Plan Review Details - Permit 06090552
Plan Review Stops For Permit 06090552
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-12-26 Cont ID  
Sent By shill Date 2006-12-26 Time 14:47 Rev Time 0.00
Received By shill Date 2006-12-26 Time 14:47 Sent To Z
Notes
2006-12-26 14:48:13PROVISO - PARKING TO COMPLY WITH CITY OF WPB STANDARD

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-11-05 Cont ID  
Sent By shill Date 2006-11-05 Time 13:34 Rev Time 0.00
Received By shill Date 2006-11-05 Time 13:09 Sent To  
Notes
2006-11-05 13:46:29****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
 1.)C-1, SHOWS A RAMP WITH A NOTE THAT IT IS TO BE IN
 COMPLIANCE WITH FDOT.RAMPS ARE TO ALSO COMPLY WITH
 FBC11-4.8.PROVIDE DETAILS SHOWING SLOPE, WIDTH, CROSS
 SLOPE.IF A HANDRAIL IS REQUIRED, PROVIDE DETAILS
 FBC11-4.8.5.
  
 2.)THE CROSS SLOPE NEAR THE NOTE "CONSTR HANDICAP
 RAMP PER FDOT INDEX 304" APPEARS TO BE 12% (FROM 19.48
 TO 20.08).THIS IS A PART OF THE ACCESSIBLE ROUTE, SEE
 FBC11-10.2, BUS STOPS AND TERMINALS.CROSS SLOPE
 CANNOT EXCEED 1:50, FBC11-4.3.7.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-10-04 Cont ID  
Sent By shill Date 2006-10-04 Time 11:06 Rev Time 0.00
Received By shill Date 2006-10-03 Time 14:54 Sent To ENG
Notes
2006-10-04 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004
 RESIDENTIAL
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)SEE FBC11-4.1(1)(A) AND DEFINITION
 OF FACILITIES, FBC11-3.ACCESSIBILITY
 REQUIRED.
  
 2.)ACCESSIBLE PARKING REQUIRED,
 FBC11-4.1.2(5)(A).PROVIDE A DETAIL ON
 THE PLAN.SEE ATTACHED FOR CITY OF WEST
 PALM BEACH STANDARD.
  
 3.)PLEASE REVIEW THE FOLLOWING WEBSITE
 IN REGARDS TO GUIDELINES FOR
 RECREATIONAL FACILITIES.INFORMATIONAL
 ONLY; DOES NOT NEED TO BE ADDRESSED.
  
 HTTP://WWW.ADAPORTAL.ORG/RECACCESS/
 RECREATIONACCESS.HTM
  
 4.)PROVIDE PRODUCT APPROVALS FOR THE
 PLASTIC ROOF SHOWN ON THE PLAN, SIGN
 KIOSK.PRODUCT APPROVALS ARE TO BE
 REVIEWED BY DESIGNER OF RECORD,
 FBC*106.3.3.

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2006-12-21 Cont ID  
Sent By rchokshi Date 2006-12-21 Time 13:48 Rev Time 0.00
Received By rchokshi Date 2006-12-21 Time 13:48 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2006-11-02 Cont ID  
Sent By rchokshi Date 2006-11-02 Time 15:04 Rev Time 0.00
Received By rchokshi Date 2006-11-02 Time 13:57 Sent To B
Notes
2006-11-02 14:26:06FAILED FOR FOLLOWING REASONS:
  
 PLEASE ANSWER EACH ITEMS EXPLAINED ON 10/05/06,
  
 FOR EXAMPLE,POLLUTION PREVENTION PLANS, SILT FENCE
 AROUND SITEMUST BE DRAWN BY CAD OR DRAWN TO SCALE
 WITH SYMBOL EXPLAINED IN THE DRAWING, WHAT IS THAT
 SYMBOL FOR SILT FENCE AROUND SITE, IF ANY?ALSO,
 PLEASE DRAW DETAILS OF SILT, SILT POLES, SILT FENCE
 HEIGHT,CLOTHS, ETC., NEED COMPLETE DETAILS &
 DESCRIPTION OF THE SILT FENCE ON THE DRAWINGS, CALLED
 POLLUTION PREVENTION PLAN & DETAILS ON THE DRAWINGS.
 CONSTRUCTION WORKERS DO NOT HAVE ACCESS TO READ SECTION
 01000, GENERAL REQUIREMENTS, SUBSECTION 1.04 PROVISION
 ETC. ETC., AS YOU SAID IN YOURRESPONCE LETTER OF(NO
 DATE), WHICH IS NOT ACCEPTABLE TO US.
  
