2007-02-16 08:36:19 | BUILDING PLAN REVIEW |
| PERMIT: 07011081 |
| ADD:3501 S.DIXIE HWY |
| CONT: SIGN CRAFT |
| TEL: (561)863-3660 |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW 1ST. |
| ACTION: DENIED |
| |
| 1)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2)106.1.1CONSTRUCTION DOCUMENTS SHALL BE OF |
| SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| DETERMINED BY THE BUILDING OFFICIAL. THE CALCULATIONS |
| SUBMITTED FOR THE THE SING STRUCTURE IS NOT LEGIBLE. |
| |
| 3)471.025ALLFINAL DRAWINGS, SPECIFICATIONS, |
| PLANS, REPORTS, OR DOCUMENTS PREPARED OR ISSUED BY THE |
| LICENSEE AND BEING FILED FOR PUBLIC RECORD AND ALL |
| FINAL DOCUMENTS PROVIDED TO THE OWNER OR THE OWNER'S |
| REPRESENTATIVE SHALL BE SIGNED BY THE LICENSEE, DATED, |
| AND SEALED WITH SAID SEAL. SUCH SIGNATURE, DATE, AND |
| SEAL SHALL BE EVIDENCE OF THE AUTHENTICITY OF THAT TO |
| WHICH THEY ARE AFFIXED. |
| |
| 4)THE INFORMATION SUBMITTED FOR THE STRUCTURE OF THE |
| SIGN CONTAINS A PHOTO-COPY SIGNATURE OF THE ENGINEER. A |
| PROFESSIONAL ENGINEER SHALL SIGN HIS NAME AND AFFIX HIS |
| SEAL TO ALL PLANS=S, SPECIFICATIONS, REPORTS, FINAL BID |
| DOCUMENTS PROVIDED TO THE OWNER OR THE OWNER'S |
| REPRESENTATIVE, OR OTHER COCUMENTS PREPARED OR ISSUED |
| BY SAID REGISTRANT, AND BEING FILED FOR PUBLIC RECORD. |
| 61G15-23.002. SUBMIT ORIGINAL INFORMATION WHICH WILL BE |
| KEPT FOR PUBLIC RECORD. |
| |
| 5)2004 FL. BLD CODE 1603.1.4 THE |
| FOLLOWING INFORMATION RELATED TO WIND |
| SHALL BE SHOWN ON THE CONSTRUCTION |
| DRAWINGS, |
| 1)- BASIC WIND SPEED, MPH |
| 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| CATEGORY |
| 3)- WIND EXPOSURE |
| 4)- INTERNAL PRESSURE COEFFICIENT, |
| 5)- COMPONENTS & CLADDING, THE DESIGN |
| WIND PRESSURES IN TERMS OF PSF. |
| |
| 6)THE VALUE IS TO LOW.IF, IN THE OPINION OF THE |
| BUILDING OFFICIAL, THE CLAIMED VALUATION OF BUILDING, |
| ALTERATION, STRUCTURE , ELECTRICAL, GAS, MECHANICAL OR |
| PLUMBING SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE |
| APPLICATION, THE PERMIT SHALL BE DENIED. FOR PERMITTING |
| PURPOSES, VALUATION OFBUILDINGS AND SYSTEMS SHALL BE |
| TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, |
| ELECTRIC, PLUMBING, MECHANICAL, NORMAL SITE WORK |
| ARCHITECTURAL AND DESIGN FEES, MARKETING COST, OVERHEAD |
| AND PROFIT; EXCLUDING LAND. OUR VALUATION REFERENCE IS |
| ICC (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS |
| SERVICES PER 108.3 FBC* |
| |
| MYRON JACOBS |
| BUILDING PLAN REVIEWER |
| 805-6726 |