Plan Review Details - Permit 06090243
Plan Review Stops For Permit 06090243 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2008-10-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-10-24 |
Time |
11:26 |
Rev Time |
1.55 |
Received By |
jwitmer |
Date |
2008-10-24 |
Time |
11:26 |
Sent To |
|
|
Notes |
2008-10-24 11:27:04 | BUILDING PROVISO: SHEET 3.1 | | 1) 1009.11 HANDRAILS WILL REQUIRED ON BOTH SIDES OF THE | | STAIRS. | | 2) 1012.1 GUARDRAIL REQUIRED ON THE OPEN SIDE OF THE | | STAIRS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-07-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-07-24 |
Time |
16:46 |
Rev Time |
2.20 |
Received By |
jwitmer |
Date |
2008-07-24 |
Time |
16:46 |
Sent To |
|
|
Notes |
2008-07-24 16:56:43 | BUILDING PROVISO: SHEET 3.1 | | 1) 1009.11 HANDRAILS WILL REQUIRED ON BOTH SIDES OF THE | | STAIRS. | | 2) 1012.1 GUARDRAIL REQUIRED ON THE OPEN SIDE OF THE | | STAIRS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-02-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2008-02-14 |
Time |
13:53 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2008-02-14 |
Time |
13:53 |
Sent To |
|
|
Notes |
2008-02-14 13:53:42 | BUILDING PLAN REVIEW | | PERMIT: 06090243 | | ADD: 5312 BROADWAY | | CONT: 3-D HOMES | | TEL: (561)662-9327 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2005 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | 4TH ACTION: DENIED | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | 1B) INFORMATIONAL ONLY. PLEASE SUBMIT 2 OF ALL SURVEYS, | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | SUBMITTALS FOR REVIEW FOR PERMIT. | | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF | | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A | | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID | | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* | | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH | | ADMINISTRATIVE CODE. | | | | 1C) INFORMATIONAL ONLY.106.1.1* W.P.B. ADMINISTRATIVE | | CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION | | SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE | | CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR | | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | AFTER NOV. 21ST,2005 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE2005 REVISIONS. | | | | 2-4) COMPLIED. | | | | 5) COMPLIED. | | | | 6-8) COMPLIED. | | | | 9) COMPLIED. | | | | 9B) SEMI-COMPLIED. THE NEWDOOR SWINGS INTO THE CLEAR | | FLOOR SPACE REQUIRED BY THE COMMON USE SINKS. | | | | 12-16) COMPLIED. | | | | 17A) SEMI-COMPLIED. PLANS STILL INDICATE WALLS THAT | | MAKE UP THE VERTICAL STAIR SHAFT THAT ARE NOT RATED. | | SEE SHAFTS 707.4. ALSO PROVIDE RATED DOORS FOR THE | | VERICAL EXIT ENCLOSURE. | | SEE 715.3. | | | | 18-21) COMPLIED. | | | | 22)COMPLIED. | | NEW COMMENTS | | 23)CORRIDOR WALLS AROUND THE FIRST AND SECOND FLOOR | | ASSEMBLY OCCUPANCIES THE PLANS DO NOT INDICATE AS RATED | | WALLS PLEASE SEE TABLE 1016.1. | | | | 24)PLANS WILL NEED TO CORRECT THEIR OCCUPANT COUNTS | | OFFICES ARE 100 SQ FT PER PERSON, AND FIRST FLOOR | | ASSEMBLY REWRITE 7 SQ FT PER PERSON. | | | | 25) THE SECOND FLOOR ONE EXIT IS OUT ONTO THE ROOF, AND | | DOWN AN EXIT STAIRWAY. THE PLANS SHOW A LINE THAT WOULD | | INDICATE A CHANGE IN ELEVATION ON THE ROOF. PLEASE | | PROVIDE | | WHAT CHANGE IN ELEVATION THIS IS? AND IF STAIRS WOULD | | BE REQUIRED. | | | | | | | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECODS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-10-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-10-30 |
Time |
11:23 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2007-10-30 |
Time |
11:23 |
Sent To |
|
|
Notes |
2007-10-30 11:25:19 | BUILDING PLAN REVIEW | | PERMIT: 06090243 | | ADD: 5312 BROADWAY | | CONT: 3-D HOMES | | TEL: (561)662-9327 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2005 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | 4TH ACTION: DENIED | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | 1B) INFORMATIONAL ONLY. PLEASE SUBMIT 2 OF ALL SURVEYS, | | PLANS, REPORTS, REVISIONS , PRODUCT APPROVALS AND OR | | SUBMITTALS FOR REVIEW FOR PERMIT. | | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF | | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A | | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID | | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* | | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH | | ADMINISTRATIVE CODE. | | | | 1C) INFORMATIONAL ONLY.106.1.1* W.P.B. ADMINISTRATIVE | | CODE/2004 DRAWINGS & SPECIFICATIONS SHALL CONTAIN | | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO | | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO | | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION | | SHALL BE SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE | | CITED AS A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR | | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | AFTER NOV. 21ST,2005 SHALL BE REVIEWED TO THE 2004 FBC | | BUILDING WITH THE2005 REVISIONS. | | | | 2-4) COMPLIED. | | | | 5) COMPLIED. | | | | 6-8) COMPLIED. | | | | 9) COMPLIED. | | | | 9B) SEMI-COMPLIED. THE NEWDOOR SWINGS INTO THE CLEAR | | FLOOR SPACE REQUIRED BY THE COMMON USE SINKS. | | | | 12-16) COMPLIED. | | | | 17A) SEMI-COMPLIED. PLANS STILL INDICATE WALLS THAT | | MAKE UP THE VERTICAL STAIR SHAFT THAT ARE NOT RATED. | | SEE SHAFTS 707.4. ALSO PROVIDE RATED DOORS FOR THE | | VERICAL EXIT ENCLOSURE. | | SEE 715.3. | | | | 18-21) COMPLIED. | | | | 22)COMPLIED. | | NEW COMMENTS | | 23)CORRIDOR WALLS AROUND THE FIRST AND SECOND FLOOR | | ASSEMBLY OCCUPANCIES THE PLANS DO NOT INDICATE AS RATED | | WALLS PLEASE SEE TABLE 1016.1. | | | | 24)PLANS WILL NEED TO CORRECT THEIR OCCUPANT COUNTS | | OFFICES ARE 100 SQ FT PER PERSON, AND FIRST FLOOR | | ASSEMBLY REWRITE 7 SQ FT PER PERSON. | | | | 25) THE SECOND FLOOR ONE EXIT IS OUT ONTO THE ROOF, AND | | DOWN AN EXIT STAIRWAY. THE PLANS SHOW A LINE THAT WOULD | | INDICATE A CHANGE IN ELEVATION ON THE ROOF. PLEASE | | PROVIDE | | WHAT CHANGE IN ELEVATION THIS IS? AND IF STAIRS WOULD | | BE REQUIRED. | | | | | | | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | BUILDING PLAN REVIEW II | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECODS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-04-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-04-05 |
