Plan Review Stops For Permit 06110744 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2006-12-11 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2006-12-11 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2006-12-11 |
Time |
16:14 |
Sent To |
|
|
Notes |
2006-12-11 16:15:47 | ASSIGN PERMIT TO UNIT 400 ( UNIT 0001, UNDER PCN = | | 74434321060360060) | | | | LACRAMIOARA URSU | | MIS - GIS SUPPORT SPECIALIST | | E-MAIL:[email protected] | 2006-12-10 08:03:05 | MADE COPY AND SENT TO ADDRESSING. DV PALMER |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-04-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-04-09 |
Time |
14:53 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2007-04-09 |
Time |
14:43 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-01-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-01-30 |
Time |
10:32 |
Rev Time |
1.22 |
Received By |
jwitmer |
Date |
2007-01-30 |
Time |
10:32 |
Sent To |
|
|
Notes |
2007-01-30 10:37:13 | BUILDING PLAN REVIEW | | PERMIT: 06110744 | | ADD: 444 W RAILROAD AVSUITE# 400 | | CONT:PBM DEVELOPMENT | | TEL: (561)715-1800 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1STREVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) PBM DEVELOPMENT REQUIES A CERTIFICATE OF | | AUTHORIZATION. | | 481.219 F.S.CERTIFICATE OF | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | SHEET BEARING THE NAME OF AN ARCHITECT | | PRACTICING UNDER A FICTITIOUS NAME, A | | CORPORATION, OR A PARTNERSHIP, OFFERING ARCHITECTURAL | | SERVICES, SHALL INCLUDE | | THE CERTIFICATE OF AUTHORIZATION | | NUMBER.ADD THE NUMBER TO EACH SHEET. | | THIS MAY BE ADDED BY HAND. | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-12-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-12-13 |
Time |
12:06 |
Rev Time |
1.55 |
Received By |
jwitmer |
Date |
2006-12-13 |
Time |
11:35 |
Sent To |
|
|
Notes |
2006-12-13 12:24:14 | BUILDING PLAN REVIEW | | PERMIT: 06110744 | | ADD: 444 W RAILROAD AVSUITE# 400 | | CONT:PBM DEVELOPMENT | | TEL: (561)715-1800 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1STREVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) ADDITIONAL INFORMATION REQUIRED. 106.1.2* | | THIS COMMENT SHALL DEAL WITH THE EXIT ACCESS CORRIDOR. | | THE SHELL PERMIT REMOVED THE EXIT ACCESS CORRIDORS | | FROM | | | | THEIR SCOPE OF WORK. | | EITHER ONE OF TWO THINGS WILL NEED TO HAPPEN. UNDER THE | | SHELL PERMIT PUT A REVISION IN TFOR THE FOURTH FLOOR | | CORRIDORS OR MAKE THE FOURTH FLOOR CORRIDORS PART OF | | THIS PERMIT. | | SHEET A-02 INDICATES THAT THE EXIT ACCESS CORRIDORS ARE | | EXISTING. | | | | 3) SHEET A-02THE FOLLOWING DOORS ARE MISSING THE 18" | | ON | | THE LATCH/ PULL SIDEOF THE DOOR: 404, 408,409 & 416. | | 11-4.13.6 MANEUVERING CLEARENCES | | AT DOORS. MINIMUM MANEUVERING CLEARANCES | | AT DOORS THAT ARE NOT AUTOMATIC OR | | POWER-ASSISTED SHALL BE AS SHOWN IN | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | IN THE REQUIRED CLEARANCES SHALL BE | | CLEAR & LEVEL.11-4.4.4 PROTRUDING OBJECTS. OBJECTS | | PROJECTING FROM WALLS (FOR EXAMPLE, TELEPHONES) WITH | | THEIR | | LEADING EDGES BETWEEN 27 INCHES AND 80 INCHES (685 MM | | AND 2030 MM) | | ABOVE THE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4 | | INCHES (102 MM) | | INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES | | [SEE FIGURE 11-8 (A)]. | | OBJECTS MOUNTED WITH THEIR LEADING EDGES AT OR BELOW 27 | | INCHES (685 