Plan Review Stops For Permit 06101031 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2007-03-06 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-03-06 |
Time |
17:06 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-03-06 |
Time |
17:06 |
Sent To |
PC |
|
Notes |
2007-03-06 17:07:47 | ENGINEERING FOR LIGHT POLES. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2007-02-26 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-02-26 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-02-24 |
Time |
14:00 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2007-02-13 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-02-13 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-02-13 |
Time |
07:43 |
Sent To |
PC |
|
Notes |
2007-02-13 09:39:49 | BUILDING PLAN REVIEW | | PERMIT: 06101031 | | ADD:2501 N.FLAGLER DR. | | CONT:G.A. RAY INC. | | TEL: (561)630-4861 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2)F.A.C. 61G15-23.002A COVER OR INDEX SHEET FOR | | ENGINEERING SPECIFICATIONS MAY BE USED AND THAT SHEET | | MUST BE SIGNED, SEALED AND DATED BY THE ENGINEER IN | | RESPONSIBLE CHARGE OF THE PRODUCTION AND PREPARATION OF | | EACH SECTION OF THE ENGINEERING SPECIFICATION WITH | | SUFFICIENT INFORMATION ON THE COVER SHEET OR INDEX SO | | THAT THE WILL BE AWARE OF EACH PORTION OF THE | | SPECIFICATIONS FOR WHICH EACH PROFESSIONAL ENGINEER IS | | RESPONSIBLE. (INDICATE EACH PAGE ON THE COVER OR INDEX | | SHEET) | | | | 3) THE ASCE REFERENCE STANDARD (ASCE 7-04) STATED IN | | THE ENGINEERING REPORT FOR THE LIGHT POLE IS INCORRECT. | | SEE FBC. 35.6R FOR MORE INFORMATION. | | | | 4)2004 FL. BLD CODE 1603.1.4 THE | | FOLLOWING INFORMATION RELATED TO WIND | | SHALL BE SHOWN ON THE CONSTRUCTION | | DRAWINGS, | | 1)- BASIC WIND SPEED, MPH | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | CATEGORY | | 3)- WIND EXPOSURE | | 4)- INTERNAL PRESSURE COEFFICIENT, | | 5)- COMPONENTS & CLADDING, THE DESIGN | | WIND PRESSURES IN TERMS OF PSF. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-01-23 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-01-23 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-01-23 |
Time |
06:38 |
Sent To |
|
|
Notes |
2007-01-23 10:50:25 | BUILDING PLAN REVIEW | | PERMIT: 0610 | | ADD: | | CONT: | | TEL: (561)###-#### | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2)CLARIFY THE TOTAL NUMBER OF PARKING SPACES | | AVAILABLE. THE SPACES ON THE DRAWINGS DOES NOT MATCH | | THE NUMBER INDICATED ON SHEET A-1.00. | | | | 3)FBC 11-4.6.3 PARKING ACCESS AISLES MUST BE NO LESS | | THAN 5 FEET WIDE AND MUST BE PART OF AN ACCESSIBLE | | ROUTE TO THE BUILDING OR FACILITY ENTRACE. TWO | | ACCESSIBLE SPACES MAY SHARE A COMMON ACCESS AISLE {SEE | | FIG 9(A)}. THE ACCESS AISLE SHALL BE STRIPED DIAGONALLY | | TO DESIGNATE IT AS A NO-PARKING ZONE. CURB RAMPS MUST | | BE LOCATED OUTSIDE OF THE DISABLED PARKING SPACES AND | | ACCESS AISLES. | | | | 4)WPB AMENDMENTS. 106.1.3THE BUILDING OFFICIAL MAY | | ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR | | PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE | | CONFORMITY TO ITS RECORD AND RETENTION PROGRAM. THIS | | POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIXE, SHAPE, | | CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | MANAGEMENT. SOME OF THE PRODUCT APPROVALS SUBMITTED ARE | | ILLEGIBLE. SEE PRODUCT #S 05-0902.01 AND 05-1012.04. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-01-08 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-01-08 |
