Plan Review Stops For Permit 06120498 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2007-07-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-07-16 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-07-16 |
Time |
16:50 |
Sent To |
|
|
Notes |
2007-07-16 16:52:36 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FAC FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | | | 1.)ROOFING PERMIT REQUIRED.THIS IS NOT WITHIN THE | | SCOPE OF A CBC LICENSE. | | | | 2.)SELECT THE APPROVED ASSEMBLY YOU ARE USING.ALSO | | INDICATE WHICH FASTENER YOU ARE USING IF THE OPTIONS | | HAVE DIFFERENT PRESSURE LIMITATIONS. | | | | 3.)SPECIFY THE ENHANCED FASTENING FOR CORNER AND | | PERIMETER ZONES. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-06-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-06-25 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-06-25 |
Time |
09:53 |
Sent To |
|
|
Notes |
2007-06-25 09:53:27 | RESTAMP OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-04-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-04-06 |
Time |
17:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-04-06 |
Time |
17:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-02-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-02-01 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-02-01 |
Time |
15:47 |
Sent To |
|
|
Notes |
2007-02-01 15:49:57 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | 1.)PLAN SPECIFIES HUGHES CONNECTORS.THEY HAVE BEEN | | OUT OF BUSINESS FOR MANY YEARS.SPECIFY AN AVAILABLE | | CONNECTOR. | | | | 2.)PLANS ARE NOT CLEAR.THE BOX APPEARS TO BE | | OPEN,BUTDESIGN CRITERIA GIVES AN INTERNAL PRESSURE | | COEFFICIENT OF .18 WHICH IS FOR ENCLOSED BUILDINGS. | | NOTE THE TYPE OF SIDING, OR REVISE CRITERIA. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-07-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-16 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-16 |
Time |
15:57 |
Sent To |
B |
|
Notes |
2007-07-16 15:58:20 | TO "SHILL" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-06-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-22 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-22 |
Time |
13:52 |
Sent To |
B |
|
Notes |
2007-06-22 13:53:33 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-03-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-13 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-13 |
Time |
11:24 |
Sent To |
B |
|
Notes |
2007-03-13 11:24:42 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-03-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-06 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-06 |
Time |
15:59 |
Sent To |
Z |
|
Notes |
2007-03-06 16:00:19 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-12-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-28 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-28 |
Time |
09:00 |
Sent To |
B |
|
Notes |
2006-12-28 09:01:28 | TO "MISC" BOX#2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-02-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-02-01 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-12-19 |
Time |
14:10 |
Sent To |
|
|
Notes |
2006-12-19 14:10:51 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-03-08 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-03-08 |
Time |
18:25 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-03-08 |
Time |
18:25 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-12-27 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-12-27 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-12-27 |
Time |
08:54 |
Sent To |
I |
|
Notes |
2006-12-27 08:56:19 | DENIED, | | 1. PLEASE SUBMIT TWO COPIES OF SURVEYS/SITEPLAN OF THE | | WHOLE PROPERTY SHOWING THE LOCATION OF THE PROPOSED | | SCORE BOXES. | | 2. IF THE SCORE BOXES IS LOCATED TO THE PROPERTY LINE, | | PLEASE INDICATE THE DISTANCE FROM THAT PROPERTY LINE AS | | WELL AS ANY OTHER STRUCTURE. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|