Plan Review Stops For Permit 06090369 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-10-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-10-18 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-10-18 |
Time |
09:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-06-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-05-02 |
Time |
16:19 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2007-05-02 |
Time |
16:19 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-11-27 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-11-27 |
Time |
16:40 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-11-17 |
Time |
12:20 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-09-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-09-21 |
Time |
16:02 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-09-21 |
Time |
15:41 |
Sent To |
P |
|
Notes |
2006-09-21 00:00:00 | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} PROVIDE MANUFACTURERS SPECIFICATIONS | | ALSO RECOMMENDATION REGARDING | | CLEARANCES, FOR THE GENERATOR. | | | | 2} PROVIDE SPECIFICATIONS FOR THE | | TRANSFER SWITCH. | | | | 3} AN ELEVATION CERTIFICATE IS REQUIRED. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2006-11-27 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-11-27 |
Time |
15:58 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2006-11-27 |
Time |
15:58 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2006-09-27 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-09-27 |
Time |
09:48 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-09-27 |
Time |
09:48 |
Sent To |
B |
|
Notes |
2006-09-27 00:00:00 | ******DENIED****** | | REFERENCE: FBC-2004 FUEL GAS | | FBC-2004 CHAPTER 1 | | | | THE FOLLOWING INFORMATION IS REQUIRED ON | | THE ISOMETRIC DRAWING FOR GAS PLAN | | REVIEW: | | | | 1. BTU LOAD OF EACH APPLIANCE AND THE | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | 402.4(33). | | NOTE: THIS INCLUDES THE EXISTING GAS | | SYSTEM PLEASE SEE THE ATTACHED PERMIT | | INFORMATION INDICATING GAS AT SAID | | ADDRESS. | | | | 2. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | NOTE: REFERENCE NOTE ON COMMENT 1 | | | | 3. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT AND INSTALLATION INSTRUCTIONS | | TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | 54, NFPA 58, AND THE FBC-2004 FUEL GAS | | CODE SEC 402.2 | | NOTE: NEED SHEETS ON REGULATORS AND | | GENERATOR. | | | | 4. FBC-2004 CHAPTER 1,SECTION 106.3.4.2: | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | THE DRAWING SHALL CLEARLY PRINT AND SIGN | | NAME, AND ALSO DATE DRAWING. PLEASE DO | | THIS PRIOR TO RESUBMITTING. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-04-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-23 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-23 |
Time |
15:01 |
Sent To |
E |
|
Notes |
2007-04-23 15:01:53 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-03-27 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-03-27 |
Time |
17:44 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-03-27 |
Time |
17:44 |
Sent To |
M |
|
Notes |
2007-03-27 17:44:21 | TO TOM GORDON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-03-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-25 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-25 |
Time |
12:29 |
Sent To |
Z |
|
Notes |
2007-03-25 12:30:03 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-11-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-16 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-16 |
Time |
15:06 |
Sent To |
E |
|
Notes |
2006-11-16 15:06:41 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-09-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-20 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-20 |
Time |
14:56 |
Sent To |
E |
|
Notes |
2006-09-20 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-10-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-10-18 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-09-13 |
Time |
14:01 |
Sent To |
|
|
Notes |
2006-09-13 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-03-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-03-28 |
Time |
08:53 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-03-28 |
Time |
08:53 |
Sent To |
|
|
Notes |
2007-03-28 08:56:04 | *** PROVISO *** | | 1) PER 2004 FBC, FUEL GAS - POWERED | | EQUIPMENT - PERMANENTLY INSTALLED | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | WITH MANUFACTURER'S INSTALLATION | | INSTRUCTIONS AND NFPA 37. | | | | NFPA 37 INSTALLATION & USE OF STATIONARY COMBUSTION | | ENGINES & GAS TURBINES: | | 4.1.4ENGINES (GENERATORS) LOCATED | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE RESISTANCE | | RATING OF 1 HOUR OR (2) THE WEATHERPROOF ENCLOSURE IS | | CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS, AND IT HAS | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | MATERIALS OUTSIDE THE ENCLOSURE. | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | THE VENTILATION INTAKES. | | | | 2004 FMC 804.3.5 #3, WHERE THE | | TERMINATION IS LOCATED BELOW AN ADJACENT | | ROOF STRUCTURE, THE TERMINATION POINT | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | ROOF STRUCTURE. | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | INTO THE REQUIRED SETBACK, GENERATORS | | SHALL MAINTAIN THE REQUIRED ABOVE | | MENTIONED CLEARANCES TO THE ADJACENT | | PROPERTY STRUCTURES, I.E. FENCE, | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | FOLLOW MANUFACTURER'S RECOMMENDED | | CLEARANCES AROUND EQUIPMENT FOR | | SERVICING,AND PROVIDE MANUFACTURER'S | | INSTALLATION INSTRUCTIONS AT THE JOBSITE | | FOR THE FIELD INSPECTOR. | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2006-11-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-11-28 |
Time |
08:42 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-11-28 |
Time |
08:42 |
Sent To |
|
|
Notes |
2006-11-28 08:44:06 | *** PROVISO *** | | 1) PER 2004 FBC, FUEL GAS - POWERED | | EQUIPMENT - PERMANENTLY INSTALLED | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | WITH MANUFACTURER'S INSTALLATION | | INSTRUCTIONS AND NFPA 37. | | | | NFPA 37 INSTALLATION & USE OF STATIONARY COMBUSTION | | ENGINES & GAS TURBINES: | | 4.1.4ENGINES (GENERATORS) LOCATED | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE RESISTANCE | | RATING OF 1 HOUR OR (2) THE WEATHERPROOF ENCLOSURE IS | | CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS, AND IT HAS | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | MATERIALS OUTSIDE THE ENCLOSURE. | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | THE VENTILATION INTAKES. | | | | 2004 FMC 804.3.5 #3, WHERE THE | | TERMINATION IS LOCATED BELOW AN ADJACENT | | ROOF STRUCTURE, THE TERMINATION POINT | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | ROOF STRUCTURE. | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | INTO THE REQUIRED SETBACK, GENERATORS | | SHALL MAINTAIN THE REQUIRED ABOVE | | MENTIONED CLEARANCES TO THE ADJACENT | | PROPERTY STRUCTURES, I.E. FENCE, | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | FOLLOW MANUFACTURER'S RECOMMENDED | | CLEARANCES AROUND EQUIPMENT FOR | | SERVICING,AND PROVIDE MANUFACTURER'S | | INSTALLATION INSTRUCTIONS AT THE JOBSITE | | FOR THE FIELD INSPECTOR. | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-03-27 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-03-27 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-03-27 |
Time |
09:22 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2006-09-18 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-09-18 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-09-18 |
Time |
17:56 |
Sent To |
I |
|
Notes |
2006-09-18 00:00:00 | NOTE: THE PROPOSED GENERATOR SHALL NOT | | BE CLOSER THAN 6FT FROM SIDE PROPERTY | | LINE. |
|
|