Plan Review Stops For Permit 06100524 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2007-10-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-10-30 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-10-30 |
Time |
10:20 |
Sent To |
|
|
Notes |
2007-10-30 10:27:32 | REVISED SHEET SP-1 HAS BEEN REVIEWED FOR CODE | | COMPLIANCE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2007-08-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-08-01 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-08-01 |
Time |
09:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2007-07-10 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-07-10 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-07-10 |
Time |
15:57 |
Sent To |
|
|
Notes |
2007-07-10 16:35:25 | REVISION OF SHEETS S1 - S6 IS DENIED | | | | 1) THIS REVISION INCREASES THE VALUE OF THE JOB. | | INDICATE THE AMOUNT OF THE INCREASE ON THE REVISION | | FORM AND HAVE THE INTAKE CLERK ADD THIS TO THE ORIGINAL | | VALUE. | | | | 2) ON SHEET S3 ONE OF THE PORCH DIMENSIONS IS MISSING. | | SEE RED MARKS ON THE DRAWING. | | | | 3) PROVIDE A SECTION THROUGH THE STAIRS SHOWN AT THE | | MASTER BEDROOM PORCH ON SHEET S3. | | | | 4) ON SHEET S4 THERE IS A SECTION TAG FOR 13/S6 AND | | THERE IS NO SUCH SECTION ON SHEET S6. PLEASE CORRECT. | | | | 5) ON SHEET S4, (2) 1-3/4"X 11-1/4" 1.95 MICROLAMS | | ARE SPECIFIED AND IN SECTION 9/S6 (2) 1-3/4" X 11-3/4" | | 1.9E MICROLAM BEAMS ARE SPECIFIED. PLEASE CORRECT. | | | | 6) SPECIFY THE TRUSS CONNECTORS FOR THE MASTER BEDROOM | | PORCH. | | | | 7) SECTION 5/S6 ON S4 IS IN THE WRONG LOCATION. IT | | NEEDS TO BE REVISED TO SHOW THE NEW MASTER BEDROOM | | PORCH. | | | | 8) IN DETAIL 3 ON S6 SPECIFY WHAT THE 5/8" DIA | | FASTENERS @ 24"OC ARE. ALSO CHECK THE SIMPSON | | CONNECTORS THAT ARE SPECIFIED ( LUZ10 AND HSTC 78). | | THESE COULD NOT BE FOUND IN THE SIMPSON CATALOG. SHOULD | | THESE BE LU210 AND MSTC 78 ? | | | | 9) ADDRESS ZONING COMMENTS. | | | | - ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-02-27 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-02-27 |
Time |
17:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-02-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-02-27 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-02-26 |
Time |
12:29 |
Sent To |
|
|
Notes |
2007-02-26 16:53:49 | DENIED BY BUILDING | | | | 1) THE NOA SUBMITTED FOR THE SOUTHEASTERN METALS MFG. | | CO. METAL ROOF IS EXPIRED. THE NOA NUMBER 06-1012.08 | | HAS NOT BEEN APPROVED BY MIAMI-DADE PRODUCT CONTROL | | DIVISION AT THIS TIME. STATUS STATES THAT ADDITIONAL | | INFORMATION HAS BEEN REQUESTED. | | | | 2) SPECIFY WHICH ONE OF THE APPROVED SYSTEMS LISTED IN | | THE FIRESTONE MODIFIED SYSTEM PRODUCT APPROVAL WILL BE | | INSTALLED. SPECIFY THE FASTENING OPTION AND DESIGN | | PRESSURE FOR THE SELECTED SYSTEM. CIRCLE THE | | APPROPRIATE ITEMS ON THE PRODUCT APPROVALS. IF ENHANCED | | FASTENING IS REQUIRED TO MEET THE HIGHER UPLIFT | | PRESSURES IN THE PERIMETER OR CORNER AREAS, SUBMIT RAS | | 117 CALCULATIONS PER LIMITATION #7 ON PAGE 34 OF THE | | NOA. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-02-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-02-05 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-02-05 |
Time |
06:36 |
Sent To |
|
|
Notes |
2007-02-05 10:27:02 | DENIED BY BUILDING | | | | 1)ON SHEET S2 THE TYPE AND NUMBER OF FASTENERS IS | | REQUIRED IN THE TRUSS CONNECTOR SCHEDULE FOR EACH OF | | THE UPLIFT VALUES LISTED. | | | | 2)SHOW COMPLIANCE WITH R320.1 FOR TERMITE | | PROTECTION. | | | | TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED | | TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, | | BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR | | OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED | | FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION | | (SEE SECTION 202 , REGISTERED TERMITICIDE). UPON | | COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE | | TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED | | TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL | | COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: ?THE | | BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE | | PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN | | ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE | | FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER | | SERVICES.? | | | | 3) SHOW COMPLIANCE WITH R319.1 WHERE FLOOR JOISTS ARE | | INSTALLED OVER EXISTING SLAB. | | IN AREAS SUBJECT TO DECAY DAMAGE AS ESTABLISHED BY | | TABLE R301.2(1) , THE FOLLOWING LOCATIONS SHALL REQUIRE | | THE USE OF AN APPROVED SPECIES AND GRADE OF LUMBER, | | PRESSURE TREATED IN ACCORDANCE WITH AWPA C1, C2, C3, | | C4, C9, C15, C18, C22, C23, C24, C28, C31, C33, P1, P2 | | AND P3, OR DECAY-RESISTANT HEARTWOOD OF REDWOOD, BLACK | | LOCUST, OR CEDARS | | 3.SILLS AND SLEEPERS ON A CONCRETE OR MASONRY | | SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS | | SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE | | BARRIER. | | | | 4) SHOW COMPLIANCE WITH R506.2.3 VAPOR RETARDER. | | A 6 MIL (0.006 INCH; 152 ?M) POLYETHYLENE OR APPROVED | | VAPOR RETARDER