Time |
|
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-01-08 |
Time |
07:30 |
Sent To |
|
|
Notes |
2007-01-08 09:57:26 | BUILDING PLAN REVIEW | | PERMIT:06101031 | | ADD: 2501 N. FLAGLER DR. | | CONT: G.A. RAY INC. | | TEL: (561)630-4861 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 1ST. | | ACTION: DENIED | | | | | | 1) FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT BEFORE A | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | NOT ACTUALLY COMMENCED | | WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | 2)PROVIDE A DEMO FLOOR PLAN SHOW THE EXISTING AND | | PROPOSED PLAN. SUBMIT A LEGEND SHOWING WHICH WALLS | | WILL BE REMOVED. | | | | 3)A DETAIL DRAWING OF THE DRYWALL CEILING IS REQUIRED | | SHOWING ALL MATERIALS WIHIC WILL BE USED TO HOLD THE | | DRYWALL CEILINGS IN PLACE. WPB. AMEND.106.1.2 | | ADDITIONAL DATA. THE | | BUILDING OFFICIAL MAY REQUIRE DETAILS, COMPUTATIONS, | | STRESS DIAGRAMS, AND OTHER | | DATA NECESSARY TO DESCRIBE THE | | CONSTRUCTION OR INSTALLATION AND THE | | BASIS OF CALCULATION. ALL DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA | | REQUIRED BY THE BUILDING OFFICIAL TO BE | | PREPARED BY AN ARCHITECT OR ENGINEER | | SHALL BE AFFIXED WITH THIER OFFICIAL | | SEAL, SIGNATURE AND DATE AS STATE LAW | | REQUIRES. | | | | 4) INDICATE THE CLEAR FLOOR SPACE ON THE DRAWINGS FOR | | THE LAVATORIES AND WATER CLOSETS. SEE SECTIONS 11-4.19 | | AND 11-4.16. | | | | 5)ON THE PRODUCT APPROVAL FOR THE SHUTTERS HI-LIGHT | | OR CIRCLE THE ITEMS WHICH WILL BE USED. THE ANCHOR | | SCHEDULE SHALL ALSO BE HI-LIGHED OR CIRCLE INDICATING | | THE TYPE OF FASTENERS TO BE USED. NOTE: A SHUTTER | | SCHEDULE IS IN THE PACKAGE. EITHER FILL IT OUR OR | | PROVIDE A SIMILAR SCHEDULE WITH ALL REQUIRED | | INFORMATION. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-11-07 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-11-07 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-11-07 |
Time |
09:56 |
Sent To |
|
|
Notes |
2006-11-07 10:25:57 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY COURTHOUSE AND A COPY | | SUBMITTED TO THIS OFFICE BEFORE A PERMIT CAN BE ISSUED. | | BLANK FORMS ARE AVAILABLE FROM THIS OFFICE. | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF | | THE DESCRIBED IMPROVEMENT OR CONSTRUCTION IS NOT | | COMMENCED WITHIN 90 DAYS OF RECORDING. | | | | 2.SUBMIT A LIFE SAFTEY PLAN. | | | | 3. SHOW AN ELEVATION OF THE RECEPTION COUNTER AND | | SHOW COMPLIANCE WITH FBC 11-7. | | | | 4.ALL PRODUCT APPROVALS SUBMITTED WITH QUALITY | | ASSURANCE SHALL HAVE THE FOLLOWING STATE APPROVAL | | ATTACHED. | | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT | | LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF | | THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN | | APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC | | FORM PER RULE 9B-72. SEE ATTACHMENT. | | WWW.FLORIDABUILDING.ORG | | | | 5.THOSE PRODUCT APPROVALS WHICH ARE REGULATED BY DCA | | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL.WPB AMENDMENT TO FBC 106.3.3. | | | | | | 6.A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR | | A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | SECTIONS 303, 304 AND 305 OF THIS CODE.SHOW HOW PLANS | | WILL COMPLY WITH THE SECTION(S) SELECTED.2004 FBC | | EXISTING BUILDING 301.5 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE | | COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET | | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | | | | | ART LANGE | | BUILDING PLANS EXAMINER | | CONSTRUCTION SERVICES DEPARTMENT | | 561-805-6672 | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2007-02-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-02-18 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-02-18 |
Time |
15:50 |
Sent To |
|
|
Notes |
2007-02-18 15:51:27 | REDLINED OLD LS PLANS TO SE REVISED LIGHTING ON E-1 AND | | NEW LS SHEETS. | | STAMPED ELECTRICAL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2007-02-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-02-11 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-02-11 |
Time |
12:29 |
Sent To |
|
|
Notes |
2007-02-11 13:34:16 | *** UNSAT 4TH REVIEW*** | | | | ** PLEASE SEE NOTES FROM PREVIOUS REVIEWS WHICH STILL | | NEED TO BE ADDRESSED ALONG WITH NEW NOTES AS STATED | | BELOW. | | | | | | 1) NOTE: PLEASE SEE IN ALL PREVIOUS REVIEWS IT WAS | | REQUESTED THAT ALL OLD/VOIDED SHEETS BE REMOVED FROM | | SETS AND TO INSERT NEW REVISED SHEETS INTO SETS, PLEASE | | INSERT NEW SHEETS AND ATTACH INTO SETS. PLEASE DO NOT | | ONLY INSERT SHEET LOOSELY INTO SETS. | | THIS WILL HELP IN PROCESSING THE PLANS FOR PERMITTING. | | | | 2) NOTE: PLEASE SEE THE ORIGINAL REVIEW REQUESTED | | ENERGY CALCULATIONS AND PERFORMANCE CALCULATIONS WHICH | | MET THE 2004 FBC AND CHAPTER 13. THESE WERE SUBMITTED | | FOR REVIEW FOR THE 2ND REVIEW AND 3RD REVIEW WHICH | | NOTES REQUESTED FOR COMPLIANCE AND FOR ALL CALCULATIONS | | TO CORRELATE WITH THE PLANS SUBMITTED AND THERE WERE | | SUBSTANTIAL DIFFERENCES IN THE NUMBER OF FIXTURES, | | LOADS, WATTAGE(S), ETC. | | PLEASE SEE THAT THIS COMMENT IS STILL BEING MADE AS THE | | ENERGY CALCULATIONS DO NOT CORRELATE WITH PLANS OR | | FIXTURE LEGEND FOR FIXTURES, NUMBER OF FIXTURES, | | WATTAGES OF FIXTURES ETC. | | PLEASE SEE THERE ARE SEVERAL ITEMS WHICH DO NOT MATCH. | | PLEASE SEE OUTSIDE/EXTERIOR FIXTURES, PLEASE SEE | | INTERIOR FIXTURES ETC | | PLEASE SEE ALL. | | THE TOTALS DO NOT CORRELATE, TOTALS ON SOME OF THE | | FIXTURES ON FIXTURE LEGEND DOES NOT MATCH WITH PLANS | | AND # OF FIXTURES AS SHOWN. ETC. | | THIS WAS STATED IN ALL REVIEWS AFTER THE 1ST REVIEW AS | | THESE WERE SUBMITTED ON THE FIRST REVIEW WHICH WAS | | STILL REQUIRED UNDER THE 2004 FBC. | | PLEASE SEE THAT A METHOD A IS STILL BEING SHOWN, | | HOWEVER IT IS NOT CLEAR HOW THIS IS BEING USED WHEN | | THIS IS FOR TOTAL BUILDING COMPLIANCE AND OTHER AREAS | | AND TRADES OFFS ARE NOT BEING SHOWN OR INDICATED. | | (PREVIOUS REVIEWS). | | PLEASE SEE THE ELECTRICAL PLANS FOR FIXTURES WERE | | REVISED TO DELETE MANY FIXTURES HOWEVER THE | | ARCHITECTURAL AND LIFE SAFETY SHEETS WERE NOT REVISED | | TO REFLECT THESE CHANGES. | | PLEASE SEE FBC 2004 13-415.1.AB.1. | | PLEASE SEE 13-415.2. | | | | 3) NOTE: PLEASE SEE THE WIND LOADS SEEMS TO BE OK, | | HOWEVER WILL BE REVIEWED BY THE STRUCTURAL REVIEWER. | | PLEASE SEE THE ELECTRICAL SHEETS STILL NOT INDICATE ANY | | REFERENCE TO THE 140MPH WIND LOAD REQUESTED ON PREVIOUS | | REVIEW. | | | | ** NEW NOTES DUE TO PLANS SUBMITTED AND CHANGES WHICH | | WERE NOT ON PREVIOUS PLANS. | | | | 3) NOTE: PLEASE SEE RISER NOW SHOWS *EQUIPMENT | | GROUNDING CONDUCTORS FROM THE GUTTER TO THE FIRST MEANS | | OF DISCONNECT IS NOT PERMITTED PER 250.6. | | PLEASE SEE THE PREVIOUS COMMENTS REQUESTED TO SHOW THE | | CONDUCTORS FROM THE GUTTER TO EACH MAIN AND FOR * | | EQUIPMENT GROUNDING CONDUCTORS* AFTER THE FIRST MEANS | | OF DISCONNECT. | | PLEASE SEE 250.6 AND 250.24B AS THIS NOW CREATES | | OBJECTIONABLE CURRENTS BY PARALLELING THE NEUTRAL. | | PLEASE SEE THIS WOULD HAVE BEEN REDLINED, HOWEVER AS | | PLANS ARE COMING BACK FOR COMMENT #2, PLEASE CORRECT AT | | THIS TIME. | | | | 4) NOTE: PLEASE SEE AS COMMENT #2 HAS BEEN REPEATED FOR | | CODE COMPLIANCE REVIEW THREE OR MORE TIMES FOR THE SAME | | CODE COMPLIANT COMMENT AND IT IS NECESSARY FOR THIS | | OFFICE TO REJECT PLANS FOR THIS, THE FS 553.80(2)(B) IS | | IN EFFECT AND A 4X FEE FOR THE PLAN REVIEW PORTION OF | | THE PERMIT FEE HAS NOW BEEN ASSESSED. | | THIS FEE IS A REQUIRED FEE PER THE FLORIDA STATUTES TO | | THE DESIGNER(S) OF RECORD AND MUST BE PAID BEFORE PLANS | | CAN BE RESUBMITTED FOR REVIEW. | | PLEASE SEE THAT ONE SET OF EACH ELECTRICAL PLAN AND | | ENERGY CALCULATIONS ARE BEING RETAINED BY THIS OFFICE. | | ONE SET OF THE ARCHITECTURAL AND LS PLANS MAY ALSO BE | | RETAINED. | | THE AMOUNT OF $1620 WILL BE DUE BEFORE PLANS CAN BE | | RESUBMITTED. | | | | ** IT IS RECOMMENDED THAT COMMENT #2 BE REVIEWED AND | | GONE THROUGH THOROUGHLY. | | | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2007-01-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-01-21 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-01-21 |
Time |
12:11 |
Sent To |
|
|
Notes |
2007-01-21 12:50:23 | ** UNSAT 3RD REVIEW ** | | | | | | ** PLEASE SEE SOME COMMENTS FROM THE PREVIOUS REVIEW | | ARE STILL IN NEED OF ADDRESSING ALONG WITH NEW COMMENTS | | BASED ON A COMPLETELY NEW ELECTRICAL RISER DIAGRAM | | BEING SUBMITTED. | | | | | | 1) NOTE: PLEASE SEE THE PLANS NOW HAVE THE SITE | | LIGHTING FIXTURES AND CIRCUITS REMOVED WHEN BOTH THE | | PREVIOUS REVIEWS INDICATED THESE. PLEASE SEE ENERGY | | CALCULATIONS ARE STILL INDICATING THESE TO BE | | INSTALLED. | | PLEASE SEE THAT PLANS MUST SHOW THESE, POLE DETAIL, | | CIRCUITS, AND APPROPRIATE WIND LOADS. | | PLEASE KNOW ANY SHOP PLANS FOR THE POLES MAY BE | | SUBMITTED AT A LATER DATE AS A *PROVISO*; HOWEVER THE | | BASE INFORMATION ABOVE MUST BE SHOWN. (IF THESE ARE | | GOING TO BE DONE)?? | | FBC 106.1.2, 106.3.5.1.2 | | 408.4, 310.16, 240.4 ETC. | | THIS WAS A COMMENT ON PREVIOUS REVIEW. | | | | 2) NOTE: PLEASE SEE PREVIOUS NOTE MENTIONED THAT THE | | ENERGY CALCULATIONS DID NOT CORRELATE WITH THE | | ELECTRICAL FIXTURES AND LIGHTING AS SHOWN ON PLANS. | | THIS IS STILL THE CASE. PLEASE SEE THE AMOUNT AND TYPE | | OF FIXTURES AS SHOWN ON PLANS FAR EXCEED THAT OF ENERGY | | CALCULATIONS. | | PLEASE SEE 13-415.1.AB.1.1. | | PLEASE SEE CHAPTER 13, ALL, AS COMPLIANCE MUST BE MET | | FOR ALL AREAS. 106.1.2, 106.3.5.1.2 | | THIS WAS THE SAME COMMENT ON PREVIOUS REVIEW. | | ** PLEASE KNOW AS THE COMMENT IS BEING REPEATED AND | | COMPLIANCE IS NOT BEING MET, PLEASE SUBMIT A COMPLETE | | FIXTURE LEGEND AND CORRELATE WITH ALL FIXTURE | | DESIGNATIONS ON PLANS. | | 106.1.2, 106.3.5.1.2 | | | | 3) NOTE: PLEASE SEE 220.12, 220 AS STATED ON THE | | PREVIOUS REVIEW FOR TRACK LIGHTING LOADS AND HOW AND | | WHERE THESE ARE BEING FIGURED INTO CALCULATIONS. | | | | 4) NOTE: PLEASE SEE RISER HAS BEEN COMPLETELY REVISED. | | PLEASE INCLUDE MISSING CONDUCTOR FROM METER TO GUTTER | | AND FROM GUTTER TO EACH OF THE NEW MAIN DISCONNECTS AS | | NOW SHOWN. | | 240.4, 310.16, ETC. | | FBC 106.1.2 AND 106.3.5.1.2 ADMIN SECTIONS. | | | | 5) NOTE: PLEASE SEE MISSING EQUIPMENT GROUNDING | | CONDUCTORS FROM NEW MAINS TO PANELS. PLEASE KNOW EVEN | | AS THE USE OF EMT IS BEING SHOWN, UNLESS THE NEW LISTED | | CONNECTORS RATED FOR *EQUIPMENT GROUNDING * IS BEING | | USED AND EQUIPMENT GROUNDING CONDUCTOR SIZED PER | | 250.122 SHALL BE INSTALLED. | | *THIS WOULD HAVE BEEN REDLINED IF THIS WERE THE ONLY | | COMMENT. | | | | 6) NOTE: PLEASE SEE AS THE RISER IS NOW SHOWING A NEW | | PANEL *B*, THE PLANS DO NOT INCLUDE THIS? PLEASE SHOW | | THE LOCATION OF THE NEW PANEL WHICH IS NOW ADDED. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2007-01-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-01-05 |
Time |
20:28 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-01-05 |
Time |
19:21 |
Sent To |
|
|
Notes |
2007-01-05 20:28:58 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE CORRELATE ELECTRICAL AND BUILDING | | PLANS. | | PLEASE SEE THE OFFICE SPACES IN THE ARCHITECTURAL | | SHEETS ARE BEING SHOWN NOT IN SCOPE OF WORK; HOWEVER | | THE ELECTRICAL SHEETS CLEARLY ARE INCLUDING THE | | ELECTRICAL AS REQUIRED IN SCOPE. | | PLEASE COMPLETE AND SEE THE FOLLOWING COMMENT. | | FBC 106.1.2 AND 106.3.5.1.2 FOR ADDITIONAL INFORMATION | | NEEDED. | | | | 2) NOTE: PLEASE SEE THE FBC 2004 METHOD A ENERGY | | CALCULATIONS DO NOT CORRELATE WITH THE SAME SQUARE | | FOOTAGE ON THE PLANS AND ON APPLICATION. | | PLEASE SEE THE ENERGY CALCULATIONS INDICATE ONLY 20, | | 40W LIGHT FIXTURES AND THE ELECTRICAL PLANS SHOW | | LIGHTING FIXTURES IN EXCESS OF WELL OVER 150+ | | FIXTURES. | | PLEASE PROVIDE COMPLETED ENERGY CALCULATIONS WHICH | | CORRELATE WITH THE ELECTRICAL PLANS FOR ALL LIGHTING | | AND ENERGY USAGE. | | PLEASE SEE FBC 13-415.1.AB.1 | | | | 3) NOTE: PLEASE SEE 220.12 FOR LOADS ON TRACK LIGHTING | | TO BE SHOWN. | | | | 4) NOTE: PLEASE SEE THE NOTE ADDED FOR WIND LOADS FOR | | LIGHT POLES IS NOT ENOUGH AND MAKES NO MENTION OF EVEN | | THE WIND LOAD RATINGS ETC. PLEASE SEE THE PREVIOUS | | REVIEW NOTE. | | | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-11-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-11-03 |
Time |
18:49 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-11-03 |
Time |
18:03 |
Sent To |
|
|
Notes |
2006-11-03 18:49:48 | ** UNSAT *** | | | | 1) NOTE: PLEASE PROVIDE SIGNED, DATED AND SEALED WIND | | LOAD CALCULATIONS FOR THE NEW PROPOSED SITE LIGHTING | | POLES. PLEASE BE SURE THE CALCULATIONS INCLUDE THE EPA | | FOR THE LIGHTING FIXTURES WHICH WILL BE INSTALLED. | | PLEASE SEE BLDG REVIEW COMMENTS FOR 140MPH 3 SECOND | | GUST, 120SUSTAINED. ETC | | | | 2) NOTE: PLEASE INCLUDE THE FOLLOWING RELEVANT CODES ON | | PLANS AND DESIGN. | | 2002 NFPA-70 (NEC), 2003 NFPA-101, 2002 NFPA-72 (WHEN | | APPLICABLE). | | | | 3) NOTE: PLEASE SEE ELECTRICAL PANEL IS NOT PERMITTED | | IN OFFICE / STORAGE AREA. PLEASE SEE 240.24D, 408.7, | | 110.26 ETC. | | PLEASE RELOCATE. | | | | 4) NOTE: PLEASE SEE 250.6 AND 250.24 AS AN "EQUIPMENT | | GROUNDING CONDUCTOR" IS BEING INDICATED AHEADOF THE | | MAIN DISCONNECT. | | PLEASE KNOW, THIS SHALL ONLY BE INSTALLED AFTER THE | | FIRST MEANS OF DISCONNECT. | | | | 5) NOTE: PLEASE CORRELATE THE EQUIPMENT GROUNDING | | CONDUCTOR ON RISER WITH THAT LISTED ON PANEL SCHEDULE. | | PLEASE SEE 250.122, | | FBC 106.1.2 | | | | 6) NOTE: PLEASE SEE MISSING CWP AS PART OF THE | | GROUNDING ELECTRODE SYSTEM. 250.50 | | | | 7) NOTE;: PLEASE SEE LOBBY WILL REQUIRED AN EMERGENCY | | BATTERY BACK UP LT OF SOME SORT TO MEET THE MIN | | LIGHTING LEVELS REQUIRED PER LS 101 7.8, 7.9 . (COMBO | | UNITS, MAY BE USED). (ONLY A SUGGESTION. | | | | 8) NOTE: PLEASE PROVIDE CLARIFICATION OF ADJACENT | | OFFICE SPACE , NOTED A CONSTRUCTION OFFICES. IS THIS | | STILLPART OF THE SAME TENANT? | | | | 9) NOTE: PLEASE CLARIFY THE ADJUSTEDSQ FT FOR SPACE. | | PLEASE SEE PERMIT APPLICATION, ENERGY CALCULATIONS, AND | | PLANS. | | PLEASE KNOW IF BLDG IS OVER 5K SQ FT, FBC 2004 CHAPTER | | WILL APPLY. | | PLEASE SEE 13-415.1.AB.1 | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | 2006-11-03 18:04:22 | IN ELEC |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2007-02-06 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-02-06 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-02-06 |
Time |
14:14 |
Sent To |
|
|
Notes |
2007-02-06 14:24:04 | *****APPROVED*****W/PROVISO | | | | | | | | SHEET LS-1.01 HAS BEEN STAMPED, INITIALED, AND DATED AS | | APPROVED.HOWEVER SHEET E-1 WILL NEED TO BE STAMPED BY | | FIRE WHEN THE ELECTRICAL PLAN REVIEW COMMENT HAS BEEN | | ADDRESSED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2007-01-09 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-01-09 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-01-09 |
Time |
14:09 |
Sent To |
|
|
Notes |
2007-01-09 14:56:15 | *****UNSAT***** | | | | THE FOLLOWING COMMENTS TAKEN FROM PREVIOUS FIRE PLAN | | REVIEW OF 11/21/2006 ARE TO BE READDRESSED AS FOLLOWS: | | | | | | | | 1.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL NOT | | HINDER OR INTERFERE WITH EMERGENCY ACCESS TO THE SAID | | PROPERTY OR THE VICINITY THEREOF.ILLUSTRATE ON THE | | APPROPIATE PLAN SHEET THAT THIS HAS BEEN ACKNOWLEDGED. | | | | 3.THE EXISTING BUILDING DOES NOT HAVE FIRE PROTECTION | | SYSTEM IN PLACE.INCLUDE IN THE SITE USE DATA TABLE | | (ON SHEET A-1.00) UNSPRINKLERED BUILDING | | | | **NEW COMMENT** | | | | 1.IN REFERENCE TO THE SMOKE DETECTORS LISTED ON SHEET | | LS-1.01, ARE THEY TIED INTO A FIRE ALARM SYSTEM?IF | | THEY ARE NOT, THESE DEVICES SHOULD BE SHOWN AS SMOKE | | ALARMS (SA) IN LIEU OF SMOKE DETECTORS (SD). | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-11-21 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-11-21 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-11-21 |
Time |
09:34 |
Sent To |
|
|
Notes |
