Plan Review Stops For Permit 07010034 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-03-03 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-03-03 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-03-03 |
Time |
13:06 |
Sent To |
PC |
|
Notes |
2007-03-03 13:55:21 | BUILDING PROVISO: | | TO BE IN PLACE AT C.O.: | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | WITH A BARRIER COMPLYING WITH | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | ASTM D5034 100 LB TENSILE STRENGTH | | ASTM D3787 150 LB BALL BURST STRENGTH | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | EQUIPPED WITH A COVER DESIGNED TO | | MINIMIZE HEAT LOSS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-02-09 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-02-09 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-02-09 |
Time |
10:51 |
Sent To |
PC |
|
Notes |
2007-02-09 12:13:56 | BUILDING PLAN REVIEW | | PERMIT: | | ADD: | | CONT: | | TEL: (561)###-#### | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1)FBC 424.2.7.2AND R4101.7.2ALL POOL EQUIPMENT | | SHALL BE INSTALLED ON CONCRETE SLAB NO LESS THAN 4" | | THICK. SUBMIT THE CONCRETE DETAIL FOR THE EQUIPMENT. | | | | 2)WPB AMENDMENTS 106.1.3THE BUILDING OFFICIAL MAY | | ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR | | PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE | | COMFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY | | MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE, | | CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORDS | | MANAGEMENT. THE DRAWINGS SHOW A HEATER STUB-OUT. WILL A | | HEATER BE INSTALL OR IS THE STUB-OUT FOR FUTURE USE? | | THE DRAWINGS NEED SHALL CLEARLY SHOW IF THE HEATER WILL | | BE INSTALLED. IF SO, SHOW THE SIZE OF THE HEATER. | | | | SEE NOTES FORM OTHER REVIEWS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-03-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-03-01 |
Time |
07:26 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2007-03-01 |
Time |
07:13 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2007-02-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-02-01 |
Time |
07:18 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-02-01 |
Time |
06:47 |
Sent To |
P |
|
Notes |
2007-02-01 07:17:56 | | | | | DENIED/INCOMPLETE INFORMATION | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | SUBMIT DETAILS FOR THE PANEL | | SHOWN ON THE SCHEMATIC, FEEDER AND CONDUIT SIZE AND | | TYPE, PANEL RATING AND OCP, | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. THERE IS NO POOL | | PANEL ON THE ORIGINAL RESIDENCE PLAN. | | | | WILLIAM R. TROBAUGH | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | 561/805-6718 | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2007-02-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-02-06 |
Time |
09:24 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-02-06 |
Time |
09:24 |
Sent To |
B |
|
Notes |
2007-02-06 09:26:48 | NOTE: THERE IS PIPING BEING PROVIDED FOR A FUTURE | | HEATER, BUT AT THIS TIME NO INDICATION IF HEATER IS GAS | | OR ELECTRIC. | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-02-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-27 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-27 |
Time |
10:08 |
Sent To |
E |
|
Notes |
2007-02-27 10:08:46 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-02-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-21 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-21 |
Time |
11:25 |
Sent To |
Z |
|
Notes |
2007-02-21 11:26:03 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-01-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-31 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-31 |