WITH JOINTS LAPPED NOT LESS THAN 6 | | INCHES (152 MM) SHALL BE PLACED BETWEEN THE CONCRETE | | FLOOR SLAB AND THE BASE COURSE OR THE PREPARED SUBGRADE | | WHERE NO BASE COURSE EXISTS. | | EXCEPTION: THE VAPOR RETARDER MAY BE OMITTED: | | 1.FROM GARAGES, UTILITY BUILDINGS AND OTHER | | UNHEATED ACCESSORY STRUCTURES. | | 2.FROM DRIVEWAYS, WALKS, PATIOS AND OTHER FLATWORK | | NOT LIKELY TO BE ENCLOSED AND HEATED AT A LATER DATE. | | 3.WHERE APPROVED BY THE BUILDING OFFICIAL, BASED | | ON LOCAL SITE CONDITIONS. | | NOTE: EXISTING SCREEN PORCH SLAB THAT IS BEING LEFT IN | | PLACE MAY NOT HAVE VAPOR RETARDER. | | | | 5) IN THE SECTION THROUGH THE GARAGE SLAB, SECTION 6 ON | | S5,THE SLAB IS SHOWN AT THE SAME ELEVATION AS THE | | EXTERIOR GRADE. THE SLAB IS REQUIRED TO BE A MINIMUM OF | | 4' ABOVE GRADE. SEE R404.1.6. | | | | 6)SHOW COMPLIANCE WITH WPB ADMIN CODE 106.3* PRODUCT | | APPROVALS. THOSE PRODUCT WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 7)SUBMIT PRODUCT APPROVALS FOR THE LARGE MISSLE | | IMPACT RATED DOUBLE AND SINGLE OUTSWING GLAZED FRENCH | | DOORS WITHOUT SIDELITES. THE ONES THAT WERE SUBMITTED | | ARE FOR DOORS WITH SIDELITES. | | | | 8)SUBMIT PRODUCT APPROVALS FOR THE NEW BAHAMA | | HURRICANE SHUTTERS. | | | | 9)SUBMIT PRODUCT APPROVALS FOR THE METAL ROOF. THE | | NOA SUBMITTED FOR THE SOUTHEASTERN METALS MFG. CO. | | METAL ROOF IS EXPIRED. | | | | 10) SUBMIT PRODUCT APPROVALS FOR THE ROOFING THAT WILL | | BE INSTALLED ON THE FLAT DECK. | | | | 11) SUBMIT TWO SETS OF TRUSS DRAWINGS THAT HAVE BEEN | | SIGNED AND SEALED BY THE TRUSS ENGINEER AND HAVE BEEN | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD FOR THE PROJECT PRIOR TO INSTALLATION. SEE | | R802.1.6. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-11-06 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-11-06 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-11-06 |
Time |
08:19 |
Sent To |
|
|
Notes |
2006-11-06 08:23:53 | DENIED | | | | 1.SHOW METHOD OD SLAB ATTACHMENT FROM EXISTING SLAB | | TO NEW. | | | | 2.PRODUCT APPROVALS REQUIRED FOR LINTELS. | | | | 3.ALL PRODUCT APPROVALS SUBMITTED WITH QUALITY | | ASSURANCE SHALL HAVE THE FOLLOWING STATE APPROVAL | | ATTACHED. | | NOTE:INCORRECT STATE PRODUCT APPROVAL PAGES SUBMITTED | | FOR WINGARD DOOR AND PGT SH 701.PGT SH 701 MIAMI-DADE | | IS EXPIRED. | | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT | | LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF | | THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN | | APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC | | FORM PER RULE 9B-72. SEE ATTACHMENT. | | WWW.FLORIDABUILDING.ORG | | | | 4.THOSE PRODUCT APPROVALS WHICH ARE REGULATED BY DCA | | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL.WPB AMENDMENT TO FBC 106.3.3. | | | | | | 5.SUBMIT TWO SETS OF TRUSS DRAWINGS FOR REVIEW PER | | 2004 FBC R-802.10.1TRUSS DRAWING REQUIRED TO BE | | APPROVED PRIOR TO INSTALLATION. | | | | 6.A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR | | A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | SECTIONS 303, 304 AND 305 OF THIS CODE.SHOW HOW PLANS | | WILL COMPLY WITH THE SECTION(S) SELECTED.2004 FBC | | EXISTING BUILDING 301.5 | | | | 7.R401.3 DRAINAGE. | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS | | TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO | | DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE | | GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM | | OF 6 INCHESWITHIN THE FIRST 10 FEET. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE | | COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET | | OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | | | | | ART LANGE | | BUILDING PLANS EXAMINER | | CONSTRUCTION SERVICES DEPARTMENT | | 561-805-6672 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-07-26 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-07-26 |
Time |
12:16 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2007-07-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-07-13 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-07-13 |
Time |
11:13 |
Sent To |
PC |
|
Notes |
2007-07-13 11:55:28 | **** PROVISO **** ** I | | | | | | 1) NOTE: PLEASE REVISE LOAD CALCULATIONS TO COORIDNATE | | WITH THE CIRCUITING ON PLANS AND MINIMUM REQUIRED PER | | NEC 220.31B. | | | | 2) NOTE: PLEASE SUBMIT REVISED UPDATE PANEL SCHEDULE(S) | | WITH ALL CIRCUITING AS SHOWN ON PLAN WITH COMPLETE | | SPECIFIC ROOMS AND AREAS PER 408.4 | | | | | | ** THE ABOVE MUST BE COMPLETED AND ON-SITE FOR | | INSPECTION BEFORE FINAL. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2007-07-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-07-03 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-07-03 |
Time |
16:52 |
Sent To |
PC |
|
Notes |
