Plan Review Details - Permit 06090667
Plan Review Stops For Permit 06090667
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-02-07 Cont ID  
Sent By rnuquist Date 2007-02-07 Time 19:36 Rev Time 0.00
Received By rnuquist Date 2007-02-07 Time 19:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-10-16 Cont ID  
Sent By alange Date 2006-10-16 Time 08:28 Rev Time 0.00
Received By alange Date 2006-10-13 Time 13:24 Sent To  
Notes
2006-10-16 08:40:37DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE AND A COPY
 SUBMITTED TO THIS OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF
 THE DESCRIBED IMPROVEMENT OR CONSTRUCTION IS NOT
 COMMENCED WITHIN 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.PLANS SUBMITTED AFTER OCTOBER 1, 2005 SHALL BE
 DESIGNED TO THE 2004 FBC AND2004 FLORIDA RESIDENTIAL
 CODE AND 2004 EXISTING BUILDING CODE.CORRECT CODE
 SECTIONS SHOWN.SEE ALSO ASCE 7-98 SHOULD BE ASCE 7-02
 , STRUCTURAL NOTE 2C.
  
 4.WINDOW AT TUB LOCATONS SHALL HAVE SAFTEY GLAZING.
 R 308.4
  
 5.PROTECTION AGAINST DECAY.R 319.1IN AREAS
 SUBJECT TO DECAY DAMAGE AS ESTABLISHED BY TABLE
 R301.2(1) , THE FOLLOWING LOCATIONS SHALL REQUIRE THE
 USE OF AN APPROVED SPECIES AND GRADE OF LUMBER,
 PRESSURE TREATED IN ACCORDANCE WITH AWPA C1, C2, C3,
 C4, C9, C15, C18, C22, C23, C24, C28, C31, C33, P1, P2
 AND P3, OR DECAY-RESISTANT HEARTWOOD OF REDWOOD, BLACK
 LOCUST, OR CEDARS.
 2.ALL WOOD FRAMING MEMBERS THAT REST ON
 CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE
 LESS THAN 8 INCHES FROM THE EXPOSED GROUND.
 5.WOOD SIDING, SHEATHING AND WALL
 FRAMING ON THE EXTERIOR OF A BUILDING HAVING A
 CLEARANCE OF LESS THAN 6 INCHESFROM THE GROUND.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH QUALITY
 ASSURANCE SHALL HAVE THE FOLLOWING STATE APPROVAL
 ATTACHED.NOTE:INCORRECT STATE PAGES SUBMITTED FOR
 PGT, TAMKO AND TOWN AND COUNTRY.SEE TM WINDOW AND
 DOOR APPROVAL FOR AN EXAMPLE.
  
 PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION
 AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE
 SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL SHEETS THAT
 LISTS THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF
 THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN
 APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC
 FORM PER RULE 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE REGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.WPB AMENDMENT TO FBC 106.3.3.
  
  
 8.A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR
 A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.SHOW HOW PLANS
 WILL COMPLY WITH THE SECTION(S) SELECTED.2004 FBC
 EXISTING BUILDING 301.5
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. SUBMIT ONE
 COPY OF OLD PAGES FOR REFERENCE . A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DEPARTMENT
 561-805-6672
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-12-14 Cont ID  
Sent By btrobaug Date 2006-12-14 Time 15:50 Rev Time 0.33
Received By btrobaug Date 2006-12-14 Time 15:37 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-09-28 Cont ID  
Sent By btrobaug Date 2006-09-28 Time 07:15 Rev Time 0.50
Received By btrobaug Date 2006-09-28 Time 07:02 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-12-12 Cont ID  
Sent By adarroug Date 2006-12-12 Time 18:32 Rev Time 0.00
Received By adarroug Date 2006-12-12 Time 18:32 Sent To M
Notes
2006-12-12 18:33:06TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-11-29 Cont ID  
Sent By mmiller Date 2006-11-29 Time 17:42 Rev Time 0.00
Received By mmiller Date 2006-11-29 Time 17:42 Sent To Z
Notes
2006-11-29 17:42:41SENT TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-09-26 Cont ID  
Sent By adarroug Date 2006-09-26 Time 13:49 Rev Time 0.00
Received By adarroug Date 2006-09-26 Time 13:49 Sent To E
Notes
2006-09-26 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-10-16 Cont ID  
Sent By alange Date 2006-10-16 Time 08:40 Rev Time 0.00
Received By alange Date 2006-09-20 Time 16:20 Sent To  
Notes
2006-09-20 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-12-13 Cont ID  
Sent By tgordon Date 2006-12-13 Time 14:12 Rev Time 0.20
Received By tgordon Date 2006-12-13 Time 14:11 Sent To E
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-10-10 Cont ID  
Sent By tgordon Date 2006-10-10 Time 12:20 Rev Time 0.30
Received By tgordon Date 2006-10-10 Time 12:20 Sent To B
Notes
2006-10-10 12:25:00*** DENIED ***
 1) RETURN AIR TRANSFER GRILL IS TO SMALL
 SEE NOTE #2 (B),PLEASE CORRECT.
  
 2) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-12-20 Cont ID  
Sent By mperson Date 2006-12-20 Time 10:02 Rev Time 0.33
Received By mperson Date 2006-12-20 Time 10:02 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-10-10 Cont ID  
Sent By mperson Date 2006-10-10 Time 08:34 Rev Time 0.45
Received By mperson Date 2006-10-10 Time 08:34 Sent To M
Notes
2006-10-10 09:10:07UNSAT
 REFERENCE: FBC-2004 PLUMBING
  
 THE FOLLOWING INFORMATION IS REQUIRED FOR PLUMBING PLAN
 REVIEW:
  
 1. THE ISOMETRIC SANITARY PLUMBING RISER DIAGRAM ON
 SHEET A-3 DOES NOT REFLECT THE PLUMBING LAYOUT ON SHEET
 A-3.
 PLEASE CORRELATE THE ISOMETRIC SANITARY PLUMBING RISER
 DIAGRAM WITH THE PLUMBING LAYOUT.
 PLEASE REFERENCE THE CORRECTED ISOMETRIC SANITARY RISER
 DIAGRAM IN RED INK REFLECTING THE PLUMBING LAYOUT ON
 SHEET A-3.
 2. THE PERMIT APPLICATION INDICATES UPDATE KITCHEN AND
 BATHROOMS. EXACTLY WHAT DOES THIS INVOLVE? PLEASE
 INDICATE ON THE DRAWING IF THE EXISTINGKITCHEN AND
 BATHROOM UPDATES ARE EXACT FIXTURE CHANGE OUTS, OR IF
 THERE IS ANY CHANGE IN THE KITCHEN AND BATHROOM LAYOUTS
 PLEASE ADD CHANGES TO THE SANITRY ISOMETRIC RISER
 DIAGRAM.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-12-08 Cont ID  
Sent By mmclean Date 2006-12-08 Time 11:31 Rev Time 0.00
Received By mmclean Date 2006-12-08 Time 11:31 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2006-09-23 Cont ID  
Sent By mmclean Date 2006-09-23 Time 07:40 Rev Time 0.00
Received By mmclean Date 2006-09-23 Time 07:40 Sent To I
Notes
2006-09-23 00:00:00DENIED,
 1. PLEASE SUBMIT TWO COPIES OF CURRENT
 SURVEYS.
 2. THE SUBMITTED SURVEYS MUST SHOW THE
 PROPOSED WORK WITH SETBACKS FROM THE
 PROPERTY LINE (FRONT/SIDE).
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720