Plan Review Stops For Permit 07011025 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2007-10-26 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2007-10-26 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2007-10-26 |
Time |
13:17 |
Sent To |
|
|
Notes |
2007-10-26 13:20:25 | APPROVED AT RISK, THAT THE CHANGE OF USE PERMIT WILL | | INCORPORATE THE NEW ADDRESS. | | | | | | LM |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2007-10-12 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2007-10-12 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2007-10-09 |
Time |
10:36 |
Sent To |
|
|
Notes |
2007-10-12 14:45:56 | SINCE THE MAIN ENTRANCE OF THIS STRUCTURE WILL BE | | CHANGED TO FACE S DIXIE HWY ,THEN THE SITE PLANS MUST | | BE APPROVED AND THEN AN ADDRESS CHANGE IS REQUIRED. | | | | LACRAMIOARA URSU | | MIS - GIS SUPPORT SPECIALIST | | CITY OF WEST PALM BEACH | | OFFICE:822-1239 | | FAX: 822-1249 | | E-MAIL:[email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-10-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-10-26 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-10-26 |
Time |
13:35 |
Sent To |
|
|
Notes |
2007-10-26 13:36:23 | PROVISO | | | | 1.CONTACT ADDRESSING | | | | 2.AT RISK PERMIT, SUBJECT TO LEGAL CHANGE OF | | OCCUPANCY, PLANS & PERMIT REQUIRED |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-10-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-10-03 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-10-03 |
Time |
11:41 |
Sent To |
|
|
Notes |
2007-10-03 13:14:30 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.)SEE FBC*110.1 REGARDING CHANGE OF OCCUPANCY, | | FBC11-4.1.6 REGARDING A BUILDING CONVERTED FROM | | RESIDENTIAL TO NONRESIDENTIAL USE.NOTE THAT THIS LIST | | MAY NOT BE COMPLETE AS NO PLANS WERE SUBMITTED. | | | | 2.)THE BUILDING IS TO COMPLY WITH THE REQUIREMENTS OF | | FBC EB CHAPTER 8.PLEASE ADD THIS TO THE CODE | | SUMMARY. | | | | 3.)INCLUDE A CODE SUMMARY; BUILDING TYPE FBC6, | | BUILDING HEIGHT AND AREA FBC5, SPRINKLER INFORMATION, | | OCCUPANCY CLASSIFICATION FBC 3, AREA PER OCCUPANCY, AND | | OCCUPANT LOAD.NOTE THAT "GENERAL COMMERCIAL" IS NOT | | AN OCCUPANCY CLASSIFICATION FBC CHAPTER 3. | | | | 4.)PROVIDE A LIFE SAFETY PLAN FBC10.THE FLOOR PLAN | | IS TO SHOW ALL COMPONENTS INCLUDING DOORS, CORRIDOR | | WIDTHS, EXIT LIGHTS, REQUIRED MEANS OF EGRESS, ETC. | | | | 5.)SEE FBC EB 806.1.PROVIDE DETAILS FOR THE | | ACCESSIBLE BATHROOM, DOOR WIDTHS, DOOR HANDLES, ADDRESS | | ANY CHANGE IN ELEVATION, MANEUVERING SPACE AT DOORS, | | CLEARANCE UNDER SINKS, ETC.AS PLANS WERE NOT | | PROVIDED, A COMPLETE CORRECTION LIST CANNOT BE | | PROVIDED. | | | | 6.)THE ADDRESS IS ON WESTMINSTER.WILL THIS REMAIN | | THE FRONT OF THE BUILDING, THE BUILDING ENTRANCE? | | | | 7.)SEE FBC11-4.1.3(8)(D) REGARDING SIGNAGE FOR THE | | ACCESSIBLE ENTRANCE. | | | | 8.)A GATE IS SHOWN IN THE ACCESSIBLE ROUTE.SHOW HOW | | THIS COMPONENT WILL MEET THE REQUIREMENTS OF FBC11-4.3. | | | | | | 9.)PROVIDE A DETAIL FOR THE STAIR AND HANDRAIL. | | | | 10.)THE SHOW THE ACCESS AISLE ON THE SITE PLAN. | | | | 11.)SHOW SLOPE AT THE "RAMP UP" FROM EXISTING 10FT | | SIDEWALK TO BRICK PARKING COURT, FBC11-4.3. | | | | 12.)PLAN SHOWS "NEW STAIR" IN THE VICINITY OF OWNER | | PARKING; THE ARROW DOES NOT APPEAR TO POINT TO A STAIR. | | PROVIDE A DETAIL FOR THE NEW STAIR AND SHOW ON THE SITE | | PLAN.PROVIDE A LEGEND TO SHOW WHAT THE VARIOUS | | DIFFERENT LINES REPRESENT IN THIS AREA.THE ARROW | | POINTS TO SOMETHING WHICH IS TOO NARROW TO BE STAIRS; | | WHAT IS THIS?THERE IS A LINE MADE UP OF CURVES TO THE | | SOUTHWEST OF THE ARROW (RUNNING PARALLEL TO THE HOUSE, | | ON TOP OF THE ROOFLINE), WHAT IS THIS? | | | | 13.)WHAT IS THE FUNCTION OF THE 10X25 LOADING AREA? | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-09-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-09-02 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-09-02 |
Time |
16:00 |
Sent To |
|
|
Notes |
2007-09-02 16:02:46 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.)DECLARE OCCUPANCY FBC CHAPTER 3.IT IS NOT CLEAR | | WHY THERE IS A RAMP AND ACCESSIBLE PARKING FOR A | | PRIVATE RESIDENCE.IS THIS A CHANGE OF OCCUPANCY? | | | | IF THIS IS NOT A PRIVATE RESIDENCE AND IS SUBJECT TO | | ACCESSIBILITY REQUIREMENTS, ADDRESS THE REMOVAL OF THE | | RAMP. | | | | 2.)SHOW STRIPING FOR THE ACCESSIBLE PARKING SPACE ON | | THE PROPOSED SITE PLAN FBC11-4.1. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2007-09-27 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-09-27 |