2007-07-03 17:00:39 | **** UNSAT ** | | | | 1) NOTE: PLEASE SEE PLANS MAY NOT BE SUBMITTED DONE | | WIHT INK AND WHITE OUT IN ANY CASE.FBC 106.1 | | PLEASE ALSO SEE THAT ALL OF THESE CHANGES WERE MADE TO | | PLANS WHICH WERE SIGNED, DATED AND SEALED BY AN | | ARCHITECT. FS 481.221 | | | | ** PLEASE GIVE CHANGES TO TO THE ARCHITECT OF RECORD. | | PLEASE ALSO SEE THE *PROVISO* NOTES WHICH WERE ATTACHED | | AND WRITTEN ON PLANS WHEN PERMIT WAS ISSUED. PLEASE SEE | | THESE NOTES ARE BELOW WHICH STILL NEED TO BE | | ADDRESSED. | | | | IF THERE ARE ANY QUESTIONS,PLEASE CALL. | | | | | | | | | | | | | | ** PROVISO/REVISON NEEDED ** | | | | | | 1) NOTE: PLEASE SEE 210.52B1, 210.11C1, 220.16 AS | | 1500VA SHALL BE FIGURED INTO THE LOAD CALCULATIONS FOR | | ONE, TWO OR *MORE* OF THE SMALL APPLIANCE CIRCUITS. | | | | 2) NOTE: PLEASE CORRELATE VA FOR GDO. | | | | ** PLEASE REVISE THE ABOVE ALONG WITH ANY OTHER | | ELECTRICAL REVISIONS BEFORE ROUGH ELECTRICAL | | INSPECTION. | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE IN | | CONTACTING THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-02-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-02-25 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-02-25 |
Time |
14:19 |
Sent To |
M |
|
Notes |
2007-02-25 14:39:21 | | | ** PROVISO/REVISON NEEDED ** | | | | | | 1) NOTE: PLEASE SEE 210.52B1, 210.11C1, 220.16 AS | | 1500VA SHALL BE FIGURED INTO THE LOAD CALCULATIONS FOR | | ONE, TWO OR *MORE* OF THE SMALL APPLIANCE CIRCUITS. | | | | 2) NOTE: PLEASE CORRELATE VA FOR GDO. | | | | ** PLEASE REVISE THE ABOVE ALONG WITH ANY OTHER | | ELECTRICAL REVISIONS BEFORE ROUGH ELECTRICAL | | INSPECTION. | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE IN | | CONTACTING THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-12-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-12-27 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-12-26 |
Time |
17:42 |
Sent To |
P |
|
Notes |
2006-12-27 08:08:23 | ***** UNSAT2ND REVIEW **** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL | | IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS, | | SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING | | REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT | | MADE ON PREVIOUS REVIEWS. | | | | ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | PREVIOUS REVIEW WITH A NO, OK OR A NO/OK. | | THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE | | PREVIOUS REVIEW NOTES. | | | | A NO IS IF THE COMMENT WAS NOT FULLY ADDRESSED AND/OR | | FURTHER EXPLANATION OR CHANGES IN PLANS OR DOCUMENTS | | ARE STILL NEEDED. THIS REVIEWER WILL TRY TO BETTER | | EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT. | | | | AN OK WILL BE LABELED AS SUCH ON THE SAME NUMERICAL | | COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS. | | | | A NO/OK MEANS PART OF THE COMMENT MAY HAVE BEEN | | ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW | | COMMENT MAY HAVE BEEN FULLY ADDRESSED. | | | | ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF | | THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH. | | | | | | 1) NOTE: NO, PLEASE SEE THIS IS THE SAME NOTE. PLEASE | | SEE THERE ARE STILL CODES ON ELECTRICAL PLANS WHICH ARE | | FROM THE 1996 NEC. (NOTE #37) | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE BE SURE PLANS REFLECT THE FOLLOWING CODES AT A | | MINIMUM. | | 2002 NFPA-70 (NEC. | | 2002 NFPA-72 FAC. | | | | 2) NOTE: OK/NO, SYMBOL WAS CHANGED; HOWEVER PLEASE SEE | | THAT THE NOTE ON E-2 STILL INDICATES SMOKE DETECTORS. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE NFPA-72 DEFINITIONS, THE SYMBOL FOR SMOKE | | DETECTION DEVICES SHOULD BE SA IF INDEED A DEVICE WHICH | | WILL BE INSTALLED TO DETECT AND SOUND. IF THERE IS A | | FIRE ALARM SYSTEM, THEN ONLY THEN WOULD THEY BE SD. | | | | 3) NOTE: NO/OK, PLEASE SEE NOTES ON PLANS ON E-2 WHICH | | ARE LABELED AS KEYNOTES STILL ARE IN QUESTION. PLEASE | | SEE MISSING #6. PLEASE ACTUALLY SHOW THE EQUIPMENT AND | | LOCATIONS ON PLANS. COMPLIANCE FOR SOME CODE REVIEW | | ITEMS CAN NOT BE DONE. | | PLEASE SEE MANY OF THE PREVIOUS ITEMS FROM THIS COMMENT | | WAS ADDRESSED, HOWEVER NOT ALL. | | | | | | **PREVIOUS REVIEW NOTE ** | | PLEASE CORRELATE RISER AND PLANS, AS PLANS CALL FOR A | | NEW METER/MAIN COMBO, YET RISER SHOWS AND MAIN AND A | | NEW PANEL?? | | PLEASE SEE RISER SHOWS THE IDENTIFICATION OF THE | | CONDUCTORS FROM THE METER TO THE MAIN AS "FEEDERS". | | PLEASE KNOW, THESE ARE INDEED SERVICE ENTRANCE | | CONDUCTORS TO THE MAIN. PLEASE KNOW FEEDERS ARE ONLY | | AFTER THE FIRST MEANS OF DISCONNECT. | | PLEASE SEE IN EITHER CASE THE CONDUCTOR SIZES ARE | | MISSING FOR THE SEC'S AND THE FEEDERS FROM THE MAIN TO | | PANELS? | | PLEASE SEE 240.4, 310.16, 100, 215.5, 230.7 ETC | | NO REVIEW FOR COMPLIANCE OF THESE CAN BE DONE AT THIS | | TIME. | | | | 4) NOTE: OK/NO, PLEASE SEE NOTE #10 COMMENTS WITH | | RESPECT TO CORRELATION OF OVER CURRENT PROTECTION, | | CONDUCTOR SIZES AND SIZE OF LOADS. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE INDICATE ALL PANEL AND EQUIPMENT SIZE AND | | CORRELATE WITH CONDUCTORS AND OCP. | | 240., 230.310 ETC. | | | | 5) NOTE: OK. | | | | 6) NOTE: OK/NO, PLEASE SEE THE PANEL SCHEDULE WAS | | SUBMITTED, HOWEVER THERE ARE ITEMS WHICH DO NO MEET | | MINIMUM CODE FOR OCP, CONDUCTORS SIZES ETC. | | PLEASE SEE COMMENTS ON THESE NOTES AND REDLINED PLANS. | | | | ** PREVIOUS REVIEW NOTE** | | PLEASE SUBMIT A PANEL SCHEDULE INDICATING ALL MINIMUM | | REQUIRED CIRCUITS FOR ALL NEW AND INDICATE EXISTING. | | PLEASE BE SURE PANEL SCHEDULE SHOWS ALL OCP DEVICES AND | | CONDUCTOR SIZES AS REQUIRED FOR MIN CIRCUITS. PLEASE | | KNOW WE ARE UNABLE TO REVIEW FOR CODE COMPLIANCE AT | | THIS TIME. | | 240.4,310.16, 424.3B, 210.52, ETC. | | FBC ADMIN SECTION 106.3.5.4(8). | | | | 7) NOTE: NO, PLEASE SEE 220.31B FOR MINIMUM LOAD | | CALCULATIONS, THIS MAY ACTUALLY AFFECT THE SERVICE AND | | SIZE. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE COMPLETE PANEL SCHEDULE AND CORRELATE LOAD | | CALCULATIONS FOR ALL DEDICATED ELECTRICAL CIRCUITS ON | | PLANS. PLEASE SEE THERE ARE SEVERAL DEDICATED CIRCUITS | | WHICH ARE NOT FIGURED INTO THE LOAD CALCS. FRIG, GDO, | | OTHERS SHOWN ETC. | | 220.31B, 220.16, 210.11 | | | | 8) NOTE: NO, PLEASE SEE CIRCUIT(S) SHOWN; HOWEVER | | PLEASE SEE THESE CAN NOT BE #14 OR 15A OCP. | | PLEASE SEE MASTER BATH RECEPTS. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE MISSING DEDICATED BATH(S) CIRCUIT(S) PER | | 210.52D, 210.11C3 | | | | 9) NOTE:NO, COULD NOT LOCATE ANY INDICATION OF THIS. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE MISSING DINING AREA/BREAKFAST AREA PER | | 210.52B1, 210.11C1, 220.16 | | | | 10) NOTE: NO, PLEASE SEE THE OCP AND CONDUCTOR SIZES | | FOR THE EACH OF THE CIRCUITS DO NOT MEET CODE. PLEASE | | SEE PANEL SCHEDULE SHOWS 50A OCP AND #6 AND EACH | | APPLIANCE CIRCUIT AS 240V? | | PLEASE ADJUST AND CORRELATE. | | | | | | **PREVIOUS REVIEW NOTE ** | | PLEASE SEE DISPOSAL IS BEING SHOWN WITH 2KW LOAD. | | PLEASE KNOW THIS UNIT IS MOST LIKELY A 120V UNIT AND | | 2KW EXCEEDS THE RATING OF A 20A CIRCUIT. PLEASE KNOW AS | | NO PANEL SCHEDULE WAS NOT SUBMITTED, IT IS UNCLEAR OF | | THE OCP AND THE SIZE OF THE CONDUCTORS INTENDED. 240.4, | | 310.16, ETC | | | | 11) NOTE: OK. | | | | 12) NOTE: OK. | | | | 13) NOTE:OK. | | | | 14) NOTE: OK. | | | | 15) NOTE:NO, PLEASE CLARIFY THE EXISTING AREAS AND | | NEW, AND MUCH IF THE EXISTING DWELLING IS BEING | | REMODELED AND CODE COMPLIANCE FOR RECEPT SPACING NEEDS | | TO BE VERIFIED. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE THERE ARE SOME AREAS WHICH APPEAR TO CONTAIN | | NEW WALLS, YET DO NOT MEET 210.52 FOR RECEPT SPACING. | | PLEASE INDICATED ALL NEW AND EXISTING (E) WHICH WILL OR | | DO MEET ABOVE. | | | | 16) NOTE: OK. | | | | 17) NOTE:OK/NO, PLEASE SEE A/C UNITS AS NOW SHOWN, | | HOWEVER PLEASE SEE MISSING DISCONNECTS FOR THE AHU?S | | WHICH SHOWS A RECEPT FOR UNIT. PLEASE SEE 440.11, | | 440.12 AS RECEPTS ARE NOT PERMITTED FOR THE CONNECTION | | OF THESE UNITS AND TO USE AS DISCONNECT EITHER. | | PLEASE ALSO SEE NEW NOTES WITH RESPECT TO CU?S. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE INCLUDE ANY NEW A/C EQUIPMENT AND DISCONNECTS | | IF APPLICABLE. | | | | 18) NOTE:NO, PLEASE SEE THE WASHER AND DRYER WAS | | IDENTIFIED, HOWEVER THERE ARE STILL TWO OTHER LOCATION | | WHICH APPEARS TO BE EQUIPMENT OF SOME KIND.PLEASE SEE | | PANEL SCHEDULE MENTIONS A WATER HEATER AND ELECTRIC FOR | | THIS UNIT, HOWEVER THIS IS NOT SHOWN ON PLANS. PLEASE | | SEE REDLINED SET. | | | | **PREVIOUS REVIEW NOTE ** | | PLEASE SEE NEW EQUIPMENT WHICH SEEMS TO BE SHOWN IN | | GARAGE BUT NOT IDENTIFIED? | | WASHER/ DRYER? | | | | **** NEW NOTES*** | | | | 1) NOTE: PLEASE SEE MISSING GFI RECEPTS PER 210.63 , | | 210.8A3. | | | | 2) NOTE: PLEASE SEE PREVIOUS REVIEW WHICH CONTAIN A | | NOTE IN ASTERISK ** WHICH SAID ** IMPORTANT**, WHICH | | REQUESTED FOR ALL OLD/VOIDED SHEETS TO BE COMPLETELY | | REMOVED FROM SETS AND ONLY INSERT NEW SHEETS INTO THE | | TWO COMPLETE SETS FOR REVIEW. PLEASE KNOW THIS WILL | | HELP IN THE REVIEW PROCESS TO EXPEDITE PLANS IN THE | | REVIEW AND PROCESSING. IF THESE ARE NOT REMOVED, THE | | CONTRACTOR WILL BE CONTACTED TO COME IN AND DO THIS | | BEFORE PLANS CAN BE PROCESSED FOR ISSUANCE. | | PLEASE SEE THAT ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE ONLY. | | | | 3) NOTE: PLEASE SEE ATTACHED NOTICE TO FLORIDA STATUTES | | 553.80(2)(B) WITH RESPECT TO REPEAT COMMENTS FOR CODE | | COMPLIANCE. THIS IS ONLY A NOTICE GIVEN AT THIS TIME. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | 2006-12-26 16:38:04 | 2006-12-26 18:07:32 | | NOTES TO FOLLOW, REVIEW STOPPED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-10-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-10-31 |
Time |
19:59 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-10-31 |
Time |
19:20 |
Sent To |
M |
|
Notes |
2006-10-31 19:59:19 | ***** UNSAT **** | | | | 1) NOTE: PLEASE BE SURE PLANS REFLECT THE FOLLOWING | | CODES AT A MINIMUM. | | 2002 NFPA-70 (NEC. | | 2002 NFPA-72 FAC. | | | | 2) NOTE: PLEASE SEE NFPA-72 DEFINITIONS, THE SYMBOL FOR | | SMOKE DETECTION DEVICES SHOULD BE SA IF INDEED A DEVICE | | WHICH WILL BE INSTALLED TO DETECT AND SOUND. IF THERE | | IS A FIRE ALARM SYSTEM, THEN ONLY THENWOULD THEY BE | | SD. | | | | 3) NOTE: PLEASE CORRELATE RISER AND PLANS, AS PLANS | | CALL FOR A NEW METER/MAIN COMBO, YET RISER SHOWS AND | | MAIN AND A NEW PANEL?? | | PLEASE SEE RISER SHOWS THE IDENTIFICATION OF THE | | CONDUCTORS FROM THE METER TO THE MAIN AS "FEEDERS". | | PLEASE KNOW, THESE ARE INDEED SERVICE ENTRANCE | | CONDUCTORS TO THE MAIN. PLEASE KNOW FEEDERS ARE ONLY | | AFTER THE FIRST MEANS OF DISCONNECT. | | PLEASE SEE IN EITHER CASE THE CONDUCTOR SIZES ARE | | MISSING FOR