Plan Review Details - Permit 06090691
Plan Review Stops For Permit 06090691 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2006-11-17 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2006-11-17 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2006-11-17 |
Time |
13:05 |
Sent To |
|
|
Notes |
2006-11-17 13:05:33 | TEMPORARY PCN WAS CREATED FOR THIS STRUCTURE .PERMIT | | WAS ASSIGNED TO IT. | | | | LACRAMIOARA URSU | | MIS - GIS SUPPORT SPECIALIST | | E-MAIL:[email protected] | 2006-10-22 19:49:37 | NEEDS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-04-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-04-20 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-04-20 |
Time |
08:42 |
Sent To |
|
|
Notes |
2007-04-20 10:09:14 | ***PROVISOS*** | | SAMANTHA M. HILL, BUILDING PLANS EXAMINER 561-805-6724 | | [email protected] | | | | 1.)A CO HOLD HAS BEEN PLACED ON THIS PERMIT.THE | | ATTORNEYS FOR VP BUILDINGS AND THE ENGINEER DISPUTE THE | | REQUIREMENT BY FBPE (JOHN RYANS) THAT A CERTIFICATE OF | | AUTHORIZATION PER FS471.023 IS REQUIRED FOR VP | | BUILDINGS (LETTER IN THE FILE).THE ENGINEER HAS | | SIGNED, SEALED, AND DATED THE STRUCTURAL PLAN FOR THE | | VP BUILDING AS AN INDIVIDUAL, REMOVING THE COMPANY FROM | | THE PLAN.PRIOR TO CO, ONE OF THE FOLLOWING MUST | | OCCUR: | | | | A.DOCUMENTATION FROM FBPE CONFIRMING THAT | | CERTIFICATE OF AUTHORIZATION IS NOT REQUIRED FOR VP | | BUILDINGS, AKA VARCO PRUDEN BUILDINGS, OR | | | | B.CERTIFICATE OF AUTHORIZATION OBTAINED FOR VP | | BUILDINGS FROM FBPE, AND STRUCTURAL PLAN ON FILE WITH | | THE CITY REVISED TO INCLUDE THAT NUMBER. | | | | 2.)SUBMIT LIGHTING POLE CALCS WITH CORRECT ASCE 7-02 | | REFERENCE, FBC35. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-04-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-04-04 |
Time |
07:05 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-04-04 |
Time |
05:11 |
Sent To |
|
|
Notes |
2007-04-04 07:10:33 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | CODE | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | FLORIDA ADMINISTRATIVE CODE | | FSFLORIDA STATUTE | | | | 1.)N/A. | | | | 2.)VP BUILDINGS SHEETS, SEE FIRST CORRECTION LIST IN | | REGARDS TO ALL INFORMATION REQUIRED BY FAC61G15-23.002. | | I BELIEVE THAT THE ENGINEER HAS ADDRESSED THE ISSUE OF | | CERTIFICATE OF AUTHORIZATION FOR PRACTICING ENGINEERING | | THROUGH A COMPANY VERBALLY.PLEASE HAVE HIM ADDRESS | | THIS ISSUE WITH A LETTER FOR THE FILE. | | | | 3.)S2.1, PROVIDE CALCULATIONS FOR ROOF COMPONENTS & | | CLADDING, CORNER ZONE, <10SF, -69PSF.SEE FBC TABLE | | 1609.6.2.1(2), ROOF 0 TO 27 DEGREES. | | | | 4.)PROVIDE THE INSTALLATION INSTRUCTIONS, ERECTION | | GUIDE, EVALUATION REPORT FOR THE VP BUILDINGS ROOF. | | CONFIRM THAT THIS PRODUCT MEETS OR EXCEEDS DESIGN | | PRESSURES REQUIRED BY EITHER SHEET S2.1 (WITH | | CALCULATIONS) OR REVISED SHEET S2.1. | | | | 5.)N/A |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-01-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-01-09 |
Time |
12:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-01-08 |
Time |
13:44 |
Sent To |
|
|
Notes |
2007-01-09 12:05:41 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | 1.)A NOTICE OF COMMENCEMENT WILL BE REQUIRED PRIOR TO | | PERMIT PICKUP, FS713.13. | | | | 2.)IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY | | PRIOR TO PERMIT ISSUANCE, 2300 N JOG RD.PLEASE CALL | | 561-233-5025 FOR MORE INFORMATION. | | | | THE PLANS MUST BE STAMPED.ONLY A RECEIPT WAS | | PROVIDED.PLEASE NOTE THAT THE STAMPED PLAN WHICH YOU | | PROVIDED IS WITH THE DENIED FOUNDATION PERMIT | | APPLICATION PACKAGE.WE MUST HAVE A COPY ON FILE PRIOR | | TO PERMIT ISSUANCE. | | | | 3.-4.)ADDRESSED. | | | | 5.)PLEASE REVISE THE PERMIT APPLICATION TO REFLECT | | THE CORRECT TEMPORARY PARCEL ID. | | | | 6.-8.)ADDRESSED. | | | | 9.)PROVIDE COMPONENTS & CLADDING PRESSURES, | | FBC1603.1.4. | | | | NOT ADDRESSED.THE RESPONSE LETTER STATES THAT IT IS | | PROVIDED BY VP.VP PLAN STATES THAT ALL COMPONENTS & | | CLADDING HAVE BEEN DESIGNED BY A FLORIDA DESIGN | | PROFESSIONAL AND ARE NOT ON THE PLAN PER FBC | | 1606.1.7(5).THIS IS NOT A VALID CODE SECTION, AND IS | | REQUIRED ON THE PLAN, WIND DESIGN CRITERIA, | | FBC1063.1.4. | | | | DESIGNER IS TO SPECIFY COMPONENT & CLADDING PRESSURES, | | PER OPENING AND FOR THE ROOF SYSTEMS.PRODUCT | | APPROVALS ARE THEN VERIFIED FOR COMPLIANCE. | | | | 10.)ADDRESSED. | | | | 11.)THE RESPONSE REGARDING S2 OCCUPANCY IS | | ACKNOWLEDGED.THIS IS ACCEPTABLE WITH THE EXCEPTION OF | | UNLIMITED TRAVEL DISTANCE FOR ACCESSIBLE EXITS.NOTE | | THAT THE TRAVEL DISTANCE FOR THE TWO ACCESSIBLE EXITS | | ARE APPROXIMATELY 350 AND 450 FEET, BUT OTHER EXITS | | HAVE LESS TRAVEL DISTANCE.PLEASE CONTACT ME TO | | DISCUSS PRIOR TO RESUBMITTAL. | | | | 12.)IF NECESSARY, REVISE TRAVEL DISTANCE, OCCUPANT | | LOAD, ANY OTHER ITEMS AFFECTED BY ITEM 11. | | | | 13.)ADDRESSED.PLEASE SEE ITEM 11 ABOVE. | | | | 14.)3-A9.2, PROVIDE A GUARD DETAIL IN COMPLIANCE WITH | | FBC1012 AND FBC1607.7. | | | | PLEASE INCLUDE REQUIREMENT OF 1607.7.1.1. | | | | 15.)2-A9.2, THE HANDRAIL EXTENSIONS ARE TO COMPLY | | WITH FBC1009.11.5.ANY ACCESSIBLE STAIRS ARE TO ALSO | | COMPLY WITH FBC11-4.9.4. | | | | IT IS NOT CLEAR WHY THE STAIRS AT THE LOADING DOCK ARE | | NOT ACCESSIBLE.THE EXCEPTIONS TO ACCESSIBILITY DO NOT | | APPLY.PLEASE REVISE HANDRAIL DETAILS.ALSO SEE | | FBC1009.3.2, STAIR TREADS TO BE SOLID. | | | | 16.)ADDRESSED. | | | | 17-18.) SEE ITEM 11. | | | | 19-21.)ADDRESSED. | | | | 22.)SUBMIT THREE ORIGINAL ENERGY CALCS (ONLY ONE | | PROVIDED). | | | | 23-24.) ADDRESSED. | | | | 25.)FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED | | IN ADDITION TO THE NOA SUBMITTED, FAC9B72. | | WWW.FLORIDABUILDING.ORG FOR MORE INFORMATION. | | | | ANY PRODUCT APPROVALS NOT SUBMITTED AND REVIEWED PRIOR | | TO PERMIT ISSUANCE WILL REQUIRE SEPARATE PERMITS. | | | | REGARDING THE PRODUCT APPROVALS SUBMITTED, NOTE THE | | FOLLOWING: | | | | A. ONLY ONE SET SUBMITTED; THREE REQUIRED. | | | | B. TWO PRODUCT APPROVALS WERE REVIEWED BY DOR, TWO WERE | | NOT.ALL ARE REQUIRED TO BE REVIEWED AND APPROVED BY | | DESIGNER OF RECORD, FBC*106.3.3. | | | | C. THE VP FLORIDA STATE PRODUCT APPROVAL IS DENIED. | | PROVIDE PRODUCT APPROVALS FOR THE ROOF SYSTEMS.IF A | | MIAMIDADE NOA IS AVAILABLE, A LOCAL.PRODUCT APPROVAL | | CAN BE ISSUED USING THE NOA.IF IT IS NOT AVAILABLE, | | SEE FAC9B72 IN REGARDS TO REQUIREMENTS FOR A LOCAL | | PRODUCT APPROVAL APPLICATION.IF MORE THAN ONE | | FASTENING OPTION IS AVAILABLE, INDICATE WHICH SYSTEM OR | | FASTENING WILL BE USED SO THAT CODE COMPLIANCE CAN BE | | DETERMINED. | | | | D. PRODUCT APPROVAL REQUIRED FOR THE WALL LOUVERS. | | | | 26.)ENGINEERING FOR VP BUILDINGS, DECLARE GOVERNING | | CODE. | | | | GOVERNING CODE IS FBC2004.PLANS STATE ASCE7-02 AND | | CITES CODE REFERENCES FROM FBC2001.PLEASE REVISE; | | DESIGN IS TO BE IN COMPLIANCE WITH FBC2004. | | | | 27-31.) ADDRESSED. | | | | NEW COMMENTS: | | | | 32.)FIRE SPRINKLER PLANS, FP1 AND FP2, ARE LISTED ON | | THE COVER SHEET BUT ARE NO LONGER IN THE PLANS.THIS | | IS A STATUTORY REQUIREMENT, PLEASE PROVIDE. | | | | 33.)SEE ATTACHED FS553.80(2)(B). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-10-24 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-10-23 |
Time |
17:48 |
Sent To |
|
|
Notes |
