Plan Review Details - Permit 06120629
Plan Review Stops For Permit 06120629
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-10-24 Cont ID  
Sent By rmcdouga Date 2007-10-24 Time 17:24 Rev Time 0.00
Received By rmcdouga Date 2007-10-24 Time 17:24 Sent To  
Notes
2007-10-24 17:25:44SUBMITTED SIGNED AND SEALED RAS 117 CALCULATIONS AS
 REQUESTED IN THE BUILDING PROVISO.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-09-17 Cont ID  
Sent By rmcdouga Date 2007-09-17 Time 10:44 Rev Time 0.00
Received By rmcdouga Date 2007-09-17 Time 10:44 Sent To  
Notes
2007-09-17 11:07:37BUILDING PROVISO
  
 THE PLANS SPECIFY EXPOSURE CATEGORY "C". SUBMIT RAS 117
 CALCULATIONS FOR THE GAF MODIFIED ROOFING SYSTEM WITH
 ENHANCED FASTENING THAT IS CAPABLE OF RESISTING THE
 COMPONENT AND CLADDING PRESSURES FOR ROOFS IN EXPOSURE
 "C" WITH A 140 MPH (3 SECOND GUST) WIND SPEED. THE ONES
 THAT WERE SUBMITTED ARE INCORRECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-09-04 Cont ID  
Sent By rmcdouga Date 2007-09-04 Time 18:14 Rev Time 0.00
Received By rmcdouga Date 2007-09-04 Time 17:46 Sent To  
Notes
2007-09-04 18:14:252004 FBC
 3RD REVIEW
 ADDITION AND REMODEL
  
 DENIED BY BUILDING
  
 1) THE NOC THAT WAS SUBMITTED IS EXPIRED. IT WILL NEED
 TO BE RERECORDED BEFORE THE PERMIT IS ISSUED.
  
 2) SUBMIT A COPY OF THE PAID RECEIPT FOR THE COUNTY
 IMPACT FEES. ATTACH THE SHEETS WITH THE COUNTY IMPACT
 FEE STAMPS FROM THE OLD PLANS TO THE FRONT OF THE NEW
 PLANS OR HAVE THE NEW PLANS STAMPED BY THE COUNTY.
  
 3) THE MAXIMUM DESIGNED PRESSURE SPECIFIED ON PAGE 28
 OF -45 PSF FOR THE THE GAF MODIFIED ROOF SYSTEM NOA IS
 NOT ADEQUATE TO RESIST THE COMPONENT AND CLADDING WIND
 PRESSURES FOR EXPOSURE C . SEE FBC TABLE R301.2(2). THE
 DESIGN PRESSURES ARE LESS THAN REQUIRED FOR A FLAT ROOF
 IN ZONE C ( -107.7 PSF FOR ROOF ZONE 3 AND - 71.6 FOR
 ZONE 2) . SUBMIT RAS 117 CALCULATIONS FOR ENHANCED
 FASTENING AS ALLOWED BY LIMITATION #7 ON PAGE 32 OF THE
 NOA.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-07-09 Cont ID  
Sent By rmcdouga Date 2007-07-09 Time 14:15 Rev Time 0.00
Received By rmcdouga Date 2007-07-09 Time 14:15 Sent To  
Notes
2007-07-09 15:42:29DENIED BY BUILDING
  
 1) THE NOC THAT WAS SUBMITTED IS EXPIRED. IT WILL NEED
 TO BE RERECORDED BEFORE THE PERMIT IS ISSUED.
  
 2) SUBMIT A COPY OF THE PAID RECEIPT FOR THE COUNTY
 IMPACT FEES. ATTACH THE SHEETS WITH THE COUNTY IMPACT
 FEE STAMPS FROM THE OLD PLANS TO THE FRONT OF THE NEW
 PLANS OR HAVE THE NEW PLANS STAMPED BY THE COUNTY.
  
