Plan Review Stops For Permit 06110393 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-01-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-01-30 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-01-30 |
Time |
12:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2007-01-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-01-08 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-01-08 |
Time |
11:18 |
Sent To |
|
|
Notes |
2007-01-08 11:27:50 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | FBC2004 | | | | 1.)THE PLANS PREPARED BY THE LANDSCAPE ARCHITECT ARE | | TO BE SIGNED, SEALED, AND DATED FS481.306 WHEN | | SUBMITTED FOR PUBLIC RECORD.THEY ARE MARKED "FOR | | REFERENCE ONLY" BUT THIS DOES NOT EXEMPT A STATUTORY | | REQUIREMENT. | | | | 2.)THE TYPICAL HANDICAP SIGN IS NOT COMPLIANT WITH | | FBC11-4.6.4 (KILDAY & ASSOC PLAN). | | | | 3.)THE TYPE III CONCRETE POLE DETAIL STATES THAT IT | | WILL COMPLY WITH 120 MPH WIND CRITERIA, NOT CLEAR IF | | THIS IS SUSTAINED OR 3 SECOND GUST.(KILDAY & ASSOC | | PLAN). | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-01-26 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-01-26 |
Time |
09:12 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2007-01-26 |
Time |
07:42 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-11-30 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-11-30 |
Time |
12:56 |
Rev Time |
0.75 |
Received By |
btrobaug |
Date |
2006-11-30 |
Time |
12:38 |
Sent To |
B |
|
Notes |
2006-11-30 12:56:28 | | | | | NONCOMPLIANT | | | | THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK MUST | | SIGN THE DOCUMENT. 61G15-23.002 FAC. | | | | | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-01-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-23 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-23 |
Time |
13:01 |
Sent To |
E |
|
Notes |
2007-01-23 13:01:52 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-01-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-18 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-18 |
Time |
11:35 |
Sent To |
Z |
|
Notes |
2007-01-18 11:36:22 | TO "Z" BOX/RESUB--NEW SHEETS FOR "Z" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2007-01-08 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-01-08 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-11-14 |
Time |
13:46 |
Sent To |
|
|
Notes |
2006-11-14 13:47:39 | TO "E" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-01-23 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2007-01-23 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2007-01-23 |
Time |
12:26 |
Sent To |
I |
|
Notes |
2007-01-23 12:27:02 | PASSED W/PROVISO | | | | PROVISO - IF GLARE ONTO OKEECHOBEE IS IDENTIFIED AS A | | PROBLEM AFTER INSTALLATION, ADDITIONAL SHIELDING WILL | | BE REQUIRED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2006-12-08 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2006-12-08 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2006-12-08 |
Time |
15:12 |
Sent To |
I |
|
Notes |
2006-12-08 15:15:20 | PASSED W/PROVISO | | | | PROVISO - IF GLARE ONTO OKEECHOBEE IS IDENTIFIED AS A | | PROBLEM AFTER INSTALLATION, ADDITIONAL SHIELDING WILL | | BE REQUIRED. |
|
|