2006-10-19 15:23:29 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | 1.)A NOTICE OF COMMENCEMENT WILL BE REQUIRED PRIOR TO | | PERMIT PICKUP, FS713.13. | | 2.)IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY | | PRIOR TO PERMIT ISSUANCE, 2300 N JOG RD.PLEASE CALL | | 561-233-5025 FOR MORE INFORMATION. | | | | 3.)THE COPY OF THE PLAT PROVIDED IS NOT RECORDED. | | PLEASE ADVISE AS TO STATUS.IF THIS IS RECORDED, | | PROVIDE PLAT FILING INFORMATION (BOOK/PAGE). | | | | 4.)THE PLAT PROVIDED AND THE PROPOSED PLAT LINES ON | | THE OVERALL SITE PLAN PREPARED BY BOWYER SINGLETON DO | | NOT MATCH.FOR INSTANCE, THE CIRCULAR SECTION AT THE | | END OF THE ROAD (PARCEL G) DOES NOT APPEAR ON THE | | OVERALL SITE PLAN.THE PLAT LINES ARE INCOMPLETE ON | | THE OVERALL SITE PLAN. | | | | 5.)THE APPLICATION REFERS TO TWO DIFFERENT PARCEL ID | | NUMBERS.YOU CANNOT CROSS PROPERTY LINES.PROVIDE | | INFORMATION IN REGARDS TO THE LOCATION OF THE TWO | | PARCELS, ENDING IN 3010 AND 3040.OUR GIS RECORDS | | SHOWS 3010 AS A VERY SMALL PARCEL (POSSIBLY A ROAD) | | GOING THROUGH THE MIDDLE OF THE LARGER PARCEL, 3040. | | PLEASE CONTACT ME TO DISCUSS IF YOU ARE UNSURE AS TO | | HOW TO GET THIS MATTERS RESOLVED. | | | | 6.) FBC* 109.3.7RESIDENT INSPECTOR. SUBMIT INSPECTOR | | RESUME' AND LICENSE DOCUMENTS TO HAROLD PISKURA, | | DIRECTOR OF THE RESIDENT INSPECTOR PROGRAM.A RESIDENT | | INSPECTOR PROGRAM IS REQUIRED, ON THIS PROJECT, DUE TO | | ONE OR MORE OF THE FOLLOWING: | | - BUILDINGS/ADDITIONS OF TYPE I OR II | | CONSTRUCTION | | - ANY MAJOR STRUCTURAL ALTERATIONS | | - STRUCTURES IN WHICH THE CONCRETE | | DESIGN IS BASED ON COMPRESSIVE | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | - PILE DRIVING | | - BUILDINGS OVER 20,000 SQFT IN AREA | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | - BUILDING/STRUCTURES OF UNUSUAL DESIGN OR METHODS | | OF CONSTRUCTION | | | | ALSO, PLEASE ARRANGE WITH HAROLD PISKURA (INSPECTION | | SERVICES MANAGER - TEL: | | 561 805 6711), A MEETING INVOLVING THE OWNER, RESIDENT | | INSPECTOR, JOB INSPECTOR, CONTRACTOR AND ENGINEER. THIS | | MUST BE DONE PRIOR TO PERMIT ISSUANCE.THREE ORIGINAL | | SETS OF ALL DOCUMENTS ARE REQUIRED FOR PERMITTING. | | | | 7.)VALUATION ADJUSTMENT DONE USING BUILDING VALUATION | | DATA FROM THE ICC WEBSITE, SEE ATTACHED BILL. | | | | 8.)RADON FEES DUE, FS553.721.SEE ATTACHED BILL. | | | | 9.)PROVIDE COMPONENTS & CLADDING PRESSURES, | | FBC1603.1.4. | | | | 10.)THE ACCESSIBLE ROUTE FROM THE PUBLIC WAY IS SHOWN | | ON THE OVERALL SITE PLAN, SHOW SLOPE AND WIDTH | | FBC11-4.1.2(1). | | | | 11.)S2 DECLARED, SEE FBC311.3, DEFINITION IS FOR | | NON-COMBUSTIBLE STORAGE.PROVIDE INFORMATION IN | | REGARDS TO WHAT WILL BE STORED AND WHAT ACTIVITY WILL | | TAKE PLACE IN THIS BUILDING.HOW WILL YOU CONTROL THE | | SHIPPING OF COMBUSTIBLES SUCH AS PAPER AND BOOKS?NOTE | | THAT PACKAGING MUST BE ADDRESSED AS WELL AS THE ITEMS | | STORED. | | | | 12.)IF NECESSARY, REVISE TRAVEL DISTANCE, OCCUPANT | | LOAD, ANY OTHER ITEMS AFFECTED BY ITEM 11. | | | | 13.)PROVIDE A LIFE SAFETY PLAN, FBC*106.3.5.1.1(6) | | AND (7).INCLUDE THE FOLLOWING: | | EGRESS CAPACITIES, FBC1005. | | INDICATE ACCESSIBLE EXITS FBC11-4.1.3(9) | | ANY OTHER INFORMATION REQUIRED TO DETERMINE CODE | | COMPLIANCE | | | | 14.)3-A9.2, PROVIDE A GUARD DETAIL IN COMPLIANCE WITH | | FBC1012 AND FBC1607.7. | | 15.)2-A9.2, THE HANDRAIL EXTENSIONS ARE TO COMPLY | | WITH FBC1009.11.5.ANY ACCESSIBLE STAIRS ARE TO ALSO | | COMPLY WITH FBC11-4.9.4. | | | | 16.)SEE FBC11-4.1.3(8)(III), WHERE FEASIBLE, | | ACCESSIBLE ENTRANCES SHALL BE THE ENTRANCES USED BY THE | | MAJORITY OF PEOPLE VISITING OR WORKING IN THE BUILDING. | | IT IS NOT CLEAR IF THE WAREHOUSE ENTRY IS ACCESSIBLE. | | | | 17.)FBC11-4.1.3(9), ACCESSIBLE MEANS OF EGRESS SHALL | | BE PROVIDED IN THE SAME NUMBER AS REQUIRED FOR EXITS BY | | LOCAL BUILDING/LIFE SAFETY REGULATIONS; MORE THAN ONE | | EXIT REQUIRED FROM THE STORAGE AREA DUE TO OCCUPANT | | LOAD, FBC10181.2. A RAMP IS SHOWN AT THE BUILDING | | ENTRANCE, NO OTHER ACCESSIBLE EXITS SHOWN.IT IS NOT | | CLEAR IF THE STOOPS SHOWN AT THE DOORS AT GRADE LEVEL | | ARE AT THE SAME ELEVATION AS THE ASPHALT OR IF THEY ARE | | HIGHER.PLEASE CLARIFY ON THE PLAN. | | | | 18.)FBC11-4.1.3(8)(A)(II), ACCESSIBLE ENTRANCES | | REQUIRED AT LEAST EQUIVALENT TO THE NUMBER OF | | ACCESSIBLE EXITS. | | | | 19.)72 INCHES OF STRAIGHT AND LEVEL CLEARANCE | | REQUIRED AT THE BOTTOM OF THE RAMP, FBC11-4.8.4(2). | | | | 20.)A3.1 DOES NOT SHOW AN ELEVATION CHANGE INSIDE OF | | THE BUILDING, BUT THE ELEVATIONS ON A2.1 SHOW A RAMP TO | | THE EAST DOOR, SOUTH ELEVATION, BUT THE OTHER DOOR IS | | SET AT GRADE.PLEASE CLARIFY. | | | | 21.)SPECIFY INTERIOR FINISH CLASSIFICATION, FBC TABLE | | 803.5. | | | | 22.)ENERGY CALCS REQUIRED.WHEN SUBMITTING, SIGN THE | | OWNER/AGENT LINE OF THE ENERGY CALC, VERIFY THAT SF | | AREA ON THE ENERGY CALC MATCHES THE SF ON THE PLAN, AND | | INCLUDE CORRECT JURISDICTION CITY OF WEST PALM BEACH, | | 604700. | | | | 23.)IMPACT PROTECTION REQUIRED.NONIMPACT STOREFRONT | | PRODUCT APPROVALS WERE SUBMITTED.SEE ATTACHED POLICY, | | ITEM 13, IN REGARDS TO IMPACT PROTECTION ON COMMERCIAL | | BUILDINGS.USE IF REMOVABLE SHUTTERS ON COMMERCIAL | | BUILDINGS MUST BE APPROVED BY THE BUILDING OFFICIAL. | | | | | | 24.)IF YOU ARE USING HURRICANE SHUTTERS, SEE ATTACHED | | SCHEDULE FOR INSTALLATION.PROVIDE PRODUCT APPROVALS | | AND ALL REQUIRED INFORMATION TO DETERMINE CODE | | COMPLIANCE. | | | | 25.)FLORIDA STATE OR LOCAL PRODUCT APPROVALS REQUIRED | | IN ADDITION TO THE NOA SUBMITTED, FAC9B72. | | WWW.FLORIDABUILDING.ORG FOR MORE INFORMATION. | | | | 26.)ENGINEERING FOR VP BUILDINGS, DECLARE GOVERNING | | CODE. | | | | 27.)MECHANICAL EQUIPMENT LOADS NOT ADDRESSED ON THE | | VP BUILDING STRUCTURALS. | | | | 28.)THE ENGINEER'S SIGNATURE IS A PHOTOCOPY (VP). SEE | | FAC61G15-23.002. | | | | 29.)ENGINEER'S TITLE BLOCK IS TO COMPLY WITH | | FAC61G15-23.002. | | | | 30.)THE ARCHITECT SPECIFIES IMPACT GLASS, NONIMPACT | | PRODUCT APPROVALS SUBMITTED. | | | | 31.)ROOF DRAINAGE IS TO COMPLY WITH FBC1503.4. | | PROVIDE CALCULATIONS AND DETAILS FOR SCUPPERS AND | | OVERFLOW SCUPPERS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2007-10-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-10-07 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-10-07 |
Time |
09:20 |
Sent To |
PC |
|
Notes |
2007-10-07 09:32:17 | REV'S FOR 4.1 AND 5.1, FOR REV #6 ONLY. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2007-04-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-04-19 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-04-19 |
Time |
09:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2007-03-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-03-18 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-03-18 |
Time |
10:26 |
Sent To |
|
|
Notes |
2007-03-18 10:28:49 | ** UNSAT 3RD REVIEW** | | | | | | 1) NOTE: PLEASE SEE THE METHOD/WHOLE BUILDING SUBMITTED | | DOES NOT CONTAIN ANY *INTERIOR* LIGHTING INPUT DATA? | | PLEASE CLARIFY? | | DOES NOT SHOW ANY ENTERED OR DOES NOT SHOW ANY IN THE | | INPUT DATA REPORT? | | FBC 13-415.1.AB.1.1. | | PLEASE ALSO SEE SHEET 3 OF SUBMITTED CALCULATIONS WHICH | | REQUIRES THE ENGINEER TO SIGN, DATE AND SEAL SHEET. | | THIS IS THE SHEET WHICH CONTAINS THE *CERTIFICATIONS*. | | FBC 13-103.1.1.1 | | | | 2) NOTE: PLEASE CLARIFY HOW THE PLANS WHICH WERE | | REVISED AFTER THE MEETING WHICH WAS HELD ON 2/26/07 ARE | | DATED BY THE ENGINEER ON 2/2/07? | | FS 471.025 AND FAC 61G15-23.002 REQUIRES THE ENGINEER | | TO SIGN, AND DATE PLANS WHEN THEY ARE SEALED. THE | | REVISION DATE EVEN INDICATES A DATE OF 2/2/07 WHICH IS | | NOT POSSIBLE AS THESE WERE NEW SHEETS ENTERED INTO THE | | SETS ON 3/15/07. | | | | 3) NOTE: PLEASE SEE BATHROOM AREAS IN FRONT ARE MISSING | | LIGHTING CONTROLS PER 13-415.1.ABC.1.2. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | 2007-03-18 09:39:44 | 2007-03-18 09:39:44 | | NEW SHEETS AND PLANS SUBMITTED ON 3/15/07. | 2007-03-08 16:11:27 | 2007-03-08 16:11:27 | | PLANS ON HOLD FOR REVIEW. 3/8/07 | | NEW CORRECTIONS WHICH WERE REQUIRED TO BE SUBMITTED BY | | MARCH 1ST HAVE NOT BEEN BROUGHT IN. AT THE REQUEST FROM | | MARK PARKHIL BY E-MAIL, PLANS ARE NOT TO BE REVIEWED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2007-01-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-01-12 |
Time |
17:10 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-01-12 |
Time |
12:03 |
Sent To |
|
|
Notes |