 3) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED
 BY THE PREPARER PER FBC CHAPTER 13.
  
 4) BATHROOM DOOR NUMBER 10 ON THE SCHEDULE DOES NOT
 COMPLY WITH R322.1.1 FOR ACCESSIBILITY, WHICH REQUIRES
 AT LEAST ONE BATHROOM WITH A DOOR THAT HAS A 29" CLEAR
 OPENING.
 THE 29 " CLEAR OPENING IS WITH THE DOOR OPEN 90 DEGREES
 MEASURED BETWEEN THE FACE OF THE DOOR AND THE OPPOSITE
 STOP. SEE R322.2.2 AND FBC 11-4.13.5.
  
 5) THE TRUSS LAYOUT IS REQUIRED TO BE SIGNED, SEALED
 AND DATED BY THE TRUSS ENGINEER, IN ADDITION TO BEING
 REVIEWED AND APPROVED BY THE DESIGNER OF RECORD FOR THE
 STRUCTURE.
 FS 471
  
 6) THE TRUSS DRAWINGS ARE REQUIRED TO BE SIGNED BY THE
 TRUSS ENGINEER, SIGNATURE STAMPS ARE NOT ACCEPTABLE. FS
 471 AND FAC 61G15-23.002.
 NOTE: TRUSS LAYOUT AND DRAWINGS CAN BE SUBMITTED THE
 INSPECTOR IN THE FIELD AT TIME OF TRUSS INSPECTION.
  
 7) SPECIFY WHICH ONE OF THE FASTENING OPTIONS AND
 DESIGN PRESSURES ON PAGE 28 OF THE NOAWILL BE USED TO
 INSTALL THE GAF MODIFIED ROOF SYSTEM. CIRCLE THE
 APPROPRIATE ONE ON THE NOA. THE DESIGN PRESSURES ARE
 LESS THAN REQUIRED FOR A FLAT ROOF IN ZONE C ( -107.7
 PSF FOR ROOF ZONE 3 AND - 71.6 FOR ZONE 2) . SUBMIT RAS
 117 CALCULATIONS FOR ENHANCED FASTENING AS ALLOWED BY
 LIMITATION #7 ON PAGE 32 OF THE NOA.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-02-13 Cont ID  
Sent By rmcdouga Date 2007-02-13 Time 15:07 Rev Time 0.00
Received By rmcdouga Date 2007-02-13 Time 15:07 Sent To  
Notes
2007-02-14 06:32:21DENIED BY BUILDING
  
 1) THE NOC HAS EXPIRED. IT WILL BE REQUIRED TO HAVE IT
 RERECORDED BEFORE THE PERMIT IS ISSUED.
  
 2)SUBMIT ENERGY CALCULATIONS FOR THE NEW ADDITION AS
 REQUIRED BY THE 2004 FBC CHAPTER 13.
  
 3) SUBMIT A SITE PLAN SHOWING COMPLIANCE WITH R401.3
 DRAINAGE .
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
 TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE
 GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM
 OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048
 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE
  
 4) SHOW COMPLIANCE WITH R322.1.1
 ALL NEW SINGLE-FAMILY HOUSES, DUPLEXES, TRIPLEXES,
 CONDOMINIUMS AND TOWNHOUSES SHALL PROVIDE AT LEAST ONE
 BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE
 BATHROOMS ARE PROVIDED ON HABITABLE GRADE LEVELS, WITH
 A DOOR THAT HAS A 29-INCH (737 MM) CLEAR OPENING.
 HOWEVER, IF ONLY A TOILET ROOM IS PROVIDED AT GRADE
 LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF
 NOT LESS THAN 29 INCHES (737 MM). ADDITIONS AND ALTERED
 SPACES ARE REQUIRED TO COMPLY. SEE FBC CHAPTER 11.
  
