Plan Review Details - Permit 06090790
Plan Review Stops For Permit 06090790 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-11-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-11-07 |
Time |
08:25 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2006-11-07 |
Time |
07:54 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-10-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-10-17 |
Time |
15:00 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2006-10-17 |
Time |
15:00 |
Sent To |
|
|
Notes |
2006-10-17 15:07:08 | BUILDING REVIEW 2ND CHECKLIST: | | 1- ANCHOR TYPE SPECIFIEDIN THE INSTALLATION SCHEDULE | | DOESN'T MATCH ANCHOR SPECIFIED ON ACCORDION SHUTTERS | | AND STORM PANELS DRAWINGS. REVISE AS REQUIRED. | | | | 2- REVISE ANCHOR SPACING ACCORDING TO THE EDGE | | DISTANCE. SEE TABLES IN ACCORDION SHUTTERS AND STORM | | PANELS DRAWINGS AND REVISE AS REQUIRED. | | | | 3- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-10-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-10-05 |
Time |
09:16 |
Rev Time |
0.75 |
Received By |
jgomez |
Date |
2006-10-05 |
Time |
07:45 |
Sent To |
|
|
Notes |
2006-10-05 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | 2- STORM PANELS: | | A) ANCHOR TYPE SPECIFIED FOR STORM | | PANELS IS NOT THE SAME ANCHOR TYPE THAT | | IS USED IN THE PRODUCT APPROVAL. REVISE | | AS REQUIRED. | | B) 2" EDGE DISTANCE REQUIRES ANCHOR | | SPACING TO BE REDUCED USING THE | | MULTIPLIER AS REQUIRED ON TABLE AT | | BOTTOM OF PAGE 9 OF 17 OF STORM PANELS | | DRAWINNG NO 05-284. REVISE ANCHOR | | SPACING AS REQUIRED. | | | | 3- PRODUCT APPROVAL FOR ACCORDION | | SHUTTERS IS NOT LEGIBLE. PROVIDE CLEAR | | AND LEGIBLE DRAWINGS TO BE ABLE TO READ | | DRAWINGS AND CHECK PROPOSED | | INSTALLATION. | | | | 4- WIND LOAD SCHEDULE IS NOT REQUIRED | | FOR BUILDINGS WITH MEAN ROOF HEIGHT OF | | 30'-0" OR LESS. CONTRACTOR MAY USE TABLE | | 1609.6B OF FBC 2004 TO DETERMINE THE | | DESIGN PRESSURES. ON THE OTHER HAND, IF | | SCHEDULE IS SUBMITTED, THEN IT MUST HAVE | | ENGINEER'S ORIGINAL SEAL, SIGNATURE AND | | DATE AS REQUIRED BY CHAPTER 471 FLORIDA | | STATUTES. COPIES ARE NOT ALLOWED | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-11-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-04 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-04 |
Time |
15:35 |
Sent To |
B |
|
Notes |
2006-11-04 15:35:37 | TO "JGOMEZ" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-10-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-16 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-16 |
Time |
15:07 |
Sent To |
B |
|
Notes |
2006-10-16 15:07:47 | TO "JGOMEZ" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-10-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-10-05 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2006-09-23 |
Time |
19:34 |
Sent To |
|
|
Notes |
2006-09-23 00:00:00 | TO "MISC" BOX#1 |
|
|
|