2007-01-12 17:10:50 | *****UNSAT 2ND REVIEW ****** | | | | FED-EX GROUND. | | | | ** PLEASE ADDRESSING ON PLANS SHALL BE REQUIRED TO | | CORRELATE. PLEASE SEE PERMIT APPLICATION, THE ASSIGNED | | ADDRESS AND PLANS DO NOT MATCH. PLEASE SEE THE ADDRESS | | SHALL APPEAR ON ALL SHEETS TITLE BLOCKS. FAC 61G1, | | 61G15 | | | | ** PLEASE SEE SOME COMMENTS FROM THE PREVIOUS REVIEWS | | WHICH ARE STILL IN NEED OF ADDRESSING. | | COMMENTS WILL BE IDENTIFIED AS FOLLOWS IN THE SAME | | NUMERICAL ORDER FROM THE PREVIOUS REVIEW. ANY NEW NOTES | | WILL BE ADDED TO THE END OF THE REVIEW. | | | | A) NO, MEANS THE COMMENT IS STILL IN NEED OF FURTHER OR | | CORRECTED INFORMATION. IT WILL BE FOLLOWED BY FURTHER | | EXPLANATION FOR MORE INFORMATION OR TO TRY AND BETTER | | EXPLAIN THE COMMENT. | | B) OK, IS COMMENT IS ADDRESSED AND THE PREVIOUS NOTE | | WILL BE REMOVED. | | C) NO/OK IS THAT PART OF THE COMMENT MAY HAVE BEEN | | ADDRESSED BUT NOT ALL. A FURTHER EXPLANATION WILL BE | | TYPED TO PROVIDE MORE INFORMATION FOR WHAT IS NEED. | | | | | | 1) NOTE:NO, PLEASE SEE THERE ARE NUMEROUS SHEETS IN | | ONE SET WHICH ARE NOT SIGNED, DATED OR SEALED AT ALL. | | PLEASE SEE YET ANOTHER SET ONLY CONTAINS ONE ELECTRICAL | | SHEET WHICH IS SIGNED, DATED AND SEALED.PLEASE SEE | | THE THIRD SETS ALSO. | | PLEASE SEE THE SAME SETS CONTAINS MANY MECHANICAL AND | | PLUMBING SHEETS WHICH ARE NOT SIGNED, DATED OR SEALED | | EITHER? | | PLEASE SEE OTHER SETS WHICH SOME SHEETS ARE SIGNED, | | DATED AND SEALED AND MANY OTHER SHEETS ARE NOT? | | PLEASE SEE OTHER DOCUMENTS WHICH ARE IN FACT | | PHOTO-COPIES OF SIGNED AND SEALED DOCUMENTS. | | AS PREVIOUSLY MENTIONED, ALL THREE SETS, ALL DOCUMENTS | | PREPARED BY THE DESIGNERS OF RECORD ARE REQUIRED TO | | CONTAIN AN ORIGINAL SIGNATURE, DATED AND A RAISED | | EMBOSSED SEALED AS REQUIRED IN THE SECTIONS OF THE | | FLORIDA ADMINISTRATIVE CODE AND FLORIDA STATUTES GIVEN | | ON PREVIOUS REVIEW. | | ** PLEASE KNOW, SETS OF PLANS MAY BE RETAINED BY THIS | | OFFICE. | | ** PLEASE ALSO KNOW THAT THIS COMMENT IS REQUIRED FOR | | ALL TRADES AND FOR ALL SHEETS WHETHER OR NOT COMMENT IS | | MADE BY ANY OTHER REVIEWER(S). | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE ALL MEP SHEETS SHALL CONTAIN THE RAISED | | EMBOSSED SEAL FOR THE ENGINEER OF RECORD. PLEASE SEE | | FAC 61G15-23.001,FS 471.025 | | PLEASE ALSO SEE THE SEAL WHICH IS BEING INDICATED ON | | SAID MEP'S IS NO LONGER VALID WITH THE STATE OF | | FLORIDA. PLEASE SEE FAC 61G15-23.001, WHICH PASSED A | | RULING IN FEB 04" WHICH REQUIRED THE SEAL WORDING TO | | CHANGE FROM "CERTIFICATE" TO "LICENSE". PLEASE KNOW AN | | EXTENSION WAS GIVEN TO 12/31/05. | | | | 2) NOTE: OK. | | | | 3) NOTE: NO, THIS IS STILL REQUIRED AND IT HAS COME TO | | OUR ATTENTION THAT THE FIRM DOES NOT CONTAIN THE | | LICENSE NUMBER AS NEEDED AND AS REQUIRED PER SECTIONS | | GIVEN BELOW IN THE PREVIOUS REVIEW. PLEASE SEE RESPONSE | | MENTIONS THE ENGINEER WAS ADDED TO THE TITLE BLOCKS, | | HOWEVER THIS IS NOT THE ONLY REQUIRED INFORMATION. | | PLEASE ALSO KNOW THAT EVEN THOUGH THE ENGINEERING FIRM | | AS SHOWN IS LOCATED OUT OF STATE, THIS HAS NO BEARING | | ON THE REQUIREMENT. | | ** THE TITLE BLOCKS WERE REVISED FOR THE FOUNDATION | | PERMIT. IF THIS IS DONE, ADDRESS AND COMPLETED | | INFORMATION FOR THE INDIVIDUAL ENGINEER OF EACH TRADE | | IS REQUIRED TO BE COMPLETED. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE MISSING REQUIRED INFORMATION ON TITLE | | BLOCKS. PLEASE SEE MISSING THE PRINTED LICENSE # OF | | ARCHITECT ON A SHEETS. PLEASE SEE THE MISSING | | INFORMATION AS REQUIRED ON ENGINEERING FIRM. PLEASE SEE | | MISSING CERTIFICATE OF AUTHORIZATION NUMBER. PLEASE SEE | | ALL TITLE BLOCKS FOR ALL SHEETS ARE REQUIRED TO MEET | | FAC 61G1-16.004, 61G15-23.002 AND FS 481.219, 471.023. | | ** REQUIRED FOR ALL WHETHER OR NOT COMMENT IS MADE BY | | OTHER REVIEWER(S). | | | | 4) NOTE: OK. | | | | 5) NOTE: NO, PLEASE SEE THE ENERGY CALCULATIONS | | SUBMITTED DO NOT COMPLY OR SUPPLY THE INFORMATION AS | | NEEDED UNDER 13-415.1AB.1 OR 13-415.2. PLEASE SEE THE | | SHEETS SUBMITTED, SOME ARE SIGNED AND SEALED AND SOME | | ARE NOT. | | PLEASE SEE LIGHTING PERFORMANCE ON PLANS INDICATES THE | | 2003 ICC WHICH IS NOT ADOPTED INTO THE STATE OF | | FLORIDA. | | PLEASE ALSO SEE THE ENTIRE BUILDING IS BEING DESIGNATED | | AS ONE USE? | | PLEASE SEE THE PREVIOUS NOTE AS THE COMPLIANCE | | BREAKDOWN REQUIRED FOR METHOD A SHOULD BE SUBMITTED | | SHOWING ALL INFORMATION AS NEEDED. | | THIS MAY NOT BE CONSIDERED INDUSTRIAL WORK. A CALL TO | | GO OVER USAGE MAY HELP. | | | | **PREVIOUS REVIEW NOTE** | | PLEASE SEE FBC 2004 FOR REQUIRED ENERGY CALCULATIONS. | | PLEASE SEE 1993 ASHAE/ ETC IS BEING REFLECTED ON SAID | | DOCUMENTS. PLEASE SEE FBC 2004 CHAPTER 13. | | 13-415.1.AB.1 | | PLEASE KNOW THESE WILL ALSO BE REQUIRED TO BE SIGNED, | | DATED AND SEALED AS REQUIRED ON NOTES ABOVE. PLEASE SEE | | THESE ARE ALSO STAMPED WITH A "RUBBER STAMP" FOR SAID | | SEAL AND CONTAINS "CERTIFICATE" IN SEAL. | | | | 6) NOTE:OK/NO. PLEASE SEE RESPONSE LETTER MENTIONS | | THAT THE ENTIRE BUILDING WILL BE OPERATING 24/7. THIS | | EXCEPTION SHALL BE NOTED AND STATED ON THE PLANS. | | PLEASE SEE NO INFORMATION FOR THE WORST CASE VOLTAGE | | DROP CALCULATIONS OR SCENARIOS COULD BE LOCATED ON | | PLANS. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE CHAPTER 13 13-415.1.ABC.1.1, .1.2 AND .1.3 | | FOR MINIMUM LIGHTING CONTROLS REQUIRED. PLEASE PROVIDE | | PERFORMANCE CALCULATIONS PER 13-415.2, 13-415.2.ABC.1. | | PLEASE SEE TABLES AND SPACE BY SPACE METHODS. | | PLEASE PROVIDE SCHEDULING. | | PLEASE SEE ALL OF CHAPTER 13, BASED ON THE 2004 FBC. | | PLEASE PROVIDE ALL WORST CASE SCENARIO'S FOR VOLTAGE | | DROP CALCULATIONS PER13-413.1ABC.1 FOR BOTH BRANCH | | CIRCUIT AND FEEDERS. | | | | 7) NOTE:NO, THE ATTACHED DOCUMENTS DO NOT PROVIDE THE | | WIND LOAD INFORMATION, DO NOT SUPPLE THE MAXIMUM EPA, | | AND IF SUBMITTING SHOP/PRODUCTS, FOR COMPLIANCE AND | | SHOWING AND STATING THE INFORMATION ON PLANS, THEN ALL | | OF THESE DOCUMENTS FOR POLES, WIND LOAD INFORMATION AND | | EPA'S SHALL BE REVIEWED AND STAMPED/SIGNED BY THE | | ENGINEER OF RECORD. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE PROVIDE WIND LOAD CALCULATIONS FOR SITE LIGHTING | | POLES. PLEASE KNOW, THE BUILDING/STRUCTURAL REVIEWER | | WILL REVIEW SAID DOCUMENTS FOR ACTUAL WIND LOADS WHICH | | WILL BE REQUIRED TO SHOW EPA FOR PROPOSED FIXTURES. | | FBC 2004 140MPH. ETC. | | | | 8) NOTE:NO, PLEASE SEE RESPONSE MENTIONS DESIGN WILL | | MEET THIS; HOWEVER NO REVIEW FOR COMPLIANCE CAN BE DONE | | UNTIL PHOTO-METRICS ARE SHOWN FOR COMPLIANCE. THE | | LEVELS ARE BEING SUBMITTED FOR WAREHOUSE UNDER NORMAL, | | HOWEVER NO INFORMATION FOR CONDITIONS UNDER EMERGENCY | | OR OFFICE EGRESS AREAS IS SHOWN. | | | | ** PREVIOUS REVIEW NOTE** | | PLEASE PROVIDE MINIMUM PHOTO-METRICS FOR EGRESS | | LIGHTING PER NFPA-101 7.8, 7.9 | | PLEASE SEE NORMAL IS SHOWN, HOWEVER NEED TO SEE MIN | | UNDER EMERGENCY CONDITIONS. | | | | 9) NOTE: OK, AS NOTED HOWEVER SEE OTHER NEW COMMENTS AS | | THE PLANS WERE REVIEWED AS THIS MAIN DIST PANEL | | CONTAINING A SINGLE MCB RATED AT THE 1600AMPS. | | SEE NEW NOTES. | | | | 10) NOTE: OK. | | | | 11) NOTE: PLEASE SEE 110.9, 240.13 AND PROVIDE ALL | | MINIMUM REQUIRED AIC RATINGS AND SELECTIVE COORDINATION | | FOR EQUIPMENT AS SHOWN. PLEASE SHOW DETAIL FOR | | EQUIPMENT. | | | | 12) NOTE: NO, PLEASE SEE RESPONSE SAYS THE EGC IS | | AFTER; HOWEVER PLEASE SEE RISER NOTE WHICH SHOWS ALL | | PHASE CONDUCTORS AND AN EGC FROM THE FPL(LOCAL POWER | | COMPANY ) TRANSFORMER. | | PLEASE SEE RISER. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE 250.6, 250.24B AS AN "EQUIPMENT GROUNDING | | CONDUCTOR" IS BEING SHOWN BEFORE THE FIRST MEANS OF | | DISCONNECT ON THE LINE SIDE OF THE MAIN. PLEASE KNOW | | THE EGC IS ONLY INSTALLED AFTER THE FIRST MEANS OF | | DISCONNECT. | | | | 13) NOTE: OK. | | | | 14) NOTE: NO, RESPONSE MENTIONS WHAT TO DO, HOWEVER | | WHERE IS THIS DETAIL ON PLANS AS PREVIOUSLY REQUESTED? | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE PROVIDE A STRUCTURAL SUPPORT DETAIL FOR BOTH | | TRANSFORMERS. | | PLEASE KNOW THIS STRUCTURAL DETAIL WILL BE REVIEWED BY | | BUILDING REVIEWER. | | FBC 106.1.2 | | | | 15) NOTE: OK. | | | | 16) NOTE:NO. PLEASE SEE RESPONSE MENTIONS THE MINIMUM | | LEVELS WHICH ARE REQUIRED PER ADA UNDER THE FBC AS | | EXCESSIVE. THESE ARE MINIMUM LEVELS. PLEASE SEE THE FBC | | DICTATES THE LEVELS WHICH ARE MORE RESTRICTIVE THAN | | THAT OF THE LEVELS IN NFPA-72. PLEASE SEE THAT THERE | | ARE MAXIMUM LEVELS WHICH ARE 1000 CD. | | THE LEVELS FOR THESE AREAS WHICH ARE TAKEN DIRECTLY | | FROM THE SECTIONS GIVEN MUST MEET THESE LEVELS AT A | | MINIMUM. | | AS REVIEWING THE RESPONSE IT HAS BEEN NOTED, HOWEVER | | THESE ARE STATED IN THE CODE THERE IS NO MENTION FOR | | EXCEPTIONS DUE TO MEDICAL CONDITIONS AS MENTIONED. | | PLEASE PROVIDE MORE INFORMATION FOR THESE LEVELS FROM | | THE FBC IF SECTIONS WRE INF THE CODE WHICH WILL SUPPORT | | THESE LESSER LEVELS. | | | | ** PREVIOUS REVIEW NOTES** | | PLEASE SEE FBC 11-4.28, 11-4.28.2 AND .3(4) WHICH | | REQUIRE A MIN OF 75 CANDELAS AT ALL AREAS AS STATED FOR | | ADA. PLEASE SEE MIN LEVELS STATED FOR ADA ON PLANS | | MENTIONS 15CD? | | PLEASE KNOW ALL OF THESE AREAS WILL BE TESTED FOR | | MINIMUM LEVELS, PLEASE BE SURE THE DEVICES AS SHOWN AND | | INSTALLED WILL MEET TESTED LEVELS. PLEASE ADJUST NOTES | | ON PLANS AT THIS TIME. | | | | 17) NOTE: OK. | | | | 18) NOTE: OK/NO, PLEASE SEE RESPONSE MENTIONS THAT ALL | | CONVEYOR SYSTEMS AND ELECTRICAL WORK WILL BE UNDER A | | SEPARATE PERMIT PLANS AND FEES. PLEASE SEE THE MDP | | SHOWS CONDUCTORS AND CONDUITS BEING INSTALLED AT THIS | | TIME YET THE RISER DOES NOT SHOW THESE CONDUITS BEING | | DONE AT THIS TIME. PLEASE ALSO SEE NEW NOTE WITH | | RESPECT TO THE AMOUNT OF MAINS. | | PLEASE ADJUST MDP IF THIS WORK IS NOT BEING DONE AT | | THIS TIME AS SHOWN ON RISER AS FUTURE. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE PROVIDE INFORMATION FOR CONVEYOR SYSTEM, PLEASE | | PROVIDE INFORMATION ON ALL LISTINGS FOR EQUIPMENT BRING | | INSTALLED. | | PLEASE PROVIDE SPECS ON THE MCC. | | 110.3, 90.7. | | FBC 106.1.2 | | | | 19) NOTE: OK. | | | | 20) NOTE:OK, THIS WAS ONLY NOTED A | | | | 21) NOTE: NO, PLEASE SEE RESPONSE MENTIONS THAT THE | | LOCK ON/OFF DEVICE WILL PART OF THE BREAKER, HOWEVER | | THIS IS ONLY BEING NOTED IN RESPONSE LETTER, PLEASE | | PLACE THIS NOTE ON PLANS RELEVANT TO THE PANEL | | SCHEDULES AND BREAKERS BEING INSTALLED. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE PANEL NOTES MENTIONS "LOCK-OFF" BREAKERS, | | PLEASE KNOW THESE TYPE OF LOCK OFF DEVICES SHALL BE AN | | INTEGRAL PART OF THE BREAKER AND SHALL NOT BE REMOVABLE | | WITHOUT THE REMOVAL OF SAID BREAKER. 90.7, 110.3, 90.4 | | | | 22) NOTE: OK, FUELING STATION WILL NOT BE PART OF THIS | | PERMIT. | | | | ** NEW NOTES THIS REVIEW ** | | | | 23) NOTE: PLEASE SEE AS THE MDP CONTAINS MORE THAN SIX | | SPACES AND THEY ARE NOT BEING COMPLETED AND SPACES ARE | | NOT FILLED AT THIS TIME, A MCB WILL BE REQUIRED. OTHER | | OPTIONS WOULD BE TO INSTALL THE 3-POLE BREAKERS AS | | SPARES AT THIS TIME AND WILL BE REQUIRED TO BE SHOWN, | | OR THE PLANS SHALL BE NOTED THAT THE DEAD-FRONT FROM | | THE MANUFACTURE SHALL CONTAIN A PERMANENT FACTORY | | INSTALLED FILLER FOR THIS SECTION FOR 2D. | | 230.70, 230.71 90.4. | | PLEASE KNOW, THE OTHER OPTION WOULD BE TO INSTALL A | | 1600AMP MCB WITH GF PROTECTION. | | | | 24) NOTE: PLEASE SEE MDP WHICH SHOWS 1/0'S FOR THE | | FEEDERS TO THE TRANSFORMER FOR PP1, HOWEVER RISER SHOWS | | #1'S. PLEASE CORRELATE. | | PLEASE KEEP IN MIND THE VOLTAGE DROP AS PREVIOUSLY | | NOTED. | | | | 25) NOTE: PLEASE SEE FLORIDA STATUTES 553.80(2)(B) IS | | BEING GIVEN AS A NOTICE AT THIS TIME WITH RESPECT TO | | REPEAT COMMENTS FOR CODE COMPLIANCE. THIS IS ONLY A | | NOTICE; HOWEVER ONE SET OF PLANS MAY BE RETAINED. | | | | ** PLEASE KNOW AS THERE IS INFORMATION WHICH HAS NOT | | YET BEEN SUBMITTED FOR REVIEW, THERE MAY BE COMMENTS ON | | NEXT REVIEW WHICH ARE NOT STATED IN THESE REVIEW | | NOTES. | | | | | | *** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] ND IF IT IS AN ISSUE THEN RELOCATION | | WILL BE REQUIRED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-10-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-10-23 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-10-22 |
Time |
19:45 |
Sent To |
|
|
Notes |
2006-10-23 14:05:24 | *****UNSAT ****** | | | | FED-EX GROUND. | | | | ** PLEASE ADDRESSING ON PLANS SHALL BE REQUIRED TO | | CORRELATE. PLEASE SEE PERMIT APPLICATION AND PLANS DO | | NOT MATCH WITH THE ADDRESS IN OUR SYSTEM AS SHOWN. | | | | | | 1) NOTE: PLEASE SEE ALL MEP SHEETS SHALL CONTAIN THE | | RAISED EMBOSSED SEAL FOR THE ENGINEER OF RECORD. PLEASE | | SEE FAC 61G15-23.001,FS 471.025 | | PLEASE ALSO SEE THE SEAL WHICH IS BEING INDICATED ON | | SAID MEP'S IS NO LONGER VALID WITH THE STATE OF | | FLORIDA. PLEASE SEE FAC 61G15-23.001, WHICH PASSED A | | RULING IN FEB 04" WHICH REQUIRED THE SEAL WORDING TO | | CHANGE FROM "CERTIFICATE" TO "LICENSE". PLEASE KNOW AN | | EXTENSION WAS GIVEN TO 12/31/05. | | | | 2) NOTE: PLEASE SEE FS 471.025, PLEASE SEE ALL PLANS | | DOCUMENTS ETC ARE REQUIRED TO CONTAIN THE ORIGINAL | | LEGAL SIGNATURE DATE AND SEAL. | | PLEASE SEE "VP" BUILDING SHEETS AS THESE CONTAIN A | | RAISED SEAL OVER "PHOTO-COPIED" SIGNATURE OF THE DESIGN | | PROFESSIONAL. | | PLEASE SEE BUILDING REVIEW COMMENTS AS THESE ARE ALSO | | MISSING THE REQUIRED TITLE BLOCK FOR THESE SHEETS/ | | PLEASE SEE THE ELECTRICAL PLANS APPEAR TO BE SIGNED | | WITH INITIALS? | | IF INDEED THIS IS THE LEGAL SIGNATURE OF THE DESIGN | | PROFESSIONAL PLEASE PROVIDE A SIGNED, DATED, SEALED AND | | NOTARIZED LETTER FOR LEGAL SIGNATURE. | | THIS WILL BE PLACED IN OUR SIGNATURE FILE FOR ANY | | FUTURE REFERENCE AS NEEDED. | | FS 471.025, FAC 61G15-23.002 | | | | 3) NOTE: PLEASE SEE MISSING REQUIRED INFORMATION ON | | TITLE BLOCKS. PLEASE SEE MISSING THE PRINTED LICENSE # | | OF ARCHITECT ON A SHEETS. PLEASE SEE THE MISSING | | INFORMATION AS REQUIRED ON ENGINEERING FIRM. PLEASE SEE | | MISSING CERTIFICATE OF AUTHORIZATION NUMBER. PLEASE SEE | | ALL TITLE BLOCKS FOR ALL SHEETS ARE REQUIRED TO MEET | | FAC 61G1-16.004, 61G15-23.002 AND FS 481.219, 471.023. | | ** REQUIRED FOR ALL WHETHER OR NOT COMMENT IS MADE BY | | OTHER REVIEWER(S). | | | | 4) NOTE: PLEASE SEE ALL OF THE FOLLOWING MINIMUM CODES | | ARE REQUIRED TO BE REFLECTED ON PLANS. 2004 FBC, , 2002 | | NFPA-70, 2002 NFPA-72, 2003 NFPA-101 . | | | | 5) NOTE: PLEASE SEE FBC 2004 FOR REQUIRED ENERGY | | CALCULATIONS. PLEASE SEE 1993 ASHAE/ ETC IS BEING | | REFLECTED ON SAID DOCUMENTS. PLEASE SEE FBC 2004 | | CHAPTER 13. | | 13-415.1.AB.1 | | PLEASE KNOW THESE WILL ALSO BE REQUIRED TO BE SIGNED, | | DATED AND SEALED AS REQUIRED ON NOTES ABOVE. PLEASE SEE | | THESE ARE ALSO STAMPED WITH A "RUBBER STAMP" FOR SAID | | SEAL AND CONTAINS "CERTIFICATE" IN SEAL. | | | | 6) NOTE: PLEASE SEE CHAPTER 13 13-415.1.ABC.1.1, .1.2 | | AND .1.3 FOR MINIMUM LIGHTING CONTROLS REQUIRED. PLEASE | | PROVIDE PERFORMANCE CALCULATIONS PER 13-415.2, | | 13-415.2.ABC.1. PLEASE SEE TABLES AND SPACE BY SPACE | | METHODS. | | PLEASE PROVIDE SCHEDULING. | | PLEASE SEE ALL OF CHAPTER 13, BASED ON THE 2004 FBC. | | PLEASE PROVIDE ALL WORST CASE SCENARIO'S FOR VOLTAGE | | DROP CALCULATIONS PER13-413.1ABC.1 FOR BOTH BRANCH | | CIRCUIT AND FEEDERS. | | | | 7) NOTE: PLEASE PROVIDE WIND LOAD CALCULATIONS FOR SITE | | LIGHTING POLES. PLEASE KNOW, THE BUILDING/STRUCTURAL | | REVIEWER WILL REVIEW SAID DOCUMENTS FOR ACTUAL WIND | | LOADS WHICH WILL BE REQUIRED TO SHOW EPA FOR PROPOSED | | FIXTURES. | | FBC 2004 140MPH. ETC. | | | | 8) NOTE: PLEASE PROVIDE MINIMUM PHOTO-METRICS FOR | | EGRESS LIGHTING PER NFPA-101 7.8, 7.9 | | PLEASE SEE NORMAL IS SHOWN, HOWEVER NEED TO SEE MIN | | UNDER EMERGENCY CONDITIONS. | | | | 9) NOTE: PLEASE INDICATE THE REQUIRED MAIN AND GFP FOR | | THE 1600A MAIN. | | PLEASE SEE 230.70, 240.13 AND 230.95. | | | | 10) PLEASE ALSO SEE POSSIBLE MISPRINT FOR 2B BREAKER | | WHICH IS BEING SHOWN AS 2225A'S.? | | FBC ADMINISTRATIVE SECTION 106.3.5.1.2. | | | | 11) NOTE: PLEASE SEE 110.9, 240.13 AND PROVIDE ALL | | MINIMUM REQUIRED AIC RATINGS AND SELECTIVE COORDINATION | | FOR EQUIPMENT AS SHOWN. PLEASE SHOW DETAIL FOR | | EQUIPMENT. | | | | 12) NOTE: PLEASE SEE 250.6, 250.24B AS AN "EQUIPMENT | | GROUNDING CONDUCTOR" IS BEING SHOWN BEFORE