Plan Review Stops For Permit 07011091 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2008-01-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2008-01-30 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2008-01-30 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-08-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-08-03 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-08-03 |
Time |
15:00 |
Sent To |
|
|
Notes |
2007-08-03 16:04:19 | 2004 FBC | | REPAIRS | | | | DENIED BY BUILDING | | | | 1)THE INFORMATION ON THE ENERGY CALCULATION CAN NOT | | BE CHANGED BY USING WHITE-OUT OR MAKING HANDWRITTEN | | CHANGES. THE CORRECT INFORMTION IS REQUIRED TO BE INPUT | | INTO THE PROGRAM WHEN TO CALCULATIONS ARE BE PROCESSED. | | THE ATTIC INSULATION R-VALUE LISTED ON THE ENERGY CALC. | | FORMS DOES NOT CORRESPOND TO THE ONE SPECIFIED ON THE | | PLANS. SUBMIT NEW ENERGY CALC. FORMS. MAKE THE | | NECESSARY CORRECTIONS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-03-01 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-03-01 |
Time |
09:45 |
Sent To |
|
|
Notes |
2007-03-01 10:51:35 | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) THE OWNER/AGENT IS REQUIRED TO SIGNE THE ENERGY | | CALC. FORM PER FBC CHAPTER 13. | | | | 3) THE NUMBER OF BEDROOMS ON THE PLANS IS 2 AND THE | | ENERGY CALC. FORM LISTS 1. PLEASE CORRECT. | | | | 4) THE CONDITIONED FLOOR AREA FOR THE STRUCTURE IS | | LISTED AS 1058 SQFT ON THE ENERGY CALC. FORM AND BASED | | ON THE PLANS THE STRUCTURE IS 1243 SQFT. PLEASE | | CORRECT. | | | | 5) SPECIFY THE THICKNESS OF THE DRYWALL FOR THE WALLS | | AND CEILING ON THE WALL SECTION ON SHEET 2. | | | | 6) SPECIFY THE NUMBER, SIZES AND TYPES OF FASTENERS | | THAT WILL BE USED WITH THE CONNECTORS SHOWN IN THE WALL | | SECTION ON SHEET 2. | | | | 7) SUBMIT PRODUCT APPROVALS FOR THE USP AND SIMPSON | | CONNECTORS SPECIFIED ON THE PLANS. | | | | 8)PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. | | | | 9)WPB ADMIN CODE 106.3* PRODUCT | | APPROVALS. THOSE PRODUCT WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-07-20 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-07-20 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-07-20 |
Time |
07:02 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-01-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-01-30 |
Time |
10:54 |
Rev Time |
1.00 |
Received By |
btrobaug |
Date |
2007-01-30 |
Time |
07:32 |
Sent To |
M |
|
Notes |
2007-01-30 10:54:22 | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | 1} PER 110.9 AND 110.10: OBTAIN THE | | AVAILABLE FAULT CURRENT AT THE UTILITY | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | INDICATE THE AIC RATING FOR THE | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | THE AVAILABLE FAULT. | | | | 2} PLEASE INDICATE THE SIZE AND TYPE RACEWAY TO BE USED | | FOR THE SERVICE RISER AND PANEL FEEDER. | | | | 3} PLEASE IDENTIFY THE 4/0 SERVICE CABLE FEEDING THE | | PANEL. (IG: SE). | | | | 4} THE BATH CIRCUIT ,#6, ON THE SCHEDULE MUST BE 20 AMP | | TO COMPLY WITH 210.11(C)(3) AND 310.16. | | | | 5} THE DINING ROOM MUST BE ON A SMALL APPLIANCE CIRCUIT | | , OR ITS OWN 20 AMP CIRCUIT PER 210.52(B). | | | | 6} CIRCUIT #3 FEEDING THE SMOKE ALARMS MUST BE AFCI PER | | 210.12. | | | | 7} BOTH BEDROOMS MUST HAVE RECEPTACLES ADDED TO COMPLY | | WITH THE SPACING REQUIREMENTS OF 210.52(A)(1) AND (2). | | SEE REVIEWED SET OF PLANS. | | | | 8} NOTE THATTHE REQUIRED RECEPTACLE PER 210.63. LIGHT | | PER 210.70(A) (3),MUST BE INSTALLED FOR THE AIR | | HANDLER IN THE ATTIC. | | | | 9} THE WATER HEATER IS SHOWN AS BEING PLUGGED INTO A | | RECEPTACLE. PLEASE SEE 422.16 FOR CORD AND PLUG | | ATTACHED APPLIANCES RESTRICIION. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2009-02-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2009-02-26 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2009-02-26 |