MM) | | ABOVE THE FINISHED FLOOR MAY PROTRUDE ANY AMOUNT [SEE | | FIGURE 11-8 (A) AND | | FIGURE 11-8 (B)]. FREE-STANDING OBJECTS MOUNTED ON | | POSTS OR PYLONS MAY | | OVERHANG 12 INCHES (305 MM) MAXIMUM FROM 27 INCHES TO | | 80 INCHES | | (685 MM TO 2030 MM) ABOVE THE GROUND OR FINISHED FLOOR | | [SEE FIGURE 11-8 (C) | | AND FIGURE 11-8 (D)]. PROTRUDING OBJECTS SHALL NOT | | REDUCE THE CLEAR WIDTH OF AN | | ACCESSIBLE ROUTE OR MANEUVERING SPACE [SEE FIGURE 11-8 | | (E)]. | | 1003.3.3 HORIZONTAL PROJECTIONS. | | ELEMENTS CANNOT PROJECT OVER A WALKING SURFACE MORE | | THAN 4 INCHES (102 MM) | | WHEN THEY ARE LOCATED BETWEEN 27 AND 80 INCHES (686 AND | | 2032 MM) ABOVE | | THE FLOOR. HANDRAILS CAN PROJECT UP TO 4? INCHES (114 | | MM) FROM THE WALL. | | | | 4) SHEET A-02 RESTROOM 407, PLEASE PROVIDE TURNING | | RADIUS WITHIN THE RESTROOM. | | 11-4.2.3 WHEELCHAIR TURNING SPACE. THE SPACE REQUIRED | | FOR A WHEELCHAIR TO M | | AKE A 180-DEGREE TURN IS A CLEAR SPACE OF 60 INCHES | | (1525 MM) DIAMETER [SEE | | FIGURE 11-3 (A)] OR A T-SHAPED SPACE [SEE FIGURE 11-3 | | (B)]. | | | | 5) SHEET A-02 RESTROOM PLEASE INDICATE THE CLEAR FLOOR | | SPACE REQUIRED FOR THE PLUMBING FIXTURES. 11-4.22.2 | | DOORS. ALL DOORS TO | | ACCESSIBLE TOLIET ROOMS SHALL COMPLY | | WITH 11-4.13. DOORS SHALL NOT SWING INTO | | CLEAR FLOOR SPACE REQUIRED FOR ANY | | FIXTURE. | | | | 6) SHEETA-06 BREAK ROOM THE PLANS DO NOT INDICATE A | | SINK BUT THE PLUMBING ISOMETRIC DOES. | | PLEASE PROVIDE CABINET DETAILSCOMPLYING WITH: | | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL | | BE MOUNTED WITH THE COUNTER NO HIGHER | | THAN 34" ABOVE THE FINISH FLOOR. | | 11-4.24.3 KNEE CLEARANCE THAT IS AT | | LEAST 27" HIGH 30" WIDE, AND 19" DEEP | | SHALL BE PROVIDED UNDERNEATH SINKS. | | | | 7)SHEET A-05 INDICATES VARIOUS DETAILS WITH CROWN | | MOULDINGS, NO MENTION OF TYPE OF MATERIAL, | | 2604.1 GENERAL. | | PLASTIC MATERIALS INSTALLED AS INTERIOR FINISH OR TRIM | | SHALL COMPLY WITH CHAPTER 8 . FOAM PLASTICS SHALL ONLY | | BE INSTALLED AS INTERIOR FINISH WHERE APPROVED IN | | ACCORDANCE WITH THE SPECIAL PROVISIONS OF SECTION | | 2603.8 . FOAM PLASTICS THAT ARE USED AS INTERIOR FINISH | | SHALL ALSO MEET THE FLAME SPREAD INDEX REQUIREMENTS FOR | | INTERIOR FINISH IN ACCORDANCE WITH CHAPTER 8 . FOAM | | PLASTICS INSTALLED AS INTERIOR TRIM SHALL COMPLY WITH | | SECTION 2604.2 . | | TRIM | | 2604.2 INTERIOR TRIM . | | FOAM PLASTIC USED AS INTERIOR TRIM SHALL COMPLY WITH | | SECTIONS 2604.2.1 THROUGH 2604.2.4 . | | | | 2604.2.1 DENSITY. | | THE MINIMUM DENSITY OF THE INTERIOR TRIM SHALL BE 20 | | PCF (320 KG/M 3 ). | | | | 2604.2.2 THICKNESS. | | THE MAXIMUM THICKNESS OF THE INTERIOR TRIM SHALL BE 0.5 | | INCH (12.7 MM) AND THE MAXIMUM WIDTH SHALL BE 8 INCHES | | (204 MM). | | | | 2604.2.3 AREA LIMITATION. | | THE INTERIOR TRIM SHALL NOT CONSTITUTE MORE THAN 10 | | PERCENT OF THE AGGREGATE WALL AND CEILING AREA OF ANY | | ROOM OR SPACE. | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2007-04-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-04-24 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-04-24 |
Time |
13:20 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2007-04-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-04-12 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-04-12 |
Time |
15:50 |
Sent To |
|
|
Notes |
2007-04-12 16:15:37 | ** UNSAT ** | | | | 1) NOTE: PLEASE SEE THE NEW REVISED ENERGY CALCULATIONS | | ARE NOT SEALED BY THE ENGINEER OF RECORD AS REQUIRED | | PER 13-103.1.1.1 | | PLEASE SUBMIT SIGNED, DATED AND SEALED. FS 471.025 | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2007-04-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-04-04 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-04-04 |
Time |
12:09 |
Sent To |
|
|
Notes |
2007-04-04 13:04:12 | ** UNSAT 2ND REVIEW ** | | | | 1) NOTE: PLEASE SEE NOTES FROM PREVIOUS REVIEW. THE | | ENERGY CALCULATIONS AND/OR PERFORMANCE DENSITIES WERE | | NOT SHOWN IN COMPLIANCE. PLEASE SEE THE TYPE, AND | | AMOUNT OF FIXTURES, WATTAGE(S) ETC AS SHOWN ON PLANS DO | | NOT CORRELATE WITH THE ENERGY CALCULATIONS SUBMITTED. | | PLEASE ADJUST AND REVISE 13-415.1.AB.1.1, 13-415.2 | | PLEASE SEE THE METHOD OF CONTROL FOR LIGHTING ON ENERGY | | CALCULATIONS NEEDS TO CORRELATE WITH PLANS. | | (AUTOMATED/OCCUPANCY/TIMERS ETC). | | | | 2) NOTE: PLEASE SEE THAT NO HAND DRAWN CHANGES ARE | | PERMITTED ON PLANS. | | PLEASE BE SURE TO STATE THE MAXIMUM TIMES FOR OCCUPANCY | | TYPE DEVICES ON PLANS. | | 13-415.1.ABC.1.1 | | | | 3) NOTE: PLEASE SEE THE REQUIRED LICENSE NUMBER FOR | | FIRM IS MISSING FROM SEVERAL SHEETS IN BOTH SETS OF | | PLANS. THIS IS NOT ONLY REQUIRED ON ONE SHEET, THIS IS | | REQUIRED FOR EVERY SHEET WHICH CONTAINS THE SAID TITLE | | BLOCK FOR FIRM. (PBM). FS 481.219, FAC 61G1-16.004 | | THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | OTHER TRADES. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2007-01-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-01-25 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-01-25 |
Time |
14:32 |
Sent To |
|
|
Notes |
2007-01-25 14:33:05 | ** UNSAT ** | | | | 1) NOTE: PLEASE SEE NOTE #1 FROM PREVIOUS REVIEW. IT IS | | NOTED THAT APPLICATION HAS BEEN MADE TO DBPR, HOWEVER | | UNTIL ISSUANCE OF THE FIRM LICENSE NUMBER HAS BEEN | | DONE, CONFIRMED AND ON TITLE BLOCKS, WE ARE NOT ABLE TO | | STAMP OR PASS PLANS EVEN IF APPLICATION IS MADE. PLEASE | | KNOW THAT THIS OFFICE HAS BEEN IN CONTACT WITH THE | | STATE'S LEGAL COUNSEL ON THIS MATTER AND WE HAVE BEEN | | INFORMED DIRECTLY ON THIS MATTER. | | FS 481.219, FAC 61G1-16.004. | | | | 2) NOTE: PLEASE SEE SECRETARIES FILE AREA MISSING | | CONTROL FOR LIGHTING PER 13-415.1.ABC.1.1, .1.2 PLEASE | | SEE KNOW THIS WAS NOT IN PREVIOUS REVIEW NOTES, HOWEVER | | PLEASE SUBMIT/INCLUDE ENERGY/PERFORMANCE CALCULATIONS | | FOR LIGHTING ALLOWANCES PER 13-415.1.AB.1, 13-415.2 | | | | 3) NOTE: PLEASE SEE ADDRESS IS STILL MISSING FROM THE | | TITLE BLOCKS ON EACH SHEET. 61G1-16.004/ 61G15-23.002 | | | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-12-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-12-10 |
Time |
08:24 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-12-10 |
Time |
07:34 |
Sent To |
I |
|
Notes |
2006-12-10 08:26:42 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE MISSING COMPLETE INFORMATION FOR A | | TITLE BLOCK FOR THE ARCHITECT OF RECORD. PLEASE SEE | | ATTACHED SHEET FROM DEPARTMENT OF BUSINESS AND | | PROFESSIONAL REGULATION. PLEASE SEE NO ADDRESS | | INFORMATION ETC. | | PLEASE KNOW IF WORKING THROUGH PBM DEVELOPMENT, AND PBM | | IS OFFERING ARCHITECTURAL SERVICES, THEN PBM WOULD BE | | REQUIRED TO LIST THEIR CERTIFICATE OF AUTHORIZATION | | NUMBER. (IF APPLICABLE). | | FLORIDA ADMINISTRATIVE CODE 61G1-16.004, FLORIDA | | STATUTES 481.219 | | **THIS IS NOT A COMMENT