Plan Review Details - Permit 06100482
Plan Review Stops For Permit 06100482
Review Stop AD ADDRESSING
Rev No 3 Status N Date 2006-12-13 Cont ID  
Sent By lursu Date 2006-11-15 Time 16:26 Rev Time 0.00
Received By jwitmer Date 2006-11-15 Time 16:26 Sent To  
Notes
2006-11-15 16:27:06PERMIT ATTACHED TO PCN = 74424302090003440

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2006-11-01 Cont ID  
Sent By lursu Date 2006-11-01 Time 16:53 Rev Time 0.00
Received By lursu Date 2006-11-01 Time 16:53 Sent To  
Notes
2006-11-01 16:54:52IS THE WORK DONE TO BOTH UNITS :344 & 345, THEN UNITY
 OF TITLE IS REQUIRED PRIOR OF ISSUING THE PERMIT.

Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-10-17 Cont ID  
Sent By lursu Date 2006-10-17 Time 11:20 Rev Time 0.00
Received By lursu Date 2006-10-14 Time 18:16 Sent To PC
Notes
2006-10-17 11:20:56NEW RECORD , PCN = 74 42 43 02 09 000 3440 HAD BEEN
 IMPORTED
2006-10-14 18:16:37COPY OF APPL SENT TO LILI

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-12-14 Cont ID  
Sent By jwitmer Date 2006-12-14 Time 08:43 Rev Time 1.66
Received By jwitmer Date 2006-12-13 Time 16:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-11-01 Cont ID  
Sent By alange Date 2006-11-01 Time 09:20 Rev Time 0.00
Received By alange Date 2006-11-01 Time 09:14 Sent To  
Notes
2006-11-01 09:22:21DENIED
  
 1.CONSTRUCTION TYPE VI DOES NOT EXIST UNDER THE 2004
 FBC PLEASE REVISE.
  
 2.A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR
 A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.SHOW HOW PLANS
 WILL COMPLY WITH THE SECTION(S) SELECTED.2004 FBC
 EXISTING BUILDING 301.5
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE
 COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DEPARTMENT
 561-805-6672
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-02-18 Cont ID  
Sent By dpalmer Date 2007-02-18 Time 15:32 Rev Time 0.00
Received By dpalmer Date 2007-02-18 Time 15:19 Sent To PC
Notes
2007-02-18 15:32:47REDLINED MAX TIMES FOR OC DEVICES PER 13-415.1.ABC.1.1,
 .1.2
 30MINS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-12-08 Cont ID  
Sent By dpalmer Date 2006-12-08 Time 14:52 Rev Time 0.00
Received By dpalmer Date 2006-12-08 Time 14:14 Sent To I
Notes
2006-12-08 14:53:56REDLINED MAX TIME ON OC DEVICES 30MINS, ALSO REDLINED
 700.12E FOR EM/EXT LTS.
2006-12-08 14:15:12PLANS REMOVED FROM INCOMING AND WILL BE ROUTED BACK TO
 INCOMING ONCE ELECTRICAL REVIEW IS DONE.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-10-26 Cont ID  
Sent By dpalmer Date 2006-10-26 Time 07:06 Rev Time 0.00
Received By dpalmer Date 2006-10-25 Time 20:57 Sent To  
Notes
2006-10-26 07:15:57** UNSAT **
  
 1) NOTE: PLEASE INCLUDE THE FOLLOWING MIN CODES WHICH
 ARE RELEVANT TO DESIGNA DN SCOPE PF WORK ON PLANS.
 2002 NFPA-70, 2002 NFPA-72, 2003 NFPA-101
  
 2) NOTE: PLEASEINDICATE THE "EQUIPMENT GROUNDING
 CONDUCTOR: FOR THE NEW FEEDERS BEING PULLED FROM
 EXISTING MAIN AT SERVICE.
 250.110,250.24B , 250.122 ETC
  
 3) NOTE: PLEASE SEE THAT THE ROOMS/OFFICE WHERE NEW
 ELECTRICAL LIGHTING CONTROLS/LAYOUTS WORK IS BEING WILL
 BE REQUIRED TO HAVE OCCUPANT SENSOR TYPE DEVICES TO BE
 INSTALLED. 13-415.1.ABC.1.2 2004 FBC.
  
 4) NOTE: PLEASE VERIFY THE VOLTAGE COMING INTO SPACES ?
 IT WAS THOUGHT THE VOLTAGE WAS 277/480 COMING INTO
 SPACES ? PLEASE ONLY VERIFY. IF INDEED 120/208V THIS IS
 OK.
  