 5) SHOW COMPLIANCE WITH R807.1 ATTIC ACCESS.
 IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF
 CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED
 TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8 M 2 )
 AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR
 GREATER.
 THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22
 INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE
 LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE
 LOCATION. A 30-INCH (762 MM) MINIMUM UNOBSTRUCTED
 HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME
 POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3
 FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS
 LOCATED IN ATTICS.
  
 6) SPECIFY THE SIZE AND SPACING OF THE ROOF
 VENTILATION.
 R806.1 VENTILATION REQUIRED.
 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE
 CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF
 RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE
 SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE
 ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE
 PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WIT H 1 /
 8 INCH (3.2 MM) MINIMUM TO ? INCH (6.4 MM) MAXIMUM
 OPENINGS.
 R806.2 MINIMUM AREA.
 THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS
 THAN 1 TO 150 OF THE AREA OF THE SPACE VENTILATED
 EXCEPT THAT THE TOTAL AREA IS PERMITTED TO BE REDUCED
 TO 1 TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE
 THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA IS
 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF
 THE SPACE TO BE VENTILATED AT LEAST 3 FEET (914 MM)
 ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE
 REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS.
 AS AN ALTERNATIVE, THE NET FREE CROSS-VENTILATION AREA
 MAY BE REDUCED TO 1 TO 300 WHEN A VAPOR BARRIER HAVING
 A TRANSMISSION RATE NOT EXCEEDING 1 PERM (57.4 MG/S ? M
 2 ? PA) IS INSTALLED ON THE WARM SIDE OF THE CEILING.
  
 7) BASED ON THE 2006 REVISIONS TO THE 2004 FBC WHICH
 BECAME EFFECTIVE ON DECEMBER 8, 2006, THE STRUCTURE IS
 LOCATED IN EXPOSURE CATEGORY C. PLEASE CORRECT ON SHEET
 S1 AND ADJUST THE OPENING PRESSURES ACCORDINGLY.
  
 8)ROOF SHEATHING IS REQUIRED TO BE IN ACCORDANCE WITH
 SECTION R803.2.3.1 OF 2006 REVISIONS TO 2004 FBC
 RESIDENTIAL CODE. WOOD STRUCTURAL PANEL SHEATHING SHALL
 BE FASTENED TO ROOF FRAMING WITH 8D RING-SHANK NAILS AT
 6 INCHES ON CENTER AT EDGES AND 6 INCHES ON CENTER AT
 INTERMEDIATE FRAMING. SPACING OF RING-SHANK FASTENERS
 SHALL BE 4 INCHES ON CENTER IN NAILING ZONE 3 FOR 130
 MPH OR GREATER DESIGNWIND SPEEDS IN ACCORDANCE WITH
 FIGURE R803.2.3.1. PLEASE SPECIFY ON THE PLANS.
  
 9) SPECIFY THE ROOF SLOPE ON THE PLANS. TRUSS DRAWINGS
 ARE FOR5/12 PITCH.
  
 10) PROVIDE A FRAMING AND ATTACHMENT DETAIL FOR THE
 ARCH AT THE COVERED ENTRY.
  
 11)SPECIFY THE SIZES AND TYPE OF WINDOWS IN THE
 EXISTING REAR BEDROOM. IF THE WINDOW THAT IS BEING IN
 FILLED CONFORMS WITH EMERGENCY ESCAPE REQUIREMENTS OF
 R310.1 OR IS LARGER THAN THE REMAINING ONE, THEN THE
 REMAINING WINDOW WILL NEED TO BE CHANGED TO CONFORM.
 EXISTING BUILDING CODE 501.2 CONFORMANCE.
 AN EXISTING BUILDING OR PORTION THEREOF SHALL NOT BE
 ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE OR
 ENERGY EFFICIENT THAN ITS EXISTING CONDITION. IF IN THE
 ALTERATION THE CURRENT LEVEL OF SAFETY OR SANITATION IS
 TO BE REDUCED, THE PORTION ALTERED SHALL CONFORM TO THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING .
  