RELATED TO KAMM CONSULTING, | | HOWEVER TITLE BLOCKS ARE REQUIRED FOR ALL SHEETS PER | | ABOVE AND WHETHER OR NOT COMMENT IS MADE BY ANY OTHER | | TRADE. | | | | 2) NOTE: PLEASE LIST THE FOLLOWING MINIMUM CODES | | RELEVANT TO THIS PROJECT AND DESIGN. | | 2002 NFPA-72, 2002 NFPA-70, 2003 NFPA-101 | | ** 2004 FBC** | | | | 3) NOTE: PLEASE SEE MISSING LIGHTING CONTROL FOR ALL | | PER 13-415.1.ABC.1.1, .1.2, AND .1.3. PLEASE SEE | | MISSING CONTROLS FOR COMMON AREAS. PLEASE SEE OVER | | RIDES DEVICES FOR THESE AREAS ALSO DEPENDING ON | | "SYSTEM" OR DEVICES CHOSEN. PLEASE SEE THE SYMBOL | | LEGEND FOR ALL DEVICES SHALL INDICATE ALL MAXIMUM TIMES | | FOR DEVICES. (30MINS FOR OCCUPANCY SENSOR TYPE AND 4HRS | | MAX FOR TIMER TYPE) | | PLEASE PROVIDE SCHEDULING FOR ANY PROPOSED SYSTEM. | | PLEASE SEE ALL AREAS CONTAIN FLOOR TO CEILING HEIGHT | | PARTITIONS SHALL CONTAIN DEVICE(S) FOR CONTROL. (PLEASE | | SEE STORAGE) | | PLEASE SEE 13-415.2, 13-415.2.ABC.1 FOR MISSING MAXIMUM | | PERMITTED LIGHTING POWER DENSITIES. | | ** PLEASE SUBMIT THE ABOVE. AS THERE ARE ITEMS NOT YET | | SUBMITTED, A REVIEW OF SAID SYSTEM/DEVICES ETC CAN NOT | | BE FULLY ACCOMPLISHED AT THIS TIME. | | | | 4) NOTE: PLEASE PROVIDE A DETAIL ON ALL EMERGENCY | | AND/OR EXIT LIGHTING WIRED AHEAD OF ANY OVER RIDE | | CONTROL DEVICES PER 700.12E. PLEASE SEE A | | CLOUDED/HIGHLIGHTED NOTE MAY ALSO BE DONE. THIS AHJ HAS | | BEEN HAVING MANY INSTANCES WHERE EMERGENCY AND EXIT | | LIGHTS ARE BEING WIRED ON THE LOAD SIDE OF OC/ TIMER | | DEVICES. | | | | 5) NOTE: PLEASE INDICATE ALL CONTINUOUS LOADS AT 125%. | | 215.3, 230.42 ETC. | | FBC 106.1.2 ADMIN SECTION. | | | | 6) NOTE: PLEASE KNOW EITHER AT THIS POINT OR BEFORE | | FINAL, A REVISION FOR ALL CIRCUITS TO SPECIFIC ROOMS | | AND AREAS WILL BE REQUIRED. (LIGHTING CIRCUITS ETC.) | | 408.4. | | ALL RECEPTACLE CIRCUITS ARE OK AS SHOWN. | | | | 7) NOTE:** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDEDSHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS.PLEASE KNOW ONLY | | ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | | | | 2006-12-10 07:35:20 | REMOVED FROM INCOMING, WILL BEROUTED BACK TO INCOMING | | ONCE REVIEW IS DONE TO WAIT FOR COMMBOB. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2007-04-16 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-04-16 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-04-16 |
Time |
13:21 |
Sent To |
|
|
Notes |
2007-04-16 13:39:18 | *****APPROVED***** | | | | | | PLAN SHEETS LS-01, E2.1, FA2.1 AND FS2.1 WERE STAMPED, | | INITIALED, AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2007-04-04 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-04-04 |
Time |
17:20 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-04-04 |
Time |
17:14 |
Sent To |
|
|
Notes |
2007-04-04 17:19:33 | *****APPROVED***** | | | | | | | | ALL COMMENTS FROM THE 02/06/07 FIRE PLAN REVIEW HAVE | | BEEN ADDRESSED;THE APPROPIATE PLAN SHEET(S) TO BE | | STAMPED WHEN ALL OTHER PLAN REVIEWS HAVE BEEN | | SATISFIED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2007-02-06 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-02-06 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-02-06 |
Time |
10:58 |
Sent To |
|
|
Notes |
