Plan Review Details - Permit 07011242
Plan Review Stops For Permit 07011242 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-03-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-29 |
Time |
18:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-03-29 |
Time |
18:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-03-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-20 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-03-20 |
Time |
16:06 |
Sent To |
|
|
Notes |
2007-03-20 16:09:00 | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FACFLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.) SHUTTER MOUNTING TYPE STATES TAPCON, BUT IT SHOULD | | SPECIFY WHICH CONNECTION TYPE YOU ARE USING (NOT WHICH | | ANCHOR).SOME OF THE SPANS ARE SHORTER THAN THE | | OPENING SIZE; IS THIS AN INSIDE MOUNT?THE MOUNTING | | TYPE ANSWERS THIS QUESTION.ANCHORING VARIES DEPENDING | | ON WHICH MOUNTING TYPE IS USED.AS DISCUSSED, NO RESUB | | FEE, AND HAVE THE QUALIFIER SCHEDULE AN APPOINTMENT IF | | HE NEEDS CLARIFICATION. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-02-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-02-27 |
Time |
07:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-02-27 |
Time |
07:46 |
Sent To |
|
|
Notes |
2007-02-27 07:48:17 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | 1.)ON THE SCHEDULE YOU SPECIFY -42PSF, BUT HAVE USED | | THE -40PSF CHART.YOU MUST USE THE -60PSF CHART. | | | | 2.)ON THE SCHEDULE YOU SPECIFY CONCRETE BLOCK, BUT | | HAVE USED THE POURED CONCRETE CHART.PLEASE ADDRESS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-02-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-02-09 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-02-09 |
Time |
14:28 |
Sent To |
|
|
Notes |
2007-02-09 14:33:20 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBEXISTING BUILDING CODE 2004 | | FBC R RESIDENTIAL 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | FBC2004 | | | | 1.)THE INSTALLATION SCHEDULE GIVES 141.5 AS OPENING | | HEIGHT FOR OPENING 1, SPAN OF 75. INDUSTRY STANDARD AND | | THE FORM IS W X H.IT APPEARS THAT THE OPEINGS ARE | | BACKWARDS? | | | | 2.)DEPENDING ON THE CONNECTION DETAIL, THE SPAN IS | | USUALLY LARGER THAN THE OPENING HEIGHT.YOU HAVE | | INDICATED THE SHUTTER SPAN AS THE SAME AS THE OPENING | | WIDTH.IF THE WIDTH IS ACTUALLY THE HEIGHT, THE SPAN | | STILL APPEAR INCORRECT. | | | | 3.)PLEASE REVISE THE INSTALLATION SCHEDULE AND CHECK | | ALL ANCHORING.ANCHORING WAS NOT REVIEWED AS SPANS | | HAVE NOT BEEN DETERMINED. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-03-27 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-03-27 |
Time |
18:40 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-03-27 |
Time |
18:40 |
Sent To |
B |
|
Notes |
2007-03-27 18:40:24 | TO SAMANTHA HILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-03-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-10 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-10 |
Time |
13:00 |
Sent To |
B |
|
Notes |
2007-03-10 13:01:13 | TO "SHILL' DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-22 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-22 |
Time |
14:50 |
Sent To |
B |
|
Notes |
2007-02-22 14:51:19 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-02-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-02-09 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-01-31 |
Time |
14:19 |
Sent To |
|
|
Notes |
2007-01-31 14:19:29 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy