Plan Review Details - Permit 06101018
Plan Review Stops For Permit 06101018
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-05-03 Cont ID  
Sent By mjacobs Date 2007-05-03 Time 10:39 Rev Time 0.00
Received By mjacobs Date 2007-05-03 Time 10:23 Sent To E
Notes
2007-05-03 10:40:18TO 'BT' DESK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-04-13 Cont ID  
Sent By mjacobs Date 2007-04-13 Time 07:26 Rev Time 0.00
Received By mjacobs Date 2007-04-13 Time 07:12 Sent To PC
Notes
2007-04-13 07:25:57BUILDING PLAN REVIEW
 PERMIT:06101018
 ADD: 2100 PBL BLVD
 CONT: ANER SIGNS, INC
 TEL: (561)242-0405
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 3RD
 ACTION: DENIED
  
 1)THE ZONING COMENTS SHALL BE RESOLVED BEFORE A
 PERMIT CAN BE ISSUED. AS WAS NOTED IN THE ZONING NOTES
 THE DIMENTIONS STATED IN THE SPECIFICATIONS AND THE
 FRONT VIEW OF THE DRAWINGS ARE THE SAME.
  
 2)106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL. NOTE: SOME
 INFORMATION ON THE DRAWINGS ARE NOT LEGIBLE AND THE
 MATERIALS SHALL BE IDENTIFY. SEE QUESTION MARKS ON
 DRAWINGS.
  
 3)106.1.3 THE BUILDING OFFICIAL
 MAY SET STANDARDS THROUGH DEPARTMENTAL
 POLICY STANDARDS FOR PLANS AND SPRCIFICA
 TIONS. "NO WHITE OUT". "NO HAND WRITING ON DRAWINGS"
 ONLY THE DESIGNER OF RECORD CAN MAKE CHANGES TO
 TO THE DRAWINGS, WHICH WILL HAVE TO BE SIGN AND DATED
 BY THE DESIGNER.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-01-06 Cont ID  
Sent By mjacobs Date 2007-01-06 Time 16:43 Rev Time 0.00
Received By mjacobs Date 2007-01-06 Time 16:39 Sent To PC
Notes
2007-01-06 16:43:29BUILDING PLAN REVIEW
 PERMIT:06101018
 ADD: 2100 PBL BLVD.
 CONT: MCNEILL SIGNS INC.
 TEL: (561)737-6304
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 2ND
 ACTION: DENIED
  
 1)61G1-16.004THE ADDRESS OF THE ENGINEER BUSINESS
 SHALL REFLECT THE SAME ADDRESS THAT ISON THE DBPR
 WEB-SITE. SEE INFORMATION FROM THE STATE WEB-SITE IN
 PACKAGE WHICH HAS A DIFFERENT ADDRESS TO THE ONE ON THE
 DRAWINGS. CLARIFY.
  
 NOTE: SEC.1608 OF THE 2004 FBC IS RESERVED AND DOES NOT
 MAKE ANY REFERENCE TO WIND.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-11-30 Cont ID  
Sent By mjacobs Date 2006-11-30 Time 10:30 Rev Time 0.00
Received By mjacobs Date 2006-11-30 Time 09:18 Sent To PC
Notes
2006-11-30 10:25:43 
  
 BUILDING PLAN REVIEW
 PERMIT:06101018
 ADD: 2100 PBL. BLVD
 CONT: MCNEILL SIGNS INC.
 TEL: (954)946-3474
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW1ST
 ACTION: DENIED
  
 1) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS
 NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 2) THE CODE REFERENCES ON THE DRAWINGS ARE FROM THE
 2001 FBC.ALL PLANS SUBMITTED AFTER OCTOBER, 1,2005
 SHALL BE DESIGNED TO THE 2004 FLORIDA BUILDING CODE.
 ALSO THE ASCE STANDARD IS ASCE 7-02 NOT ASCE 7-98.
 SUBMIT NEW DRAWINGS WITH THE CORRECT CODE REFERENCES.
  