Time |
10:16 |
Rev Time |
3.22 |
Received By |
jwitmer |
Date |
2007-04-05 |
Time |
09:19 |
Sent To |
|
|
Notes |
2007-04-05 10:22:51 | BUILDING PLAN REVIEW | | PERMIT: 06090243 | | ADD: 5312 BROADWAY | | CONT: 3-D HOMES, INC | | TEL: (561)662-9327 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | EX FL BLD CODE= 2004 EXISTING BUILDING | | CODE | | | | 2NDREVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2-8 COMPLIED. | | | | 9)SEE PLUMBING REQUIREMENTS FOR NEW RESROOM. | | | | 10-15) COMPLIED, | | | | 16) STAGE AND PLATFORMS, YOU CAN'T JUST QUOTE THE CODE | | SECTION, OF WHAT MATERIALS WILL THIS STAGE BE BUILT, | | WHAT IS THE SAFE BEARING LOAD OF THE STAGE? | | | | 17A) JANITORS CLOSET AT THE BASE OF STAIRS, 1019.1.5 TO | | BE 1 HR FIRE RATED PROVIDE WHAT ASSEMBLY TYPE WILL BE | | USED? | | | | 18) COMPLIED. | | | | 19) 2ND REQUEST, THE FIRST FLOOR INDICATEDA NEW | | PAIR OF EXTERIOR DOORS. | | 1609.1.4 PROTECTION OF OPENINGS. | | IN WIND-BORNE DEBRIS REGIONS, EXTERIOR | | GLAZING THAT RECEIVES POSITIVE PRESSURE | | IN THE LOWER 60 FEET (18.3 M) IN | | BUILDINGS SHALL BE ASSUMED TO BE | | OPENINGS AND THE BALANCE OF GLAZED | | OPENINGS IN THE REST OF THE BUILDING | | SHALL BE ASSUMED TO BE ZERO UNLESS SUCH | | GLAZING THAT RECEIVES POSITIVE PRESSURE | | IS IMPACT RESISTANT OR PROTECTED WITH AN | | IMPACT RESISTANT COVERING MEETING THE | | REQUIREMENTS OF SSTD 12, ASTM E 1886 AND | | ASTM E 1996, OR MIAMI-DADE TAS 201, 202 | | AND 203 REFERENCED THEREIN AS FOLLOWS: | | 1.GLAZED OPENINGS LOCATED WITHIN 30 | | FEET (9.1 M) OF GRADE SHALL MEET THE | | REQUIREMENTS OF THE LARGE MISSILE TEST. | | 2.GLAZED OPENINGS LOCATED MORE THAN | | 30 FEET (9.1 M) ABOVE GRADE SHALL MEET | | THE PROVISIONS OF THE SMALL MISSILE | | TEST. | | | | 1714.5.3 EXTERIOR DOOR ASSEMBLIES. | | EXTERIOR DOOR ASSEMBLIES NOT COVERED BY | | SECTION 1715.4.2 OR SECTION 1714.5.3.1 | | SHALL BE TESTED FOR STRUCTURAL INTEGRITY | | IN ACCORDANCE WITH ASTM E 330 PROCEDURE | | A, AT A LOAD OF 1.5 TIMES THE REQUIRED | | DESIGN PRESSURE LOAD. THE LOAD SHALL BE | | SUSTAINED FOR 10 SECONDS WITH NO | | PERMANENT DEFORMATION OF ANY MAIN FRAME | | OR PANEL MEMBER IN EXCESS OF 0.4 PERCENT | | OF ITS SPAN AFTER THE LOAD IS REMOVED. HIGH-VELOCITY | | HURRICANE ZONES SHALL | | COMPLY WITH TAS 202. AFTER EACH | | SPECIFIED LOADING, THERE SHALL BE NO | | GLASS BREAKAGE, PERMANENT DAMAGE TO | | FASTENERS, HARDWARE PARTS, OR ANY OTHER | | DAMAGE WHICH CAUSES THE DOOR TO BE | | INOPERABLE. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 20)FL BLD CODE 1609.1.4: COMPONENTS & | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | TESTING REPORTS,MISSING REPORTS ARE AS | | FOLLOWS: | | A) EXTERIOR SWING DOORS PROVIDE THE CORRECT REPORT THAT | | TIES TO THE FL REPORT# 4553/ THE REPORT SHOULD BE UL | | 4553 SEE PDF FILE! | | | | 21) 2ND REQUEST, WPB ADMIN CODE 106.3* PRODUCT | | APPROVALS. THOSE PRODUCT WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 22) THE NEW WING WALL ON THE BACK EXTERIOR OF BUILDING | | THAT SEPERATES THE 2ND FLOOR STAIR FROM THE NEW EXIT | | REAR OF CHURCH PROVIDES LESS THAN 44" CREATES BOTTLE | | NECKING EFFECT, CAN'T REDUCE THE EXIT FLOW. | | | | BUILDING PLAN REVIEW | | JIM WITMER C. B. O. | | | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-10-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-10-05 |
Time |
07:37 |
Rev Time |
5.50 |
Received By |
jwitmer |
Date |
2006-10-05 |
Time |
07:36 |
Sent To |
|
|
Notes |
2006-10-05 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 06090243 | | ADD: 5312 BROADWAY | | CONT: 3-D HOMES, INC | | TEL: (561)662-9327 | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | EX FL BLD CODE= 2004 EXISTING BUILDING | | CODE | | | | 1STREVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT BEFORE A | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | NOT ACTUALLY COMMENCED | | WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | 3) HOLDS ON PROPERTY: | | SEE ATTACHMENTHOLDS ON PROPERTY, WORKING | | | | WIWTHOUT PERMIT & CHANGE IN OCCUPANCY!!! | | | | 4) PLEASE CHANGE THE SCOPE OF WORK ON | | THE PERMIT APPLICATION UNDER DESCRIPTION | | OF WORK FOR THIS PROJECT TO REFLECT THE | | WORK COMPLETED WITHOUT BENEFIT OF A | | PERMIT AND FOR CHANGE OF OCCUPANCY ALSO | | REQUIRING A PERMIT.105.1*/306 EX FL BLD | | CODE. | | 3401.1 SCOPE. | | ALTERATION, REPAIR, ADDITION, RELOCATION | | AND CHANGE OF OCCUPANCY OF EXISTING | | STRUCTURES AND BUILDINGS SHALL COMPLY | | WITH THE PROVISIONS OF THE 2004 FLORIDA | | EXISTING BUILDING CODE . | | 1001.4 ALTERATIONS. | | A BUILDING SHALL NOT HEREAFTER BE | | ALTERED TO REDUCE THE CAPACITY OF THE | | MEANS OF EGRESS TO LESS THAN REQUIRED BY | | THIS CHAPTER NOR SHALL ANY CHANGE OF | | OCCUPANCY BE MADE IN ANY BUILDING UNLESS | | SUCH BUILDING CONFORMS WITH THE | | REQUIREMENTS OF THIS CHAPTER | | 13-101.3.2 BUILDINGS HAVING A CHANGE OF | | OCCUPANCY THAT WERE PERMITTED AFTER | | MARCH 15, 1979, SHALL COMPLY WITH THE | | REQUIREMENTS OF SUBCHAPTER 13-4 FOR | | COMMERCIAL APPLICATIONS AND | | MULTIPLE-FAMILY RESIDENTIAL BUILDINGS | | GREATER THAN THREE STORIES. | | THIS REVIEW WILL TAKE PLACE USING THE | | 2004 EXISTING BUILDING CODE & THE 2004 | | FL BUILDING CODE. THE LEVEL OF | | ALTERATIONS WILL BE CONSIDERED A LEVEL | | II ALTERATION. | | | | 5) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 6) NEW INFORMATION FROM THE | | ARCHITECTURAL BOARD ABOUT DRAFTING FIRMS | | | | WORKING UNDER THE LICENSE OF A DESIGN PROFESSIONAL. | | PLEASE SEE FL S S 481.229 | | AND THE ELECTRICAL COMMENT# 2. | | | | 7) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | THAT IS REQUIRED FOR RECORD | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | A) THE EDITION OFTHE CODE UNDER WHICH | | THE PERMIT WAS ISSUED. | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | WITH THE PROVISIONS OF CHAPTER 3. | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | IN CHAPTER 6, TABLE 601. | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | IS REQUIRED. | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | OF THE BUILDING PERMIT. | | G) NUMBER OF FLOORS | | H) NUMBER OF ROOMS | | I) SQ. FT. LIV SPACE/ FL | | J) SQ. FT. FOOTPRINT | | K) SQ. FT. UNDER ROOF (TOTAL) | | | | 8) AT THIS TIME NOT KNOWING IF THIS | | BUILDING HAS AUTOMATIC FIRE SPRINKLERS | | THE SECOND FLOOR WILL REQUIRE AREAS OF | | RESCUE ASSISTANCE. 