THE SEC'S AND THE FEEDERS FROM THE MAIN TO | | PANELS? | | PLEASE SEE 240.4, 310.16, 100, 215.5, 230.7 ETC | | NO REVIEW FOR COMPLIANCE OF THESE CAN BE DONE AT THIS | | TIME. | | | | 4) NOTE: PLEASE INDICATE ALL PANEL AND EQUIPMENT SIZE | | AND CORRELATE WITH CONDUCTORS AND OCP. | | 240., 230.310 ETC. | | | | 5) NOTE: PLEASE SUBMIT THE AIC RATINGS FOR NEW SERVICE | | EQUIPMENT ALONG WITH SELECTIVE COORDINATION WHICH IS TO | | BE DONE. | | 110.9, 240.12 | | | | 6) NOTE: PLEASE SUBMIT A PANEL SCHEDULE INDICATING ALL | | MINIMUM REQUIRED CIRCUITS FOR ALL NEW AND INDICATE | | EXISTING. | | PLEASE BE SURE PANEL SCHEDULE SHOWS ALL OCP DEVICES AND | | CONDUCTOR SIZES AS REQUIRED FOR MIN CIRCUITS. PLEASE | | KNOW WE ARE UNABLE TO REVIEW FOR CODE COMPLIANCE AT | | THIS TIME. | | 240.4,310.16, 424.3B, 210.52, ETC. | | FBC ADMIN SECTION 106.3.5.4(8). | | | | 7) NOTE: PLEASE COMPLETE PANEL SCHEDULE AND CORRELATE | | LOAD CALCULATIONS FOR ALL DEDICATED ELECTRICAL CIRCUITS | | ON PLANS. PLEASE SEE THERE ARE SEVERAL DEDICATED | | CIRCUITS WHICH ARE NOT FIGURED INTO THE LOAD CALCS. | | FRIG, GDO, OTHERS SHOWN ETC. | | 220.31B, 220.16, 210.11 | | | | 8) NOTE: PLEASE SEE MISSING DEDICATED BATH(S) | | CIRCUIT(S) PER 210.52D, 210.11C3 | | | | 9) NOTE: PLEASE SEE MISSING DINING AREA/BREAKFAST AREA | | PER 210.52B1, 210.11C1, 220.16 | | | | 10) NOTE: PLEASE SEE DISPOSAL IS BEING SHOWN WITH 2KW | | LOAD. PLEASE KNOW THIS UNIT IS MOST LIKELY A 120V UNIT | | AND 2KW EXCEEDS THE RATING OF A 20A CIRCUIT. PLEASE | | KNOW AS NO PANEL SCHEDULE WAS SUBMITTED, IT IS UNCLEAR | | OF THE OCP AND THE SIZE OF THE CONDUCTORS INTENDED. | | 240.4, 310.16, ETC | | | | 11) NOTE: PLEASE SEE NOTE ON PLANS CALLS FOR AFCI | | PROTECTION FOR RECEPTS, WHEREAS THIS IS UNDER THE 1999 | | NEC REQUIREMENTS. PLEASE SEE WE ARE UNDER THE 2002 NEC | | AND REQUIRES AFCI PROTECTIONS FOR ALL "OUTLETS" IN | | BEDRM/SLEEPING AREAS. | | PLEASE ALSO SEE THIS IS REQUIRED OF NEW SMOKE ALARMS, | | FANS, LTS, RECEPTS ETC. | | | | 12) NOTE: PLEASE SEE MISSING EQUIPMENT GROUNDING | | CONDUCTOR PER 250.6, 250.24B, 250.110, 250.122 | | | | 13) NOTE: PLEASE NOTE AND VERIFY THE EXISTING GROUNDING | | ELECTRODE SYSTEM FOR THE NEW SERVICE. | | 250.50 | | | | 14) NOTE: PLEASE SEE 210.8A6 AS ALL RECEPTS SERVING | | KITCHEN COUNTER SPACE ARE REQUIRED TO GFI/ GFI | | PROTECTED. | | | | 15) NOTE: PLEASE SEE THERE ARE SOME AREAS WHICH APPEAR | | TO CONTAIN NEW WALLS, YET DO NOT MEET 210.52 FOR RECEPT | | SPACING. | | PLEASE INDICATED ALL NEW AND EXISTING (E) WHICH WILL OR | | DO MEET ABOVE. | | | | 16) NOTE: PLEASE INDICATE ALL ROOM AND AREA | | DESIGNATIONS ON ELECTRICAL PLANS. | | 106.1.2 | | | | 17) NOTE: PLEASE INCLUDE ANY NEW A/C EQUIPMENT AND | | DISCONNECTS IF APPLICABLE. | | | | 18) NOTE: PLEASE SEE NEW EQUIPMENT WHICH SEEMS TO BE | | SHOWN IN GARAGE BUT NOT IDENTIFIED? | | WASHER/ DRYER? | | | | ** PLEASE KNOW AT THIS TIME AS THERE ARE MANY ITEMS NOT | | YET SUBMITTED, THERE MAY BE NEW COMMENTS ON NEW PLANS | | SUBMITTED. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | | | | | | | | | | 2006-10-31 19:21:11 | IN ELEC ON 10/31 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
6 |
Status |
P |
Date |
2008-01-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-30 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-30 |
Time |
10:04 |
Sent To |
PC |
|
Notes |
2008-01-30 10:05:21 | REVISION: "OK" SHEETS P1 AND P2. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
5 |
Status |
F |
Date |
2007-12-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-12-06 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-12-06 |
Time |
08:51 |
Sent To |
PC |
|
Notes |
2007-12-06 09:13:34 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | 06 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | GAS PLAN REVIEW: | | REVISION DENIED: | | | | 1. SHEET P1 AND P2: WITH THE GAS PIPING MATERIAL BEING | | CHANGED TO CSST AND LONGEST LONGEST LENGTH BEING | | INCREASED TO 123' THE GAS PIPING SYSTEM IS SIZED | | INCORRECTLY IN THE INTERIOR PER TABLE *402.4(14). | | PLEASE REFERENCE THE RED LINE CORRECTIONS TO THESE | | SHEETS AND ATTACHED TABLES TO THESE COMMENTS REFLECTING | | THE NEEDED CHANGES ON THE RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
F |
Date |
2007-10-29 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-10-29 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-10-29 |
Time |
15:34 |
Sent To |
B |
|
Notes |