THE FIRST | | MEANS OF DISCONNECT ON THE LINE SIDE OF THE MAIN. | | PLEASE KNOW THE EGC IS ONLY INSTALLED AFTER THE FIRST | | MEANS OF DISCONNECT. | | | | 13) NOTE: PLEASE INDICATE THE FEED-THRU LUGS ON EACH | | LP1 AND PP1, OR ARE THE SECONDARY SECTIONS FED BY OCP | | DEVICES FROM SECTIONS (1). ? | | 240.4,310.16 ETC? | | 106.1.2 FBC ADMIN SECT. | | | | 14) NOTE: PLEASE PROVIDE A STRUCTURAL SUPPORT DETAIL | | FOR BOTH TRANSFORMERS. | | PLEASE KNOW THIS STRUCTURAL DETAIL WILL BE REVIEWED BY | | BUILDING REVIEWER. | | FBC 106.1.2 | | | | 15) NOTE: PLEASE SEE THERE ARE SHEETS WHICH INDICATE | | NOTES, HOWEVER THOSE NOTES ARE ACTUALLY CROSSED OUT ON | | SHEETS FOR NOTES.?? | | PLEASE CLARIFY AND CORRELATE THIS. | | FBC 106.1.2 | | | | 16) NOTE: PLEASE SEE FBC 11-4.28, 11-4.28.2 AND .3(4) | | WHICH REQUIRE A MIN OF 75 CANDELAS AT ALL AREAS AS | | STATED FOR ADA. PLEASE SEE MIN LEVELS STATED FOR ADA ON | | PLANS MENTIONS 15CD? | | PLEASE KNOW ALL OF THESE AREAS WILL BE TESTED FOR | | MINIMUM LEVELS, PLEASE BE SURE THE DEVICES AS SHOWN AND | | INSTALLED WILL MEET TESTED LEVELS. PLEASE ADJUST NOTES | | ON PLANS AT THIS TIME. | | | | 17) NOTE: PLEASE ALSO SEE WITH RESPECT TO THE NOTE #16 | | ABOVE , PLEASE SEE PLANS REFERENCE 2002 BOCA, FOR CODE. | | PLEASE ADJUST. | | 2004 FBC. | | | | 18) NOTE: PLEASE PROVIDE INFORMATION FOR CONVEYOR | | SYSTEM, PLEASE PROVIDE INFORMATION ON ALL LISTINGS FOR | | EQUIPMENT BRING INSTALLED. | | PLEASE PROVIDE SPECS ON THE MCC. | | 110.3, 90.7. | | FBC 106.1.2 | | | | 19) NOTE: PLEASE PROVIDE LOAD CALCULATIONS FOR THE | | MCC1. COULD NOT LOCATE ANY ON PLANS? | | 220.31, LARGEST MOTOR LOADS ETC. | | 215.3, 230.42 | | FBC 106.3.5.1.2 | | | | 20) NOTE: PLEASE SEE POSSIBLE BUILDING FIRE REVIEW | | NOTES AS TRANSFORMER/ AND ELECTRICAL EQUIPMENT APPEAR | | TO BE LOCATED IN AN EGRESS CORRIDOR. PLEASE SEE THIS | | MAY OR MAY NOT BE PERMITTED AS SHOWN? IF THIS IS A | | RATED CORRIDOR, PLEASE KNOW, THIS EQUIPMENT WILL MOST | | LIKELY BE REQUIRED TO BE RELOCATED. | | | | 21) NOTE: PLEASE SEE PANEL NOTES MENTIONS "LOCK-OFF" | | BREAKERS, PLEASE KNOW THESE TYPE OF LOCK OFF DEVICES | | SHALL BE AN INTEGRAL PART OF THE BREAKER AND SHALL NOT | | BE REMOVABLE WITHOUT THE REMOVAL OF SAID BREAKER. 90.7, | | 110.3, 90.4 | | | | 22) NOTE: PLEASE SEE SOME OTHER AREAS INDICATED AS | | "FUTURE" AT THIS TIME MAY AFFECT THE INSTALLATIONS OF | | SOME ELECTRICLA EQUIPMENT AND OTHER EQUIPMENT ON PLANS | | AS SHOWN. PLEASE SEE NEC 500, AND OTHER NFPA'S RELEVANT | | TO ANY OTHER POSSIBLE SCOPE OF WORK WHICH WILL BE | | DECLARED AS HAZARDOUS AT THIS TIME OR AT A LATER TIME. | | | | ** PLEASE KNOW AS THERE IS INFORMATION WHICH HAS NOT | | YET BEEN SUBMITTED FOR REVIEW, THERE MAY BE COMMENTS ON | | NEXT REVIEW WHICH ARE NOT STATED IN THESE REVIEW | | NOTES. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | | | | | | | | | | | | | | 2006-10-23 06:46:18 | REVIEW IN PROGRESS | 2006-10-22 19:46:04 | ONE SET IN ELEC FOR REVIEW. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2007-03-22 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-03-22 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-03-22 |
Time |
13:02 |
Sent To |
|
|
Notes |
2007-03-22 13:07:29 | ACCORDING TO E-MAIL FROM STEVE PAWLYKDATED 2/21/07, | | NO CHANGES WERE MADE AFTER LAST ENG REVIEW.THIS | | E-MAIL IS IN COMPUTER SYSTEM FOR OUR FUTURE | | RECORDS.THEREFORE, ENG REVIEW PASS. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2007-01-26 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2007-01-26 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2007-01-26 |
Time |
10:41 |
Sent To |
|
|
Notes |
2007-01-26 11:01:28 | PLEASE EXPLAIN IN A LETTER EACH OF THE ITEMS BELOW AND | | IN DRAWING REVISION BLOCK,WHAT CHANGES YOU MADE AFTER | | 11/13/06 OUR APPROVAL. | | | | 1. ANY CHANGES IN STANDARDS NOTES OF CITY OF WPB ON | | DRAWINGSFOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, | | PARKING, HANDICAP PARKING, PAINT ? | | 2.ANY CHANGES IN DUMPSTER & ITS ENCLOSURE DETAILS ? | | LOCATION ON DWG, LOCATION MUST BE ACCESSIBLE FOR PICKUP | | TRUCK?. | | 3. ANY CHANGES INFIRST FLOOR ELEVATION, CENTER LINE | | OF ROAD , SIDEWALK ELEVATION?MUST MEET FL BLDG CODE, | | PLEASE SHOW ON THE DRAWINGS. | | 4. ANY CHANGES INSFWMD PERMIT? ANY CHANGES IN GEO | | TECH REPORT? | | 5. ANY CHAGES IN STORM WATER CALCULATIONS, ? ANY | | CHANGES IN PERVIOUS AREA, LIKE GREEN, LAKES, ETC, | | IMPERVIOUS AREA CAL.?, | | 6.ANY CHANGES IN THE SITE AREA, YOU ARE DEVELOPING FOR | | THIS PROJECT ? SO, WE CAN CHECK PERVIOUS, IMPERVIOUS | | CAL. | | 7. ANY CHAGES IN CONNECTTING THE STORM WATER PIPES IN | | YOUR SITE? ITS DETAILS. | | 8. ANY CHANGES IN STORM WATER PIPES AROUND YOUR SITE? | | SO, WE CANSEE THE BEST PIPE TO CONNECT WITH THE STORM | | WATERFROM ALL OTHER STORM WATER PIPES. PLEASE SHOW | | DETAIL OF THE CONTROL STRUCTURES WITH ELEVATIONS, | | NOTCHES, BLEEDING ELEVATION, ETC DID YOU CHANGE | | EXFILTRATION TRENCH ? | | 9.ANY CHAGES INPOLLUTION PREVENTION DETAILS,CLOTHES | | USED FOR SILT ETC.?,PLAN MUSTPLANS SHOWSILT FENCE | | AROUND THE SITE | | 10.ANY CHANGES INWATER & SEWER PLANS? MUST BE | | APPROVED FROM 45TH STREET (MANNY G.), UTILITY DEPT | | BEFORE WE APPROVED | | 11.ANY CHANGES IN CATCH BASINS NEAREST YOUR SITE, AND | | AROUND YOUR SITE FOR STORM WATER DRAIN? | | | | RASIK CHOKSHI805-6723 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2006-11-13 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2006-11-13 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2006-11-13 |
Time |
13:29 |
Sent To |
|
|
Notes |
2006-11-13 13:32:51 | ACCORDING TO LETTER (E-MAIL) FROM STEVEN M. PAWLYK OF | | BOWER-SINGLETON DATED NOV 13, 06, THIS PERMIT IS | | COVERED UNDER PERMIT#06071716.SO, THIS IS PASSED | | | | RASIK CHOKSHI, 805-6723 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2007-04-19 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-04-19 |
Time |
18:45 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-04-19 |
Time |
16:46 |
Sent To |
|
|
Notes |
2007-04-19 18:45:23 | *****APPROVED***** | | | | | | ALL COMMENTS FROM FROM PREVIOUS FIRE PLAN REVIEWS HAVE | | BEEN ADDRESSED;PLAN SHEETS A1.3, A2.1, E3.1, E6.2, | | FP-01, AND FP-02 WERE STAMPED, INITIALED, AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-04-03 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-04-03 |
Time |
12:36 |
Sent To |
|
|
Notes |
2007-04-03 13:46:54 | ****PROVISO***** | | | | | | | | | | | | | | | | | | 20.FIRE ALARM SYSTEM IS TO BE CLASS A OR FULLY | | ADDRESSABLE.PLEASE CORRECT TYPOGRAPHICAL ERROR IN | | FIRE ALARM PLAN NOTE #3 (SEE SHEET E6.1 & E6.2); | | WORDING SHOULD BE ADDRESSABLE NOT ACCESSIBLE..... | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2007-01-30 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-01-30 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-01-30 |
Time |
10:25 |
Sent To |
|
|
Notes |
2007-01-30 10:34:27 | *****DENIED***** | | | | | | COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW ARE STILL | | IN NEED OF ACKNOWLEDGING IN/ON THE SUBMITTED PLANS. | | PLEASE BE ADVISED THAT A COPY OF 11/06/2006'S COMMENTS | | ARE ATTACHED. | | | | TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING, | | INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH | | ITEM WAS ADDRESSED | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-11-06 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-11-06 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-11-06 |
Time |
14:02 |
Sent To |
|
|
Notes |
