Plan Review Details - Permit 07010034
Plan Review Stops For Permit 07010034
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-03-03 Cont ID  
Sent By mjacobs Date 2007-03-03 Time 14:17 Rev Time 0.00
Received By mjacobs Date 2007-03-03 Time 13:06 Sent To PC
Notes
2007-03-03 13:55:21BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRENGTH
 ASTM D3787 150 LB BALL BURST STRENGTH
  
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-02-09 Cont ID  
Sent By mjacobs Date 2007-02-09 Time 12:14 Rev Time 0.00
Received By mjacobs Date 2007-02-09 Time 10:51 Sent To PC
Notes
2007-02-09 12:13:56BUILDING PLAN REVIEW
 PERMIT:
 ADD:
 CONT:
 TEL: (561)###-####
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1)FBC 424.2.7.2AND R4101.7.2ALL POOL EQUIPMENT
 SHALL BE INSTALLED ON CONCRETE SLAB NO LESS THAN 4"
 THICK. SUBMIT THE CONCRETE DETAIL FOR THE EQUIPMENT.
  
 2)WPB AMENDMENTS 106.1.3THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR
 PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE
 COMFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY
 MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE,
 CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORDS
 MANAGEMENT. THE DRAWINGS SHOW A HEATER STUB-OUT. WILL A
 HEATER BE INSTALL OR IS THE STUB-OUT FOR FUTURE USE?
 THE DRAWINGS NEED SHALL CLEARLY SHOW IF THE HEATER WILL
 BE INSTALLED. IF SO, SHOW THE SIZE OF THE HEATER.
  
 SEE NOTES FORM OTHER REVIEWS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-03-01 Cont ID  
Sent By btrobaug Date 2007-03-01 Time 07:26 Rev Time 0.33
Received By btrobaug Date 2007-03-01 Time 07:13 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-02-01 Cont ID  
Sent By btrobaug Date 2007-02-01 Time 07:18 Rev Time 0.00
Received By btrobaug Date 2007-02-01 Time 06:47 Sent To P
Notes
2007-02-01 07:17:56 
  
 DENIED/INCOMPLETE INFORMATION
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 SUBMIT DETAILS FOR THE PANEL
 SHOWN ON THE SCHEMATIC, FEEDER AND CONDUIT SIZE AND
 TYPE, PANEL RATING AND OCP,
 PANEL SCHEDULE AND COMPUTED LOAD, ETC. THERE IS NO POOL
 PANEL ON THE ORIGINAL RESIDENCE PLAN.
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2007-02-06 Cont ID  
Sent By mperson Date 2007-02-06 Time 09:24 Rev Time 0.00
Received By mperson Date 2007-02-06 Time 09:24 Sent To B
Notes
2007-02-06 09:26:48NOTE: THERE IS PIPING BEING PROVIDED FOR A FUTURE
 HEATER, BUT AT THIS TIME NO INDICATION IF HEATER IS GAS
 OR ELECTRIC.
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-02-27 Cont ID  
Sent By adarroug Date 2007-02-27 Time 10:08 Rev Time 0.00
Received By adarroug Date 2007-02-27 Time 10:08 Sent To E
Notes
2007-02-27 10:08:46TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-02-21 Cont ID  
Sent By adarroug Date 2007-02-21 Time 11:25 Rev Time 0.00
Received By adarroug Date 2007-02-21 Time 11:25 Sent To Z
Notes
2007-02-21 11:26:03TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-01-31 Cont ID  
Sent By adarroug Date 2007-01-31 Time 11:07 Rev Time 0.00
Received By adarroug Date 2007-01-31 Time 11:07 Sent To E
Notes
2007-01-31 11:07:45TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-02-09 Time   Rev Time 0.00
Received By adarroug Date 2007-01-20 Time 14:28 Sent To  
Notes
2007-01-20 14:32:21TO "Z" BOX--FIRST REVIEW, PLANS WERE PULLED FROM
 INCOMING DURING INITIAL REVIEW PROCESS.(SEE FRONT
 SCREEN NOTES)