2007-10-29 16:06:47 | REVISION DENIED | | REFERENCE: | | ** FBC-2004 WITH 05 & 06 REVISIONS, FUEL GAS. | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | REQUIREMENTS. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE (FAC). | | ** FLORIDA STATUTES (FS). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE ON THE REVISED | | PLANS: | | | | 1. SHEET P1 THE 1/2" GAS AND BTU LOAD FOR THE ADDED | | DRYER IS MISSING AND NEEDS TO BE INDICATED IN THE | | CLOUDED REVISION ON THE RESUBMITTED REVISION. PER | | *106.1.1, INFORMATION ON CONSTRUCTION DOCUMENTS AND | | *401.1, SCOPE. | | | | 2. SHEET P2 GAS ISOMETRIC RISER DIAGRAM: THE DRYER AND | | ITS BUT LOAD ARE MISSING FROM THE REVISION CLOUD. PER | | *106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS AND | | *401.1, SCOPE. | | | | 3. SHEET P2 GAS ISOMETRIC RISER DIAGRAM: THE GAS METER | | IS MISSING FROM THE GAS ISOMETRIC. PER *401.1, SCPOE. | | | | 4. SHEET P2 GAS ISOMETRIC RISER DIAGRAM: THE TOTAL BTU | | LOAD NEEDS TO REVISED WITH THE ADDITION OF THE DRYER. | | PER *401.1, SCOPE. | | | | 5. SHEET P2 GAS ISOMETRIC RISER DIAGRAM: PLEASE | | CLARIFY WHAT "PIPING MATERIALIS WARFLEX" IS. SHOULD IT | | READ AS "PIPING MATERIAL IS WARDFLEX"? AND PLEASE | | CLARIFY IF ALL PIPING MATERIAL IS BEING CHANGED TO | | WARDFLEX C.S.S.T. ON THE REVISION RESUBMITTAL. PLEASE | | CLEARLY IDENTIFY ALL PIPING MATERIALS BEING USED FOR | | EACH CUT SECTION OF PIPE. PER *106.1.1, INFORMATION ON | | COSTRUCTION DOCUMENTS AND *401.1, SCOPE. | | | | 6. SHEET P2 GAS ISOMETRIC RISER DIAGRAM: PLEASE | | CORRELATE THE GAS ISOMETRIC, WHICH HAS THE ADDED SUM OF | | THE INDICATED CUT SECTIONS OF PIPE OF FIFTY EIGHT FEET | | (58') AND HAS THE REMOTE OUTLET BEING INDICATED AS | | SIXTYFIVE FEET (65'). PER *106.1.1, INFORMATION ON | | CONSTRUCTION DOCUMENTS AND *401.1, SCOPE. | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2007-07-12 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-07-12 |
Time |
13:19 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2007-07-12 |
Time |
13:19 |
Sent To |
PC |
|
Notes |
2007-07-12 13:44:53 | DENIED REVISION | | REFERENCE: | | ** FBC-2004 FUEL GAS. | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | REQUIREMENTS. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE. | | ** FLORIDA STATUTES. | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1. PER PHONE CONVERSATION WITH DAVID BISHOP PLUMBING | | INSPECTOR THERE HAVE BEEN MANY CHANGES TO THIS GAS | | SYSTEM INCLUDING ADDING APPLIANCES, RELOCATING | | APPLIANCES, CHANGING PIPE SIZES AND MATERIALS.THE | | SUBMITTED SHEET P1 DOES NOT INDICATE ALL OF THESE | | CHANGES. | | NOTE: PLEASE SUBMIT SHEET P2, WITH THE NATURAL GAS | | ISOMETRIC RISER INDICATING ALL CHANGES FROM THE GAS | | METER LOCATION TO ANY CHANGES TO THE INTERIOR PIPING | | THAT IS DIFFERENT FROM THE APPROVED SET OF PLANS. THIS | | INCLUDES PIPE SIZES, PIPE MATERIAL, RELOCATED | | APPLIANCES AND THE ADDITION OF ANY APPLIANCES. | | | | 2. NOTE: PLEASE RESUBMIT SHEET P1 AND INDICATE ON THE | | FLOOR PLAN THE RELOCATION AND ADDITION OF GAS | | APPLIANCES AND PLEASE MAKE SURE THAT PLAN KEY NOTE #4 | | CORRELATES WITH SHEET P2. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2006-12-29 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-12-29 |
Time |
08:39 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-12-29 |
Time |
08:39 |
Sent To |
B |
|
Notes |
2006-12-29 08:45:11 | ****************PROVISO**************** | | PER FBC-2004 FUEL GAS, TABLES 402.4(2) AND 402.4(14) | | THE LONGEST LENGTH METER LOCATION FROM MOST REMOTE | | OUTLET IN THE BUILDING IS 100'. ANYTHING LONGER THAN | | THAT DISTANCE A REVISION WILL BE REQUIRED. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2006-11-02 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-11-02 |
Time |
10:09 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-11-02 |
Time |
10:09 |
Sent To |
B |
|
Notes |
2006-11-02 10:16:09 | UNSAT | | REFERENCE: FBC-2004 FUEL GAS | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR GAS PLAN | | REVIEW ON THE RESUBMITTAL TO MEET CODE COMPLIANCE: | | | | 1. NOTE THE SUBMITTED PLANS REFERENCE FBC-2001 FUEL | | GAS, TABLE 402(2), THIS IS WRONG THEY SHOULD REFERENCE | | FBC-2004 FUEL GAS TABLE 402.4 (2). | | | | 2. THEGAS PIPING INDICATED ON SHEET P1 FLOOR PLAN AND | | P2 GAS RISER MATERIAL IS INDICATED AS BEING 3/4" | | SCHEDULE 40 BLACK STEEL BEING INSTALLED IN A SLEEVE | | WITH THREE (3) 90 DEGREE TURNS.IT IS RECOMMENDED THAT | | THE GAS PIPE MATERIAL IN THE SLEEVE BE CHANGED TO 3/4" | | CSST {FBC-2004 FUEL GAS TABLE 404.4(14)} AND THAT THE | | SLEEVE BE INSTALLED WITH TWO (2) 90 DEGREE TURNS. | | PLEASE REFERENCE SHEETS P1 AND P2 INDICATING THESE | | CHANGES. | | | | 3. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2004 | | FUEL GAS CODE. | | | | 4. SHOW TYPE OF PIPING MATERIAL BEING | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-07-26 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-07-26 |
Time |
17:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2007-07-05 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-07-05 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-07-05 |
Time |
13:30 |
Sent To |
Z |
|
Notes |
2007-07-05 13:31:38 | REVISION ***FAILED*** | | | | | | 1)NO SITE PLAN OR ELEVATION PROVIDED. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2006-10-13 |
|
|
Cont ID |
|
Sent By |
swurafti |
Date |
2006-10-13 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
swurafti |
Date |
2006-10-13 |
Time |
16:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
14 |
Status |
N |
Date |
2008-01-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2008-01-25 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2008-01-25 |
Time |
16:33 |
Sent To |
P |
|
Notes |
2008-01-25 16:33:57 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
13 |
Status |
N |
Date |
2007-11-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-26 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-26 |
