Plan Review Details - Permit 07010851
Plan Review Stops For Permit 07010851
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-03-01 Cont ID  
Sent By shill Date 2007-03-01 Time 16:09 Rev Time 0.00
Received By shill Date 2007-03-01 Time 16:09 Sent To  
Notes
2007-03-01 16:10:25****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)HORIZONTAL SPANS DO NOT CORRELATE WITH OPENINGS.
  
 2.)HOW HAVE YOU DETERMINED DESIGN PRESSURE OF -31?

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-02-02 Cont ID  
Sent By shill Date 2007-02-02 Time 09:23 Rev Time 0.00
Received By shill Date 2007-02-02 Time 09:22 Sent To  
Notes
2007-02-02 09:24:22****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBEXISTING BUILDING CODE 2004
 FBC R RESIDENTIAL 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
 1.)ANCHOR SCHEDULE SPECIFIES ANCHORING FOR CONCRETE.
 YOU HAVE CIRCLED HOLLOW BLOCK ANCHORING, 12 INCH
 SPACING NOT COMPLIANT.HOW HAVE YOU DETERMINED THAT
 ALL OPENINGS HAVE CONCRETE TOP AND BOTTOM AND NOT
 FILLED CELLS OR HOLLOW BLOCK?

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-02-28 Cont ID  
Sent By adarroug Date 2007-02-28 Time 15:24 Rev Time 0.00
Received By adarroug Date 2007-02-28 Time 15:24 Sent To B
Notes
2007-02-28 15:24:32TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-02-02 Cont ID  
Sent By shill Date 2007-02-02 Time 09:24 Rev Time 0.00
Received By shill Date 2007-01-18 Time 14:27 Sent To  
Notes
2007-01-18 14:27:50TO "MISC" BOX#1