILING FANS CREDIT, THENPLANS NEED TO
 SHOW CEILING FAN SIZE TO COMPLY WITH TABLE 13-607.1.A.1
 OF FBC 2004.
  
 5- PROVIDE COMPLETE INFORMATION FOR STORM SHUTTERS.
 PROVIDE PRODUCT APPROVAL AND COMPLETE INSTALLATION
 SCHEDULE. SEE ATTACHED SAMPLE. ALSO, CIRCLE ON
 ENGINEERED DRAWINGS SPECIFIC MOUNTING CONDITIONS AND
 SPECIFIC ANCHOR TYPE AND SPACING TO BE USED ACCORDING
 TO THE DESIGN PRESSURES, EDGE DISTANCE,MAXIMUM PANEL
 SPAN,CONNECTION TYPE AND STRUCTURE TO BE ATTACHED TO
 (CONCRETE BLOCK OR CONCRETE).
  
 *** NOTE; DESIGNER OF RECORD TO REVIEW AND APPROVE IN
 WRITING PRODUCT APPROVAL PRIOR TO SUBMITTAL. SEC.
 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 6- OWES $646.64 FOR UPDATED VALUATION AND RADON FEES.
  
 7- SHEET 7.1: REVISE WALL SECTION 2/7.1. HOW CAN ANCHOR
 BOLT FOR (2)2X8 LEDGER BE EMBEDED 6" IF ANCHOR
 SPECIFIED IS 5/8" X 3 1/2" LONG ?. REVISE AS REQUIRED.
  
 8- SHEET 9.1: CLARIFY HOW EGRESS WINDOWS HAVE DIFFERENT
 CLEAR AREA IF THEY ARE THE SAME SIZE?. SEE WINDOWS D,
 G,M AND Q AND REVISE AS REQUIRED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-21 Cont ID  
Sent By jgomez Date 2007-03-21 Time 18:53 Rev Time 0.00
Received By jgomez Date 2007-03-21 Time 07:48 Sent To  
Notes
2007-03-21 18:54:48BUILDING REVIEWCHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC 713.13
 FLORIDA STATUTE.
  
 2- BRING PLANS TO PALM BEACH COUNTY FOR IMPACT FEES.
 BRING BACK STAMPED PLANS AND COPY OF PAID RECEIPT.
 ***NOTE: MAKE SURE CORRECT BUILDING AREA IS SHOWN ON
 PLANS.
  
 3- SHEET A-1.0: DRIVEWAY APPROACH IS NOT SHOWN
 CORRECTLY. ALSO, CONTACT ENGINEERING DEPARTMENT AT
 (561) 494-1040 FOR DRIVEWAY AND APPROACH STANDARDS.
  
 4- ENERGY CALCULATIONS:
 A) REVISE OVERHANG LENGTH AND HEIGHT. SEE PLANS.
  
 B) MAKE SURE A/C AREA MATCHES PLANS.
  
 C) COMPLETE ALL INFORMATION ON TOP OF FORM.
  
 D) REVISE RAISED WOOD, ADJACENT AREA. SEE PLANS FOR
 CORRECT INFORMATION.
  
 5- PROVIDE COMPLETE INFORMATION FOR STORM SHUTTERS.
 PROVIDE PRODUCT APPROVAL AND COMPLETE INSTALLATION
 SCHEDULE. SEE ATTACHED SAMPLE OF INSTALLATION
 SCHEDULE.
 *** NOTE: DESIGNER OF RECORD TO REVIEW AND APPROVE IN
 WRITING PRODUCT APPROVAL AS REQUIRED BY SEC. 106.3.3
 CITY AMENDMENTS TO FBC 2004.
  
 6- BUILDING VALUATION AND RADON FEES WILL BE UPDATED
 WHEN CORRECT FLOOR AREAS ARE PROVIDED.
  
 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72
 FOR:
 A) ENTRY DOOR WITH IMPACT GLASS AS SPECIFIED ON
 PLANS.
  
 B) ASPHALT SHINGLES.NOA #04-0305.03 EXPIRED ON
 02/21/07.
  