 12) THE TRUSS LAYOUT IS REQUIRED TO BE SIGNED, DATED
 AND SEALED BY THE TRUSS ENGINEER. FS 471. THE DESIGNER
 OF RECORD FOR THE STRUCTURE IS REQUIRED TO REVIEW AND
 APPROVE THE TRUSS LAYOUT IN WRITING.
  
 13) THE TRUSS DRAWINGS ARE REQUIRED TO HAVE THE
 ORIGINAL SIGNATURE OF THE ENGINEER. SIGNATURE STAMPS
 ARE NOT ACCEPTABLE. FS 471 AND FAC 61G15-23.002
  
 14) THE TRUSS LAYOUT AND DRAWINGS DO NOT CORRESPOND TO
 THE ROOF FRAMING PLAN ON S1. THE ENTRY PORCH IS A GABLE
 ON TRUSS DRAWINS AND A HIP ON THE PLANS. THE TRUSS
 DRAWINGS SHOW THE TRUSSES STOPPING AT THE WALL OF THE
 EXISTING STRUCTURE AND THE FRAMING PLAN SHOWS THEM
 EXTENDING PAST THE WALL AND STRAPPED TO EXISTING
 TRUSSES. PLEASE CORRECT.
  
 15) THE STRAPPING SCHEDULE ON S1 INCORRECTLY SPECIFIES
 (7) NAILS TO THE TRUSS FOR THE SIMPSON HTSM16. THE
 CATALOG REQUIRES (8).
  
 16)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 17) SUBMIT PRODUCT APPROVALS FOR THE SOLAR TUBE
 SKYLIGHT. IMPACT PROTECTION REQUIRED.
  
 18) SUBMIT PRODUCT APPROVALS FOR THE FLAT ROOF PORTION
 OF THE ROOF. FROM THE PRODUCT APPROVAL SPECIFY THE
 SYSTEM THAT WILL BE INSTALLED AND THE FASTENING OPTION
 AND DESIGN PRESSURE THAT WILL BE USED. IF ENHANCED
 FASTENING IS REQUIRED AT PERIMETER AND CORNERS, SUBMIT
 RAS 117 CALCULATION.
  
 19) SUBMIT THE UPDATED NOA FOR THE PGT FD101 FRENCH
 DOOR. NOA 06-0807.07 HAS REVISED 02-0927.13.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-08-29 Cont ID  
Sent By btrobaug Date 2007-08-29 Time 13:40 Rev Time 0.00
Received By btrobaug Date 2007-08-29 Time 12:03 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-06-13 Cont ID  
Sent By btrobaug Date 2007-06-13 Time 07:38 Rev Time 1.00
Received By btrobaug Date 2007-06-13 Time 06:41 Sent To P
Notes
2007-06-13 07:38:39 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
 IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417
 FS, RESPECTIVELY.
  
 2} PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT
 SIZE AND TYPE, GROUNDING DETAILS. SEE 230.70 FOR
 DISCONNECT REQUIREMENTS. IT APPEARS AS THOUGH THE
 ENTRANCE CONDUCTORS WILL BE ROUTED OVERHEAD GIVEN THE
 LOCATIION OF THE PANEL WITH RESPECT TO THE RELOCATED
 SERVICE, THEREFORE A DISCONNECT WOULD BE NEEDED AT THE
 METER. INDICATE IF OVERHEAD OR UNDER GROUND, THE NOTE
 AT THE RISER AND THE RISER DIAGRAM ARE IN CONFLICT.
  
 3} SEE ARTICLE 250.66 FOR GEC SIZE, 250.50 FOR GEC
 REQUIREMENTS, ESPECIALLY NOTE 250.52(A)(3), CONCRETE
 ENCASED, SINCE AVAILABLE, WILL BE REQUIRED.
  