105.1*, CHANGE OF | | OCCUPANCY INVOKES 11-4.1.6 ACCESSIBLE | | BUILDINGS: ALTERATIONS, | | (1)(B) IF EXISTING ELEMENTS, SPACES, OR | | COMMON AREAS ARE ALTERED, THEN EACH SUCH | | ALTERED ELEMENT, SPACE, FEATURE, OR AREA | | SHALL COMPLY WITH THE APPLICABLE | | PROVISIONS OF 11-4.1.1 T0 11-4.1.1 | | MINIMUM REQUIREMENTS FOR NEW | | CONSTRUCTION. | | 11-4.1.3(9)IN BUILDINGS OR | | FACILITIES, OR PORTIONS OF BUILDINGS OR FACILITIES, | | REQUIRED TO BE ACCESSIBLE, | | ACCESSIBLE MEANS OF EGRESS SHALL BE | | PROVIDED IN THE SAME NUMBER AS REQUIRED | | FOR EXITS BY LOCAL BUILDING/LIFE SAFETY REGULATIONS. | | WHERE A REQUIRED EXIT FROM | | AN OCCUPIABLE LEVEL ABOVE OR BELOW A | | LEVEL OF ACCESSIBLE EXIT DISCHARGE IS | | NOT ACCESSIBLE, AN AREA OF RESCUE | | ASSISTANCE SHALL BE PROVIDED ON EACH | | SUCH LEVEL (IN A NUMBER EQUAL TO THAT OF INACCESSIBLE | | REQUIRED EXITS). AREAS OF | | RESCUE ASSISTANCE SHALL COMPLY WITH | | SECTION 11-4.3.11 . A HORIZONTAL EXIT, | | MEETING THE REQUIREMENTS OF LOCAL | | BUILDING/LIFE SAFETY REGULATIONS, SHALL | | SATISFY THE REQUIREMENT FOR AN AREA OF | | RESCUE ASSISTANCE. | | 11-4.3.11.1 AREA OF RECUE ASSISTANCE | | LOCATION AND CONSTRUCTION SHALL MEET ALL | | THE REQUIREMENTS OF THIS SECTION, | | 11-4.3.11 (1)-(5). | | | | 9) THE NEW MENS RESTROOM LOCATED ON | | SHEET ONE DOESN,T MEET THE REQUIREMENTS | | OF 11-4.17.3. | | | | 10) PROVIDE A LIFE SAFETY PLAN FOR THE | | FIRST AND SECOND FLOORS. PROVIDE AN | | OCCUPANT LOAD FIRST AND SECOND FLOORS | | AND CAPACITY FOR EACH OF THE DOORWAYS | | STAIRS AND EXITS. ALSO INDICATE EXIT | | SIGNS AND DIRECTIONALS ON PLANS. 1023.1 | | | | 11) THE SHEET# 1 INDICATES FIRST FLOOR | | A CLOSET AT THE REAR OF THE CHURCH WITH | | A PAIR OF 3'-0" DOORS THE CORIDOR WITH | | IS 4'-6" OR 54" WIDE. THE DOORS TO THIS | | CLOSET BEING 36" LEAVING A CLEAR WITH OF | | 18". THE MINIMUM CLEAR WITH WIDTH | | REQUIRED IS 22" WITH AN OCCUPANT LOAD . | | 50. | | 1008.1.8.8 | | DURING ITS SWING, ANY DOOR IN A MEANS OF | | EGRESS SHALL LEAVE UNOBSTRUCTED AT LEAST | | ONE HALF OF THE REQUIRED WIDTH OF AN | | AISLE, CORRIDOR, PASSAGEWAY, OR LANDING, | | NOR PROJECT MORE THAN 7 INCHES (178 MM) | | INTO THE REQUIRED WIDTH OF AN AISLE, | | CORRIDOR, PASSAGEWAY OR LANDING, WHEN | | FULLY OPEN. | | | | 12) SHEET# 1 LOWER LEFT CORNER OF PLAN, | | THE HALLWAYS LEAD TO A PAIR OF 2 2'-6 | | DOORS, IT APPEARS THE CORRIDOR IS LESS | | THAN 44" WIDE.1016.2. | | | | 13) SHEET# 1 LOWER LEFT CORNER OF THE | | PLAN DOUBLE DOORS : | | 11-4.13.4 DOUBLE-LEAF DOORWAYS. | | IF DOORWAYS HAVE TWO INDEPENDENTLY | | OPERATED DOOR LEAVES, THEN AT LEAST ONE | | LEAF SHALL MEET THE SPECIFICATIONS IN | | SECTION 11-4.13.5 AND SECTION 11-4.13.6 | | . THAT LEAF SHALL BE AN ACTIVE LEAF. | | 11-4.13.5 CLEAR WIDTH. | | DOORWAYS SHALL HAVE A MINIMUM CLEAR | | OPENING OF 32 INCHES (813 MM) WITH THE | | DOOR OPEN 90 DEGREES, MEASURED BETWEEN | | THE FACE OF THE DOOR AND THE OPPOSITE | | STOP [SEE FIGURE 11-24 (A), FIGURE 11-24 | | (B), FIGURE 11-24 (C), AND FIGURE 11-24 | | (D)]. | | | | 14) SHEET# 1 LOWER LEFT CORNER THE PAIR | | OF DOORS LABELED # 4 TO THE EXTERIOR | | BLOCK THE 2ND STORY EXIT STAIRS AS | | INDICATED.THE PLANS INDICATE NEW DOORS, | | WHAT IS THE CHANGE IN FLOOR ELEVATION TO | | THE EXTERIOR? | | | | 15) SHEET# 1 FRONT ENTRY DOOR SWINGS THE | | WRONG WAY, 1008.1.2DOORS SHALL SWING | | IN THE DIRECTION OF EGRESS TRAVEL WHERE | | SERVING AN OCCUPANT LOAD OF 50. | | | | 16) STAGES AND PLATFORMS | | 410.3.1 STAGE CONSTRUCTION. | | STAGES SHALL BE CONSTRUCTED OF MATERIALS | | AS REQUIRED FOR FLOORS FOR THE TYPE OF CONSTRUCTION OF | | THE BUILDING IN WHICH | | SUCH STAGES ARE LOCATED. | | EXCEPTIONS: | | 1.STAGES OF TYPE IIB OR IV | | CONSTRUCTION WITH A NOMINAL 2-INCH (51 | | MM) WOOD DECK, PROVIDED THAT THE STAGE | | IS SEPARATED FROM OTHER AREAS IN | | ACCORDANCE WITH SECTION 410.3.4 . | | 2.IN BUILDINGS OF TYPE IIA, IIIA | | AND VA CONSTRUCTION, A | | FIRE-RESISTANCE-RATED FLOOR IS NOT | | REQUIRED, PROVIDED THE SPACE BELOW THE | | STAGE IS EQUIPPED WITH AN AUTOMATIC FIRE-EXTINGUISHING | | SYSTEM IN ACCORDANCE | | WITH SECTION 903 OR 904. | | 3.IN ALL TYPES OF CONSTRUCTION, THE | | FINISHED FLOOR SHALL BE CONSTRUCTED OF | | WOOD OR APPROVED NONCOMBUSTIBLE | | MATERIALS. OPENINGS THROUGH STAGE FLOORS | | SHALL BE EQUIPPED WITH TIGHT-FITTING, | | SOLID WOOD TRAP DOORS WITH APPROVED | | SAFETY LOCKS. | | PROVIDE CLARITY AND COMPLIANCE WITH | | THESE SECTIONS OF THE CODE. | | | | 17A) SHEET# 1 EAST SIDE OF THE BUILDING | | PLEASE PROVIDE CLAARITY ON THE JANITORS | | CLOSET LOCATED BENEATH THE STAIRWAY WITH | | A RETURN DUCT ? | | 1019.1.5 ENCLOSURES UNDER STAIRWAYS. | | THE WALLS AND SOFFITS WITHIN ENCLOSED | | USABLE SPACES UNDER ENCLOSED AND | | UNENCLOSED STAIRWAYS SHALL BE PROTECTED | | BY 1-HOUR FIRE-RESISTANCE-RATED | | CONSTRUCTION, OR THE FIRE-RESISTANCE | | RATING OF THE STAIRWAY ENCLOSURE, | | WHICHEVER IS GREATER. ACCESS TO THE | | ENCLOSED USABLE SPACE SHALL NOT BE | | DIRECTLY FROM WITHIN THE STAIR | | ENCLOSURE. | | | | 17B) IS THERE RATINGS BETWEEN THE | | JANITORS CLOSET AND STAIR FRAMING? | | | | 18A) SHEET# 2 EXISTING MEETING ROOM