Plan Review Details - Permit 06110718
Plan Review Stops For Permit 06110718
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-02-02 Cont ID  
Sent By rmcdouga Date 2007-02-02 Time 07:02 Rev Time 0.00
Received By rmcdouga Date 2007-02-02 Time 06:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-01-17 Cont ID  
Sent By rmcdouga Date 2007-01-17 Time 06:59 Rev Time 0.00
Received By rmcdouga Date 2007-01-17 Time 06:38 Sent To  
Notes
2007-01-17 06:59:05DENIED BY BUILDING
  
 1) SPECIFY THE TYPE OF FASTENER AND THE AMOUNT REQUIRED
 TO ATTACH THE LARGE ENTRANCE AWNING TO THE CONCRETE
 FOOTERS. SPECIFY WHAT THE MINIMUM REQUIREMENT FOR THE
 FOOTER OR SLAB TO WHICH IT WILL BE ANCHORED.
  
 2) SPECIFY THE NUMBER AND LENGTH/EMBED DEPTH OF THE LAG
 BOLTS USED TO ATTACH THE WINDOW AWNINGS TO THE
 BUILDING. SPECIFY THE TYPE OF STRUCTURAL SUBSTRATE TO
 WHICH THEY WILL BE ANCHORED.
  
 3)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-02-01 Cont ID  
Sent By adarroug Date 2007-02-01 Time 08:13 Rev Time 0.00
Received By adarroug Date 2007-02-01 Time 08:13 Sent To B
Notes
2007-02-01 08:13:41TO "RMCDOUGAL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-01-29 Cont ID  
Sent By adarroug Date 2007-01-29 Time 11:49 Rev Time 0.00
Received By adarroug Date 2007-01-29 Time 11:49 Sent To Z
Notes
2007-01-29 11:49:27TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-01-17 Cont ID  
Sent By rmcdouga Date 2007-01-17 Time 06:59 Rev Time 0.00
Received By rmcdouga Date 2006-12-07 Time 09:48 Sent To  
Notes
2006-12-07 09:49:05TO "MISC" BOX#2

Review Stop Z ZONING
Rev No 2 Status N Date 2007-01-31 Cont ID  
Sent By eschneid Date 2007-01-31 Time 17:19 Rev Time 0.00
Received By eschneid Date 2007-01-31 Time 17:18 Sent To  
Notes
2007-01-31 17:19:29REVISION NOT MATERIAL TO ZONING APPROVAL.

Review Stop Z ZONING
Rev No 1 Status P Date 2006-12-06 Cont ID  
Sent By eschneid Date 2006-12-06 Time 18:10 Rev Time 0.00
Received By eschneid Date 2006-12-06 Time 18:10 Sent To I
Notes
2006-11-29 17:37:00SENT TO ZONING


Account Summary | Usage Policy | Privacy Policy