Plan Review Details - Permit 07011015
Plan Review Stops For Permit 07011015
Review Stop G GAS REVIEW
Rev No 4 Status P Date 2007-05-02 Cont ID  
Sent By mperson Date 2007-05-02 Time 15:00 Rev Time 0.45
Received By mperson Date 2007-05-02 Time 15:00 Sent To  
Notes
2007-05-02 15:01:44REVISION: ADDING TWO FIREPLACES TO GAS SYSTEM.
  
  
 IF DRYER ROOM IS A CONFINED SPACE, OPEN-
 INGS REQUIRED PER SECTION 304.5 OR
 SECTION 304.6 SHALL BE INSTALLED.
 MINIMUM 1,100 CUBIC FEET REQUIRED.
  
 IF WATER HEATER ROOM IS A CONFINED
 SPACE, OPENINGS REQUIRED PER SECTION
 304.5 OR SECTION 304.6 SHALL BE
 INSTALLED.
 MINIMUM 3,850 CUBIC FEET REQUIRED.
  

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2007-03-19 Cont ID  
Sent By mperson Date 2007-03-19 Time 13:59 Rev Time 0.45
Received By mperson Date 2007-03-19 Time 13:59 Sent To PC
Notes
2007-03-19 14:38:44REVISION DENIED
 REFERENCE: FBC-2004 FUEL GAS; THE CITY OF WEST PALM
 BEACH GAS PERMIT/REVISION REQUIREMENTS;
  
 THE FOLLOWING CORRECTIONS/INFORMATION IS REQUIRED FOR
 THE GAS REVISION TO MEET CODE COMPLIANCE:
  
 1. THE SUBMITTED ISOMETRIC REVISION DOES NOT INDICATE
 ALL CORRESPONDING LENGTHS PER FBC-2004 FUEL GAS.
  
 A} CORRESPONDING LENGTH TO UNDERGROUND PE PIPE FOR
 POOL HEATER MISSING.
  
 B} CORRESPONDING LENGTH TO NEW PIPING FOR FIREPLACE
 MISSING.
  
 C} CORRESPONDING LENGTH TO COOKTOP MISSING.
  
 2. ON THE SUBMITTED REVISION THE GAS TYPE IS MISSING.
 ON THE PERMITTED PLAN THE GAS TYPE WAS INDICATED AS
 NATURAL GAS. PLEASE CLARIFY AND ON THE REVISION
 RESUBMITTAL.
  
 3. ON THE SUBMITTED REVISION THE MP REGULATOR
 INFORMATION IS MISSING. ON THE PERMITTED PLAN THE
 REGULATOR FOR THE POOL HEATER IS A MAXITROL 325-7 AND
 THE MP REGULATOR FOR THE HOUSE IS A MAXITROL 325-5A.
 PLEASE CLARIFY ON THE REVISION RESUBMITTAL.
  
 4. PER FBC-2004 FUEL GAS, SECTION 409.4 MP REGULATOR
 VALVES: A LISTED SHUTOFF VALVE SHALL BE INSTALLED
 IMMEDIATELY AHEAD OF EACH MP REGULATOR. PLEASE INDICATE
 THESE VALVES ON THE REVISION RESUBMITTAL.
  
 5. PER FBC-2004 FUEL GAS TABLE 402.4(2) THE 1" BLK.
 STEEL PIPE FROM THE MP REGULATOR TO THE HOUSE NEEDS TO
 BE INCREASED IN SIZE TO 1-1/4" DUE TO THE INCREASED BTU
 LOAD OF THE ADDED FIREPLACE. PLEASE CORRECT AND
 RESUBMIT.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
 NOTE: PLEASE REFERENCE THE ATTACHED PERMITTED COPY OF
 THE APPROVED PLANS AND THE FBC-2004 FUEL GAS TABLE
 402.4(2) FOR THE REVISION RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2007-02-12 Cont ID  
Sent By mperson Date 2007-02-12 Time 08:47 Rev Time 0.33
Received By mperson Date 2007-02-12 Time 08:47 Sent To PC
Notes
2007-02-12 09:34:19 
 IF DRYER ROOM IS A CONFINED SPACE, OPEN-
 INGS REQUIRED PER SECTION 304.5 OR
 SECTION 304.6 SHALL BE INSTALLED.
 MINIMUM 1,100 CUBIC FEET REQUIRED.
  