HAS | | 607 SQ FT AND A OCCUPANT LOAD OF 96. TWO | | MEANS OF EGRESS ARE REQUIRED FOR THIS | | AREA.TABLE 1014.1. | | | | 18B)1014.2.1 TWO EXITS OR EXIT ACCESS | | DOORWAYS. | | WHERE TWO EXITS OR EXIT ACCESS DOORWAYS | | ARE REQUIRED FROM ANY PORTION OF THE | | EXIT ACCESS, THE EXIT DOORS OR EXIT | | ACCESS DOORWAYS SHALL BE PLACED A | | DISTANCE APART EQUAL TO NOT LESS THAN | | ONE-HALF OF THE LENGTH OF THE MAXIMUM | | OVERALL DIAGONAL DIMENSION OF THE | | BUILDING OR AREA TO BE SERVED MEASURED | | IN A STRAIGHT LINE BETWEEN EXIT DOORS OR | | EXIT ACCESS DOORWAYS. INTERLOCKING OR | | SCISSOR STAIRS SHALL BE COUNTED AS ONE | | EXIT STAIRWAY. | | EXCEPTIONS: | | 1.WHERE EXIT ENCLOSURES ARE | | PROVIDED AS A PORTION OF THE REQUIRED | | EXIT AND ARE INTERCONNECTED BY A 1-HOUR | | FIRE-RESISTANCE-RATED CORRIDOR | | CONFORMING TO THE REQUIREMENTS OF | | SECTION 1016 , THE REQUIRED EXIT | | SEPARATION SHALL BE MEASURED ALONG THE | | SHORTEST DIRECT LINE OF TRAVEL WITHIN | | THE CORRIDOR. | | 2.WHERE A BUILDING IS EQUIPPED | | THROUGHOUT WITH AN AUTOMATIC SPRINKLER | | SYSTEM IN ACCORDANCE WITH SECTION | | 903.3.1.1 OR 903.3.1.2 , THE SEPARATION | | DISTANCE OF THE EXIT DOORS OR EXIT | | ACCESS DOORWAYS SHALL NOT BE LESS THAN | | ONE-THIRD OF THE LENGTH OF THE MAXIMUM | | OVERALL DIAGONAL DIMENSION OF THE AREA | | SERVED. | | | | 18C) DEPENDING ON THE LOCATION WHERE THE | | SECOND MEANS OF EGRESS IS CUT IN ON THE | | EXISTING MEETING ROOM WITH AN OCCUPANT | | LOAD OF 96 THE DOOR LEADING TO THE | | PRAYER ROOM WILL ALSO NEED TO HAVE THE | | SWING REVERSED, 1008.1.2: DOORS SHALL | | SWING IN THE DIRECTION OF EGRESS TRAVEL | | WHERE SERVING AN OCCUPANT LOAD OF 50 OR | | GREATER. | | | | 19) THE FIRST FLOOR INDICATEDA NEW | | PAIR OF EXTERIOR DOORS. | | 1609.1.4 PROTECTION OF OPENINGS. | | IN WIND-BORNE DEBRIS REGIONS, EXTERIOR | | GLAZING THAT RECEIVES POSITIVE PRESSURE | | IN THE LOWER 60 FEET (18.3 M) IN | | BUILDINGS SHALL BE ASSUMED TO BE | | OPENINGS AND THE BALANCE OF GLAZED | | OPENINGS IN THE REST OF THE BUILDING | | SHALL BE ASSUMED TO BE ZERO UNLESS SUCH | | GLAZING THAT RECEIVES POSITIVE PRESSURE | | IS IMPACT RESISTANT OR PROTECTED WITH AN | | IMPACT RESISTANT COVERING MEETING THE | | REQUIREMENTS OF SSTD 12, ASTM E 1886 AND | | ASTM E 1996, OR MIAMI-DADE TAS 201, 202 | | AND 203 REFERENCED THEREIN AS FOLLOWS: | | 1.GLAZED OPENINGS LOCATED WITHIN 30 | | FEET (9.1 M) OF GRADE SHALL MEET THE | | REQUIREMENTS OF THE LARGE MISSILE TEST. | | 2.GLAZED OPENINGS LOCATED MORE THAN | | 30 FEET (9.1 M) ABOVE GRADE SHALL MEET | | THE PROVISIONS OF THE SMALL MISSILE | | TEST. | | | | 1714.5.3 EXTERIOR DOOR ASSEMBLIES. | | EXTERIOR DOOR ASSEMBLIES NOT COVERED BY | | SECTION 1715.4.2 OR SECTION 1714.5.3.1 | | SHALL BE TESTED FOR STRUCTURAL INTEGRITY | | IN ACCORDANCE WITH ASTM E 330 PROCEDURE | | A, AT A LOAD OF 1.5 TIMES THE REQUIRED | | DESIGN PRESSURE LOAD. THE LOAD SHALL BE | | SUSTAINED FOR 10 SECONDS WITH NO | | PERMANENT DEFORMATION OF ANY MAIN FRAME | | OR PANEL MEMBER IN EXCESS OF 0.4 PERCENT | | OF ITS SPAN AFTER THE LOAD IS REMOVED. HIGH-VELOCITY | | HURRICANE ZONES SHALL | | COMPLY WITH TAS 202. AFTER EACH | | SPECIFIED LOADING, THERE SHALL BE NO | | GLASS BREAKAGE, PERMANENT DAMAGE TO | | FASTENERS, HARDWARE PARTS, OR ANY OTHER | | DAMAGE WHICH CAUSES THE DOOR TO BE | | INOPERABLE. | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 20)FL BLD CODE 1609.1.4: COMPONENTS & | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | TESTING REPORTS,MISSING REPORTS ARE AS | | FOLLOWS: | | A) EXTERIOR SWING DOORS | | | | 21) WPB ADMIN CODE 106.3* PRODUCT | | APPROVALS. THOSE PRODUCT WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 22) PROVIDE AN INTERIOR WALL & CEILING | | SCHEDULE BASED ON OCCUPANCY TABLE 803.5. | | | | | | NOTE THE NEXT REVIEW MAY HAVE ADDITIONAL | | COMMENTS DUE TO THE DESIGN TEAMS | | RESPONCE TO THE FIRST REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2008-07-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-07-28 |
Time |
09:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-07-28 |
Time |
09:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2008-01-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-01-12 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-01-12 |
Time |
17:17 |
Sent To |
|
|
Notes |
2008-01-12 17:18:31 | *** TEMPORARY FAILED STATUS **** | | | | *** TEMPORARY FAILED STATUS *** | | | | 1) NOTE: ELECTRICAL PLANS ARE OK, HOWEVER THE FORM 400C | | SUBMITTED IS REQUIRED TO BE SIGNED, DATED AND SEALED BY | | THE DESIGNER AND ENGINEER OF RECORD. | | PLEASE ALSO VERY LIGHTING DENSITIES SHOWN ON 400C WITH | | THAT OF THE LIGHTING SHOWN ON PLANS. | | | | FBC 13-103.1.1.1, FS 471.025 AND FAC 61G15-23.002, | | 61G15-33.004 | | | | PLEASE KNOW THE ABOVE MAY BE SUBMITTED AT ANYTIME | | BEFORE OTHER REVIEWS ARE COMMENCED. PLEASE CONTACT THIS | | REVIEWER AS THESE NEED TO BE SUBMITTED AS SOON AS | | POSSIBLE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2007-10-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-10-16 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-10-16 |
Time |
14:37 |
Sent To |
|
|
Notes |