 ALL CITY OF WPB STANDARDS & DETAILS (WHICH WE ASKED ON
 10/05/06) MUST BE DRAWN ON THE DRAWINGS.
  
 ALSO, PLEASE PROVIDETOTAL SITE AREA, PERVIOUS AREA,
 IMPERVIOUS AREA ON THE DRAWING, NEED FULL EXPLANATION.
  
  
 RASIK CHOKSHI 805-6723

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2006-10-05 Cont ID  
Sent By rchokshi Date 2006-10-05 Time 13:38 Rev Time 0.00
Received By rchokshi Date 2006-10-05 Time 13:22 Sent To  
Notes
2006-10-05 00:00:00PLEASE SHOW POLLUTION PREVENTION PLANS &
 DETAILS.
 MUST MEET STANDARDS OF CITY OF WPB FOR
 DRIVEWAY,SIDEWALK,APPROACH, HANDICAP
 PARKING PER ADA, DUMPSTER ENCLOSURE.
 PLEASE SHOW ALL THESE DETAILS OF CITY OF
 WPB STANDARDS ON THE DRAWINGS.
 PLEASE SHOW WATERMAIN,SEWER, & STORM
 WATER CONNECTIONS IF ANY? THEN MUST BE
 APPROVED FROM 45TH STREET
 ENGINEERING.(MANNY G.)
 HOW YOU ARE GOING TO TAKE CARE OF
 RUNNING WATER FROM IMPERVIOUS AREA, LIKE
 PARKING LOT, OR ANY IMPERVIOUS AREA?
 PLEASE SHOW SWALE OR POND OR SOMETHING ?
 PLEASE SHOW ELEVATION FOR
 SIDEWALK,TRAIL,ROAD CENTER LINE,PARKING
 AREA ETC., MUST MEET FL BUILDING CODES.
  
 RASIK CHOKSHI 805-6723

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-12-04 Cont ID  
Sent By adarroug Date 2006-12-04 Time 15:47 Rev Time 0.00
Received By adarroug Date 2006-12-04 Time 15:47 Sent To Z
Notes
2006-12-04 15:48:13TO "ENG" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-10-27 Cont ID  
Sent By adarroug Date 2006-10-27 Time 08:06 Rev Time 0.00
Received By adarroug Date 2006-10-27 Time 08:06 Sent To ENG
Notes
2006-10-27 08:06:40TO "ENG" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-10-25 Cont ID  
Sent By adarroug Date 2006-10-25 Time 17:29 Rev Time 0.00
Received By adarroug Date 2006-10-25 Time 17:29 Sent To Z
Notes
2006-10-25 17:30:28TO "Z" BOX/RESUB--NEW SHEETS FOR "Z"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-09-27 Cont ID  
Sent By adarroug Date 2006-09-27 Time 13:47 Rev Time 0.00
Received By adarroug Date 2006-09-27 Time 13:47 Sent To B
Notes
2006-09-27 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-10-25 Cont ID  
Sent By adarroug Date 2006-10-05 Time 17:23 Rev Time 0.00
Received By adarroug Date 2006-09-15 Time 16:50 Sent To  
Notes
2006-09-15 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 3 Status P Date 2006-12-27 Cont ID  
Sent By eschneid Date 2006-12-27 Time 12:36 Rev Time 0.00
Received By eschneid Date 2006-12-27 Time 12:36 Sent To I
Notes
2006-12-27 12:48:45PASSED WITH PROVISOS
  
 1) PARKING DETAIL SHEET C-3: 12 INCHES REQUIRED BETWEEN
 THE WHITE STRIPES AND THE LOGO IS REQ. TO BE 2 FEET
 FROM THE OPEN END OF THE PARKING SPACE.
  
 2) LANDSCAPE PLAN SHEET L-1: 4 ADDITIONAL TREES REQ. AT
 LOCATIONS DESIGNATED WITH THE *.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1435.

Review Stop Z ZONING
Rev No 2 Status P Date 2006-10-26 Cont ID  
Sent By eschneid Date 2006-10-26 Time 17:07 Rev Time 0.00
Received By eschneid Date 2006-10-26 Time 17:07 Sent To I
Notes
2006-10-26 17:11:27PLEASE NOTE THAT A SHADE OR FLOWERING TREE IS REQUIRED
 IN EACH TERMINAL ISLAND AND INTERIOR ISLAND IN THE
 PARKING AREA.

Review Stop Z ZONING
Rev No 1 Status P Date 2006-09-26 Cont ID  
Sent By eschneid Date 2006-09-26 Time 09:34 Rev Time 0.00
Received By eschneid Date 2006-09-26 Time 09:34 Sent To  
Notes
***NONE***