Plan Review Details - Permit 06100983
Plan Review Stops For Permit 06100983 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-11-03 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-11-03 |
Time |
07:11 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-11-03 |
Time |
06:58 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-10-30 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-10-30 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-10-30 |
Time |
14:19 |
Sent To |
PC |
|
Notes |
2006-10-30 16:17:52 | | | BUILDING PLAN REVIEW | | PERMIT:06100983 | | ADD:224 GRAY ST | | CONT:HORIZON ROOFING INC. | | TEL: (561)842-6120 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW2ND | | ACTION: DENIED | | | | 1)ONCE AGAIN(A) THE CONTRACTOR FAILED TO INDICATE | | WHICH APPROVED ASSEMBLY SYSTEM TO BE USED. HI-LIGHT OR | | CIRCLE THE SYSTEM WHICH WILL BE USED FROM THE 44 PAGE | | REPORT. | | (B)THE SYSTEM PROVIDED STATES LIMITATION #7, SHOULD | | THE FASTENER RESISTANCE BE LESS THAN THAT REQUIRED, AS | | DETERMINED BY THE BUILDING OFFICIAL, A REVISED | | FASTENER SPACING, PREPARED, SIGNED AND SEALED BY A | | FLORIDA REGISTERED PROFESSIONAL ENGINEER,ARCHITECT OR | | REGISTERED ROOF CONSULTANT MAYBE SUBMITTED. | | | | | | 2)THE ES LEGACY REPORT AND FL985-R1 DOES NOT | | CORRESPOND WITH EACH OTHER.SEE FLORIDABUILDING.ORG | | FOR NEW PRODUCT APPROVAL UPDATES. MAKE SURE THESTATE | | COVER SHEET MATCH THE NOA REPORTS. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-10-26 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-10-26 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-10-26 |
Time |
12:48 |
Sent To |
PC |
|
Notes |
2006-10-26 13:00:44 | BUILDING PLAN REVIEW | | PERMIT:06100983 | | ADD:224GRAY ST. | | CONT:HORIZON ROOFING INC. | | TEL: (561)842-6120 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW1ST. | | ACTION: DENIED | | | | | | | | 1) THIS ROOF IS MISSING OR NOT IN | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | _XX__ CONTRACTOR FAILED TO INDICATE WHICH | | SYSTEM TO BE USED. | | | | _XX__ THE SYSTEM PROVIDED HAS A LOW | | PRESSURE FOR ZONE _3__ . | | | | _XX__ THE SYSTEM PROVIDED STATES | | LIMITATION# 7, SHOULD THE FASTENER | | RESISTANCE BE LESS THAN THAT | | REQUIRED, AS DETERMINED BY THE | | BUILDING OFFICIAL, A REVISED | | FASTENER SPACING, PREPARED , SIGNED | | AND SEALED BY A FLORIDA REGISTERED | | PROFESSIONAL ENGINEER, REGISTERED | | ARCHITECT OR REGISTERED ROOF | | CONSULTANT MAY BE SUBMITTED. | | THE PRODUCT APPROVAL IS MISSING | | THE APPROVED ASSEMBLY. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-11-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-02 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-02 |
Time |
11:43 |
Sent To |
B |
|
Notes |
2006-11-02 11:44:00 | TO "MJACOBS"DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-10-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-30 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-30 |
Time |
11:22 |
Sent To |
B |
|
Notes |
2006-10-30 11:23:06 | TO "MJACOBS" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-10-26 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-10-26 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-10-26 |
Time |
12:47 |
Sent To |
|
|
Notes |
|
|
|