Time |
15:58 |
Sent To |
P |
|
Notes |
2007-11-26 15:58:26 | TO "P" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2007-10-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-10-12 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-10-12 |
Time |
16:03 |
Sent To |
Z |
|
Notes |
2007-10-12 16:03:20 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-26 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-26 |
Time |
09:36 |
Sent To |
E |
|
Notes |
2007-07-26 09:36:26 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-26 |
Time |
09:32 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-26 |
Time |
09:32 |
Sent To |
Z |
|
Notes |
2007-07-26 09:32:32 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2007-07-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-11 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-11 |
Time |
13:50 |
Sent To |
E |
|
Notes |
2007-07-11 13:50:34 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2007-07-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-03 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-03 |
Time |
14:55 |
Sent To |
HIST |
|
Notes |
2007-07-03 14:55:32 | TO HISTORIC |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2007-07-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-03 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-03 |
Time |
11:20 |
Sent To |
E |
|
Notes |
2007-07-03 11:20:36 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-07-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-02 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-02 |
Time |
15:55 |
Sent To |
P |
|
Notes |
2007-07-02 15:55:42 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-22 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-22 |
Time |
17:39 |
Sent To |
E |
|
Notes |
2007-02-22 17:39:43 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-12-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-26 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-26 |
Time |
16:33 |
Sent To |
E |
|
Notes |
2007-02-01 16:43:27 | | | ROUTED TO ROBBIE MCDOUGAL FOR BUILDING/STRUCTURAL | | REVIEW. | 2006-12-26 16:33:45 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-12-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-16 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-16 |
Time |
15:46 |
Sent To |
Z |
|
Notes |
2006-12-16 15:47:02 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-10-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-31 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-31 |
Time |
11:13 |
Sent To |
E |
|
Notes |
2006-10-31 11:13:40 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-11-06 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-11-06 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-10-16 |
Time |
09:49 |
Sent To |
|
|
Notes |
2006-10-16 09:52:15 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2007-02-27 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-02-26 |
Time |
08:21 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-02-27 |
Time |
14:57 |
Sent To |
B |
|
Notes |
2007-02-26 08:34:17 | NO MECHANICAL PLANS SUBMITTED, AND NO | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | THIS TIME. A/C CONTRACTOR WILL SUBMIT MECH. PLANS WHEN | | SUBMITTING APP. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-02-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-11-01 |
Time |
08:23 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-11-01 |
Time |
08:23 |
Sent To |
P |
|
Notes |
2006-11-01 08:32:51 | *** DENIED *** | | 1) PLEASE SUBMIT ENERGY CALCULATIONS, PER 2004 FBC | | 13-101.2.2. | | | | 2) PLEASE SUBMIT MANUAL J CALCULATIONS FOR WHOLE HOUSE, | | PER 2004 FBC/R M1401.3. | | | | 3)NO MECHANICAL PLANS SUBMITTED, AND NO MECHANICAL | | PERMIT NUMBER APPLIED FOR AT THIS TIME. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2008-01-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2008-01-30 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2008-01-30 |
Time |
10:02 |
Sent To |
G |
|
Notes |
2008-01-30 10:03:56 | REVISION: "OK" SHEETS P1 AND P2. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2007-12-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-12-06 |
Time |
07:37 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-12-06 |
Time |
07:36 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2007-10-29 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-10-29 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-10-29 |
Time |
15:18 |
Sent To |
G |
|
Notes |
2007-10-29 15:33:58 | REVISION DENIED | | REFERENCE: | | ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING. | | ** FBC-2004 CHAPTER 1, THE CITY OF | | WEST PALM BEACH AMENDMENTS. | | ** FLORIDA ADMINISTRATIVE CODE (FAC). | | ** FLORIDA STATUTES (FS). | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE ON THE | | REVISED PLANS: | | | | 1. SHEET P1 SANITARY FLOOR PLAN DOES NOT REFLECT THE | | SANITARY ISOMETRIC ON SHEET P2: THE TRAP FOR THE MOP | | SINK IS MISSING. PER *701.1, SCOPE. | | | | 2. SHEET P2 SANITARY ISOMETRIC RISER DIAGRAM DOES NOT | | REFLECT THE FLOOR PLAN ON SHEET P1: THE WYE FITTING IS | | NOT INDICATED FOR THE WASHING MACHINE. PER *701.1, | | SCOPE. | | | | 3. SHEET P2 SANITARY ISOMETRIC RISER DIAGRAM: THE | | FOLLOWING NEEDS TO BE INDICATED FOR THE WASHING | | MACHINE. | | | | (A) PER *708.7 MINIMUM SIZE. CLEANOUTS SHALL | | BE THE SAME NOMINAL SIZE AS THE PIPE | | THEY SERVE UP TO 4 INCHES (102MM) | | **NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE THREE | | INCH (3"). | | | | (B) PER *708.9 ACCESS. ACCESS SHALL BE | | PROVIDED TO ALL CLEANOUTS. | | **NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE | | LOCATED AT FOUR FEET ABOVE FINNISH FLOOR (4' A.F.F.). | | | | END OF COMMENTS: | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-12-29 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-02-26 |