2006-11-06 14:36:09 | *****DENIED***** | | | | | | | | 01.NFPA 101 - 2003 EDITION AND FLORIDA FIRE | | PREVENTION CODE - 2004 EDITION SHALL BE REFERENCED. | | | | 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | DEMOLITION SHALL COMPLY WITH NFPA241. | | | | 03.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL | | NOT INTERFERE OR HINDER EMERGENCY ACCESS TO THE SAID | | PROPERTY OR VICINITY THEREOF. | | | | 04.ALL PAVEMENT ROAD SYSTEMS SHALL BE CAPABLE OF | | SUPPORTING 32 TONS FOR FIRE EQUIPMENT. | | | | 05.LANDSCAPING SHALL NOT OBSTRUCT OR INTERFERE WITH | | FIRE PROTECTION EQUIPMENT.PROPER CLEARANCES SHALL BE | | MAINTAINED AT ALL TIMES. | | | | 06.SHOW/DISPLAY THE NUMERICAL ADDRESS OF THE BUILDING | | ON THE PROPER ELEVATION.AS PER WEST PALM BEACH CODE, | | THOSE NUMBERS SHALL BE NO LESS THAN 6" IN HEIGHT AND 1" | | IN WIDTH.IF A MONUMENT SIGN OR MARKEE IS REQUIRED, A | | NUMERICAL ADDRESS WILL ALSO BE POSTED.IF THERE ARE | | GOING TO BE SEVERAL ADDRESSED BUILDINGS WITHIN THE FED | | EX COMPLEX, A RANGE OF ADDRESSES FROM THE LOWEST TO THE | | HIGHEST WILL BE REQUIRED ON THE MONUMENT SIGN OR | | MARKEE. | | | | 07.FIRE DEPARTMENT CONNECTIONS (FDC'S) SHALL BE | | POSITIONED SO THAT THEY CANNOT BE BLOCKED BY STORAGE, | | VESSELS, EQUIPMENT, ETC. | | | | 08.KNOX LOCKING CAPS ARE REQUIRED FOR NEW FIRE | | DEPARTMENT CONNECTIONS. | | | | 09.ELECTRONIC SWITCHES IN ADDITION TO CHAIN AND LOCK | | IS REQUIRED FOR DOUBLECHECK DETECTOR ASSEMBLY. | | | | 10.KNOX BOX FOR THE BUILDING WILL BE REQUIRED. PLEASE | | CONTACT THE FIRE PREVENTION BUREAU AT (561) 804-4724 | | FOR APPLICATIONS. | | | | 11.WILL THERE BE SECURITY GATES TO THE PREMISES AND | | IF SO, HOW WILL THE MEANS OF EGRESS BE IMPACTED? | | | | 12.PLEASE PROVIDE PRESCIPTIVE STRENGHT FOR ALL | | HANDRAILS / GUARDRAILS. | | | | 13.ALL FIRE DOORS AND WINDOWS SHALL COMPLY WITH NFPA | | 80. | | | | 14.INTERIOR FINISH FOR WALLS AND CEILING IN EXITS AND | | EXIT ACCESS CORRIDORS SHALL BE CLASS "A" OR CLASS "B". | | | | 15.LIFE SAFETY PLAN SHALL INCLUDE ALL COMMON PATHS OF | | TRAVEL TO EXITS. | | | | 16.FIRE EXTINGUISHERS ARE TO BE RATED 2A-10BC. | | | | 17.SEPARATE SHOP DRAWINGS AND PERMITS ARE REQUIRED | | FOR FIRE SPRINKLER AND FIRE ALARM SYSTEMS. | | | | 18.FIRE SPRINKLER SYSTEM IS TO BE MONITORED. | | | | 19.THE FIRE ALARM SHALL BE UL CERTIFIED FOR CENTRAL | | STATION SERVICE. | | | | 20.FIRE ALARM SYSTEM IS TO BE CLASS A OR FULLY | | ADDRESSABLE. | | | | 21.DELAYED-EGRESS LOCKS AND/ORACCESS-CONTROLLED | | EGRESS DOORS SHALL COMPLY WITH NFPA 101, CH. 7.2.1.6, | | SPECIAL LOCKING ARRANGEMENTS. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2007-12-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-12-12 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-12-12 |
Time |
11:12 |
Sent To |
Z |
|
Notes |
2007-12-12 11:13:02 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2007-10-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-17 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-17 |
Time |
12:38 |
Sent To |
P |
|
Notes |
2007-10-17 12:39:20 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-10-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-05 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-05 |
Time |
14:51 |
Sent To |
E |
|
Notes |
2007-10-05 14:52:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-10-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-10-03 |
Time |
17:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-10-03 |
Time |
17:48 |
Sent To |
M |
|
Notes |
2007-10-03 17:48:22 | TO "M" BOX/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-06-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-19 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-19 |
Time |
10:25 |
Sent To |
P |
|
Notes |
2007-06-19 10:25:50 | TO "KSTEVENS" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-04-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-10 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-10 |
Time |
14:52 |
Sent To |
|
|
Notes |
2007-04-11 15:49:42 | TO "COMM" BD#12--PLANS ON RACK-6 ROLLS AND BINDERS | 2007-04-10 14:52:34 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-02-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-28 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-28 |
Time |
16:04 |
Sent To |
|
|
Notes |
2007-03-02 09:45:16 | TO "COMM" BD#13/PLANS ON RACK--5 ROLLS/BOOKS | 2007-02-28 16:04:36 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-11-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-01 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-11-01 |
Time |
10:52 |
Sent To |
|
|
Notes |
2007-01-04 08:22:17 | 1/4/06-TO "COMM" BD#5/ROLLED PLANS BY "BTROBAUG" DESK | 2006-12-15 11:23:45 | 12/8/06--WAITING FOR "COMM' BD | 2006-10-17 08:42:18 | TO "COMM' BD#40 | 2006-09-19 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2007-10-20 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-10-20 |
Time |
18:34 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-10-20 |
Time |
18:34 |
Sent To |
PC |
|
Notes |
2007-10-20 18:34:20 | PIPE PENETRATIONS, SUBMITTAL |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2007-10-04 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2007-10-04 |
Time |
07:42 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-03-27 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-03-27 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-03-26 |
Time |
15:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-01-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2007-01-18 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2007-01-18 |
Time |
15:07 |
Sent To |
|
|
Notes |
2007-01-18 15:27:02 | DENIED: | | RESPONSE TO COMMENTS FROM REVIEW DATED 10/20/06: | | | | COMMENT 1:OK | | COMMENT 2:OK | | COMMENT 3:RESPONSE INDICATES CO SENSORS ACTIVATION | | WILL BE AT 25 PPM.RESPONSE DOES NOT INDICATE | | MANUFACTURER SUBMITTAL DATA WITH REGARDS TO THE | | SENSORS.PLEASE NOTE, PLANS INDICATE FUME SENSORS | | MOUNTED AT 5 FT ABOVE FINISHED FLOOR WHEREAS THE | | MANUFACTURER'S INSTALLATION INSTRUCTIONS MAY DIFFER | | FROM THIS HEIGHT.PLEASE PROVIDE SUBMITTAL DATA ON THE | | SENORS. | | | | COMMENT 4 THROUGH 17:OK | | | | COMMENT 18: ALL ELECTRICAL & PLUMBING PLANS IN SOME OF | | THE PLAN SETS ARE MISSING SEAL, SIGNATURE AND DATE FROM | | THE ENGINEER OF RECORD AS REQUIRED BY FS 471.025 & FAC | | 61G15-23.002. | | | | NEW COMMENTS - PROVISO: | | 19.PLAN SHEET M3.1 KEYED NOTE 6 INIDCATES FANS WILL BE | | MOUNTED 36" ABOVE FINISHED FLOOR.PER 2004 FMC 303.4, | | EQUIPMENT SHALL NOT BE INSTALLED IN A LOCATION WHERE | | SUBJECT TO MECHANICAL DAMAGE UNLESS PROTECTED BY | | APPROVED BARRIERS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT PATTY KRAUSS | | AT (561)805-6719 OR E-MAIL [email protected]. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-10-20 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-10-20 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-10-20 |
Time |
11:32 |
Sent To |
|
|
Notes |
2006-10-20 15:28:51 | DENIED: | | 1.PLAN SHEET M1.1 INDICATES THE DESIGN IS TO THE | | INTERNATIONAL MECHANICAL CODE.THIS SHOULD READ 2004 | | FLORIDA BUILDING CODE/MECHANICAL. | | | | 2.PLAN SHEET M3.1 "KEYED NOTES" NUMBER 6 INDICATES | | THE INTAKE LOUVER FOR MAKE-UP AIR IS LOCATED 36" A.F.F. | | THIS APPEARS TO BE LOCATED IN A LOADING OR PARKING | | AREA.PER 2004 401.5.1 INTAKE OPENINGS SHALL BE | | LOCATED A MINIMUM OF 10 FT FROM ANY NOXIOUS CONTAMINANT | | SUCH AS PARKING LOTS, STREETS, ALLEYS, AND LOADING | | DOCKS.PLEASE CLARIFY. | | | | 3.PLAN SHEET M3.1 NOTE 3 INDICATES FUME SENSOR | | MOUNTED 5 FT A.F.F., MATCH TO EXISTING & CONNECT TO | | EXISTING SYSTEM.THE PERMIT APPLICATION INDICATES THIS | | IS A NEW BUILDING, WHAT WILL BE "EXISTING"? PROVIDE | | MANUFACTURE SUBMITTAL DATA FOR THE SENSOR.AT WHAT | | PARTS PER MILLION WILL THE SENSOR BE SET AT (25 PPM - | | PER 2004 FMC 404.1). | | | | 4.PLEASE INDICATE HOW THE REQUIREMENT FOR | | VENTILATION RATE OF .05 CFM PER SQUARE FT WHEN THE FANS | | WILL NOT RUN CONTINUOUSLY. | | | | 5.PLAN SHEET A2.1 DETAIL 1 (WEST ELEVATION), WHAT | | WILL BE USING THE DRIVE-IN DOOR, VEHICLES, FORK-LIFTS, | | ETC. | | | | 6.PLAN SHEET M3.1, PLEASE CLARIFY WHAT THE "SPECIAL | | HANDLING CAGE" WILL BE UTILIZED FOR.EF-10IS NOT | | INDICATED ON THE FAN SCHEDULE ON PLAN SHEET.PLAN | | SHEET M5.2 INDICATES AN EXHAUST FAN TO THE HOOD, IS | | THIS EF-10? | | | | 7.PLEASE INDICATE WHAT THE FUME HOOD WILL BE USED | | FOR. | | | | 8.PLAN SHEET M3.2 INDICATES DUCT SMOKE DETECTORS IN | | THE RETURN AIR DUCT.PER 2004 FMC 606.2.1, SMOKE | | DETECTORS ARE REQUIRED IN THE SUPPLY AIR