 4} PROVIDE A PANEL SCHEDULE PER 408.4. PLEASE SEE NEW
 VERBAGE FOR 2005 NEC: "THE IDENTIFICATION SHALL INCLUDE
 SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE
 DISTINGUISHED FROM ALL OTHERS." THE SCUDULE PROVIDED
 HDOES NOT LIST THE REQUIRED CIRCUITS PER ARTICLE 210.
 ALSO THE SCHEDULE SHOWS NO AHU, THERE ARE 2 WATER
 HEATERS IN THE CALCS, NONE ON THE SCHEDULE,
 DISHWASHER/DISPOSAL, WHIRLPOOL, NO REQUIRED BATH
 CIRCUIT(210.11(C)(3),
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-01-08 Cont ID  
Sent By btrobaug Date 2007-01-08 Time 16:45 Rev Time 0.00
Received By btrobaug Date 2007-01-08 Time 14:14 Sent To P
Notes
2007-01-08 16:45:18 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1}INDICATE IF THE RISER DIAGRAM SHOWN FOR THE SERVICE
 IS NEW OR EXISTING.THE CALCULATIONS INDICATE EXISTING,
 BUT THE RISER ASKS FOR PULL STRINGS, INDICATING THE
 WIRES HAVE NOT YET BEEN INSTALLED. VERIFY THAT A
 CURRENT TRANSFORMER TYPE METERING SYSTEM IS AVAILABLE
 AT THIS RESIDENCE.
  
 2} REGARDING THE ELECTRICAL NOTES, #4 REFERENCES A
 TEMPORARY SERVICE FOR CONSTRUCTION. A RISER DIAGRAM AND
 A SEPERATE PERMIT WILL BE REQUIRED FOR SAME.
  
 3} SUBMIT A PANEL SCHEDULE PER 408.4 NEC AND
 106.3.5.4(8) FBC.
  
 4} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.1
 RESIDENTIAL FLORIDA BUILDING CODE.
  
 5} SHOW COMPLIANCE WITH THE REQUIRED RECEPTACLEAT THE
 CONDENSING UNIT PER 210.63.
  
 6} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.2. FBC.
 THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK MUST
 SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002 FAC.
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-10-24 Cont ID  
Sent By adarroug Date 2007-10-24 Time 12:01 Rev Time 0.00
Received By adarroug Date 2007-10-24 Time 12:01 Sent To B
Notes
2007-10-24 12:01:56TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-09-11 Cont ID  
Sent By adarroug Date 2007-09-11 Time 15:48 Rev Time 0.00
Received By adarroug Date 2007-09-11 Time 15:48 Sent To Z
Notes
2007-09-11 15:49:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-08-23 Cont ID  
Sent By adarroug Date 2007-08-23 Time 14:35 Rev Time 0.00
Received By adarroug Date 2007-08-23 Time 14:35 Sent To E
Notes
2007-08-23 14:35:37TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-06-07 Cont ID  
Sent By adarroug Date 2007-06-07 Time 08:48 Rev Time 0.00
Received By adarroug Date 2007-06-07 Time 08:48 Sent To E
Notes
2007-06-07 08:48:18TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-06-04 Cont ID  
Sent By adarroug Date 2007-06-04 Time 10:21 Rev Time 0.00
Received By adarroug Date 2007-06-04 Time 10:21 Sent To Z
Notes
2007-06-04 10:21:48TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-01-02 Cont ID  
Sent By adarroug Date 2007-01-02 Time 16:29 Rev Time 0.00
Received By adarroug Date 2007-01-02 Time 16:29 Sent To E
Notes
2007-01-02 16:29:22TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-02-13 Cont ID  
Sent By rmcdouga Date 2007-02-13 Time 15:07 Rev Time 0.00
Received By rmcdouga Date 2006-12-22 Time 16:56 Sent To  
Notes
2006-12-22 16:56:47TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-08-30 Cont ID  
Sent By tgordon Date 2007-08-30 Time 10:53 Rev Time 0.25
Received By tgordon Date 2007-08-30 Time 10:53 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-06-22 Cont ID  
Sent By tgordon Date 2007-06-22 Time 09:45 Rev Time 0.30
Received By tgordon Date 2007-06-22 Time 09:45 Sent To B
Notes
2007-06-22 09:54:59*** DENIED ***
 1) SEE PLANS PAGE M/P/E-1, ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 PRINTED NAME AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR THE DESIGN. PER FBC 104.2.1 .
  
