Plan Review Stops For Permit 07010577 |
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2007-03-08 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-03-08 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-03-08 |
Time |
13:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
F |
Date |
2007-03-02 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-03-02 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-03-02 |
Time |
08:45 |
Sent To |
|
|
Notes |
2007-03-02 08:49:56 | JUST FOUND OUT THAT WE HAVE ONLY ONE SET ORIGINAL | | SEALED & SIGNED. SECOND SET IS JUST A COPY OF SEALED & | | SIGNED BY PE WHICH IS NOT ACCEPTABLE. | | NEED ORIGINAL SEAL & SIGN SET FOR PERMIT. | | RASIK CHOKSHI 805-6723 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2007-03-02 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-03-02 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-03-02 |
Time |
08:27 |
Sent To |
|
|
Notes |
2007-03-02 08:33:19 | THIS IS A SITE PREPARATION PERMIT OF MAIN PERMIT # | | 06031357.ALL COMMENTS MADE IN REV 1OF THIS PERMIT | | WERE TAKEN CARE IN PERMIT # 06031357. | | | | RASIK CHOKSHI805-6723 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2007-02-01 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-02-01 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-02-01 |
Time |
09:02 |
Sent To |
|
|
Notes |
2007-02-01 09:11:58 | PLEASE PROVIDE FOLLOWING INFO: | | | | 1.PLEASE MAKE SURE ALL STANDARDS NOTES ON DRAWINGS MUST | | MEET CITY OF WPB, & ADA REQUIREMENTS FOR SIDEWALK WIDTH | | , ITS SLOPE, DRIVEWAY, PARKING, HANDICAP PARKING, PAINT | | PER CITY CODES ETC.,, | | 2. PLEASE MAKE SURE DUMPSTER & ITS ENCLOSURE LOCATION | | ON DWG, MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | 3. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | SIDEWALK ELEVATION MUST MEET FL BLDG CODE, PLEASE SHOW | | ON THE DRAWINGS. | | 4. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, GEO TECH | | REPORT. | | 5.PLEASE SHOW STORM WATER CALCULATIONS, WHAT CRITERIA | | YOU ASSUMEDFOR RUNOFF CAL.,, LIKE 1" OVER ENTIRE SITE | | OR2.5"CRITERIA, ?PERVIOUS AREA, LIKE GREEN, | | LAKES, ETC,IMPERVIOUS AREA CAL., | | 6. WHAT IS THE SITE AREA, YOU ARE DEVELOPING FOR THIS | | PROJECT ONLY ? SO, WE CAN CHECK PERVIOUS, IMPERVIOUS | | CAL. | | 7. HOW YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES | | AROUND YOUR SITE SO, WE CANSEE THE BEST PIPE TO | | CONNECT WITH THE STORM WATERFROM ALL OTHER STORM | | WATER PIPES. PLEASE SHOW DETAIL OF THE CONTROL | | STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING | | ELEVATION, ETC DID YOU USE EXFILTRATION TRENCH ? | | 8.ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | YOUR SITE FOR STORM WATER DRAIN. | | | | PLEASE RESPOND EACH ITEM IN DETAIL IN A LETTER & ON | | DRAWINGS AS REVISIONS TO EXPEDITE YOUR PERMITTING | | PROCESS | | | | RASIK CHOKSHI805-6723 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2007-02-12 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-02-12 |
Time |
17:05 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-02-12 |
Time |
17:05 |
Sent To |
|
|
Notes |
2007-02-12 17:15:22 | *****APPROVED*****W/REMINDERS | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 2.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL NOT | | HINDER OR INTERFERE WITH EMERGENCY ACCESS RESPONSE TO | | THE PROPERTY OR THE VICINTY THEREOF (INCLUDING FIRE | | LANES). |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-02-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-28 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-28 |
Time |
15:36 |
Sent To |
ENG |
|
Notes |
2007-02-28 15:36:35 | TO "ENG" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-01-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-29 |
Time |
19:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-29 |
Time |
19:07 |
Sent To |
ENG |
|
Notes |
2007-01-29 19:07:52 | TO "ENG" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-02-12 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-02-12 |
Time |
17:05 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-01-12 |
Time |
09:51 |
Sent To |
|
|
Notes |
2007-01-12 09:53:27 | TO "ENG" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2007-01-25 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2007-01-25 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2007-01-25 |
Time |
15:13 |
Sent To |
|
|
Notes |
2007-01-25 15:20:12 | PLANNING AND ZONING:PASSED WITH PROVISO | | | | 1. ONE (1) OF THE TWO (2) SETS SUBMITTED IS NOT SIGNED | | AND SEALED WITH ORIGINAL EMBOSS. | | WHEN RE-SUBMITTING PROVIDE ALL SETS WITH ORIGINAL | | SIGNED AND SEALED EMBOSS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 |
|
|