Plan Review Details - Permit 06101150
Plan Review Stops For Permit 06101150
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-11-29 Cont ID  
Sent By alange Date 2006-11-29 Time 10:47 Rev Time 0.00
Received By alange Date 2006-11-29 Time 10:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-11-09 Cont ID  
Sent By btrobaug Date 2006-11-09 Time 10:46 Rev Time 0.33
Received By btrobaug Date 2006-11-09 Time 10:37 Sent To M
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2007-01-03 Cont ID  
Sent By mperson Date 2007-01-03 Time 13:23 Rev Time 0.33
Received By mperson Date 2007-01-03 Time 13:23 Sent To M
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2006-11-28 Cont ID  
Sent By mperson Date 2006-11-28 Time 08:02 Rev Time 0.33
Received By mperson Date 2006-11-28 Time 08:02 Sent To B
Notes
2006-11-28 09:09:37UNSAT
 REFERENCE: FBC-2004 FUEL GAS
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR GAS PLAN
 REVIEW TO MEET CODE COMPLIANCE:
  
 1. A GAS PERMIT CAN NOT BE ISSUED UNTIL
 A GEN/RES PERMIT APPLICATION HAS BEEN
 APPROVED BY ZONING FOR
 THE GENERATOR LOCATION.
 NOTE: PLEASE BE AWARE THAT IF GENERATOR LOCATION
 CHANGES BECAUSE OF ZONING ISSUES THE GAS DRAWING MUST
 CORRELATE WITH THESE CHANGES.
  
 2. PLEASE PROVIDE MANUFACTURER INSTALLATION
 INSTRUCTIONS OF GENERATOR REGAURDING CLEARENCES TO
 STRUCTURES.
  
 3. PLEASE PROVIDE A CURRENT SURVEY (2 COPIES) WITH
 DIMENSIONS OF PROPOSED GENERATOR TO STRUCTURES AND
 PROPERTY LINES.
  
 4. PLEASE INDICATE THE TYPE OF GAS, (LP OR NATURAL) ON
 THE GAS ISOMETRIC DRAWINGS.
  
 5. PLEASE BE AWARE THAT IF THE GAS SYSTEM IS NATURAL
 GAS FOR THE PROPOSED GENERATOR THAT THE BTU LOAD
 INDICATED ON THE GAS ISOMETRIC DRAWING IS WRONG, IT
 SHOULD BE 723,000 NOT 698,000 PER THE SUBMITTED
 MANUFACTURER SPECIFICATIONS. PLEASE CORRECT FOR THE
 RESUBMITTAL.
  
 6. NOTE: PLEASE BE AWARE THAT A GAS PERMIT IS REQUIRED
 FOR THE PROPOSED GENERATOR AND THAT THERE WAS NOT A GAS
 CONTRACTOR SIGNED ON THE GEN/RES PERMIT APPLICATION
 EVEN THOUGH THERE WAS A GAS ISOMETRIC DRAWING
 SUBMITTED. PLEASE CLARIFY THIS ON THE RESUBMITTAL.
  
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-12-26 Cont ID  
Sent By adarroug Date 2006-12-26 Time 16:43 Rev Time 0.00
Received By adarroug Date 2006-12-26 Time 16:43 Sent To P
Notes
2006-12-26 16:43:44TO "G" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-12-20 Cont ID  
Sent By adarroug Date 2006-12-20 Time 11:10 Rev Time 0.00
Received By adarroug Date 2006-12-20 Time 11:10 Sent To Z
Notes
2006-12-20 11:10:42TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-08 Cont ID  
Sent By adarroug Date 2006-11-08 Time 13:57 Rev Time 0.00
Received By adarroug Date 2006-11-08 Time 13:57 Sent To E
Notes
2006-11-08 13:58:11TO "GEN-RES""E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-11-29 Cont ID  
Sent By alange Date 2006-11-29 Time 10:47 Rev Time 0.00
Received By alange Date 2006-11-02 Time 10:44 Sent To  
Notes
2006-11-02 10:44:51TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-01-03 Cont ID  
Sent By tgordon Date 2007-01-03 Time 14:07 Rev Time 0.30
Received By tgordon Date 2007-01-03 Time 14:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-11-09 Cont ID  
Sent By tgordon Date 2006-11-09 Time 11:05 Rev Time 0.25
Received By tgordon Date 2006-11-09 Time 11:05 Sent To G
Notes
2006-11-09 11:11:44*** DENIED ***
 1) PLEASE SUBMIT DETAILED MANUFACTURE'S SPECIFICATION'S
 AND INSTALLATION
 INSTRUCTIONS FOR GENERATOR.
  
 2) SEE ZONING REVIEW NOTES, PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop Z ZONING
Rev No 2 Status P Date 2006-12-26 Cont ID  
Sent By mmclean Date 2006-12-26 Time 14:55 Rev Time 0.00
Received By mmclean Date 2006-12-26 Time 14:55 Sent To I
Notes
2006-12-26 14:56:45NOTE: THE PROPOSED GENERATOR SHALL BE NO CLOSER THAN
 5FT FROM THE SIDE PROPERTY LINE AND 14FT FROM THE REAR
 PROPERTY LINE.GENERATOR CAN PROJECTOR NO MORE THAN
 4FT INTO A REQUIRED SETBACK.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-11-06 Cont ID  
Sent By mmclean Date 2006-11-06 Time 15:21 Rev Time 0.00
Received By mmclean Date 2006-11-06 Time 15:21 Sent To I
Notes
2006-11-07 15:25:39DENIED,
 1. THE SUBMITTED SURVEY IS BEYOND THE 1 YEAR
 REQUIREMENT FOR SURVEYS TO BE USED FOR REVIEW OF A
 PROPOSED WORK. SURVEY SUBMITTED IS 1955
 2. PLEASE SUBMIT 2 COPIES OF CURRENT SURVEYS SHOWING
 THE LOT DIMENSION, SETBACKS OF STRUCTURE (CLEARLY) WITH
 THE PROPOSED WORK.
  
 NOTE: SEC 94-303 MECHANICAL/POOL EQUIPMENT/GENERATOR
 MAY NOT PROJECT MORE THAN FOUR FEET INTO A SETBACK.
  
 3. THE PROPOSED GENERATOR SHALL NOT BE CLOSER THAN
 5.4FT FROM REAR PROPERTY LINE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  