Plan Review Stops For Permit 06100099 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-10-23 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-10-23 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-10-23 |
Time |
08:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-01-29 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-01-29 |
Time |
08:18 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2007-01-29 |
Time |
07:55 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-12-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-12-01 |
Time |
06:54 |
Rev Time |
0.75 |
Received By |
btrobaug |
Date |
2006-12-01 |
Time |
06:36 |
Sent To |
P |
|
Notes |
2006-12-01 06:54:32 | | | DENIED | | | | THERE ARE TWO DIFFERENT RISER DIAGRAMS SUBMITTED. | | CHOOSE THE ONE TO BE INSTALLED AND RESUBMIT TWO COPIES | | FOR REVIEW. | | | | A SIGN SHALL BE PLACED AT THE SERVICE-ENTRANCE | | EQUIPMENT THAT INDICATES THE TYPE AND LOCATION OF | | ON-SITE OPTIONAL STANDBY POWER SOURCES. PLEASE NOTE | | SAME ON RISER. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-10-19 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-10-19 |
Time |
17:58 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-10-19 |
Time |
17:38 |
Sent To |
M |
|
Notes |
2006-10-19 17:58:21 | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | 1} PROVIDE MANUFACTURERS SPECIFICATIONS AND | | RECOMMENDATION, REGARDING CLEARANCES FOR THE | | GENERATOR. | | | | 2} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, | | METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED. | | DO THIS ON A SITE PLAN, NOT ON THE SURVEY, 106.1.3FBC. | | | | 3} THE PERSON TAKING RESPONSIBILITY FOR THE | | PLAN/DRAWINGS, SHALL PRINT AND SIGN THEIR NAME ON THE | | SHEETS THEY DRAW. PLEASE DO THIS PRIOR TO | | RESUBMITTING. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW. | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2006-12-01 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-12-01 |
Time |
08:50 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-12-01 |
Time |
08:50 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2006-10-20 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-10-20 |
Time |
13:11 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-10-20 |
Time |
13:11 |
Sent To |
B |
|
Notes |
2006-10-20 13:19:57 | UNSAT | | REFERENCE: FBC-2004 FUEL GAS | | | | THE FOLLOWING INFORMATION IS REQUIRED FOR GAS PLAN | | REVIEW: | | | | 1. PER ZONING COMMENTS PLEASE CORRELATE THE SURVEY | | PLAN. | | | | 2. PROVIDE MANUFACTURERS SPECIFICATIONS AND | | RECOMMENDATIONS REGAURDING CLEARENCES FOR GENERATOR. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-01-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-23 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-23 |
Time |
13:27 |
Sent To |
E |
|
Notes |
2007-01-23 13:27:34 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-11-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-17 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-17 |
Time |
09:59 |
Sent To |
E |
|
Notes |
2006-11-17 09:59:25 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-11-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-15 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-15 |
Time |
13:12 |
Sent To |
Z |
|
Notes |
2006-11-15 13:12:50 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-10-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-17 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-17 |
Time |
16:50 |
Sent To |
E |
|
Notes |
2006-10-17 16:50:18 | TO "GEN-RES "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-10-23 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-10-23 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-10-06 |
Time |
09:13 |
Sent To |
|
|
Notes |
2006-10-06 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-12-01 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-12-01 |
Time |
10:36 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-12-01 |
Time |
10:36 |
Sent To |
|
|
Notes |
2006-12-01 10:38:35 | *** PROVISO *** | | 1) PER 2004 FBC, FUEL GAS - POWERED | | EQUIPMENT - PERMANENTLY INSTALLED | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | WITH MANUFACTURER'S INSTALLATION | | INSTRUCTIONS AND NFPA 37. | | | | NFPA 37 INSTALLATION & USE OF STATIONARY COMBUSTION | | ENGINES & GAS TURBINES: | | 4.1.4ENGINES (GENERATORS) LOCATED | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE RESISTANCE | | RATING OF 1 HOUR OR (2) THE WEATHERPROOF ENCLOSURE IS | | CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS, AND IT HAS | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | MATERIALS OUTSIDE THE ENCLOSURE. | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | THE VENTILATION INTAKES. | | | | 2004 FMC 804.3.5 #3, WHERE THE | | TERMINATION IS LOCATED BELOW AN ADJACENT | | ROOF STRUCTURE, THE TERMINATION POINT | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | ROOF STRUCTURE. | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | INTO THE REQUIRED SETBACK, GENERATORS | | SHALL MAINTAIN THE REQUIRED ABOVE | | MENTIONED CLEARANCES TO THE ADJACENT | | PROPERTY STRUCTURES, I.E. FENCE, | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | FOLLOW MANUFACTURER'S RECOMMENDED | | CLEARANCES AROUND EQUIPMENT FOR | | SERVICING,AND PROVIDE MANUFACTURER'S | | INSTALLATION INSTRUCTIONS AT THE JOBSITE | | FOR THE FIELD INSPECTOR. | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-10-20 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-10-20 |
Time |
08:49 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-10-20 |
Time |
08:49 |
Sent To |
P |
|
Notes |
2006-10-20 08:51:21 | *** DENIED *** | | 1) SEE ZONING REVIEW NOTES, PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-11-16 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-11-16 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-11-16 |
Time |
15:09 |
Sent To |
I |
|
Notes |
2006-11-16 15:10:33 | NOTE: THE PROPOSED GENERATOR SHALL NOT BE CLOSER THAN | | 6FT FROM SIDE PROPERTY LINE. THE PROPOSED GENERATOR | | MUST BE SCREEN WITH A LANDSCAPE BUFFER. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-10-11 |
|
|
Cont ID |
|
Sent By |
kdfreema |
Date |
2006-10-11 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
kdfreema |
Date |
2006-10-11 |
Time |
12:09 |
Sent To |
|
|
Notes |
2006-10-11 12:10:51 | PLEASE CLARIFY DISTANCE FROM PROPERTY LINE AS SHOWN ON | | SURVEY. IF THE HOUSE IS 14? FROM THE PROPERTY LINE HOW | | CAN THE GENERATOR BE 15? FROM THE PROPERTY LINE? | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 822-1435 WITH | | ANY QUESTIONS YOU MAY HAVE. |
|
|