Time |
08:06 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2006-12-29 |
Time |
08:34 |
Sent To |
G |
|
Notes |
2006-12-29 08:39:12 | ****************PROVISO**************** | | PER FBC-2004 PLUMBING, SEC. 708.9 ACCESS SHALL BE | | PROVIDED TO ALL CLEANOUTS. CLEANOUT FOR WASHING MACHINE | | TO BE LOCATED FOUR FEET ABOVE FINNISH FLOOR. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-11-02 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-12-12 |
Time |
09:43 |
Rev Time |
1.25 |
Received By |
mperson |
Date |
2006-11-02 |
Time |
09:33 |
Sent To |
G |
|
Notes |
2006-11-02 10:08:52 | UNSAT | | REFERENCE: FBC-2004 PLUMBING | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | PLAN REVIEW ON THE RESUBMITTAL TO MEET CODE | | COMPLIANCE: | | | | 1. NOTE: THE SUBMITTED PLANS REFERENCE FBC-2001 | | PLUMBING, THIS IS WRONG THEY SHOULD REFERENCE FBC-2004 | | PLUMBING. | | | | 2.THE SANITARY RISER DIAGRAM ON SHEET P2 DOES NOT | | REFLECT THE FLOOR PLAN ON SHEETS A-1 AND P1. NOT ALL OF | | THE PLUMBING FIXTURES ARE INDICATED ON THE SANTARY | | RISER DIAGRAM. PLEASE REFERNCE SHEET A-1 IN THE | | GARAGE-6 WHERE THE 24" MOP SINK IS INDICATED. | | | | 3. 1. PER FBC-2004, PLUMBING, SECTION 909.1 | | WET VENT PERMITTED: ONLY THE FIXTURES | | WITHIN THE BATHROOM GROUPS SHALL CONNECT | | TO THE WET-VENTED HORIZONTAL BRANCH | | DRAIN. ANY ADDITIONAL FIXTURES SHALL | | DISCHARGE DOWNSTREAM OF THE WET VENT. (NOTE: PLEASE | | REFERENCE THE CORRECTED SHEETS P1 AND P2 WHERE THE MOP | | SINK ON SHEET A-1 IS ADDED TO SHEET P1 FLOOR PLAN AND | | SHEET P2 SANITARY RISER FOR THE RESUBMITTAL.) | | | | 4. THE BRANCH DRAIN PIPING TO THE WASHING MACHINE IS | | SIZED WRONG PER FBC-2004 PLUMBING SEC. 406.3. | | (A) 406.3 WASTE CONNECTIONS.THE TRAP AND | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | (51MM) IN DIAMETER. THE AUTOMATIC | | CLOTHES WASHER FIXTURE DRAIN SHALL | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | DIAMETER. (NOTE: PLEASE REFERENCE THE CORRECTED SHEETS | | P1 AND P2 FOR THE RESUBMITTAL.) | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2007-10-16 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-10-16 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-10-16 |
Time |
10:30 |
Sent To |
P |
|
Notes |
2007-10-16 10:31:28 | ***APPROVED - REVISION*** | | | | SENT TO "P" - MP |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2007-07-26 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-07-26 |
Time |
17:52 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-07-26 |
Time |
17:52 |
Sent To |
B |
|
Notes |
2007-07-26 17:55:31 | ***FAILED - REVISION*** | | | | | | 1)SETBACK DIMENSIONS SHALL BE INDICATED FROM ALL | | PROPOSED WORK TO THE PROPERTY LINES. | | | | 2)SHOW ANY PROPOSED MECHANICAL / A/C EQUIPMENT WITH | | SETBACK DIMENSIONS TO THE PROPERTY LINES. | | | | 3)PROVIDE OVERHANG DIMENSIONS FROM WALL TO THE | | OUTERMOST POINT OF THE ROOF'S EDGE. | | | | 4)PROVIDE ELEVATION PLANS OF ALL PROPOSED WORK | | (PREVIOUS COMMENT). | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2007-07-05 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-07-05 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-07-05 |
Time |
13:33 |
Sent To |
B |
|
Notes |
2007-07-05 13:36:51 | ***FAILED - REVISION*** | | | | | | 1)PLEASE PROVIDE TWO (2) COPIES OF EACH:CURRENT | | SURVEY SHOWING SCOPE OF WORK WITH ALL DIMENSIONS AND | | SETBACK DIMENSIONS TO PROPERTY LINES.SITE PLANS OF | | PROPOSED WORK.ELEVATIONS OF PROPOSED WORK. | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | TECHNICIAN | | (561)805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-12-22 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-12-22 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-12-22 |
Time |
10:41 |
Sent To |
I |
|
Notes |
2006-12-22 11:06:03 | NOTE: MUST HAVE HISTORIC SIGN-OFF FOR ANY REVISION. | | | | NOTE: SHALL PULL A SEPARATE PERMIT FOR NEW FENCE/GATE | | WITH EASEMENT APPROVAL FROM THE CITY OF WEST PALM BEACH | | UTILITY DEPT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-10-28 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-10-28 |
Time |
07:18 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-10-28 |
Time |
10:41 |
Sent To |
I |
|
Notes |
2006-10-28 07:31:52 | DENIED, | | 1.PLEASE PROVIDE A COPY OF CURRENT SURVEY OF THE | | PROPERTY. | | | | | | NOTE: MUST PULL A SEPARATE PERMIT FOR FENCE/GATE WITH | | UTILITY EASEMENT APPROVAL FROM CITY OF WEST PALM BEACH | | UTILITY DEPT. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|