2006-11-21 10:07:10 | *****DENIED***** | | | | | | | | 1.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL NOT | | HINDER OR INTERFERE WITH EMERGENCY ACCESS TO THE SAID | | PROPERTY OR THE VICINITY THEREOF. | | | | 2.WHAT TYPE OF OCCUPANCY WILL THE PROPOSED STRUCTURE | | BE? | | | | 3.DOES THE EXISTING BUILDING HAVE FIRE PROTECTION | | SYSTEM IN PLACE?IF SO, HOW WILL THEY BE AFFECTED BY | | THE SCOPE OF THE WORK? | | | | 4.IF THE FIRE PROTECTION SYSTEM IS MODIFIED OR IS | | ADDED TO THE BUILDING, SEPARATE PERMIT AND PLANS ARE | | REQUIRED. | | | | 5.PROVIDE A LIFE SAFETY PLAN WHICH INCLUDES ALL | | COMMON PATHS OF TRAVEL TO EXITS. | | | | 6.INDICATE LOCATION OF 2A-10BC FIRE EXTINGUISHERS AT | | DISTANCES TO SATISFY THE 75' TRAVEL DISTANCE | | REQUIREMENT. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2007-03-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-06 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-06 |
Time |
09:50 |
Sent To |
B |
|
Notes |
2007-03-06 09:51:06 | TO "MJACOBS" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-03-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-06 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-06 |
Time |
09:25 |
Sent To |
M |
|
Notes |
2007-03-06 09:25:59 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-02-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-16 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-16 |
Time |
16:26 |
Sent To |
|
|
Notes |
2007-02-16 16:26:52 | TO "BOB"#17 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-02-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-09 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-09 |
Time |
11:09 |
Sent To |
|
|
Notes |
2007-02-09 11:11:57 | TO "BOB"#10 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-01-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-20 |
Time |
12:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-20 |
Time |
12:57 |
Sent To |
|
|
Notes |
2007-01-20 12:57:49 | TO "BOB"#5 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-12-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-19 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-19 |
Time |
10:34 |
Sent To |
|
|
Notes |
2007-01-03 17:48:29 | TO "BOB"#13 | 2006-12-19 10:34:50 | WAITING FOR "BOB" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-11-21 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-11-21 |
Time |
09:34 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-10-30 |
Time |
10:37 |
Sent To |
|
|
Notes |
2006-11-03 14:44:48 | TO "BOB"#6 | 2006-10-30 10:38:26 | WAITING FOR "BOB" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2007-03-06 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-03-06 |
Time |
14:30 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-03-06 |
Time |
14:30 |
Sent To |
|
|
Notes |
2007-03-06 14:34:24 | REVISION TO MECHANICAL PLANS PAGE A/C-1 | | *** PROVISO *** | | 1) PROVIDE RETURN AIR FROM CORRIDOR TO EXISTING 3 TON | | ROOFTOP UNIT, SEE 2004 FBC/M 601.4. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-01-22 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-01-22 |
Time |
11:46 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-01-22 |
Time |
11:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-01-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-01-04 |
Time |
11:25 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-01-04 |
Time |
11:25 |
Sent To |
|
|
Notes |
2007-01-04 11:31:03 | *** DENIED *** | | 1) ONE SET OF PLANS PAGE AC-1 MECHANICAL IS MISSING | | SEAL, NEEDS TO BE SIGNED AND SEALED BY THE ENGINEER, | | PER FAC 61G15-23.002. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-11-06 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-11-06 |