Time |
14:36 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-09-27 |
Time |
14:36 |
Sent To |
B |
|
Notes |
2007-10-03 14:06:47 | 10/3/07--CHANGE OF OCCUPANCY PER "SHILL" | | ROUTED TO "COMM" BD |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
F |
Date |
2007-08-17 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-08-17 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-08-17 |
Time |
13:26 |
Sent To |
B |
|
Notes |
2007-08-17 13:33:24 | FAILED FOR FOLLOWING REASONS: | | | | 1. YOU ARE PUTTING AN APPROACH, DRIVEWAY, SIDEWALK & | | CUTTING A CURB IN CITY'S RIGHT OF WAY. THEREFORE, YOU | | NEED CITY'S RIGHT OF WAY APPROVAL FROM WINDEL PALMER | | 494-1040, 1000 45TH STREET, ENG DEPT. | | 2. MUST MEET CITY'S STANDARDS FOR APPROACH, | | SIDEWALK,DRIVEWAY ETC. A SHEET " TYPICAL PAVER | | STONE/CONCRETE DRIVEWAY APPROACH DETAILS" ENCLOSED FOR | | YOUR USE. | | 3.PLEASE PROVIDE POLLUTION PREVENTION PLANS, SILT FENCE | | DETAILS, CLOTHES USED FOR SILT ETC., PLEASE SHOW SILT | | FENCE AROUND THE SITE, CATCH BASINS, ETC. | | | | RASIK CHOKSHI 805-6723 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2007-05-31 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-05-31 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-05-31 |
Time |
11:38 |
Sent To |
|
|
Notes |
2007-05-31 11:46:09 | PLEASE PROVIDE FOLLOWING INFO: | | | | 1. PLEASE SHOW STANDARDS NOTES OF CITY OF WPB ON | | DRAWINGSFOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, | | PARKING, HANDICAP PARKING, PAINTPER CITY CODES ETC.,, | | MUST MEET PER ADA,,ETC., YOU CAN GET A C D FROM 1000 | | 45TH STREET FOR ALL CITY STANDARD NOTES. | | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | 3. PLEASE SHOW FIRST FLOOR ELEVATION, CENTER LINE OF | | ROAD , SIDEWALK ELEVATION MUST MEET 5,10,25,100 YEAR | | FLOOD CRITERIA AND FLOOD ZONE AREA., FL BLDG CODE, | | PLEASE SHOW ON CALCULATION & ON THE DRAWINGS. | | 4. HOW YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES | | AROUND YOUR SITE SO, WE CANSEE THE BEST PIPE TO | | CONNECT WITH THE STORM WATERFROM ALL OTHER STORM | | WATER PIPES. | | 5. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED | | 6. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | YOUR SITE FOR STORM WATER DRAIN. | | | | PLEASE RESPOND EACH ITEM IN DETAIL IN A LETTER & IN | | DRAWINGS AS REVISION,TO EXPEDITE YOUR PERMITTING | | PROCESS | | | | RASIK CHOKSHI805-6723 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2007-02-01 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-02-01 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-02-01 |
Time |
13:29 |
Sent To |
B |
|
Notes |
2007-02-01 13:37:19 | PLEASE PROVIDE FOLLOWING INFO: | | | | 1. PLEASE SHOW STANDARDS NOTES OF CITY OF WPB ON | | DRAWINGSFOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, | | PARKING, HANDICAP PARKING, PAINTPER CITY CODES ETC.,, | | MUST MEET PER ADA,,ETC., | | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | 3. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | SIDEWALK ELEVATION MUST MEET FL BLDG CODE, PLEASE SHOW | | ON THE DRAWINGS. | | 4. PLEASE PROVIDE A COPY OF SFWMD PERMIT, GEOTECH | | REPORT., | | 5.PLEASE SHOW STORM WATER CALCULATIONS, WHAT CRITERIA | | YOU ASSUMEDFOR RUNOFF CAL.,, LIKE 1" OVER ENTIRE SITE | | OR2.5"CRITERIA, ?PERVIOUS AREA, LIKE GREEN, | | LAKES, ETC,IMPERVIOUS AREA CAL., | | 6. WHAT IS THE SITE AREA, YOU ARE DEVELOPING FOR THIS | | PROJECT ONLY ? SO, WE CAN CHECK PERVIOUS, IMPERVIOUS | | CAL. | | 7. HOW YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES | | AROUND YOUR SITE SO, WE CANSEE THE BEST PIPE TO | | CONNECT WITH THE STORM WATERFROM ALL OTHER STORM | | WATER PIPES. PLEASE SHOW DETAIL OF THE CONTROL | | STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING | | ELEVATION, ETC,, CALS FOR EXFILTRATION TRENCH ? | | 8. POLLUTION PREVENTION DETAILS,CLOTHES USED FOR SILT | | ETC., PLANS SHOWING SILT FENCE AROUND THE SITE | | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED | | 10. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | YOUR SITE FOR STORM WATER DRAIN. | | | | PLEASE RESPOND EACH ITEM IN DETAIL IN A LETTER & IN | | DRAWINGS AS REVISION,TO EXPEDITE YOUR PERMITTING | | PROCESS | | | | RASIK CHOKSHI805-6723 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2007-09-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-21 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-21 |