 C) SINGLE HUNG WINDOWS. NEED LEGIBLE DRAWINGS.
  
 D) COLONIAL SHUTTERS SHOWN ON EXTERIOR ELEVATIONS.
  
 E) WINDOW MULLIONS. NEED CLEAR AND LEGIBLE
 DRAWINGS.
  
 F) LOUVERS IN GABLE END WALLS.
  
 G) REAR AND 2ND FLOOR FRENCH DOORS.
  
 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 9- ARCHITECT TO PROVIDE ALL HIS INFORMATION AND FIRM'S
 REGISTRATION NUMBERAS REQUIRED BY SEC. 61G1-16.004 OF
 FLORIDA ADMINISTRATIVE CODE.
  
 10- A) PROVIDE SURVEY WITH PROPOSED BUILDING LAYOUT AND
 SETBACKS.
  
 B) SURVEY TO HAVE ORIGINAL SIGNATURE AS REQUIRED BY
 CHAPTER 472 FLORIDA STATUTE.
  
 11- SHEET 2.1:SPECIFY TOP AND BOTTOM CONNECTORS FOR
 4" WOOD COLUMNS. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 12- SHEET 3.1:
 A) REVISE PLYWOOD SHEATHING NAILING SCHEDULEAND
 NOTE REGARDING RING SHANK NAILS. SEE SEC. R803.2.3.1 OF
 2004 FLORIDA RESIDENTIAL CODE.
  
 B) REVISE SKETCHSHOWING ROOF ZONES.SEE FIGURE
 R301.2(8) 2004 FLORIDA RESIDENTIAL CODE.
  
 C) PROVIDE DETAIL C/3.1 SHOWING CONNECTION OF GABLE
 END BEAM WITH STEEL CAP. SEC. 106.1.2 CITY AMENDMENT TO
 FBC 2004.
  
 D) CLARIFY WHY USING ONLY ONE LEDGER TO SUPPORT
 FLOOR TRUSSES. TAKE INTO CONSIDERATION HOW MUCH BEARING
 IS REQUIRED AT THE END OF TRUSSES AND AT THE END OF
 GIRDER TRUSSES. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 E) PROVIDE DETAIL SHOWING CONNECTION OF FRONT PORCH
 WOOD BEAM TO CONTINUOUS STEEL COLUMN AT CORNER AREAS.
 SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 F) SPECIFY HOW LONG ARE THE HILTI EXP.ANCHORS
 SPECIFIED TO SUPPORT 2X8 JOISTS AT FRONT PORCH. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 G) SPECIFY CONNECTORS AT THE ENDS OF 2X8 JOISTS AT
 FRONT PORCH. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 H) WIND DESIGN INFORMATION ITEM #5: CLARIFY WHY THE
 INTERNAL PRESSURE COEFFICIENT IS NOT APPLICABLE IF THIS
 BUILDING IS DESIGNED ASCLOSED?. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 I) CLEARLY SPECIFY DESIGN PRESSURES FOR EACH OPENING
 IN THIS BUILDING. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 13- SHEET 4.1:
 A) SPECIFY SAFETY GLASS FOR WINDOW NEXT TO THE BATH
 TUB IN MASTER BATHROOM AS REQUIRED BY SEC. R308.4 OF
 2004 FLORIDA RESIDENTIAL CODE
  
 B) REVISE ALL AREA CALCULATIONS.
  
 14- SHEET 6.1: REVISE CARDINAL ORIENTATION OF EACH
 ELEVATION.SEE SURVEY FOR CORRECT BUILDING
 ORIENTATION.
  
  
 15- SHEET 7.1 WALL SECTION 2/7.1: CLARIFY TYPE OF ROOF
 COVERING. SHINGLES OR TILE. REVISE AS REQUIRED.
  
 16- SHEET 9.1:
 A) PROVIDE COMPLETE STRUCTURAL BUCK DETAIL FOR ALL
 DOORAND WINDOW TYPES.SEE SEC. R 613.6.2 OF 2004
 FLORIDA RESDIENTIAL CODE FOR PROPERINSTALLATION.
 SPECIFY ALL FASTENERS. ALSO, SEE PRODUCT APPROVALS FOR
 REQUIRED BUCK SIZE.
  