2007-02-06 11:01:10 | *****DENIED***** | | | | | | 01.NFPA 101 (2003 EDITION) AND THE FLORIDA FIRE | | PREVENTION CODE (2004 EDITION) SHALL BE REFERENCED. | | | | 02. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 03.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS | | SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT | | OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | 04.THE COMPLETE ADDRESS OF WHERE THE SCOPE OF WORK | | WILL BE CONDUCTED SHALL BE IN THE TITLE BLOCK OF EACH | | SUBMITTED PLAN SHEET. | | | | 05.DISPLAY THE TENANT SPACE NUMBER FOR THIS SITE SO | | THAT IT IS DISTINGUISHABLE FROM OTHER TENANT SITES ON | | THE FLOOR.AS PER WEST PALM BEACH CODE, THOSE NUMBERS | | SHALL BE NO LESS THAN 3" IN HEIGHT. | | | | 06.DOOR(S) LEADING DIRECTLY TO THE FOURTH FLOOR | | CORRIDOR SHALL BE AN APPROVED, LISTED, AND LABELED FIRE | | DOOR & ASSEMBLY IN ACCORDANCE WITH THE REQUIREMENTS OF | | NFPA 80. | | | | 07.WHAT IS INTERIOR FINISH CLASSIFICATION FOR THE | | WALLS AND CEILINGS IN THE EXITS, EXIT ACCESS CORRIDORS, | | AND IN ALL OTHER AREAS? | | | | 08.PROVIDE A LIFE SAFETY PLAN SHEET WHICH INDICATES | | THE TRAVEL DISTANCE TO THE EXIT(S).ALSO ON THIS | | SHEET, INDICATE THE LOCATION OFFIRE EXTINGUISHER(S) | | AT DISTANCES TO SATISFY THE 75' TRAVEL DISTANCE | | REQUIREMENT. | | | | 09.ON SHEET FA0.1, FIRE ALARM NOTE #17 SHOULD BE | | CHANGED TO "INITIATE A GENERAL FIRE ALARM". | | | | 10.PROVIDE A LAYOUT OF THE FIRE SPRINKLER SYSTEM FOR | | THIS TENANT SPACE. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-12-26 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-12-26 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-12-26 |
Time |
10:57 |
Sent To |
|
|
Notes |
2006-12-26 11:23:06 | *****DENIED***** | | | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | 3.DISPLAY THE TENANT SPACE NUMBER FOR THIS SITE SO | | THAT IT IS DISTINGUISHABLE FROM OTHER TENANT SPACES ON | | THE FLOOR.AS PER WEST PALM BEACH CODE, THOSE NUMBERS | | SHALL BE NO LESS THAN 3" IN HEIGHT. | | | | 4.WHAT IS INTERIOR FINISH CLASSIFICATION FOR THE | | WALLS AND CEILINGS IN THE EXITS AND EXIT ACCESS | | CORRIDORS? | | | | 5.ADDRESS BUILDING REVIEW COMMENTS IN REGARDS TO EXIT | | ACCESS ANDMANEUVERING CLEARANCES. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-04-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-23 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-23 |
Time |
10:06 |
Sent To |
E |
|
Notes |
2007-04-23 10:07:02 | TO "BOB"#6 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-04-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-11 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-11 |
Time |
15:11 |
Sent To |
|
|
Notes |
2007-04-11 15:11:28 | TO "BOB"#16 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-04-03 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-04-03 |
Time |
17:30 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-04-03 |
Time |
17:30 |
Sent To |
|
|
Notes |
2007-04-03 17:31:01 | TO BOB # 12 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-03-30 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-03-30 |
Time |
18:46 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-03-30 |
Time |
18:46 |
Sent To |
|
|
Notes |
2007-03-30 18:46:22 | WAITING FOR BOB BOARD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-01-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-24 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-24 |
Time |
16:46 |
Sent To |
|
|
Notes |
2007-01-24 16:51:06 | TO "BOB"#7--NEW SHEETS FOR "M" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-01-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-01-03 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-11-29 |