Time |
16:35 |
Sent To |
Z |
|
Notes |
2007-10-03 14:12:17 | 10/3/07-CHANGE OF OCCUPANCY | | PLANS WAITING FOR "COMM" BD | 2007-09-21 16:36:23 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-08-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-15 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-15 |
Time |
09:57 |
Sent To |
Z |
|
Notes |
2007-08-15 09:57:46 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-05-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-31 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-31 |
Time |
13:06 |
Sent To |
B |
|
Notes |
2007-05-31 13:07:10 | TO "MISC" BOX#3 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-05-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-29 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-29 |
Time |
09:11 |
Sent To |
ENG |
|
Notes |
2007-05-29 09:12:25 | TO "ENG" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-05-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-17 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-17 |
Time |
09:54 |
Sent To |
Z |
|
Notes |
2007-05-17 09:54:43 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-01-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-31 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-31 |
Time |
11:45 |
Sent To |
ENG |
|
Notes |
2007-01-31 11:45:59 | TO "ENG" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-01-27 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2007-01-27 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2007-01-23 |
Time |
11:44 |
Sent To |
|
|
Notes |
2007-01-23 11:45:44 | TO "Z" BOX--PLANS ONLY NEED "Z"AND "ENG" PER | | "LMARTINEZ".PLANS FOR THE RESIDENCE HAVE BEEN | | SEPARATED WITH A NOTE STATING "NOT FOR REVIEW". |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2007-09-27 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-09-27 |
Time |
08:25 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-09-27 |
Time |
08:25 |
Sent To |
ENG |
|
Notes |
2007-09-27 08:26:10 | ***APPROVED - RESUB #3*** |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2007-08-16 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-08-16 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-08-16 |
Time |
15:48 |
Sent To |
ENG |
|
Notes |
2007-08-16 15:49:37 | ***FAILED******RESUB #2*** | | | | | | 1)PROVIDE PLANT QUALITY SPECIFICATIONS ON LANDSCAPE | | PLAN.SHALL BE EQUAL OR BETTER THAN FLORIDA DEPARTMENT | | OF AGRICULTURE NUMBER ONE (1) NURSERY GRADE STANDARD. | | | | NOTE:AN IRRIGATION PLAN FOR REQUIRED IRRIGATION | | SYSTEM SHALL BE SUBMITTED AND APPROVED PRIOR TO | | LANDSCAPING INSTALLATION AND ISSUANCE OF A CO. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-05-24 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-05-24 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-05-24 |
Time |
17:07 |
Sent To |
I |
|
Notes |
2007-05-24 17:09:50 | ***FAILED*** | | | | | | 1)STRIPING DETAIL FOR HANDICAP ACCESS SIDEWALK MUST | | MATCH DETAIL PROVIDED (SEE ATTACHED). | | | | 2)PLEASE PROVIDE A LANDSCAPE PLAN FOR PROPOSED AREA. | | MUST BE IN ACCORDANCE WITH ARTICLE XIV OF THE CITY OF | | WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | REGULATIONS. | | | | | | CHRIS HOOPS | | ZONING TECHNICIAN | | 561-805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-01-27 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2007-01-27 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2007-01-27 |
Time |
10:09 |
Sent To |
I |
|
Notes |
2007-01-29 10:15:53 | DENIED, | | 1. THE SUBMITED SITE GRADING & DRAINAGE PLANS CANNOT BE | | USED FOR ZONING REVIEW OF PROPOSED DRIVEWAY. | | 2. PLEASE SUBMIT TWO COPIES OF CURRENT SURVEYS SHOWING | | THE PROPOSED DRIVEWAY WITH DIMENSION (WIDTH & LENGTH). | | 3. PLEASE INDICATE IF THE PROPOSED PAVERS WILL BE | | SEALED. | | 4. DOUBLE FRONTAGE LOT, MUST MAINTAIN 1000SQ FT OR 75% | | OF LANDSCAPE, WHICHEVER IS LESS WITHIN THE | | FIRST 25FT FRONT SETBACK. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|