2007-10-16 15:21:39 | | | *** DENIED 3RD REVIEW ***** | | | | ** PLEASE SEE COMMENTS FROM PREVIOUS REVIEWS STILL NEED | | TO BE ADDRESSED. | | THERE ARECOMMENTS BELOW WHICH STILL NEED TO BE | | ADDRESSED. ONCE ALL REVIEWS ARE DONE AND IF ALL REVIEWS | | ARE IN A *PASSED* STATUS, PLEASE CONTACT THIS | | REVIEWER. | | IF PLANS COME BACK WITH COMMENTS FROM ANY OTHER TRADES, | | THESE MUST BE ADDRESSED AT THIS TIME. | | | | 1) NOTE: PLEASE SEE AS STATED AND REQUESTED ON THE | | PREVIOUS REVIEWS. PLEASE SUBMIT LIGHTING PHOTO-METRIC | | LEVELS FOR STAIRS UNDER NORMAL AND EMERGENCY | | CONDITIONS. PLEASE SEE NFPA-101 (LIFE SAFETY CODE) | | 7.8.1.3, 7.9.2.2 WHICH WAS GIVEN ON PREVIOUS | | REVIEW(S). | | PLEASE SEE MINIMUM LEVELS ARE REQUIRED ALSO PER FLORIDA | | ADMINISTRATIVE CODE 61G15-33.004 | | | | 2) NOTE: PLEASE SEE THIS SAME LIFE SAFETY CODE AND FBC | | CHAPTER 10 AS OCCUPANCY SENSOR DEVICES MAY BE USED FOR | | CONTROL OF LIGHTING HOWEVER A MINIMUM OF TWO DEVICES IN | | STAIR AREA WOULD BE REQUIRED FOR CONTROL OF LIGHTING | | FIXTURES. THE FAILURE OF ANY ONE DEVICE FOR CONTROL OF | | EGRESS LIGHTING CAN NOT LEAVE NAY ONE AREA IN DARKNESS | | UNDER NORMAL OR EMERGENCY CONDITIONS. | | | | 3) NOTE: PLEASE SEE RISER AND PANEL MDP WHICH INDICATES | | 150AMP OVER CURRENT PROTECTION FEEDING A 100AMP | | DISCONNECT AND CONTROL PANEL FOR ELEVATOR. | | | | ** FOR INFORMATION ONLY, THE RECORDED NOC SUBMITTED HAS | | EXPIRED PER FS 713.13(2). | | WILL NEED ONLY TO BE RE-RECORDED ONCE PICKING UP | | PERMIT. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | SHOULD BE SUBMITTED FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | DELAYS. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2007-03-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-03-18 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-03-18 |
Time |
12:13 |
Sent To |
|
|
Notes |
2007-03-18 14:09:15 | ** UNSAT ** | | | | ** PLEASE KNOW THAT THIS IS A CHANGE IN OCCUPANCY AND | | ALL ELECTRICAL WILL BE REQUIRED TO MEET THE CURRENT | | CODES ADOPTED WHEN PERMIT WAS APPLIED. | | THE PERMIT DESCRIPTION ON COMPUTER NOW INDICATES BUILD | | OUT FOR NEW CHURCH. | | | | *********************************** | | ** PLEASE SEE PLANS ARE STAMPED FROM PALM BEACH COUNTY | | FOR IMPACT FEES WHICH INDICATE *EXISTING* USEAND | | PLANS SUBMITTED TO PALM BEACH COUNTY ALSO INDICATE | | EXISTING USE AS A CHURCH. PLEASE KNOW THIS WILL BE | | FORWARD TO PALM BEACH COUNTY FOR THIS USE AS NEW AS IT | | IS NOT EXISTING. | | *************************************** | | | | 1) NOTE: PLEASE SEE THAT ALL OF THE CODES WHICH PLANS | | ARE UNDER DESIGN AND RECORD SHALL BE STATED ON PLANS AS | | FOLLOWS. | | 2004 FBC | | 2002 NFPA-70 | | 2003 NFPA-101 | | 2002 NFPA-72 | | ** THESE ARE REQUIRED FOR THE REVIEWER AT A MINIMUM AND | | OTHER CODES WILL BE REQUIRED FOR OTHER TRADES. | | | | 2) NOTE: PLEASE SEE MISSING CERTIFICATE OF | | AUTHORIZATION NUMBER ON TITLE BLOCKS FOR THE COMPANY | | LISTED AS MCR PROFESSIONAL ENGINEERING INC. PLEASE SEE | | SHEET IS ATTACHED FROM THE DEPARTMENT OF BUSINESS AND | | PROFESSIONAL REGULATION WITH THE LICENSE INFORMATION AS | | NEED. PLEASE SEE THE FLORIDA ADMINISTRATIVE CODE | | 61G15-23.002 AND FLORIDA STATUTES 471.023. | | | | 3) NOTE: PLEASE SEE FBC CHAPTER 13. | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND .1.3. PLEASE SEE | | SOME AREAS WHICH DO NOT INDICATE ANY LIGHTING CONTROLS. | | PLEASE SEE AREAS OF STAIRS WHICH WILL ALSO BE NOTED IN | | ANOTHER NOTE FOR LIFE SAFETY AND EGRESS WHICH WILL BE | | REQUIRED TO CONTAIN A AUTOMATED DEVICE FOR OCCUPANTS | | WHERE SWITCHED. | | PLEASE VERIFY THE COVERAGE ON THE DEVICES AS NOTED AS | | THE COVERAGE IN LARGER BATHROOMS WHICH CONTAIN MULTIPLE | | STALLS AND ALSO HALLWAY AREAS WHICH INDICATE WALL | | MOUNTED DEVICES. PLEASE VERIFY IF THESE DEVICES AS | | SHOWN WILL PROVIDE THE COVERAGE AS NEEDED. | | PLEASE SEE 13-415.1.ABC.3 FOR TANDEM WIRING. | | PLEASE SEE 13-415.1.AB.1, PLEASE SEE MISSING ENERGY | | CALCULATIONS FOR BUILD OUT OF NEW CHURCH. | | PLEASE SEE 13-415.2 AS LIGHTING POWER DENSITIES ARE NOT | | INDICATED FOR ALL AREAS. PLEASE BE SURE TO CORRELATE | | THIS WITH THE ENERGY CALCULATIONS WHICH ARE TO BE | | SUBMITTED. | | * PLEASE SEE ALL OF CHAPTER 13. | | 13-103.1.1.1 | | | | 4) NOTE: PLEASE SEE THE VALUE FOR THE COMPLETE SCOPE OF | | WORK NEEDS TO BE DECLARED. UNABLE TO VERIFY AT THIS | | TIME. BASED ON THE SCOPE OF ELECTRICAL WORK AND OTHER | | TRADES THE APPLIED VALUE IS LOW. PLEASE SEE FBC 108.3 | | ADMIN SECTION. | | | | 5) NOTE: PLEASE CORRELATE ELECTRICAL PLANS AND RISER | | FOR THE ELECTRICAL SERVICE AS SHOWN AND NOTED. PLEASE | | KNOW THERE ARE MANY NOTES ON PLANS TO VERIFY SERVICE, | | CONDUCTORS, AND FEEDERS ETC. PLEASE KNOW THAT ALL THE | | VERIFICATION IS REQUIRED BEFORE PERMIT ISSUANCE AND | | SHALL BE STATED ON PLANS AS REQUIRED FOR NEW BUILD | | OUT. | | PLEASE SEE RISER MENTIONS NEW PANELS, YET MDP MENTIONS | | PANELS AS EXISTING? | | THESE ARE PANELS WHICH WERE INSTALLED WITHOUT PERMITS, | | THEY SHALL BE INCLUDED AS *NEW* ON THESE RECORD SETS OF | | PLANS. | | PLEASE SEE MDP AND PLANS DO NOT MATCH AND PROVIDE | | ENOUGH INFORMATION FOR THE PANELS SHOWN FOR AIR | | HANDLING UNITS 1,2 AND 3. | | (PLEASE ALSO SEE THE NEXT COMMENT #6.) | | PLEASE CLARIFY SEVERAL PANELS ON PLANS WHICH MENTIONS | | *EXIST PANEL, NOT USED*? PLEASE SEE NO INFORMATION IS | | PROVIDED FOR THESE AND WHETHER OR NOT THESE PANELS ARE | | BEING REMOVED? PLEASE INDICATE IF THEY. PLEASE INDICATE | | IF THEY ARE BEING REMOVED, IF NOT THEN PLEASE INCLUDE | | ON PANEL SCHEDULES, PLANS, RISER ETC. | | | | 6) NOTE: PLEASE CORRELATE ALL LOADS FOR AIR | | CONDITIONING EQUIPMENT. PLEASE SEE THE LOAD | | CALCULATIONS INDICATE A TOTAL OF 27KVA, YET THE PANEL | | SCHEDULE FOR PANEL *B* ALONE SHOWS 30KVA FOR A/C | | EQUIPMENT. PLEASE SEE THE LOAD ON CIRCUIT 1 ON THE MDP | | INDICATES 18KVA WHICH EXCEEDS THE RATING OF THE OVER | | CURRENT PROTECTION DEVICE AS SHOWN FEEDING AHU 1, 2 AND | | 3? | | PLEASE SEE NOTE ABOVE AS INFORMATION FOR THE FEEDERS | | ETC TO THE AHU PANELS NEEDS TO BE SUBMITTED FOR REVIEW. | | NOT ENOUGH INFORMATION IS SUBMITTED FOR FULL REVIEW OF | | CODE COMPLIANCE. | | NEC 220, 424.3, 215.5, ETC. | | FBC 106.3.5.1.2, 106.1.2 | | ** PLEASE ALSO VERIFY THE CONDENSING UNITS WHICH ARE | | SHOWN AS 3-PHASE AND AIR HANDLING UNITS AS SINGLE PHASE | | AND CONDENSING UNITS BEING SHOWN AS 3-PHASE WITH AIR | | HANDLING UNITS TO A SINGLE PHASE PANEL?? | | | | 7) NOTE: PLEASE PROVIDE ALL CIRCUITING ON PANEL | | SCHEDULES FOR ALL ROOMS AND AREAS WHICH THE CIRCUIT | | FEEDS. PLEASE SEE 408.4 AND COMMENTARY WHICH IS TAKEN | | FROM THE CODE. | | * CODE TO REQUIRE THAT THE IDENTIFICATION FOR EVERY | | CIRCUIT SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE | | LEGIBLE AND CLEARLY STATE THE SPECIFIC PURPOSE FOR | | WHICH THE CIRCUIT IS USED. CIRCUITS USED FOR THE SAME | | PURPOSE MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR | | EXAMPLE, SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY | | OUTLETS IN THE KITCHEN, DINING ROOM, AND KITCHEN | | COUNTERTOPS. IDENTIFYING THE CIRCUITS AS SMALL | | APPLIANCE BRANCH CIRCUITS IS NOT ACCEPTABLE; INSTEAD, | | THEY SHOULD BE IDENTIFIED AS ``KITCHEN WALL | | RECEPTACLES,'' ``DINING ROOM FLOOR RECEPTACLE,'' OR | | ``KITCHEN COUNTERTOP RECEPTACLES LEFT OF SINK.'' | | CIRCUIT DIRECTORIES CONTAINING MULTIPLE ENTRIES WITH | | ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT PROVIDE THE | | SUFFICIENT DETAIL REQUIRED BY THIS SECTION.