Time |
15:25 |
Sent To |
P |
|
Notes |
2009-02-26 15:25:45 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2008-01-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-01-28 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-01-28 |
Time |
10:19 |
Sent To |
M |
|
Notes |
2008-01-28 10:20:16 | TO "M" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-07-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-17 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-17 |
Time |
16:58 |
Sent To |
E |
|
Notes |
2007-07-17 16:58:45 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-07-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-03-01 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-29 |
Time |
11:11 |
Sent To |
|
|
Notes |
2007-01-29 11:11:42 | TO "E" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2008-01-29 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2008-01-29 |
Time |
09:42 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2008-01-29 |
Time |
09:42 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-08-02 |
Time |
14:33 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-08-02 |
Time |
14:33 |
Sent To |
B |
|
Notes |
2007-08-02 14:40:32 | *** DENIED *** | | 1) PLANS PAGE 2/3 IS SHOWING R-19 INSULATION IN THE | | ATTIC, ENERGY CALCULATIONS LINE 11A STATES R-30. PLEASE | | CORRECT. | | | | 2) PLANS PAGE 2/3 SHOWS NO INSULATION TO BE PUT IN | | EXTERIOR WALLS, ENERGY CAL'S. STATE R-11. PLEASE | | CORRECT. | | | | 3) PLEASE BE ADVISED NO CHANGES MAY BE DONE WITH | | WHITE-OUT, PEN, OR PENCIL. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-01-31 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-01-31 |
Time |
14:01 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-01-31 |
Time |
14:01 |
Sent To |
P |
|
Notes |
2007-01-31 14:15:47 | *** DENIED *** | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | ALSO, PER 2004 FBC 13-600.3.ABC.2. | | | | 2) PLEASE SHOW SIZE OF SUPPLY AIR TRUNK LINE TO BEDROOM | | ON MECHANICAL PLANS. | | | | 3) IF THE AIR FILTER IS NOT AT THE AHU BUT AT THE 24X12 | | RETURN AIR GRILL THEN THE 8X6 RETURN AIR GRILL IN THE | | BEDROOM WILL NEED A FILTER ALSO, PLEASE STATE AIR | | FILTER LOCATION ON MECH. PLANS. | | | | 4) 4X12 RETURN AIR TRANSFER GRILL TO BEDROOM IS TO | | SMALL FOR 200 CFM'S.BALANCED RETURN AIR MAY BE | | ACHIEVED BY. | | (B)TRANSFER GRILLES SHALL USE 50 | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | CFM (OF SUPPLY AIR) FOR SIZING | | THROUGH-THE-WALL TRANSFER GRILLES AND | | USING AN UNRESTRICTED 1-INCH | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | RETURN AIR BALANCE. PER 2004 FBC/R M1602.4 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2009-03-06 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2009-03-06 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2009-03-06 |
Time |
10:55 |
Sent To |
|
|
Notes |
2009-03-06 11:13:40 | REVISION OK |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-08-02 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-08-02 |
Time |
13:31 |
Sent To |
M |
|
Notes |
2007-08-02 13:32:05 | FIXTURE CHANGE OUT ONLY |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-02-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-02-03 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-02-03 |
Time |
09:49 |
Sent To |
B |
|
Notes |
2007-02-03 09:57:48 | DENIED; | | NOT ENOUGH INFORMATION TO DO A PLUMBING PLAN REVIEW. | | ADD NOTES ON PLANS TO SHOW WHAT PLUMBING WORK IS TO BE | | DONE; @ ALL FIXTURES AND VALVES TO BE REPLACED NO | | PIPING TO BE DONE. OR, REPLACE FIXTURE MARKED ON PLAN | | ONLY . REPLACE ANY BROKEN OR CORRODED PIPING AS | | REQUIRED TEST AND INSPECT AS REQUIRED. ETC. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|