Time |
11:07 |
Sent To |
E |
|
Notes |
2007-01-31 11:07:45 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-02-09 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-20 |
Time |
14:28 |
Sent To |
|
|
Notes |
2007-01-20 14:32:21 | TO "Z" BOX--FIRST REVIEW, PLANS WERE PULLED FROM | | INCOMING DURING INITIAL REVIEW PROCESS.(SEE FRONT | | SCREEN NOTES) |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2007-03-01 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-03-01 |
Time |
11:38 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2007-03-01 |
Time |
11:38 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-02-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-02-06 |
Time |
08:59 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2007-02-06 |
Time |
08:59 |
Sent To |
G |
|
Notes |
2007-02-06 09:22:52 | DENIED | | REFERENCE: FBC-2004 SECTIONS 424.2 AND R4101 SWIMMING | | POOLS | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1) FBC-2004 SEC. 424.2.6.6.5, OR | | FBCR-2004 SEC. R4101.6.6.5 WHERE | | PROVIDED, THE VACUUM OR PRESSURE CLEANER | | FITTING SHALL BE LOCATED AT LEAST 6" AND | | NOT GREATER THAN 12" BELOW THE MINIMUM | | OPER ATING WATER LEVEL OR AS AN | | ATTACHMENT TO THE SKIMMER. | | NOTE: PLEASE PROVIDE MANUFACTURER SPECIFICATION SHEET | | OR INDICATE THE MAKE AND MODEL NUMBER ON THE | | RESUBMITTED PRINTS. | | | | 2) FBC-2004 SEC. 424.2.7.2, OR | | FBCR-2004 SEC. R4101.7.2 PUMPS AND | | EQUIPMENT SHALL BE MOUNTED ON A | | SUBSTANTIAL BASE IN A MANNER THAT WILL | | ELIMINATE STRAIN ON PIPING.SLAB SHALL | | BE A NOMINAL 4" THICK. | | NOTE: (DETAIL REQUIRED) | | | | 3) FBC-2004 SEC. 424.2.9, OR FBCR-2004 SEC. | | R4101.9 WATER SUPPLY, LOCAL ORD. | | #2853-95, BACKFLOW REQUIRED ON WATER | | SERVICE.(ADD TO NOTES) | | | | 4) FBC-2004 SEC. 424.2.12.1, OR | | FBCR-2004 SEC. R4101.12.1 PRESSURE | | TESTS. PER MANUFACTURE RECOMMENDATIONS, | | NO AIR TEST SHALL BE APPROVED FOR PVC | | PIPE AND FITTINGS. (ADD TO NOTES) | | | | 5) FBC-2004 SEC. 424.2.13.2, OR | | FBCR-2004 SEC.R4101.13.2 JOINTS AND | | CONNECTIONS, FBC PLMG SEC 605.21, PURPLE | | PRIMER REQUIRED ON PVC PIPING.(ADD TO | | NOTES) | | | | 6) SHEET 1 SPECIFICATIONS POOL HEATER TYPE, PLEASE | | INDICATE FUTURE STUB-OUT. SHEET 2 POOL PIPING DIAGRAM, | | PLEASE INDICATE FUTURE HEATER STUB-OUT AND INDICATE | | THAT THE HEATER STUB-OUTS ARE BEING PRESSURE CAPPED. | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-02-25 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-02-25 |
Time |
18:12 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-02-25 |
Time |
18:12 |
Sent To |
I |
|
Notes |
2007-02-25 18:14:04 | ***PROVISO*** | | | | 1) POOL EQUIPMENT SHALL BE A MINIMUM OF ONE (1) FOOT | | FROM THE WEST PROPERTY LINE!!!!! | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2007-01-30 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2007-01-30 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2007-01-30 |
Time |
11:57 |
Sent To |
I |
|
Notes |
2007-01-30 11:59:08 | DENIED, | | 1. THE SUBMITTED SURVEYS DOES NOT SHOW THE LOCATION OF | | PROPOSED POOL EQUIPMENT. | | 2. PLEASE MARK THE LOCATION OF THE PROPOSED POOL | | EQUIPMENT AND PROVIDE THE SETBACKS. | | NOTE: SEC 94-303 MECHANICAL/POOL EQUIPMENT/GENERATOR | | MAY NOT PROJECT MORE THAN FOUR FEET INTO A SETBACK. | | NOTE:SEC 94-304(2)(B) - EVERY SWIMMING POOL SHALL BE | | ENCLOSED BY A FENCE OR SIMILAR STRUCTURE WHICH IS | | INSTALLED TO OBSTRUCT ACCESS BY PERSONS OTHER THAN THE | | OWNERS OR OCCUPANTS OF THE RESIDENCE WITHIIN WHICH A | | SWIMMING POOL IS LOCATED.BARRIERS OR FENCES SHALL BE | | AT LEAST FOUR FEET IN HEIGHT ABOVE GRADE. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|