 B) WINDOW F IS NOT AN EGRESS WINDOW. REVISE AS
 REQUIRED.
  
 16- SOIL TEST REPORT TO HAVE ENGINEERING FIRM
 CERTIFICATE OF AUTHORIZATION NUMBER IN ALL SHEETS AS
 REQUIRED BY SEC. 61G15-23.002 FLORIDA ADMINISTRATIVE
 CODE
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-05-18 Cont ID  
Sent By btrobaug Date 2007-05-18 Time 14:36 Rev Time 0.50
Received By btrobaug Date 2007-05-18 Time 14:23 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-02-08 Cont ID  
Sent By btrobaug Date 2007-02-08 Time 12:16 Rev Time 0.75
Received By btrobaug Date 2007-02-08 Time 11:52 Sent To M
Notes
2007-02-08 12:16:22 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} PER 110.9 AND 110.10: OBTAIN THE
 AVAILABLE FAULT CURRENT AT THE UTILITY
 AND CALCULATE THE SAME AT THE EQUIPMENT.
 INDICATE THE AIC RATING FOR THE
 EQUIPMENT IS EQUAL TO OR GREATER THAN
 THE AVAILABLE FAULT. ELECTRICAL NOTE #15 DOES NOT
 SATISFY THIS REQUIREMENT.
  
 2} THE REFERENCE TO THE 2002NEC IS ALSO INCORRECT IN
 THAT NOTE. THE 2005 NEC WAS ADOPTED BY THE FLORIDA
 LEGISLATURE EFFECTIVE 8 DECEMBER 2006. THE APPLICATION
 FOR THIS PROJECT WAS AFTER THAT DATE AND THE PLANS ARE
 SUBJECT TO THAT CODE. PLEASE CHANGE ALL NOTES TO
 REFLECT THIS CHANGE.
  
 3} THE RISER DIAGRAM IS UNCLEAR ON HOW THE SERVICE
 ENTRANCE CONDUCTORS ROUTE TO THE MAIN BREAKER. IF THEY
 ROUTE OVERHEAD THROUGH THE RESIDENCE, THEN A MAIN
 DISCONNECT IS REQUIRED AT THE METER. SEE 230.70(A)(1).
 IF THEY ARE UNDER THE BUILDING THE MAIN IN THE PANEL
 WOULD BE ACCEPTABLE. PLEASE CLARIFY AND ADD THE
 DISCONNECT IF NECESSARY.
  
 4} THE NOTE AT THE RISER INDICATING A DETACHED GARAGE
 WOULD MAKE IT NECESSARY TO SHOW THAT FEED ON THE RISER
 AND INDICATE WHERE THE OCP IS LOCATED. IF FED FROM THE
 PANEL ADD TO THE SCHEDULWE.
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 CONSTRUCTION SERVICES DEPARTMENT
 561) 805-6718

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-11-19 Cont ID  
Sent By adarroug Date 2007-11-19 Time 11:31 Rev Time 0.00
Received By adarroug Date 2007-11-19 Time 11:31 Sent To B
Notes
2007-11-19 11:31:23TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-18 Cont ID  
Sent By adarroug Date 2007-05-18 Time 13:26 Rev Time 0.00
Received By adarroug Date 2007-05-18 Time 13:26 Sent To E
Notes
2007-05-18 13:26:36TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-04-26 Cont ID  
Sent By adarroug Date 2007-04-26 Time 16:32 Rev Time 0.00
Received By adarroug Date 2007-04-26 Time 16:32 Sent To Z
Notes
2007-04-26 16:33:03TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-21 Cont ID  
Sent By jgomez Date 2007-03-21 Time 18:54 Rev Time 0.00
Received By jgomez Date 2007-02-05 Time 15:42 Sent To  
Notes
2007-02-05 15:42:26TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-05-18 Cont ID  
Sent By tgordon Date 2007-05-18 Time 15:35 Rev Time 0.30
Received By tgordon Date 2007-05-18 Time 15:35 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-02-12 Cont ID  
Sent By tgordon Date 2007-02-12 Time 15:44 Rev Time 0.45
Received By tgordon Date 2007-02-12 Time 15:44 Sent To P
Notes
2007-02-12 16:00:36*** DENIED ***
 1) PLEASE SHOW ON ENERGY CALCULATIONS CORRECT ADDRESS
 (WEST PALM BEACH) AND ALSO SHOW JURISDICTION NUMBER.
  