 5) NOTE: PLEASE CORRELATE CIRCUITS ON PANEL SCHEDULE
 WIHT ROOMS /AREAS ON PLANS,. IE: OFFICE 102 RECEPT, LT
 RECEPTION AREA ,, ETC.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
2006-10-25 20:57:22IN ELEC FOR REVIEW

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2006-12-14 Cont ID  
Sent By mawillia Date 2006-12-14 Time 11:01 Rev Time 0.00
Received By mawillia Date 2006-12-14 Time 11:01 Sent To  
Notes
2006-12-14 11:07:40*****APPROVED***** W/ ATTENTION
  
  
  
  
 AS STATED BEFORE IN THE PREVIOUS FIRE PLAN REVIEW, THE
 CORRECT ADDRESS SHOULD BE REFLECTED IN THE TITLE BLOCK
 OF EACH SUBMITTED PLAN SHEET.WITH THE EXCEPTION OF
 SHEET A1 AND A2, ALL OTHER SHEETS STILL HAVE THE
 INCORRECT NUMERICAL 5405 INSTEAD OF 5407.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-10-27 Cont ID  
Sent By mawillia Date 2006-10-27 Time 10:43 Rev Time 0.00
Received By mawillia Date 2006-10-27 Time 10:43 Sent To  
Notes
2006-10-27 12:31:45*****DENIED*****
  
  
  
 1.THE SUBMITTED PLANS INDICATE THAT THE SCOPE OF WORK
 WILL BE CONDUCTED AT 5405 NO. HAVERHILL ROAD.AS PER
 WEST PALM BEACH ADDRESSING DEPARTMENT, THE CORRECT
 ADDRESS FOR THIS BUILDING IS 5407.THE CORRECT ADDRESS
 SHOULD BE REFLECTED IN THE TITLE BLOCK.
  
 2.PROVIDE EXISTING FLOOR PLAN TO DETERMINE IF BAY 44
 & 45 WILL BE ONE UNIT SPACE.IF SO, WHAT WILL THE UNIT
 SPACE NUMBER BE?
  
 3.NFPA 101 - 2003 EDITION, AND FLORIDA FIRE
 PREVENTION CODE - 2004 EDITION SHALL BE REFERENCED.
  
 4.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 5.FIRE EXTINGUISHERS ARE RATED 2A-10BC RATED,
 CERTIFIED AND TAGGED.(SEE SHEET A2)
  
 6.ONLY TWO OF THE THREE FIRE EXTINGUISHERS COULD BE
 LOCATED.
  
 7.INTERIOR FINISH FOR WALLS AND CEILING IN EXITS AND
 EXIT ACCESS CORRIDORS SHALL BE CLASS "A" OR CLASS"B".
 (SEE SHEET A2)
  
 8.SHOW THE LOCATION OF THE FIRE SPRINKLERS.HOW WILL
 THEY BE AFFECTED BY THE SCOPE OF THE WORK?
  
 9.IF THE SCOPE OF THE INTERIOR BUILDOUT REQUIRES
 MODIFICATION OF THE SPRINKLER SYSTEM, SEPARATE PERMIT
 AND PLANS ARE TO BE SUBMITTED.
  
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-02-16 Cont ID  
Sent By adarroug Date 2007-02-16 Time 08:52 Rev Time 0.00
Received By adarroug Date 2007-02-16 Time 08:52 Sent To E
Notes
2007-02-16 08:53:12TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-20 Cont ID  
Sent By adarroug Date 2006-11-20 Time 16:05 Rev Time 0.00
Received By adarroug Date 2006-11-20 Time 16:05 Sent To  
Notes
2006-12-12 17:34:48TO "BOB"#9
2006-11-20 16:05:38WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-11-01 Cont ID  
Sent By alange Date 2006-11-01 Time 09:22 Rev Time 0.00
Received By alange Date 2006-10-14 Time 18:17 Sent To  
Notes
2006-10-23 10:14:48TO "BOB"#16
2006-10-14 18:16:56WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-10-24 Cont ID  
Sent By tgordon Date 2006-10-24 Time 14:03 Rev Time 0.00
Received By tgordon Date 2006-10-24 Time 14:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-10-30 Cont ID  
Sent By jleech Date 2006-10-30 Time 13:50 Rev Time 0.00
Received By jleech Date 2006-10-30 Time 13:50 Sent To  
Notes
***NONE***