DUCT. | | | | 9.PLEASE PROVIDE A DETAIL OF THE RTU ATTACHMENT TO | | THE ROOF.NO SUPPORT IS INDICATED ON THE STRUCTURAL, | | ARCHITECTURAL OR MECHANICAL PLANS.SHOW COMPLIANCE | | WITH 2004 FBC 1509.7. | | | | 10.PROVIDE LOCATION OF THE CONDENSING UNIT (GROUND OR | | ROOF). | | | | 11.PLEASE INDICATE ACCESS TO THE EQUIPMENT LOCATED ON | | THE ROOF.PER 2001 FMC 306.5, EQUIPMENT ON LOCATED ON | | ROOF OR ELEVATED STRUCTURE AT A HEIGHT GREATER THAN 16 | | FT SHALL HAVE A PERMANENT MEANS OF ACCESS.PLEASE | | NOTE,ACCESS SHALL NOT REQUIRE CLIMBING OVER | | OBSTRUCTIONS GREATER THAN 30 INCHES OR WALKING ON ROOFS | | HAVING A SLOPE GREATER THAN 4/12 PITCH. | | | | 12.PER 2004 FMC 306.6 ROOFS HAVING GREATER THAN 25% | | SLOPE AND HAVING AN EDGE MORETHAN 30 INCHES ABOVE GRADE | | AT SUCH EDGE, A LEVEL PLATFORM SHALL BE PROVIDED ON | | EACH SIDE OF THE APPLIANCETO WHICH ACDESS IS REQUIRED | | BY THE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR | | SERVICE, REPAIR OR MAINTENANCE.THE PLATFORM SHALL NOT | | BE LESS THAN 30 INCHES IN ANY DIMENSION AND BE PROVIDED | | WITH GUARDS IN ACCORDANCE WTIH SECTION 304.10. | | | | 13.PLEASE PROVIDE MOUNTING DETAIL FOR SF1 THROUGH | | 7.13. | | | | 14.PLANS DO NOT INDICATE OVERFLOW PROTECTION AS | | REQUIRED IN 2004 FMC 307.2.3. | | | | 15.PLAN SHEET A0,2 INDICATES "FUTURE FUEL ISLAND & | | MAITENANCE GARAGE"WILL THIS BE UNDER A SEPARATE | | PERMIT? | | | | 16.PLEASE PROVIDE OUTSIDE AIR CALCULATIONS IN | | ACCORDANCE WITH 2004 FMC TABLE 403.3. | | | | 17.PLEASE PROVIDE ENERGY CALCULATIONS IN ACCORDANCE | | WITH 2004 FBC CHAPTER 13 SUB-CHAPTER 4. | | | | 18.PER FAC 61G15-23.001(1), SEALS ARE TO BE EMBOSSED | | (RAISED) TYPE,STAMPS ARE NOT ACCEPTABLE.ENGINEERS | | SHALL LEGIBLY INDICATE NAME, ADDRESS, AND NUMBER ON | | EACH SHEET. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT PATTY KRAUSS | | AT (561)805-6719 OR E-MAIL [email protected]. | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
F |
Date |
2007-11-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-11-13 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-11-13 |
Time |
12:59 |
Sent To |
|
|
Notes |
2007-11-13 12:59:37 | REVISION DENIED. SDR-35 NOT FOR INSIDE THE BUILDING. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2007-06-20 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-06-20 |
Time |
17:54 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-06-20 |
Time |
17:54 |
Sent To |
|
|
Notes |
2007-06-20 17:56:24 | REVISIONS OK - REVISIONS TO SHEETS P1.1, P3.1, P7.1 & | | P8.1. SEE PSK-1, PSK-2, PSK-3 & PSK,4. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2007-03-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-03-21 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-03-21 |
Time |
10:55 |
Sent To |
|
|
Notes |
2007-03-21 10:57:40 | | | | | PASSED/PROVISO | | | | ONLY 50% OF THE DRINKING FOUNTAINS TO BE ACCESSIBLE. | | 50% SHALL BE AT NORMAL HEIGHT FOR THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING. | | | | | | | | | | .. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2007-03-19 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-03-19 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-03-19 |
Time |
10:45 |
Sent To |
|
|
Notes |
2007-03-19 10:51:03 | DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | MUNICIPAL CODE | | | | ***FROM PREVIOUS REVIEWS**** | | | | 1. ALL ARCHITECTURAL SHEETS. THE BUSINESS LICENSE | | NUMBER IS REQUIRED IN THE TITLE BLOCK PER FAC | | 61G1-16.004(2) & FS 481.2055. | | ****RESPONSE NOTED, BUT COMMENT WAS NOT ADDRESSED. | | ******NO RESPONSE, NOT ADDRESSED | | | | 2. OK | | | | 3. ALL M,E,P SHEETS. A CERTIFICATE OF AUTHORIZATION IS | | REQUIRED FOR THE ENGINEERING COMPANY PER FAC | | 61G15-23.002(2) & FS 471.025. - THE SIGNATURE OF THE | | ENGINEER IS REQUIRED ON THE SEAL. IT APPEARS TO BE AN | | INITIAL AND NOT A SIGNATURE. PLEASE PROVIDE A SIGNED, | | SEALED, DATED, NOTORIZED LETTER INDICATING THE LEGAL | | SIGNATURE OF THE ENGINEER FOR OUR FILES. FAC | | 61G15-23.002(1) & FS 471.025. | | ****RESPONSE NOTED, BUT NOT COMPLETLY ADDRESSED. THE | | CERTIFICATE OF AUTHORIZATION NUMBER (EB) IS NOT SHOWN | | ON THE TITLE BLOCK OF THE ENGINEER. ALSO THE SIGNED, | | SEALED, NOTORIZED LETTER REQUESTED INDICATING THE LEGAL | | SIGNATURE FOR OUR FILES HAS NOT BEEN SUBMITTED. | | ******RESPONSE NOTED, BUT THE SIGNED, SEALED, DATED, | | NOTORIZED LETTER REQUESTED SHOWING THE LEGAL SIGNATURE | | HAS NOT BEEN SUBMITTED. | | | | 4. OK | | 5. OK | | 6. OK | | 7. OK | | 8. OK | | | | *************NEW COMMENTS************* | | | | 1B. PER SECTION 11-4.1.3(10)(B) 50% OF ALL DRINKING | | FOUNTAINS PROVIDED SHALL COMPLY WITH 11-4.15. PLANS | | SHOW 7 DRINKING FOUNTAINS, BUT ONLY 1, (P8) COMPLIES. A | | MINIMUM OF 4 DRINKING FOUNTAINS SHALL COMPLY WITH | | SECTION 11-4.15 & ALL SUBSECTIONS. | | ******RESPONSE NOTED, BUT WITH ALL DRINKING FOUNTAINS | | BEING AT ACCESSIBLE HEIGHT, SECTION 11-4.1.3(10)(A), | | PROVISIONS FOR THOSE WHO HAVE DIFFICULTY BENDING OR | | STOOPING NOW NEEDS TO BE ADDRESSED. | | | | 2B. OK | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6713 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-01-24 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-01-24 |
Time |
18:48 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-01-24 |
Time |
18:48 |
Sent To |
|
|
Notes |
2007-01-24 19:00:39 | DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | MUNICIPAL CODE | | | | 1. ALL ARCHITECTURAL SHEETS. THE BUSINESS LICENSE | | NUMBER IS REQUIRED IN THE TITLE BLOCK PER FAC | | 61G1-16.004(2) & FS 481.2055. | | ****RESPONSE NOTED, BUT COMMENT WAS NOT ADDRESSED. | | | | 2. ALL M,E,P SHEETS. SEAL REQUIRED TO BE AN EMBOSSING | | TYPE SEAL, AND THE SEAL SHALL CONTAIN THE WORD | | "LICENSE" EFFECTIVE FEBRUARY 5, 2004, BUT A GRACE | | PERIOD TO JANUARY 1, 2006 WAS GIVEN. PLEASE CHANGE SEAL | | AND MAKE SURE IT IS A RAISED, IMPRESSION TYPE SEAL. | | (SEE ATTACHED SHEET)FAC 61G15-23.001 & FS 471.025. | | ****RESPONSE NOTED, BUT NOT ALL SHEETS FROM ALL THREE | | SETS HAVE BEEN SIGNED, SEALED, DATED. RECHECK SOME | | SHEETS THAT HAVE THE NEW SEAL AFFIXED AS NOT ALL THE | | INFORMATION FROM THE SEAL IS LEGIBLE. | | | | 3. ALL M,E,P SHEETS. A CERTIFICATE OF AUTHORIZATION IS | | REQUIRED FOR THE ENGINEERING COMPANY PER FAC | | 61G15-23.002(2) & FS 471.025. - THE SIGNATURE OF THE | | ENGINEER IS REQUIRED ON THE SEAL. IT APPEARS TO BE AN | | INITIAL AND NOT A SIGNATURE. PLEASE PROVIDE A SIGNED, | | SEALED, DATED, NOTORIZED LETTER INDICATING THE LEGAL | | SIGNATURE OF THE ENGINEER FOR OUR FILES. FAC | | 61G15-23.002(1) & FS 471.025. | | ****RESPONSE NOTED, BUT NOT COMPLETLY ADDRESSED. THE | | CERTIFICATE OF AUTHORIZATION NUMBER (EB) IS NOT SHOWN | | ON THE TITLE BLOCK OF THE ENGINEER. ALSO THE SIGNED, | | SEALED, NOTORIZED LETTER REQUESTED INDICATING THE LEGAL | | SIGNATURE FOR OUR FILES HAS NOT BEEN SUBMITTED. | | | | 4. SHT A3.4 SHOW COMPLIANCE WITH THE FOLLOWING: | | 11-4.16.5 FLUSH CONTROLS, 11-4.18.4 FLUSH CONTROLS, | | 11-4.19.2 CLEARANCES, 11-4.19.4 EXPOSED PIPES & | | SURFACES, 11-4.19.5 FAUCETS. | | ****RESPONSE NOTED, BUT COMMENTS ARE NOT ADDRESSED. | | (SEE DETAIL 13 FLUSH CONTROLS FOR 11-4.16.5- ALL | | OTHER INFORMATION NOT INDICATED). | | | | 5. OK | | | | 6. SHT P3.1 THE SAND/OIL INTERCEPTOR SHALL BE SIZED AND | | APPROVED BY THE UTILITY DEPT. CONTACT LYNN MASSON, | | ENVIRONMENTAL COMPLIANCE AT (561) 822-2271, OR FAX | | (561) 822-2279, OR E-MAIL [email protected]. WASTE ORD. | | 3434. | | ****RESPONSE NOTED. PLEASE SEE ATTACHED SHEET FROM MR. | | RODNEY COMPO INDICATING THE APPROVED MINIMUM | | RECOMMENDED SIZE OF INTERCEPTOR. THIS SHALL BE | | INDICATED ON THE PLANS. ALSO A ZURN MODEL Z1188 IS | | INDICATED. PLEASE INDICATE IF THIS IS THE MAKE & MODEL | | INTERCEPTOR BEING INSTALLED. IF NOT PLEASE INDICATE | | MAKE & MODEL OF INTERCEPTOR TO BE INSTALLED AND SUBMIT | | MANUF. SPECIFICATION SHEETS. | | | | 7. OK | | | | 8. SHT P8.2 WATER RISER DIAGRAM. SUBMIT A WATER RISER | | DIAGRAM IN AN ISOMETRIC FORM THAT REFLECTS THE FLOOR | | PLAN. SHOW ALL PIPE SIZES, VALVES, AND WATER HAMMER | | ARRESTORS REQUIRED BY SECTION 604.9 LOCATED IN AN | | "EFFECTIVE RANGE" (NOT IN THE CEILING). SECTION | | 106.1.3. - FULL OPEN VALVES ARE REQUIRED ON ALL WATER | | DOWN-FEED LINES. SECTION 606.1(2). | | ****RESPONSE NOTED, BUT SOME FULL OPEN VALVES ARE NOT | | INDICATED ON THE WATER DOWN-FEED LINES TO THE HOSE | | BIBBS. | | | | *************NEW COMMENTS************* | | | | 1B. PER SECTION 11-4.1.3(10)(B) 50% OF ALL DRINKING | | FOUNTAINS PROVIDED SHALL COMPLY WITH 11-4.15. PLANS | | SHOW 7 DRINKING FOUNTAINS, BUT ONLY 1, (P8) COMPLIES. A | | MINIMUM OF 4 DRINKING FOUNTAINS SHALL COMPLY WITH | | SECTION 11-4.15 & ALL SUBSECTIONS. | | | | 2B. SHT P4.1 PREVIOUSLY, THE RPZV BACKFLOW WAS LOCATED | | AT THE METER FOR THIS BUILDING. IS THE BACKFLOW AT THE | | METER TO BE DELETED? IS THERE A MASTER METER AND RPZV | | BACKFLOW FOR THE PROJECT? IF NOT, THE BACKFLOW WILL | | HAVE TO BE LOCATED AS NEAR THE METER AS POSSIBLE, ON | | PRIVATE PROPERTY.PLEASE CLARIFY. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6713 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-10-28 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-10-28 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-10-28 |
Time |
10:19 |
Sent To |
|
|
Notes |
2006-10-28 11:23:11 | DENIED | | REFERENCE: | | FBC-2004 PLUMBING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | MUNICIPAL CODE | | | | 1. ALL ARCHITECTURAL SHEETS. THE BUSINESS LICENSE | | NUMBER IS REQUIRED IN THE TITLE BLOCK PER FAC | | 61G1-16.004(2) & FS 481.2055. | | | | 2. ALL M,E,P SHEETS. SEAL REQUIRED TO BE AN EMBOSSING | | TYPE SEAL, AND THE SEAL SHALL CONTAIN THE WORD | | "LICENSE" EFFECTIVE FEBRUARY 5, 2004, BUT A GRACE | | PERIOD TO JANUARY 1, 2006 WAS GIVEN. PLEASE CHANGE SEAL | | AND MAKE SURE IT IS A RAISED, IMPRESSION TYPE SEAL. | | (SEE ATTACHED SHEET)FAC 61G15-23.001 & FS 471.025. | | | | 3. ALL M,E,P SHEETS. A CERTIFICATE OF AUTHORIZATION IS | | REQUIRED FOR THE ENGINEERING COMPANY PER FAC | | 61G15-23.002(2) & FS 471.025. - THE SIGNATURE OF THE | | ENGINEER IS REQUIRED ON THE SEAL. IT APPEARS TO BE AN | | INITIAL AND NOT A SIGNATURE. PLEASE PROVIDE A SIGNED, | | SEALED, DATED, NOTORIZED LETTER INDICATING THE LEGAL | | SIGNATURE OF THE ENGINEER FOR OUR FILES. FAC | | 61G15-23.002(1) & FS 471.025. | | | | 4. SHT A3.4 SHOW COMPLIANCE WITH THE FOLLOWING: | | 11-4.16.5 FLUSH CONTROLS, 11-4.18.4 FLUSH CONTROLS, | | 11-4.19.2 CLEARANCES, 11-4.19.4 EXPOSED PIPES & | | SURFACES, 11-4.19.5 FAUCETS. | | | | 5. SHT P1.1 FIXTURE CONNECTION SCHEDULE. FLOOR DRAINS | | ARE NOT APPROVED INDIRECT WASTE RECEPTORS. EITHER A | | FLOOR SINK OR A HUB DRAIN IS REQUIRED FOR THE INDIRECT | | WASTE FROM THE ICE MAKER, P-11. PLEASE CORRECT | | REFERENCE, AND IF SHOWN ON THE FLOOR PLAN AND THE SANT. | | RISER DIAGRAM, CHANGE THOSE ALSO. SECTIONS 802.3 & | | 802.3.2. | | | | 6. SHT P3.1 THE SAND/OIL INTERCEPTOR SHALL BE SIZED AND | | APPROVED BY THE UTILITY DEPT. CONTACT LYNN MASSON, | | ENVIRONMENTAL COMPLIANCE AT (561) 822-2271, OR FAX | | (561) 822-2279, OR E-MAIL [email protected]. WASTE ORD. | | 3434. | | | | 7. SHT P8.1 SANITARY RISER DIAGRAM. SUBMIT A SANITARY | | RISER DIAGRAM IN AN ISOMETRIC FORM THAT REFLECT THE | | FLOOR PLAN. SHOW ALL PIPE SIZES, VENTS, TRAPS AND | | INDICATE THE DRAINAGE FIXTURE UNITS AS THEY ACCUMULATE | | IN THE SYSTEM. SECTION 106.1.3. | | | | MAIN ENTRY: ISO?MET?RIC | | PRONUNCIATION: "I-S&-'ME-TRIK | | FUNCTION: ADJECTIVE | | 1 : OF, RELATING TO, OR CHARACTERIZED BY EQUALITY OF | | MEASURE; ESPECIALLY : RELATING TO OR BEING A | | CRYSTALLOGRAPHIC SYSTEM CHARACTERIZED BY THREE EQUAL | | AXES AT RIGHT ANGLES. | | | | 8. SHT P8.2 WATER RISER DIAGRAM. SUBMIT A WATER RISER | | DIAGRAM IN AN ISOMETRIC FORM THAT REFLECTS THE FLOOR | | PLAN. SHOW ALL PIPE SIZES, VALVES, AND WATER HAMMER | | ARRESTORS REQUIRED BY SECTION 604.9 LOCATED IN AN | | "EFFECTIVE RANGE" (NOT IN THE CEILING). SECTION | | 106.1.3. - FULL OPEN VALVES ARE REQUIRED ON ALL WATER | | DOWN-FEED LINES. SECTION 606.1(2). | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6713 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2007-12-13 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2007-12-13 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2007-12-13 |
Time |
11:57 |
Sent To |
|
|
Notes |
2007-12-13 12:00:59 | NOTE THAT THE LANDSCAPE PLAN SHALL BE THE GOVERNING | | DOCUMENT FOR THIS REVISION TO THE FOUNDATION LANDSCAPE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-03-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-03-27 |
Time |
18:06 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-03-27 |
Time |
18:06 |
Sent To |
|
|
Notes |
2007-03-27 18:07:17 | OK PER ERIC SCHNEIDER./WRT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-01-22 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2007-01-22 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2007-01-22 |
Time |
16:06 |
Sent To |
|
|
Notes |
2007-01-22 16:06:51 | FAILED | | | | 1) ALL APPLICABLE CONDITIONS OF ORDINANCE NO. 3987-06 | | SHALL BE SATISFIED, SPECIFICALLY: | | | | A) A TRAFFIC STATEMENT, PREPARED BY A LICENSED TRAFFIC | | ENGINEER, SHALL BE SUBMITTED TO THE PLANNING & ZONING | | AND CONSTRUCTION SERVICES DEPTS. OUTLINING THE NUMBER | | OF DAILY TRIPS, AM TRIPS AND PM TRIPS GENERATED BY THE | | FEDEX GROUND FACILITY. | | | | 2) PROVIDE A RECORDED COPY OF THE PLAT. | | | | 3) THE BOWYER SINGLETON PLANS AND THE LANDSCAPE PLANS | | SHALL BE REVISED TO REFLECT THE ADA SIDEWALK/ROUTE FROM | | THE EASTERNMOST DISABLED PARKING SPACE SHOWN ON THE | | ARCHITECT'S SITE PLAN FOR THE FEDEX FREIGHT FACILITY. | | | | 4) THE CORTLAN MORAN AND LANDSCAPE PLANS SHALL BE | | REVISED TO SHOW ALL OF THE "ISLAND FLUMES" AS DEPICTED | | ON THE BOWYER SINGLETON PLANS. | | | | 5) PARKING DETAIL ON BOWYER SINGLETON SHEET 13 OF 29 | | SHALL SHOW 2 FEET FROM THE CURB TO THE BACK OF THE | | WHEEL STOP, NOT 2 FEET TO THE MIDDLE OF THE WHEEL | | STOP. | | | | 6) A PARKING TABLE IS REQUIRED.THE 1ST REVISION | | RESPONSE STATED THERE IS A PARKING TABLE BUT FAILED TO | | IDENTIFY WHICH PLAN CONTAINED IT. | | | | 7) THE PROPERTY LINE SHOWN ON THE CORTLAN MORAN SHEET | | A0.2 AND ON BOWYER SINGLETON SHEET 4 OF 29 IS SHOWN | | INCORRECTLY AT THE CUL-DE-SAC. | | | | 8) THE SQUARE FOOTAGE LISTED FOR THE PHASE I BUILDING | | DIFFERS ON CORTLAN MORAN PLANS (97,298) AND BOWYER | | SINGLETON PLANS (97,297). | | | | 9) PLEASE RESPOND IN WRITING TO THE COMMENTS ABOVE. | | | | ERIC SCHNEIDER (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-11-01 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2006-11-01 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2006-11-01 |
Time |
13:36 |
Sent To |
|
|
Notes |
2006-11-01 14:15:50 | FAILED | | | | 1) ALL APPLICABLE CONDITIONS OF ORDINANCE NO. 3987-06 | | SHALL BE SATISFIED. | | | | A) A MINOR AMENDMENT IS REQUIRED TO: | | | | I) SHOW ALL IMPROVEMENTS OUTSIDE OF THE 12 FOOT WIDE | | UTILITY EASEMENT. | | | | II) CORRECT THE FEDERAL EXPRESS FREIGHT ADA PARKING (OR | | A LETTER FROM THE CONSTRUCTION SERVICES DEPT. STATING | | THAT THE PARKING AS SHOWN MEETS ADA REQ.) | | | | III) SHOW THE REQUIRED NOISE BARRIER ALONG THE EASTERN | | PROPERTY LINE OF PREMIER PARK OF COMMERCE. | | | | B) A TRAFFIC STATEMENT, PREPARED BY A LICENSED TRAFFIC | | ENGINEER, SHALL BE SUBMITTED TO THE PLANNING & ZONING | | AND CONSTRUCTION SERVICES DEPTS. OUTLINING THE NUMBER | | OF DAILY TRIPS, AM TRIPS AND PM TRIPS GENERATED BY THE | | FEDEX GROUND FACILITY. | | | | 2) THE PLAT IS REQUIRED TO BE RECORDED. | | | | 3) BOWYER SINGLETON SITE PLANS (SPECIFICALLY SHEET | | 3-29) ARE NOT THE LATEST VERSIONS APPROVED BY ORD. NO. | | 3987-06. | | | | 4) NO LANDSCAPE PLAN SUBMITTED - PLEASE VERIFY THAT | | WHEN SUBMITTED IT REFLECTS THE MINOR AMENDMENT CHANGES | | LISTED IN 1)A)III) ABOVE. | | | | 5) PARKING TABLE IS REQUIRED. | | | | 6) THE PARKING DETAIL ON CORTLAN MORAN SHEET A0.2 IS | | INCORRETCT.PLEASE USE OR REFERENCE THE DETAIL | | PROVIDED BY BOWYER SINGLETON ON SHEET 13 OF 29. | | | | ERIC SCHNEIDER (561) 822-1435. |
|
|
|