 2) THE ENERGY CALCULATIONS NEED TO BE SIGNED BY THE
 PREPARER ALSO, SEE 2004 FBC 13-600.3.ABC.1.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-01-18 Cont ID  
Sent By tgordon Date 2007-01-18 Time 11:34 Rev Time 0.45
Received By tgordon Date 2007-01-18 Time 11:34 Sent To B
Notes
2007-01-18 12:10:44*** DENIED ***
 1) PLEASE SUBMIT ENERGY CALCULATIONS, PER 2004 FBC
 13-101.2.2.
  
 2) PLEASE SUBMITMANUAL J CALCULATIONS, PER 2004 FBC
 13-607.1.ABC.1 .
  
 3) SEE ONE SET OF PLANS PAGE M/P/E-1 HAS AN ENGINEER'S
 NAME AND INFORMATION IN THE TITLE BLOCK , SO HIS
 SIGNATURE AND SEAL MUST ALSO APPEAR IN THE TITLE BLOCK,
 PER FAC 61G15-23.002.
  
 4) PLEASE SHOW AN EQUIPMENT (A/C) LISTING WITH ALL
 PERTINENT INFORMATION ON THE MECHANICAL PLANS.
  
 5) THE RETURN AIR GRILL CAN NOT BE LOCATED IN THE
 MASTER BATHROOM, PER 2004 FBC/R M1602.2(4), PLEASE
 CORRECT.
  
 6) THE MASTER BATHROOM WITH THE TUB WILL REQUIRE AN
 EXHAUST FAN, PER 2004 FBC/R R303.3, PLEASE CORRECT.
  
 7) PLEASE SHOW THE SIZE OF ALL SUPPLY AND RETURN AIR
 GRILLS ON PLANS.
  
 8) PLEASE SHOW THE SIZE OF THE RETURN AIR DUCT (FLEX)
 ON MECHANICAL PLANS.
  
 *** INFORMATIONAL ***
 BALANCED RETURN AIR MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-08-30 Cont ID  
Sent By mperson Date 2007-08-30 Time 08:15 Rev Time 0.00
Received By mperson Date 2007-08-30 Time 08:15 Sent To M
Notes
2007-08-30 08:22:52****************PROVISO****************
 PER FBC-2004 PLUMBING SECTION 607.3 A MEANS OF
 CONTROLLING INCREASED PRESSURE CAUSED BY THERMAL
 EXPANSION SHALL BE PROVIDED WHERE REQUIRED IN
 ACCORDANCE WITH SECTIONS 607.3.1 AND 607.3.2.
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-06-22 Cont ID  
Sent By mperson Date 2007-06-22 Time 08:10 Rev Time 0.45
Received By mperson Date 2007-06-22 Time 08:10 Sent To M
Notes
2007-06-22 08:14:48DENIED 2ND TIME
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 FUEL GAS.
 ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION
 REQUIREMENTS.
 ** FBC-2004 CHAPTER 1, THE CITY OFDENIED REFERENCE:
 FBC-2004 PLUMBING, FBC-2004 CHAPTER 1, CITY OF WEST
 PALM BEACH AMENDMENTS, AND FLORIDA ADMINISTRATIVE
 CODE.
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL
 IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS,
 SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING
 REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT
 MADE ON PREVIOUS REVIEWS.
  
 ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM
 PREVIOUS REVIEW WITH A NO, OK OR A NO/OK.
 THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE
 PREVIOUS REVIEW NOTES.
  
