Plan Review Details - Permit 06120726
Plan Review Stops For Permit 06120726 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-02-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-02-06 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-02-06 |
Time |
13:21 |
Sent To |
|
|
Notes |
2007-02-06 14:02:10 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | FBC2004 | | | | 1.)THE APPLICATION STATES THAT YOU ARE REPLACING | | WINDOWS, BUT THE PLAN STATES THAT THIS IS A SCREEN | | ROOM.WHAT SUPPORTS THE WINDOWS ON EACH SIDE?PROVIDE | | DETAILS.WAS THIS PERMITTED, WERE IMPACT FEES PAID TO | | PALM BEACH COUNTY TO ENCLOSE THE PORCH? | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-01-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-01-30 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-01-30 |
Time |
15:57 |
Sent To |
|
|
Notes |
2007-01-30 15:57:36 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBEXISTING BUILDING CODE 2004 | | FBC R RESIDENTIAL 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | FBC2004 | | | | WINDOW OR DOOR PERMIT APPLICATION, ONLY CHECKED ITEMS | | APPLY | | | | ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | ____2.PROVIDE BUILDING HEIGHT.DESIGN PRESSURES | | FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE DESIGNED | | USING ASCE7, FBC1609.1.1. DOCUMENTS PREPARED BY AN | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED SEALED ORIGINALS FAC61G15-23.002. | | | | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | APPROVAL. | | | | _XX_4.IMPACT PROTECTION REQUIRED,FBC1609.1.4.IF | | LESS THAN 25% OF THE TOTAL GLAZED AREA IS BEING | | REPLACED, PROVIDE CALCULATIONS FBC EB507.3. | | | | ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | ____6.PROVIDE A FLOOR PLAN SHOWING: WINDOW | | LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE | | EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE | | FOR BEDROOMS, FBC R310, FBC EB 505.1. | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-02-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-05 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-05 |
Time |
16:06 |
Sent To |
B |
|
Notes |
2007-02-05 16:06:54 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-01-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-01-30 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-12-28 |
Time |
15:01 |
Sent To |
|
|
Notes |
2006-12-28 15:02:28 | TO "MISC" BOX#1 |
|
|
|