 3)THE ENGINEER SEAL SHALL BE LEGIBLE ON EACH SHEET.
 CONSTRUCTIONS DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO SHOW IN DETAIL THAT IT WILL CONFORM TO THE RELEVANT
 LAWS AS DETERMINED BY THE BUILDING OFFICAL.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-04-12 Cont ID  
Sent By btrobaug Date 2007-04-12 Time 13:46 Rev Time 0.33
Received By btrobaug Date 2007-04-12 Time 13:36 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-01-05 Cont ID  
Sent By btrobaug Date 2007-01-05 Time 15:03 Rev Time 0.33
Received By btrobaug Date 2007-01-05 Time 14:58 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-11-08 Cont ID  
Sent By btrobaug Date 2006-11-08 Time 11:02 Rev Time 0.33
Received By btrobaug Date 2006-11-08 Time 10:58 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-05-02 Cont ID  
Sent By adarroug Date 2007-05-02 Time 15:02 Rev Time 0.00
Received By adarroug Date 2007-05-02 Time 15:02 Sent To B
Notes
2007-05-02 15:02:30TO "MJACOBS" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-04-12 Cont ID  
Sent By adarroug Date 2007-04-12 Time 10:14 Rev Time 0.00
Received By adarroug Date 2007-04-12 Time 10:14 Sent To E
Notes
2007-04-12 10:14:37TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-03-29 Cont ID  
Sent By dpalmer Date 2007-03-29 Time 20:39 Rev Time 0.00
Received By dpalmer Date 2007-03-29 Time 20:39 Sent To Z
Notes
2007-03-29 20:40:09TO ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-01-02 Cont ID  
Sent By adarroug Date 2007-01-02 Time 16:07 Rev Time 0.00
Received By adarroug Date 2007-01-02 Time 16:07 Sent To E
Notes
2007-01-02 16:08:12TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-12-26 Cont ID  
Sent By adarroug Date 2006-12-26 Time 15:39 Rev Time 0.00
Received By adarroug Date 2006-12-26 Time 15:36 Sent To Z
Notes
2006-12-26 15:36:58TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-07 Cont ID  
Sent By adarroug Date 2006-11-07 Time 14:38 Rev Time 0.00
Received By adarroug Date 2006-11-07 Time 14:38 Sent To E
Notes
2006-11-07 14:39:15TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-11-30 Time   Rev Time 0.00
Received By adarroug Date 2006-10-28 Time 14:57 Sent To  
Notes
2006-10-28 14:57:46TO "Z" BOX

Review Stop Z ZONING
Rev No 4 Status P Date 2007-05-02 Cont ID  
Sent By kdfreema Date 2007-05-02 Time 14:48 Rev Time 0.00
Received By kdfreema Date 2007-05-02 Time 14:48 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2007-04-10 Cont ID  
Sent By adavila Date 2007-04-10 Time 16:41 Rev Time 0.00
Received By adavila Date 2007-04-09 Time 16:41 Sent To I
Notes
2007-04-10 16:41:35PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. PROVIDE LOT WIDTH DIMENSION OF SUBJECT PROPERTY.
  
 2. SUBMITTED SITE PLAN SHOWS BOTH PROPERTIES UNIFIED;
 HOWEVER, THE PALM BEACH COUNTY PROPERTY APPRAISER SHOWS
 IT AS 2 DIFFERENT PROPERTIES.IF THE SUBJECT PROPERTY
 IS UNIFIED WITH THE ADJACENT PROPERTY TO THE WEST,
 PLEASE PROVIDE A RECORDED UNITY OF TITLE.IF THE
 INTENT IS TO UNIFY BOTH PROPERTIES, A UNITY OF TITLE
 MUST BE RECORDED WITH THE PALM BEACH COUNTY PROPERTY
 APPRAISER?S OFFICE.
  
 3. PROVIDE TOTAL SQUARE FOOTAGE OF SIGN, INCLUDING
 BASE.
  
 4. PROVIDE WIDTH DIMENSION OF BASE.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-12-29 Cont ID  
Sent By mmclean Date 2006-12-29 Time 11:11 Rev Time 0.00
Received By mmclean Date 2006-12-29 Time 11:11 Sent To I
Notes
2006-12-29 11:11:36DENIED,
 1. SITEPLANS SUBMITTED 1997, WHICH IS NOT CURRENT AND
 DOES NOT SHOW THE LOCATION OF THE EXISTING SIGN. 2.
 SITEPLANS SHOWS BOTH PROPERTY 2100 & 2122 PALM BEACH
 LAKES AS ONE PARCEL, WHICH BOTH LOTS ARE SEPARATE WITH
 SEPARATE PROPERTY CONTROL NUMBER.
 3. NEED TO HAVE THE TWO COPIES OF CURRENT SURVEY WITH
 LOT DIMENSION AND THE LOCATION OF THE OLD SIGNS BEFORE
 DESTROYED BY HURRICANE.
 SEC 94-408(D)(2)
  
 NOTE: NEED VERIFICATION THAT THE EXISTING SIGN IS
 DEMOLISHED.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2006-11-04 Cont ID  
Sent By mmclean Date 2006-11-04 Time 14:26 Rev Time 0.00
Received By mmclean Date 2006-11-04 Time 14:26 Sent To I
Notes
2006-11-04 14:29:01DENIED,
 1. PLEASE PROVIDE A CURRENT SURVEY OF THE PROPERTY THAT
 SHOW THE LOCATION OF THE EXISTING SIGN WITH SETBACK.
 2. PLEASE PROVIDE A COPY OF EXISTING SIGN WITH
 DIMENSION.
 3. SITEPLAN 1968 (TOO OLD) AND DOES NOT PROVIDE THE
 DIMENSION OF THE LOT AND LOCATION OF THE EXISTING SIGN
 AND ADDRESS OF PROPERTY.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720