Plan Review Details - Permit 07011179
Plan Review Stops For Permit 07011179
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2007-02-15 Cont ID  
Sent By mperson Date 2007-02-15 Time 14:21 Rev Time 0.33
Received By mperson Date 2007-02-15 Time 14:21 Sent To PC
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2007-02-07 Cont ID  
Sent By mperson Date 2007-02-07 Time 08:53 Rev Time 0.45
Received By mperson Date 2007-02-07 Time 08:53 Sent To PC
Notes
2007-02-07 09:37:39DENIED
 REFERENCE: FBC-2004 FUEL GAS; CITY OF WEST PALM BEACH
 AMENDMENTS TO FBC-2004 CHAPTER 1; FLORIDA STATUTES;
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR GAS PLAN
 REVIEW TO MEET CODE COMPLIANCE:
  
 1. PERMIT APPLICATION IS INCOMPLETE, PER FBC-2004
 CHAPTER 1, SECTION 105.3 AND FLORIDA STATUTES
 713.135(6) SIGNATURE OF CONTRACTOR REQUIRED. PLEASE
 REFREENCE THE ATTACHED FLORIDA STATUTE INDICATING
 THIS.
  
 2. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 NOTE: THIS INCLUDES THE EXISTING SYSTEM.
  
 3. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 NOTE: THIS INCLUDES THE EXISTING SYSTEM.
  
 4. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2004 FUEL GAS CODE SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU
 402.4(33).
 NOTE: THIS INCLUDES THE EXISTING SYSTEM.
  
 5. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY (EXISTING 2ND STAGE REGULATOR) TO THE MOST
 REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4).
 NOTE: THIS INCLUDES THE EXISTING SYSTEM.
  
 6. FBC-2004 CHAPTER 1,SECTION 106.3.4.2:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME, AND ALSO DATE DRAWING. PLEASE DO
 THIS PRIOR TO RESUBMITTING.
  
 7. PER FBC-2004, CHAPTER 1, SECTION
 108.3, BUILDING PERMIT VALUATION: IF IN
 THE OPINION OF THE BUILDING OFFICIAL,
 THE CLAIMED VALUATION OF THE BUILDING,
 ALTERATION, STRUCTURE, ELECTRICAL, GAS
 MECHANICAL OR PLUMBING SYSTEMS APPEARS
 TO BE UNDERESTIMATED ON THE APPLICATION,
 THE PERMIT SHALL BE DENIED. FOR
 PERMITTING PURPOSES, VALUATION OF
 BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, NORMAL SITE WORK (EXCAVATION AND
 BACKFILL FOR BUILDINGS), ARCHITECTURAL
 AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND
 VALUE. VALUATION REFERENCES MAY INCLUDE
 THE LATEST PUBLISHED DATA OF NATIONAL
 CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT,
 MEANS ECT.) WITH
 REGIONAL ADJUSTMENTS FOR LOCATION AS
 PUBLISHED BY INTERNATIONAL CODE
 CONGRESS.
 NOTE: VALUE INCLUDES THE NEW RANGE ALONG WITH THE GAS
 PIPING. PLEASE SUBMIT COPY OF SIGNED CONTRACT TO
 VERIFY. PLEASE ADJUST AND RESUBMIT.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-02-07 Cont ID  
Sent By mperson Date 2007-02-07 Time 09:37 Rev Time 0.00
Received By mperson Date 2007-01-29 Time 16:49 Sent To  
Notes
2007-01-29 16:50:03TO "G" BOX