* | | 408.4, 310.16, 240.4 ETC | | FBC 106.3.5.4 | | | | 8) NOTE: PLEASE SUBMIT COMPLETE PHOTO-METRICS FOR ALL | | EGRESS PATHS MEETING NFPA-101 7.8 AND 7.9. | | PLEASE SEE 7.8.1.3 AND 7.9.2.2 FOR STAIR AREAS. | | PLEASE SHOW LIGHTING LEVELS UNDER NORMAL AND EMERGENCY | | CONDITIONS. | | PLEASE ALSO SEE NOTE ABOVE WITH RESPECT TO CONTROLS FOR | | LIGHTING WHICH SHALL NOT LEAVE ANY ONE AREA IN TOTAL | | DARKNESS BASED ON THE SWITCHING OF A DEVICE, TRIPPING | | OF A BREAKER ETC. | | PLEASE SEE BUILDING COMMENTS FOR POSSIBLE 2ND MEANS OF | | EGRESS WHICH MAY BE REQUIRED. PLEASE KNOW ANY OTHER | | EGRESS PATH FROM SECOND FLOOR WHICH MAY APPEARS TO | | PLACE OCCUPANTS OVER A ROOF AREA AND THEN TO STAIRS ON | | THE OUTSIDE OF A BUILDING LEADING TO THE PUBLIC RIGHT | | OF WAY BELOW. | | PLEASE PROVIDE LIGHTING AS REQUIRED FOR THESE AREAS. | | PLEASE INDICATE NORMAL AND EMERGENCY FOR STAGE AREA AND | | STAIRS FROM THIS AREA. | | | | 9) NOTE: PLEASE SEE 620.23, 620.24 WHICH REQUIRES | | DEDICATED CIRCUITS FOR ELEVATOR LIGHTS/RECEPTACLES AND | | ELEVATOR EQUIPMENT ROOMS. PLEASE SEE THAT SOME OF THIS | | IS DONE; HOWEVER PLEASE SEE THAT THESE CIRCUITS MAY NOT | | FEED ANY OTHER AREAS. | | PLEASE ALSO INDICATE AN EMERGENCY LIGHT FIXTURE OF SOME | | KIND IN ELEVATOR EQUIPMENT ROOM. 700.12E, 700.16, LS | | 7.8, 7.9 AND STATE ELEVATOR CODE. | | | | 10) NOTE: PLEASE INDICATE HOW LIGHTING AND RECEPTACLE | | LOADS ARE DERIVED. PLEASE SEE 220.3, 220.10, 220.11, | | 220.13 ETC. | | | | 11) NOTE: PLEASE PLACE INFORMATION ON SYMBOL LEGEND FOR | | HORN AND STROBE DEVICES FOR FBC 2004 ADA LEVELS. | | 11-4.28.1, .2 AND .3(4). | | PLEASE SEE THERE ARE SEVERAL DIFFERENCES IN THE POWER | | PLANS COMPARED TO THE LIGHTING PLANS FOR DEVICE | | LOCATIONS. | | PLEASE ALSO SEE 11-4.28.1 AS THERE IS MANY LOCATIONS | | /ROOMS/AREAS WHICH DO NOT INDICATE ANY DEVICES. | | | | 12) NOTE: PLEASE CORRELATE ALL ARCHITECTURAL SHEETS | | WITH THE ELECTRICAL PLANS AS THERE ARE PANELS NOTED ON | | OTHER SHEETS WHICH DO NOT CORRELATE WITH ELECTRICAL FOR | | SIZES ETC. | | FBC 106.1.2, 106.3.5.1.2. | | | | 13) NOTE: PLEASE SEE TITLE BLOCKS WHICH CONTAINS | | *WHITE-OUT* OVER THE DRAFTING FIRM, PLEASE DO NOT USE | | WHITE OUT ON PLANS AND REMOVE THE TITLE BLOCKS WHEN | | REVISING PLANS. | | FS 471/481 | | | | ** PLEASE COMPLETE, CORRELATE AND SUBMIT PLANS FOR | | REVIEW. | | ** PLEASE KNOW AT THIS TIME, BASED ON MANY ITEMS WHICH | | CAN NOT BE REVIEWED FOR CODE COMPLIANCE, THERE MAY VERY | | WELL BE NEW COMMENTS ON THE FOLLOWING REVIEW WHICH ARE | | NOT ON THIS REVIEW AT THIS TIME. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-09-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-09-17 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-09-17 |
Time |
15:50 |
Sent To |
|
|
Notes |
2006-09-17 00:00:00 | ********UNSAT ************ | | | | 1) NOTE: PLEASE SUBMIT COMPLETE | | ELECTRICAL PLANS FOR THIS BUILDING AS | | THIS WAS A CHANGE IN OCCUPANCY WHICH WAS | | NEVER PERMITTED. PLEASE SEE PERMIT | | APPLICATIONS WHICH WERE PLACED ON "HOLD" | | AND/VOIDED IN 2005. | | PLEASE SEE PLANS MENTIONS PANELS SHOWN | | AS EXISTING, HOWEVER THESE WERE NEVER | | PERMITTED. | | | | ** PLEASE SEE 2004 FBC , 2002 NFPA-70, | | NFPA-72 2002, NFPA-101 2003. | | | | 2) NOTE: PLEASE KNOW AS VALUE FOR SCOPE | | OF WORK WILL EXCEED $25K, THE SCOPE OF | | MUST BE DONE BY AN ARCHITECT OR ENGINEER | | AND A "DRAFTING FIRM" MAY NOT DO | | COMMERICAL PLANS OVER $25K. | | PLEASE CONTACT THE FLORIDA BOARD OF | | ARCHITECTS AND/OR LEGAL COUNSEL TO THE | | BOARD. | | FS 481.229. | | | | 3) NOTE: PLEASE SEE PERMIT APPLICATION | | SHOWN MENTIONS ONLY REPLACING AN | | EXTERIOR DOORS, HOWEVER PLANS INDICATES | | BATH RMS ETC . PLEASE SEE NOTE ABOVE | | WHICH WILL ALSO REQUIRE COMPLETE PLANS | | FOR CHANGE. | | PLEASE SEE FBC AND NFPA-70, 101 ETC FOR | | ASSEMBLY OCCUPANCIES. | | | | ONE SET OF PLANS IS BEING RETAINED BY | | THIS OFFICE. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2008-11-07 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2008-11-07 |
Time |
10:23 |
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2008-11-07 10:22:51 | APPROVED WITH PROVISO. | | PROVIDE SILT FENCE AROUND SITE CONSTRUCTIONS AREA. MUST | | COMPLY WITH NPDES. | | MANNY GONZALEZ, PROJEC COORDINATOR, ENGINEERING | | SERVICES (561) 494-1085 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2008-07-18 |
|
|
Cont ID |
|
Sent By |
rchokshi |
Date |
2008-07-18 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
rchokshi |
Date |
2008-07-18 |
Time |
10:55 |
Sent To |
B |
|
Notes |
