Plan Review Stops For Permit 06120256 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-02-05 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-02-05 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-02-05 |
Time |
15:38 |
Sent To |
PC |
|
Notes |
2007-02-05 16:18:41 | BUILDING PROVISO: | | TO BE IN PLACE AT C.O.: | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | WITH A BARRIER COMPLYING WITH | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | ASTM D5034 100 LB TENSILE STRNGTH | | ASTM D3787 150 LB BALL BURST STRENGTH | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | EQUIPPED WITH A COVER DESIGNED TO | | MINIMIZE HEAT LOSS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-01-02 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-01-02 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-01-02 |
Time |
06:01 |
Sent To |
PC |
|
Notes |
2007-01-02 10:26:37 | BUILDING PLAN REVIEW | | PERMIT:06120256 | | ADD:2389SARATOGA BAY DR. | | CONT: THE POOL PEOPLE EAST. | | TEL: (954)428-3300 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 1ST | | ACTION: DENIED | | | | 1) PROVIDE DETAIL ENGINEERED DRAWINGS FOR THE CBS WALL | | AND ALUMINIUM FENCE IN COMPLIANCE WITH THE WIND DESIGN | | DATA FBC. 1603.1.4. THE VALUE FOR THE WALL SHALL BE | | INCLUDED IN THE TOTAL VALUE OF THE PROJECT.PROVIDE A | | FRONT ELEVATION OF THE 6' AND 8' CBS WALL INDICATING | | ALL SUPPORTS AND THE HEIGHT OF THE WALL. | | | | 2) ON THE PERMIT APPLICATION, STATE IF THE CBS WALL | | WILL BE CONSTRUCTED OR IF IT IS EXISTING. CONSTRUCTION | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED | | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE RELEVANT | | CODE, LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. FBC. 106.1.1. | | | | 3)THE CBS WALL SHALL MEET THE REQUIREMENTS OF | | SEC.1609.1.3. THE STRUCTURE SHALL BE ANCHORED TO RESIST | | WIND-INDUCED OVERTURNING, UPLIFT AND SLIDING TO PROVIDE | | CONTINUOUS LOAD PATHS FOR THESE FORCES TO THE | | FOUNDATION. | | | | 4)A SEPERATE PERMIT IS REQUIRED FOR THE FENCE. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2006-12-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-12-21 |
Time |
11:48 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-12-21 |
Time |
11:23 |
Sent To |
P |
|
Notes |
2006-12-21 11:39:09 | | | | | PROVISO | | PERMIT FOR ELECTRICAL SERVICE UPGRADE TO 200 AMPS MUST | | BE ISSUED PRIOR TO POOL EQUIPMENT HOOK UP. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-02-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-13 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-13 |
Time |
09:52 |
Sent To |
Z |
|
Notes |
2007-02-13 09:53:21 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-02-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-05 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-05 |
Time |
14:09 |
Sent To |
Z |
|
Notes |
2007-02-05 14:09:49 | TO "MJACOBS" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-01-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-30 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-30 |
Time |
11:33 |
Sent To |
Z |
|
Notes |
2007-01-30 11:33:29 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-12-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-18 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-18 |
Time |
13:09 |
Sent To |
E |
|
Notes |
2006-12-18 13:09:28 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-01-02 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-11 |
Time |
10:23 |
Sent To |
|
|
Notes |
2006-12-11 10:23:28 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2006-12-26 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-12-26 |
Time |
08:19 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2006-12-26 |
Time |
08:19 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-02-15 |
|
|
Cont ID |
|
Sent By |
adavila |
Date |
2007-02-15 |
Time |
18:03 |
Rev Time |
0.00 |
Received By |
LFRANCO |
Date |
2007-02-15 |
Time |
18:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-02-03 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2007-02-03 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2007-02-03 |
Time |
11:09 |
Sent To |
I |
|
Notes |
2007-02-03 11:11:34 | DENIED, | | 1. THE SUBMITTED DOCUMENTS DOES NOT INCLUDE THE HOA | | (ARCHITECTURAL CONTROL COMMITTEE) APPROVAL FOR THE | | PROPOSED WORK. | | 2. PLEASE PROVIDE TWO COPIES OF THE HOA APPROVAL FOR | | THE PROPOSED WORK. | | | | | | NOTE:SEC 94-304(2)(B) - EVERY SWIMMING POOL SHALL BE | | ENCLOSED BY A FENCE OR SIMILAR STRUCTURE WHICH IS | | INSTALLED TO OBSTRUCT ACCESS BY PERSONS OTHER THAN THE | | OWNERS OR OCCUPANTS OF THE RESIDENCE WITHIIN WHICH A | | SWIMMING POOL IS LOCATED.BARRIERS OR FENCES SHALL BE | | AT LEAST FOUR FEET IN HEIGHT ABOVE GRADE. | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-12-16 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-12-16 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-12-16 |
Time |
15:50 |
Sent To |
I |
|
Notes |
2006-12-16 16:03:31 | DENIED, | | 1. PLEASE PROVIDE APPROVAL FROM THE ARCHITECTURAL | | CONTROL COMMITTE FOR THE PROPOSED POOL/SPA/FENCE/WALL. | | 2. PLEASE CLARIFY IF THE PROPOSED WALL AND FENCE WILL | | BE INCLUDED IN PROPOSED WORK.IF SO, PLEASE INCLUDE IN | | THE DESCRIPTION ON PERMIT APPLICATION AND COMPUTER. | | 3. NEED TO PROVIDE ALL EASEMENT APPROVAL FOR THE WALL | | IN THE REAR OF THE PROPERTY FROM BELLSOUTH, | | ADELPHIA/COMCAST, FPL, FPU,CITY OF WEST PALM BEACH | | UTILITY DEPT (12U.E. AND 22'LANDSCAPE & WALL | | EASEMENT). | | 4. PLEASE PROVIDE TWO COPIES OF WALL DETAIL, SHOWING | | THE HEIGHT OF THE PROPOSED CBS WALL. | | 5. WALL CANNOT BE APPROVED ON THE NEIGHBORING PROPERTY, | | PLEASE SHOW ON BOUNDARY LINE (NOT HIGHLIGHTED). | | 6. PLEASE SHOW THE POOL EQUIPMENT ON TWO COPIES OF | | SURVEY WITH SETBACKS. | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|