Time |
18:03 |
Sent To |
|
|
Notes |
2006-12-12 17:24:35 | TO "BOB"#7 | 2006-11-29 18:03:47 | WAITING FOR "BOB" BOARD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2007-04-24 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-04-24 |
Time |
10:45 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2007-04-24 |
Time |
10:45 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2007-04-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-04-04 |
Time |
13:58 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-04-04 |
Time |
13:57 |
Sent To |
|
|
Notes |
2007-04-04 14:08:33 | *** DENIED *** | | 1) SEE ELECTRICAL REVIEW NOTE #3 REGARDING MISSING FIRM | | LICENSE NUMBER FOR PBM DEVELOPMENT FROM TITLE BLOCK, | | SEE FAC 61G1-16.004, PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-02-02 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-02-02 |
Time |
11:12 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-02-02 |
Time |
11:12 |
Sent To |
|
|
Notes |
2007-02-02 11:14:20 | *** DENIED *** | | 1) SEE ELECTRICAL REVIEW NOTES 1 AND 3, PLEASE | | CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-02-02 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-12-14 |
Time |
08:43 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-12-14 |
Time |
08:43 |
Sent To |
|
|
Notes |
2006-12-14 08:45:44 | 2-2-07 .SEE ELECTRICAL REVIEW 1-25-07NOTES 1 AND | | 3. | | | | NOTE:ONE SET OF MECHANICAL PLANS COULD NOT BE STAMPED | | AS IT IS MISSING PAGE M0.1. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-04-04 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-04-04 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-04-04 |
Time |
07:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-02-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-02-03 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-02-03 |
Time |
09:21 |
Sent To |
|
|
Notes |
2007-02-03 09:33:14 | DENIED; | | 1. SEE ELECTRICAL NOTES # 1 AND # 3. | | 2. A/C DRAWING PAGE M2.1 SHOWS THE RETURN AIR IS NOT | | DUCTED, SO AREA ABOVE DROPPED CEILING IS A PLENUM. | | PLEASE REVISE NOTE # 11 ON PLUMBINGNOTES , PAGE | | P0.1, TO READ NO PVC TO BE USED. | | 3. LAST REVIEW #5WAS NOT ADDRESSED. WATER HAMMER | | ARRESTORS TO BE INSTALLED PER MANUFACTURE'S | | INSTALLATION INSTRUCTIONS, AS CLOSED TO THE SOURCE, | | (FIXTURE) AS POSSIBLE. ONE WATER RISER DIAGRAM MARKED | | IN RED. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2007-02-03 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-01-03 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-01-03 |
Time |
09:49 |
Sent To |
|
|
Notes |
2007-01-03 10:02:27 | DENIED; | | 1.PLEASE SHOW HANDICAP CLEAR FLOOR SPACE ON FLOOR PLAN | | FOR BREAK SINK AND LAVATORY, AND THE TURNING RADIUS IN | | BATHROOM. | | 2.SHOW A DETAIL OF BREAK SINK WITH ALL MEASUREMENT | | REQUIRED TO MEET H/C REQUIREMENTS SEE FBC-2004 CHAPTER | | 11 SEC. 11-4.24.2 THRU 11-4.24.7. | | 3.SHOWA DETAIL OF BATHROOM WITH ALL REQUIRED | | MEASUREMENTS W/C SEC11-4.16.2 THRU 11-4.16.7 AND | | LAVATORY 11-4.19.2 THRU 11-4.19.6. | | 4.BATHROOM DOOR TO SWING OUT. CANNOT SWING INTO CLEAR | | FLOOR SPACE OF LAV. | | 5. WATER HAMMER ARRESTORS ARE TO BE INSTALLED PER | | FBC-2004 PLUMBING SECTION 604.9 AND MANUFACTURER'S | | SPECIFICATIONS, AS CLOSE TO THE SOURCE. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|