Time |
11:34 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2006-11-06 |
Time |
11:34 |
Sent To |
|
|
Notes |
2006-11-06 11:44:03 | *** DENIED *** | | 1) PLEASE SHOW HOW OUTDOOR AIR IS TO GET TO THE 1 1/2 | | TON AHU. | | | | 2) SEE PAGE AC-1, OUTDOOR AIR CAL'S. SHOWS 440 CFM'S | | REQUIRED, BUT ONLY 250 CFM'S. ARE TO BE SUPPLIED, | | PLEASE EXPLAIN. | | | | 3) RETURN AIR TRANSFER DUCT TO OFFICE #109 IS TO SMALL, | | SEE (A) PLEASE CORRECT. | | BALANCED RETURN AIR. | | MAY BE ACHIEVED BY. | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | INCREASING THE RETURN TRANSFER ONE AND | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM OR SPACE IT'S SERVING | | AND THE DOOR HAVING AT LEAST AN | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | PROPER RETURN AIR BALANCE. | | (B)TRANSFER GRILLES SHALL USE 50 | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | CFM (OF SUPPLY AIR) FOR SIZING | | THROUGH-THE-WALL TRANSFER GRILLES AND | | USING AN UNRESTRICTED 1-INCH | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | RETURN AIR BALANCE | | (C)HABITABLE ROOMS ONLY SHALL BE | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | PROPER BALANCED RETURN AIR EXCLUDING | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | AIR INTO THE MASTER SUITE SHALL BE | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-01-29 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-01-29 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-01-29 |
Time |
08:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-01-09 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-01-09 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-01-09 |
Time |
08:34 |
Sent To |
|
|
Notes |
2007-01-09 09:00:55 | DENIED; | | 1. (FROM FIRST REVIEW #3NOT ADDRESSED) SHOW TOTAL | | NUMBER OF EMPLOYEES MUST COMPLY WITH FBC-2004 TABLE | | 403.1 (2B). SEPARATE FACILITIES EXCEPTIONS FOR SECTION | | 403.2 MUST BE SHOWN ON PLANS. | | 2. DEMO PLAN REQUIRED SHOWING ALL EXISTING PLUMBING TO | | BE REMOVED. ADD NOTE TO DEMO PAGE "NO DEAD ENDS | | PERMITED IN SANITARY DRAINAGE SYSYEM, INSPECTION | | REQUIRED) SEE SECTION 704.5 DEAD ENDS. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-11-18 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-11-18 |
Time |
07:23 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-11-18 |
Time |
07:23 |
Sent To |
|
|
Notes |
2006-11-18 07:43:36 | DENIED; | | 1. BATHROOM DOOR SHALL NOT SWING INTO THE CLEAR FLOOR | | SPACE OF THE LAVATORY. FBC-2004 BUILDING CHAPTER 11 | | SECTION 11-4.22.2. | | 2. SHOW DETAIL DRAWINGS FOR HANDICAP BATHROOM, BREAK | | SINK, AND DRINKING FOUNTAIN. SHOW ALL REQUIRED | | MEASUREMENTS. | | SEE THE FOLLOWING SECTIONS IN CHAPTER 11 FOR | | REQUIREMENTS; | | TOILET11-4.16.1 THRU 11-4.16.6. | | LAVATORY11-4.19.1 THRU 11-4.19.6 | | BREAK SINK 11-4.24.1 THRU 11-4.24.7 | | DRINKING FOUNTAIN11-4.1.3(10), | | 11-4.15.1 THRU 11-4.15.5 | | 3. SHOW COMPLIANCE TO FBC-2004 PLUMBING TABLE 403.1#2B | | SHOW TOTAL EMPLOYEES. MUST COMPLY WITH SEC 403.2. ONE | | DRINKING FOUNTAIN IS REQUIRED | | SEE SECTION 410.1, D/F MUST BE PART OF PLUMBING | | SYSTEM. | | 4. SHOW CLEAR FLOOR SPACE AND TURNING RADIUS ON FLOOR | | PLAN WHERE REQUIRED. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|