Plan Review Details - Permit 06090492
Plan Review Stops For Permit 06090492
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-09-21 Cont ID  
Sent By lursu Date 2006-09-21 Time 15:08 Rev Time 0.00
Received By lursu Date 2006-09-21 Time 15:08 Sent To  
Notes
2006-09-21 00:00:00THE CORRECT PCN IS 74434310190080020

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-10-06 Cont ID  
Sent By amorse Date 2006-10-06 Time 15:41 Rev Time 0.00
Received By amorse Date 2006-10-06 Time 15:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-09-18 Cont ID  
Sent By amorse Date 2006-09-18 Time 16:29 Rev Time 0.00
Received By amorse Date 2006-09-18 Time 16:29 Sent To  
Notes
2006-09-18 00:00:00 
  
 DENIED
  
 1) PROVIDE FULL ELEVATION AND STRUCTURAL
 DRAWINGS THAT SHOW THE BEAMS AND COLUMNS
 THAT WILL BE AFFECTED BY THE PARTIAL
 REMOVAL OF COLUMNS FOR THE NEW WINDOW
 SYSTEM
  
 2) PROVIDE THE MEANS THAT WILL BE USED
 TO SUPPORT THE STRUCTURE FOR THE MEW
 OPENING ( LINTEL, COLUMNS, ETC.)
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-10-06 Cont ID  
Sent By dpalmer Date 2006-10-06 Time 16:01 Rev Time 0.00
Received By dpalmer Date 2006-10-06 Time 16:01 Sent To  
Notes
2006-10-06 00:00:00ELECTRICAL DEMO PERMIT REQUIRE BEFORE
 ANY DEMO WORK IS TO PROCEED WHICH AFFECT
 ELECTRICAL SYSTEMS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-09-20 Cont ID  
Sent By dpalmer Date 2006-09-20 Time 07:41 Rev Time 0.00
Received By dpalmer Date 2006-09-20 Time 07:38 Sent To  
Notes
2006-09-20 00:00:00****UNSAT ****
  
 1) NOTE: PLEASE KNOW, AS THE PLANS
 SUBMITTED ARE REQUIRED TO BE STAMPED FOR
 "ELECTRCIAL PERMITS REQUIRED FOR
 ELECTRICLA DEMO", DUE TO THE BUILDING
 REVIEW COMMENTS, PLANS CAN NOT BE
 STAMPED AT THIS TIME.
  
 ** PLEASE SEE SITE/SURVEYS SUBMITTED ARE
 NOT REQUIRED. PLEASE KNOW HOWEVER IF
 THEY HAD BEEN THE PLANS ARE SEALED
 PHOTO-COPIES OF THE SIGNATURE WHICH IS
 REQUIRED TO BE ORIGINAL.
 FAC 61G17, FS 4720.025.
 PLEASE KNOW THIS IS FOR INFORMATIONAL
 PURPOSE ONLY.
  
 ONCE BUILDING REVIEW COMMENTS ARE
 ADDRESSED, PLANS MAY BE STAMPED.
  
 IF THERE ARE ANY QUESTIONS, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2006-10-18 Cont ID  
Sent By mwennerg Date 2006-10-18 Time 14:20 Rev Time 0.00
Received By mwennerg Date 2006-10-18 Time 14:20 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-09-21 Cont ID  
Sent By mwennerg Date 2006-09-21 Time 14:17 Rev Time 0.00
Received By mwennerg Date 2006-09-21 Time 14:17 Sent To  
Notes
2006-09-21 00:00:00***DENIED***
  
 1) PLEASE SEE BUILDING REVIEW COMMENT
 (1) AND PROVIDE INFORMATION.
  
 2) CONSTRUCTION, ALTERATION AND
 DEMOLITION SHALL COMPLY WITH NFPA 241.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-10-04 Cont ID  
Sent By adarroug Date 2006-10-04 Time 13:45 Rev Time 0.00
Received By adarroug Date 2006-10-04 Time 13:45 Sent To  
Notes
2006-10-04 00:00:00TO "BOB"#11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-09-27 Cont ID  
Sent By kstevens Date 2006-09-27 Time 15:27 Rev Time 0.00
Received By kstevens Date 2006-09-15 Time 16:20 Sent To  
Notes
2006-09-18 00:00:00TO "BOB"#10
2006-09-15 00:00:00WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-09-18 Cont ID  
Sent By tgordon Date 2006-09-18 Time 13:33 Rev Time 0.15
Received By tgordon Date 2006-09-18 Time 13:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2006-10-17 Cont ID  
Sent By kstevens Date 2006-10-17 Time 10:56 Rev Time 0.00
Received By kstevens Date 2006-10-17 Time 10:56 Sent To  
Notes
2006-10-17 10:56:52DEMO PLUMBING PERMIT REQUIRED. DEAD ENDS ARE PROHIBITED
 PER SECTION 704.5.

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-09-27 Cont ID  
Sent By kstevens Date 2006-09-27 Time 14:45 Rev Time 0.00
Received By kstevens Date 2006-09-27 Time 14:45 Sent To  
Notes
2006-09-27 00:00:00DEMO ONLY - NO PLANS REQUIRED. DEAD ENDS
 PROHIBITED, SECTION 704.5. - DEMO
 PLUMBING PERMIT REQUIRED.