2008-07-18 10:56:55 | FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE SHOW ON DRAWING THE DUMPSTER LOCATION WITH | | THE MINIMUM DIMENSIONS OF THE DUMPSTER PAD APPROVED BY | | THE CITY. | | OUR RESPONSE :O.K | | | | 2. DUMPSTER DIMENSIONS MUST MEET MINIMUM LENGTH, WIDTH, | | & HEIGHT PER CITY STANDARDS. | | | | ADUMPSTER SKETCH WITH MINIMUM DIMENSION CAN BE | | FOUND AT THE CITY'S WEB PAGE AT | | HTTP://EXCITINGCITY.COM/ENGINEERING/ENG_STANDARDS.HTM | | IF YOU CAN NOT MEET MINIMUM DIMENSIONS, NEED A LETTER | | FROM SANITATION DEPT APPROVING ALTERNATE ARRANGEMENT. | | | | OUR RESPONSE: O.K. | | | | 3.DUMPSTER LOCATIONMUST BE ACCESSIBLE TO CITY | | COLLECTION TRUCK FOR LOADING/UNLOADING DUMPSTER. | | | | OUR RESPONSE: O.K. | | | | YOU STILL NEED TO PROVIDE THE RESPONSE FOR THE | | FOLLOWING ITEMS 4 &5 ASKED BY JONATHAN BRAMLEY, | | DIRECTOR | | | | 4. SHT 1 PROVIDES ADDITIONAL INFORMATION ON THE | | PROPOSED PARKING LAYOUT.AS REFERENCED ABOVE IT IS NOT | | CLEAR THAT THE CORRECT DUMPSTER ENCLOSURE CAN BE | | PROVIDED IN THE LOCATION THAT IS SUGGESTED. | | | | 5. PLEASE PROVIDE EXISTING GRADES AND CURRENT FLOW | | LINES ON THE EXISTING SITE DETAIL.ON THE PROPOSED | | LAYOUT PLEASE SHOW EXISTING GRADES OR FINAL GRADES,IF | | THEY WILL CHANGE, TO DEMONSTRATE THAT ALL FLOWS WILL | | REMAIN ON SITE AND FLOW IS INTO THE IMPOUND AREAS TO | | SUPPORT THE PROPOSED DRAINAGE STATEMENT. | | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | SHEET. IF PRACTICING THROUGH A DULY | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | THEIR NAME AND LICENSE NUMBER, AS WELL | | AS, THE NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION | | NUMBER OF THE ENGINEERING | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | WILL SATISFY THIS REQUIREMENT. FAC | | 61G15-23.002(2) - FS 471.025 | | | | | | PLEASE RE SPOND ABOVE COMMENTSIN DETAIL TO EXPEDITE | | YOUR PERMIT | | | | JONATHAN BRAMLEY - FOR RASIK CHOKSHI805-6723 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2008-02-05 |
|
|
Cont ID |
|
Sent By |
jbramley |
Date |
2008-02-05 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
jbramley |
Date |
2008-02-05 |
Time |
14:55 |
Sent To |
|
|
Notes |
2008-02-05 15:22:30 | FAILED FOR FOLLOWING REASONS: | | | | | | 1. PLEASE SHOW ON DRAWING THE DUMPSTER LOCATION WITH | | THE MINIMUM DIMENSIONS OF THE DUMPSTER PAD APPROVED BY | | THE CITY. | | 2. DUMPSTER DIMENSIONS MUST MEET MINIMUM LENGTH, WIDTH, | | & HEIGHT PER CITY STANDARDS. | | ADUMPSTER SKETCH WITH MINIMUM DIMENSION CAN BE | | FOUND AT THE CITY'S WEB PAGE AT | | HTTP://EXCITINGCITY.COM/ENGINEERING/ENG_STANDARDS.HTM | | IF YOU CAN NOT MEET MINIMUM DIMENSIONS, NEED A LETTER | | FROM SANITATION DEPT APPROVING ALTERNATE ARRANGEMENT. | | 3.DUMPSTER LOCATIONMUST BE ACCESSIBLE TO CITY | | COLLECTION TRUCK FOR LOADING/UNLOADING DUMPSTER. 4. SHT | | 1 PROVIDES ADDITIONAL INFORMATION ON THE PROPOSED | | PARKING LAYOUT.AS REFERENCED ABOVE IT IS NOT CLEAR | | THAT THE CORRECT DUMPSTER ENCLOSURE CAN BE PROVIDED IN | | THE LOCATION THAT IS SUGGESTED. | | 5. PLEASE PROVIDE EXISTING GRADES AND CURRENT FLOW | | LINES ON THE EXISTING SITE DETAIL.ON THE PROPOSED | | LAYOUT PLEASE SHOW EXISTING GRADES OR FINAL GRADES,IF | | THEY WILL CHANGE, TO DEMONSTRATE THAT ALL FLOWS WILL | | REMAIN ON SITE AND FLOW IS INTO THE IMPOUND AREAS TO | | SUPPORT THE PROPOSED DRAINAGE STATEMENT. | | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | SHEET. IF PRACTICING THROUGH A DULY | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | THEIR NAME AND LICENSE NUMBER, AS WELL | | AS, THE NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION | | NUMBER OF THE ENGINEERING | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | WILL SATISFY THIS REQUIREMENT. FAC | | 61G15-23.002(2) - FS 471.025 | | | | | | PLEASE RE SPOND ABOVE COMMENTSIN DETAIL TO EXPEDITE | | YOUR PERMIT | | | | JONATHAN BRAMLEY - FOR RASIK CHOKSHI805-6723 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2008-08-05 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-08-05 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-08-05 |
Time |
14:31 |
Sent To |
|
|
Notes |
2008-08-05 14:49:20 | *****APPROVED***** | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | BEEN ADDRESSED;PLAN SHEETS 1.2, 5.1, AND 6.1 WHICH | | PEVIOUSLY STAMPED ON 2/13/08 WERE RESTAMPED, INITIALED, | | AND DATED.E-2, E-3, E-4, AND E-5 (PREVIOUSLY STAMPED) | | NEEDED NO RE-STAMP. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2008-02-13 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2008-02-13 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2008-02-13 |
Time |
16:08 |
Sent To |
|
|
Notes |
2008-02-13 16:44:40 | *****APPROVED***** | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | BEEN ADDRESSED;PLAN SHEETS 1.2, 5.1, 6.1, E-2, E-3, | | E-4, AND E-5 WERE STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
F |
Date |
2007-10-31 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-10-31 |
Time |
17:54 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-10-31 |
Time |
16:22 |
Sent To |
|
|
Notes |
2007-10-31 17:54:47 | *****UNSAT***** | | | | PLEASE ACKNOWLEDGE THE FOLLOWING COMMENTS TAKEN FROM | | PREVIOUS FIRE PLAN REVIEW: | | | | | | 01.)FLORIDA FIRE PREVENTION CODE, 2004 EDITION SHALL | | BE REFERENCED. ADD TO CODE SUMMARY NOTES, SHEET 1.1 | | | | 03.)AN ADDRESS IS REQUIRED ON THE BUILDING OF NO LESS | | THAN 6" IN HEIGHT AND 1" IN WIDTH.ON SHEET 1.2, THE | | MINIMUM WIDTH (STROKE) OF THE NUMBER IS INCORRECTLY | | DETAILED | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2007-04-03 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-04-03 |
Time |
16:46 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-04-03 |
Time |
16:06 |
Sent To |
|
|
Notes |
2007-04-03 16:38:51 | *****DENIED***** | | | | PLEASE ACKNOWLEDGE THE FOLLOWING COMMENTS TAKEN FROM | | 10/24/2006 FIRE PLAN REVIEW: | | | | | | 01.)NFPA 101, 2003 EDITION AND FLORIDA FIRE | | PREVENTION CODE, 2004 EDITION SHALL BE REFERENCED. ADD | | TO CODE SUMMARY NOTES, SHEET 1/5 | | | | 02.)STRUCTURES UNDERGOING CONSTRUTION, ALTERATION, | | AND DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | ADD TO SHEET 1 | | | | 03.)AN ADDRESS IS REQUIRED ON THE BUILDING OF NO LESS | | THAN 6" IN HEIGHT AND 1" IN WIDTH.PLEASE INDICATE | | LOCATION OF THE ADDRESS ON THE APPROPIATE ELEVATION | | FRONTING BROADWAY AVENUE.PLEASE DISPLAY ON THE | | APPROPIATE EXTERIOR ELEVETION | | | | | | 08.)PANIC HARDWARE IS REQUIRED ON EXIT DOORS SERVING | | AN OCCUPANT LOAD GREATER THAN ONE HUNDRED.PLEASE | | ACKNOWLEDGE | | | | 09.)PLEASE INDICATE THE MINIMUM INTERIOR FINISH | | CLASSIFICATIONFOR WALLS AND CEILING IN TERMS OF CLASS | | A, B, OR C IN ACCORDANCE WITH NFPA 101, 10.2.PLEASE | | ACKNOWLEDGE | | | | 10.)CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL | | NOT INTERFERE OR HINDER EMERGENCY ACCESS TO THE SAID | | PROPERTY OR VICINITY THEREOF (INCLUDING FIRE LANES). | | ADD TO SHEET 1 | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | LETTER INDICATING HOW/WHERE EACH ITEM EAS ADDRESSED. | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-10-24 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-10-24 |
