Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-03-26 Cont ID  
Sent By spalmer Date 2007-03-26 Time 18:03 Rev Time 0.00
Received By spalmer Date 2007-03-26 Time 18:03 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-03 Cont ID  
Sent By adarroug Date 2007-03-03 Time 15:46 Rev Time 0.00
Received By adarroug Date 2007-03-03 Time 15:46 Sent To Z
Notes
2007-03-03 15:47:56TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-01-30 Cont ID  
Sent By mmclean Date 2007-01-30 Time 10:40 Rev Time 0.00
Received By mmclean Date 2007-01-20 Time 13:48 Sent To  
Notes
2007-01-20 13:49:13TO "Z" BOX

Review Stop Z ZONING
Rev No 3 Status P Date 2007-03-29 Cont ID  
Sent By jroach Date 2007-03-29 Time 14:39 Rev Time 0.00
Received By jroach Date 2007-03-29 Time 14:39 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2007-03-16 Cont ID  
Sent By jroach Date 2007-03-16 Time 13:54 Rev Time 0.00
Received By jroach Date 2007-03-16 Time 13:54 Sent To  
Notes
2007-03-16 14:00:20***FAILED***
  
 1) PER SECTION 94-302(C)(2) OF THE CITY'S ZONING AND
 LAND DEVELOPMENT REGULATIONS, BARBED WIRE IS PERMITTED;
 HOWEVER, THE STRANDS SHALL MOUNTED VERTICALLY OR AT AN
 ANGLE PROJECTING INTERIOR TO THE PROPERTY AND MUST NOT
 ENCROACH BEYOND THE PROPERTY LINE.PLEASE INDICATE ON
 THE PLAN HOW THIS WILL BE ADDRESSED.
  
 2) PER SECTION 94-305(E), "AT ANY ROAD INTERSECTIONS,
 VISIBILITY SHALL NOT BE OBSCURED BY THE CONSTRUCTION,
 PLACEMENT, OR MAINTENANCE OF A STRUCTURE WALL, SIGN,
 FENCE, BERM, PLANT MATERIAL, SHRUBS, OR ANY SIMILAR
 ITEM BETWEEN 18 INCHES OR EIGHT FEET IN HEIGHT WITHIN A
 TRIANGLE BEGINNING AT THE POINT WHERE PROPERTY LINES
 MEET AT THE CORNER, THEN 20 FEET ALONG THE FRONT
 PROPERTY LINE, THENCE DIAGONALLY TO A POINT ALONG THE
 SIDE PROPERTY LINE 20 FEET FROM THE POINT OF BEGINNING,
 AND THENCE TO THE POINT OF BEGINNING. IN THE EVENT THE
 CORNER OF AN INTERSECTION IS ROUNDED, THE MEASUREMENT
 SHALL BEGIN AT THE POINT THE PROPERTY LINES WOULD MEET
 WITHOUT ROUNDING."
  
 3) FENCES SHALL NOT ENCROACH INTO DRAINAGE EASEMENTS.
 THE FENCE SHALL NOT CROSS THE DRAINAGE EASEMENT ALONG
 WITT STREET.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-01-30 Cont ID  
Sent By mmclean Date 2007-01-30 Time 10:34 Rev Time 0.00
Received By mmclean Date 2007-01-30 Time 10:34 Sent To  
Notes
2007-01-30 10:40:28DENIED,
 1. THE SUBMITTED SITEPLAN IS NOT LEDGERABLE FOR
 REVIEW.
 2. SITEPLAN DOES NOT SHOW CLEARLY THE BOUNDARY OF THE
 PROPERTY TO IDENTIFY THE LOCATION OF THE PROPOSED FENCE
 AND MARK CLEARLY THE 20FT VISIBILITY TRIANGLE ON BOTH N
 FLORIDA MANGO AND WORTHINGTON RD, WORTHINGTON RD AND
 WITT ST.
  
 NOTE: AT ANY ROAD INTERSECTION, VISIBILITY SHALL NOT BE
 OBSCURED BY THE CONSTRUCTION, PLACEMENT, OR
 MAINTENANCE
 OF A STRUCTURE WALL, SIGN, FENCE, BERM PLANT MATERIAL,
 SHRUBS, OR ANY SIMILAR ITEM BETWEEN 18 INCHES OR EIGHT
 POINT
 WHERE PROPERTY LINES MEET AT THE CORNER, THEN 20FT
 ALONG THE FRONT PROPERTY LINE 20FT FROM THE POINT OF
 BEGINING, AND
 THENCE TO THE POINT OF BEGINING.IN THE EVENT THE
 CORNER OF AN INTERSECTION IS ROUNDED, THE MEASUREMENT
 SHALL BEGIN AT
 THE POINT THE PROPERTY LINES WOULD MEET WITHOUT
 ROUNDING. (SEE FIGURE X-1).
  
 3. PLEASE SUBMIT TWO COPIES OF CURRENT SITEPLANS OR
 SURVEYS THAT SHOWS THE LOCATION OF THE PROPOSED FENCE,
 MEETING THE 20FT VISIBILITY TRIANGLE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720