 IF WATER HEATER ROOM IS A CONFINED
 SPACE, OPENINGS REQUIRED PER SECTION
 304.5 OR SECTION 304.6 SHALL BE
 INSTALLED.
 MINIMUM 3,850 CUBIC FEET REQUIRED.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2007-01-26 Cont ID  
Sent By mperson Date 2007-01-26 Time 10:56 Rev Time 0.45
Received By mperson Date 2007-01-26 Time 10:56 Sent To PC
Notes
2007-01-26 10:59:34DENIED
 REFERENCE: FBC-2004 FUEL GAS, CITY OF WEST PALM BEACH
 GAS PERMIT APPLICATION REQUIREMENTS AND FBC-2004
 CHAPTER 1 CITY OF WEST PALM BEACH AMENDMENTS.
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR GAS PLAN
 REVIEW TO MEET CODE COMPLIANCE:
  
 1. PER FBC-2004, CHAPTER 1, SECTION
 108.3, BUILDING PERMIT VALUATION: IF IN
 THE OPINION OF THE BUILDING OFFICIAL,
 THE CLAIMED VALUATION OF THE BUILDING,
 ALTERATION, STRUCTURE, ELECTRICAL, GAS
 MECHANICAL OR PLUMBING SYSTEMS APPEARS
 TO BE UNDERESTIMATED ON THE APPLICATION,
 THE PERMIT SHALL BE DENIED. FOR
 PERMITTING PURPOSES, VALUATION OF
 BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, NORMAL SITE WORK (EXCAVATION AND
 BACKFILL FOR BUILDINGS), ARCHITECTURAL
 AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND
 VALUE. VALUATION REFERENCES MAY INCLUDE
 THE LATEST PUBLISHED DATA OF NATIONAL
 CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT,
 MEANS ECT.) WITH
 REGIONAL ADJUSTMENTS FOR LOCATION AS
 PUBLISHED BY INTERNATIONAL CODE
 CONGRESS.
  
 2. FBC-2004 CHAPTER 1,SECTION 106.3.4.2:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME, AND ALSO DATE DRAWING. PLEASE DO
 THIS PRIOR TO RESUBMITTING.
  
 3. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 NOTE: NOT ALL CORESPONDING LENGTHS ARE INDICATED ON THE
 DRAWINGS. PLEASE CORRECT AND RESUBMIT.
  
 4. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 NOTE: NOT ALL MATERIAL TYPES WERE INDICATED ON THE
 DRAWINGS AND MOST OF THE CSST PIPING IS SIZED WRONG.
 PLEASE REFERENCE THE ATTACHED FBC-2004 FUEL GAS SIZING
 TABLES TO THE COMMENTS AND PLEASE CORRECT AND
 RESUBMIT.
  
 5. PLEASE CORRELATE THE SUBMITTED ISOMETRIC GAS RISER
 WITH THE PERMIT APPLICATION AND INDICATE NATURAL GAS ON
 DRAWING.
  
 6. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4).
  
 7. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2004 FUEL
 GAS CODE SECTION 304.
  
 8. SUBMIT MANUFACTURE SHEETS FOR GAS
 EQUIPMENT (MP REGULATORS) TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2
  
 **********IMPORTANT INFORMATION
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-04-24 Cont ID  
Sent By adarroug Date 2007-04-24 Time 14:26 Rev Time 0.00
Received By adarroug Date 2007-04-24 Time 14:25 Sent To P
Notes
2007-04-24 14:27:05TO "G" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-03-07 Cont ID  
Sent By adarroug Date 2007-03-07 Time 15:18 Rev Time 0.00
Received By adarroug Date 2007-03-07 Time 15:18 Sent To G
Notes
2007-03-07 15:18:39TO "G" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-02-01 Cont ID  
Sent By adarroug Date 2007-02-01 Time 15:21 Rev Time 0.00
Received By adarroug Date 2007-02-01 Time 15:21 Sent To G
Notes
2007-02-01 15:21:35TO "G" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-01-23 Cont ID  
Sent By adarroug Date 2007-01-23 Time 15:21 Rev Time 0.00
Received By adarroug Date 2007-01-23 Time 13:19 Sent To G
Notes
2007-01-23 13:19:48TO "G" BOX