 A NO IS IF THE COMMENT WAS NOT FULLY ADDRESSED AND/OR
 FURTHER EXPLANATION OR CHANGES IN PLANS OR DOCUMENTS
 ARE STILL NEEDED. THIS REVIEWER WILL TRY TO BETTER
 EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT.
  
 AN OK WILL BE LABELED AS SUCH ON THE SAME NUMERICAL
 COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS.
  
 A NO/OK MEANS PART OF THE COMMENT MAY HAVE BEEN
 ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW
 COMMENT MAY HAVE BEEN FULLY ADDRESSED.
  
 ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF
 THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH.
  
 1. **NO**FBC-2004 CHAPTER 1,SECTION 106.3.4.3:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME. IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND
 417 FS, RESPECTIVELY.
  
 2. **OK**
  
 3. **NO/OK** SHEET M/P/E-1 WATER HEATER DETAIL, THE
 FOLLOWING IS STILL REQUIRED AND NEEDS TO BE SHOWN ON
 THE RESUBMITTAL:
 A} **OK**
 B} **OK**
 C} **OK**
 D} **OK**
 E} **OK**
 F} **OK**
 G} **OK**
 H} **NO** PER FBC-2004 PLUMBING, SECTION 607.3,
 THERMAL EXPANSION CONTROL REQUIRED. PLEASE ADD THE
 THERMAL EXPANSION PROTECTION ON THE RESUBMITTED WATER
 HEATER DETAIL.
  
 THE FOLLOWING ARE NEW ITEMS:
  
 4. SHEET M/P/E-1 ELECTRIC WATER HEATER DETAIL: THE
 NEWLY SUBMITTED ELECTRIC WATER HEATER DETAIL IS
 INDICATING A BOTTOM FED WATER HEATER. PLEASE ADD THE
 FOLLOWING FOR THIS HEATER PER FBC-2004 PLUMBING,
 SECTION 504.2 A BOTTOM FED WATER HEATER SHALL HAVE A
 VACUUM RELIEF VALVE INSTALLED. THE VACUUM RELIEF SHALL
 COMPLY WITH ANSI Z21.22. PLEASE INDICATE THIS ON THE
 RESUBMITTAL.
  
 5. SHEET M/P/E-1 PLUMBING RISER: THE RESUBMITTED
 ISOMETRIC RISER DIAGRAM IS INDICATING A 4" X 4" X 3"
 COMBINATION-WYE AND EIGHTH BEND TO THE WATER CLOSET.
 PLEASE DELETE THIS AND THE OFFSET TO THE WATER CLOSET
 AND ADD A 4" QUARTER BEND IN ITS PLACE FOR THE
 RESUBMITTAL.
  
 **********IMPORTANT INFORMATION
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-01-18 Cont ID  
Sent By mperson Date 2007-01-18 Time 16:01 Rev Time 0.55
Received By mperson Date 2007-01-17 Time 16:01 Sent To M
Notes
2007-01-17 16:57:51DENIED
 REFERENCE: FBC-2004 PLUMBING, FBC-2004 CHAPTER 1, CITY
 OF WEST PALM BEACH AMENDMENTS, AND FLORIDA
 ADMINISTRATIVE CODE.
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING
 PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. FBC-2004 CHAPTER 1,SECTION 106.3.4.2:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME, AND ALSO DATE DRAWING. PER FAC-61G15-23.002 THE
 ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK MUST
 SIGN, DATE, AND SEAL THE DOCUMENT.
  
 2. SHEET M/P/E-1 ISOMETRIC SANITARY RISER DIAGRAM AND
 PLUMBING PLAN THE FOLLOWING IS REQUIRED AND NEEDS TO BE
 INDICATED ON THE RESUBMITTAL. PLEASE REFERENCE THE
 CORRECTED SANITARY RISER DIAGRAM THAT IS CODE COMPLIANT
 ATTACHED TO THE PLUMBING COMMENTS FOR THE SUBMITTAL: A}
 PER FBC-2004 PLUMBING, SECTION 905.3, THE HORIZONTAL
 DRY VENT IS NOT ALLOWED. B} PER FBC-2004 PLUMBING,
 TABLE 906.1, VENT REQUIRED FOR SPA/TUB.
  