 2) SEE FIRST FLOOR MECH. PAGE 8.1, 8" RETURN AIR
 TRANSFER DUCT TO BEDROOM #1 NEEDS TO BE 10", SEE 2004
 FBC/R M1602.4.
  
 3) SEE SECOND FLOOR MECH. PAGE 8.1, 14" RETURN AIR DUCT
 (FLEX) OVER ACCESS PANEL (TO AIR HANDLER). PLEASE
 REMOVE FROM PLANS OR SHOW HOW THE DUCT IS GOING TO GET
 TO THE AIR HANDLER.
  
 4) 9" RETURN AIR TRANSFER DUCT TO MASTER SUITE NEEDS TO
 BE 16", SEE 2004 FBC/R M1602.4.
  
 *** 2004 FBC/R M1602.4. BALANCED RETURN AIR MAY BE
 ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE
 RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS
 SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR
 HAVING AT LEAST AN UNRESTRICTED 1 INCHUNDERCUT TO
 ACHIEVE PROPER RETURN AIR BALANCE.
 (C)HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET
 THESE REQUIREMENTS FOR PROPER BALANCED RETURN AIR
 EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY
 ROOMS, EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-02-14 Cont ID  
Sent By jleech Date 2007-02-14 Time 09:36 Rev Time 0.00
Received By jleech Date 2007-02-14 Time 09:36 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2007-05-07 Cont ID  
Sent By mflis Date 2007-05-07 Time 11:52 Rev Time 0.00
Received By mflis Date 2007-05-07 Time 11:54 Sent To I
Notes
2007-05-07 13:05:44ZONING REVIEW: PASSED WITH PROVISO:
  
 1) PLEASE CONTACT ENGINEERING DEPARTMENT FOR REVIEW OF
 CURB CUT ALONG PALM BEACH LAKES BLVD, AND ANY
 COORDINATION NECESSARY WITH COUNTY.
 2) NO FENCES/WALLS/GATES INDICATED IN PERMIT PLANS.
 PLEASE SUBMIT SEPARATE PERMIT FOR THESE ITEMS.
 3) SURVEYS ARE NOT SEALED. PLEASE PROVIDE SEALED
 VERSIONS.
  
 FORWARDED TO BUILDING
  
 MATT FLIS - 822-1445

Review Stop Z ZONING
Rev No 1 Status F Date 2007-02-06 Cont ID  
Sent By mmclean Date 2007-02-06 Time 14:27 Rev Time 0.00
Received By mmclean Date 2007-02-06 Time 14:21 Sent To E
Notes
2007-02-06 14:53:15DENIED,
 1. PLEASE PROVIDE TWO COPIES OF SURVEY SHOWING THE
 PROPOSED STRUCTURE WITH SETBACKS.
 2. THE SUBMITTED DRAINAGE PLAN CANNOT BE USED AS A
 SURVEY.
 3. PLEASE SHOW THE LOCATION OF THE PROPOSEDPOOL
 EQUIPMENT WITH SETBACKS.
 4. PLEASE PROVIDE ON THE TWO COPIES OF SURVEYS THE
 DIMENSION OF PROPOSED DRIVEWAY (LENGTH & WIDTH). 5. ANY
 FENCE/COLUMNS/GATE/WALL SHALL HAVE A SEPARATE PERMIT
 WITH EASEMENT APPROVAL AND THE REQUIRED HEIGHT ALLOWED
 WITHIN THE 25FT FRONT SETBACK IS A MAXIMUM 4FT ONLY.
 6. SUVEYS SUBMITTED ARE VACANT LOT SURVEYS WITH NO
 PROPOSED STRUCTURE SHOWN.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720