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-03-01 Cont ID  
Sent By mperson Date 2007-03-01 Time 11:38 Rev Time 0.33
Received By mperson Date 2007-03-01 Time 11:38 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-02-06 Cont ID  
Sent By mperson Date 2007-02-06 Time 08:59 Rev Time 0.33
Received By mperson Date 2007-02-06 Time 08:59 Sent To G
Notes
2007-02-06 09:22:52DENIED
 REFERENCE: FBC-2004 SECTIONS 424.2 AND R4101 SWIMMING
 POOLS
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING
 PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1) FBC-2004 SEC. 424.2.6.6.5, OR
 FBCR-2004 SEC. R4101.6.6.5 WHERE
 PROVIDED, THE VACUUM OR PRESSURE CLEANER
 FITTING SHALL BE LOCATED AT LEAST 6" AND
 NOT GREATER THAN 12" BELOW THE MINIMUM
 OPER ATING WATER LEVEL OR AS AN
 ATTACHMENT TO THE SKIMMER.
 NOTE: PLEASE PROVIDE MANUFACTURER SPECIFICATION SHEET
 OR INDICATE THE MAKE AND MODEL NUMBER ON THE
 RESUBMITTED PRINTS.
  
 2) FBC-2004 SEC. 424.2.7.2, OR
 FBCR-2004 SEC. R4101.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK.
 NOTE: (DETAIL REQUIRED)
  
 3) FBC-2004 SEC. 424.2.9, OR FBCR-2004 SEC.
 R4101.9 WATER SUPPLY, LOCAL ORD.
 #2853-95, BACKFLOW REQUIRED ON WATER
 SERVICE.(ADD TO NOTES)
  
 4) FBC-2004 SEC. 424.2.12.1, OR
 FBCR-2004 SEC. R4101.12.1 PRESSURE
 TESTS. PER MANUFACTURE RECOMMENDATIONS,
 NO AIR TEST SHALL BE APPROVED FOR PVC
 PIPE AND FITTINGS. (ADD TO NOTES)
  
 5) FBC-2004 SEC. 424.2.13.2, OR
 FBCR-2004 SEC.R4101.13.2 JOINTS AND
 CONNECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING.(ADD TO
 NOTES)
  
 6) SHEET 1 SPECIFICATIONS POOL HEATER TYPE, PLEASE
 INDICATE FUTURE STUB-OUT. SHEET 2 POOL PIPING DIAGRAM,
 PLEASE INDICATE FUTURE HEATER STUB-OUT AND INDICATE
 THAT THE HEATER STUB-OUTS ARE BEING PRESSURE CAPPED.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2007-02-25 Cont ID  
Sent By jroach Date 2007-02-25 Time 18:12 Rev Time 0.00
Received By jroach Date 2007-02-25 Time 18:12 Sent To I
Notes
2007-02-25 18:14:04***PROVISO***
  
 1) POOL EQUIPMENT SHALL BE A MINIMUM OF ONE (1) FOOT
 FROM THE WEST PROPERTY LINE!!!!!
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-01-30 Cont ID  
Sent By mmclean Date 2007-01-30 Time 11:57 Rev Time 0.00
Received By mmclean Date 2007-01-30 Time 11:57 Sent To I
Notes
2007-01-30 11:59:08DENIED,
 1. THE SUBMITTED SURVEYS DOES NOT SHOW THE LOCATION OF
 PROPOSED POOL EQUIPMENT.
 2. PLEASE MARK THE LOCATION OF THE PROPOSED POOL
 EQUIPMENT AND PROVIDE THE SETBACKS.
 NOTE: SEC 94-303 MECHANICAL/POOL EQUIPMENT/GENERATOR
 MAY NOT PROJECT MORE THAN FOUR FEET INTO A SETBACK.
 NOTE:SEC 94-304(2)(B) - EVERY SWIMMING POOL SHALL BE
 ENCLOSED BY A FENCE OR SIMILAR STRUCTURE WHICH IS
 INSTALLED TO OBSTRUCT ACCESS BY PERSONS OTHER THAN THE
 OWNERS OR OCCUPANTS OF THE RESIDENCE WITHIIN WHICH A
 SWIMMING POOL IS LOCATED.BARRIERS OR FENCES SHALL BE
 AT LEAST FOUR FEET IN HEIGHT ABOVE GRADE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720