 3. SHEET M/P/E-1 WATER HEATER DETAIL, THE FOLLOWING IS
 REQUIRED AND NEEDS TO BE SHOWN ON THE RESUBMITTAL:A}
 PER FBC-2004 PLUMBING, SECTION 504.4, RELIEF VALVE
 REQUIRED. B} PER FBC-2004 PLUMBING, SECTION 504.6,,
 RELIEF OUTLET REQUIRED. C} PER FBC-2004 PLUMBING,
 SECTION 504.6.1, RELIEF DISCHARGE. D} PER FBC-2004
 PLUMBING, SECTION 504.7, REQUIRED PAN. E} PER FBC-2004
 PLUMBING, SECTION 504.7.1, PAN DRAIN AND SIZE. F} PER
 FBC-2004 PLUMBING, SECTION 504.7.2, PAN DRAIN
 TERMINATION. G} PER FBC-2004 PLUMBING, SECTION 606.1,
 FULL OPEN VALVE REQUIRED ON WATER HEATER SUPPLY H}PER
 FBC-2004 PLUMBING, SECTION 60703, THERMAL EXPANSION
 CONTROL REQUIRED.
  
 **********IMPORTANT INFORMATION
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 3 Status P Date 2007-09-14 Cont ID  
Sent By choops Date 2007-09-14 Time 12:13 Rev Time 0.00
Received By choops Date 2007-09-14 Time 12:13 Sent To B
Notes
2007-09-14 12:14:23A/C EQUIPMENT SHALL NOT BE CLOSER THAN 3' TO SIDE
 PROPERTY LINE.

Review Stop Z ZONING
Rev No 2 Status P Date 2007-06-05 Cont ID  
Sent By choops Date 2007-06-05 Time 14:37 Rev Time 0.00
Received By choops Date 2007-06-05 Time 14:37 Sent To I
Notes
2007-06-05 14:38:18PROVISO:PROPOSED A/C EQUIPMENT NOT TO BE CLOSER THAN
 3' TO SIDE PROPERTY LINE.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-12-29 Cont ID  
Sent By mmclean Date 2006-12-29 Time 07:46 Rev Time 0.00
Received By mmclean Date 2006-12-29 Time 07:46 Sent To I
Notes
2006-12-29 08:16:20DENIED,
 1. PLEASE PROVIDE THE SETBACKS OF THE PROPOSED ADDITION
 AND EXISTING STRUCTURE ON THE TWO COPIES OF SURVEYS.
 2. SURVEYS SUBMITTED DOES NOT SHOW THE SETBACK OF THE
 ADDITION AND EXISTING STRUCTURE.
 3. SURVEYS SHALL SHOW THE PROPOSED COVERED FRONT ENTRY
 WITH SETBACK.
 4. SITEPLANS SUBMITTEDHAS INSUFFICIENT INFORMATION
 (NO SETBACKS OF THE EXISTING AND PROPOSED ADDITION).
 5. THE DRIVEWAY ON SURVEYS AND SITEPLANS DOES NOT
 MATCH, IF PROPOSING A NEW DRIVEWAY, PLEASE PROVDE THE
 WIDTH & LENGTH.
 6. PLEASE SHOW THE NEW A/C UNIT ON THE TWO COPIES OF
 SURVEYS.
  
 NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF LANDSCAPE,
 WHICHEVER IS LESS WITHIN THE FIRST 25FT FRONT SETBACK.
  
 NOTE: SF7, SIDE SETBACK MIN 5FT; BOTH SIDES TOTALLING
 15FT.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720