Time |
10:11 |
Sent To |
|
|
Notes |
2006-10-24 11:03:23 | *****DENIED***** | | | | | | | | | | 01.)NFPA 101, 2003 EDITION AND FLORIDA FIRE | | PREVENTION CODE, 2004 EDITION SHALL BE REFERENCED. | | | | 02.)STRUCTURES UNDERGOING CONSTRUTION, ALTERATION, | | AND DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | 03.)AN ADDRESS IS REQUIRED ON THE BUILDING OF NO LESS | | THAN 6" IN HEIGHT AND 1" IN WIDTH.PLEASE INDICATE | | LOCATION OF THE ADDRESS ON THE APPROPIATE ELEVATION | | FRONTING BROADWAY AVENUE. | | | | 04.)WHAT IS THE OCCUPANCY CLASSIFICATION (I.E. | | ASEMBLY, BUSINESS, EDUCATIONAL) FOR THIS BUILDING? | | | | 05.)IS THE BUILDING PROTECTED BY FIRE PROTECTION | | SYSTEMS SUCH AS A FIRE SPRINKLER AND/OR FIRE ALARM | | SYSTEM? | | | | 06.)IN REFERENCE TO #5, IF THE SCOPE OF THE INTERIOR | | BUILDOUT REQUIRES MODIFICATION OF THE FIRE FIRE | | PROTECTION SYSTEM, SEPARATE PERMIT AND PLANS ARE TO BE | | SUBMITTED FOR REVIEW. | | | | 07.)IN ADDITION TO THE FIRE EXTINGUISHERS SHOWN ON | | THE LIFE SAFETY SHEETS, PLEASE INDICATE THE LOCATION OF | | EXIT LIGHTS, EMERGENCY LIGHTS, AND COMMON PATH TRAVEL | | DISTANCES TO THE EXITS. | | | | 08.)PANIC HARDWARE IS REQUIRED ON EXIT DOORS SERVING | | AN OCCUPANT LOAD GREATER THAN ONE HUNDRED. | | | | 09.)PLEASE INDICATE THE MINIMUM INTERIOR FINISH | | CLASSIFICATIONFOR WALLS AND CEILING IN TERMS OF CLASS | | A, B, OR C IN ACCORDANCE WITH NFPA 101, 10.2. | | | | 10.)CONSTRUTION AND/OR DEMOLITION OPERATIONS SHALL | | NOT INTERFERE OR HINDER EMERGENCY ACCESS TO THE SAID | | PROPERTY OR VICINITY THEREOF (INCLUDING FIRE LANES). | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-10-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-10-15 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-10-15 |
Time |
11:55 |
Sent To |
|
|
Notes |
2008-10-16 16:18:50 | TO "COMM" BD#49 | 2008-10-15 11:55:33 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-07-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-07-11 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-07-11 |
Time |
09:46 |
Sent To |
|
|
Notes |
2008-07-11 09:46:59 | TO "COMM" BD#29 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-01-10 |
|
|
Cont ID |
|
Sent By |
mmiller |
Date |
2008-01-10 |
Time |
17:06 |
Rev Time |
0.00 |
Received By |
mmiller |
Date |
2008-01-10 |
Time |
17:06 |
Sent To |
|
|
Notes |
2008-01-10 17:06:33 | SENT TO COMMERICAL BOARD # 62 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-09-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-20 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-20 |
Time |
08:09 |
Sent To |
|
|
Notes |
2007-10-12 16:16:54 | TO "COMM" BD#54 | 2007-09-20 08:10:05 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-03-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-06 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-06 |
Time |
11:56 |
Sent To |
|
|
Notes |
2007-03-08 11:55:44 | TO "COMM" BD#27 | 2007-03-06 11:56:47 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-10-24 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-10-24 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-09-09 |
Time |
19:22 |
Sent To |
|
|
Notes |
2006-09-15 00:00:00 | TO "COMM" BD#26 | 2006-09-09 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2008-11-02 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-11-02 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-11-02 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
F |
Date |
2008-07-30 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-07-30 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-07-30 |
Time |
09:02 |
Sent To |
|
|
Notes |
2008-07-30 13:16:48 | REVIEW #: 5TH | | ACTION: DENIED | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | 1. OK | | | | 2. PAGE M.1 OUTDOOR AIR CALCULATIONS TABLE STATES THAT | | THESE CALCULATIONS ARE BASED ON ?TABLE 2 OF ASHRAE | | 62-04.? THERE IS NO SUCH TABLE TO BE FOUND IN ASHRAE | | 62.1-2004 EDITION. OUTSIDE AIR CALCULATIONS ARE TO BE | | BASED ON FBCM TABLE 403.3 OR ASHRAE 62.1-04 IN | | ACCORDANCE WITH FBCM 403.4. IF ASHRAE 62.1-04 IS TO BE | | USED FOR VENTILATION, THE VENTILATION RATE PROCEDURE | | SHALL BE DETERMINED IN ACCORDANCE WITH SECTIONS 6.2 | | THROUGH 6.2.9. THE CALCULATIONS FOR THE REQUIRED | | VENTILATION RATES SHALL BE DETERMINED BASED ON THE | | VALUES LISTED IN TABLE 6-1, INCLUDING ANTICIPATED | | OCCUPANT LOADS. OCCUPANT LOADS SHALL NOT BE BASED ON | | ARCHITECTURAL PLANS. THEY SHALL BE BASED ON THE | | OCCUPANCY CATEGORY AND OCCUPANT DENSITY SHOWN ON TABLE | | 6-1. | | | | THE RATES SHOWN ON THE TABLE ON PAGE M.1 DO NOT | | CORRESPOND WITH TABLE 6-1 OF ASHRAE 62.1-04. EXAMPLE: | | AHU #1 SERVES 1 ? CONFERENCE ROOMS AND A MEETING HALL. | | SEE ?CONFERENCE/MEETING? UNDER THE GENERAL CATEGORY ON | | TABLE 6-1. | | | | NOTE: THE COOLING LOADS OF THE PROPOSED A/C SYSTEMS IS | | INCREASING SIGNIFICANTLY BASED ON REDESIGNED OUTSIDE | | AIR BEING FED THROUGH THESE SYSTEMS. PLEASE PROVIDE | | COOLING LOAD CALCULATIONS FOR EACH SYSTEM IN ACCORDANCE | | WITH FBCB 13-407.1.ABC.1. | | | | 3. OK | | | | 4. OK | | | | 5. OK | | | | 6. | | A) AN ENGINEERING SHEET FOR THE ROOFTOP CONDENSER | | STANDS HAS BEEN PROVIDED. HOWEVER, THERE IS NO | | INFORMATION ON THIS SHEET REGARDING ATTACHMENT OF THE | | STAND TO THE STRUCTURE. PAGE M.1 SHOWS A ROOF STAND | | WITH THE STATEMENT ?PRE-ENGINEERED EQUIPMENT RACK.? IF | | THIS IS PRE ENGINEERED, THEN A PRODUCT APPROVAL MUST BE | | PROVIDED AND THIS PRODUCT APPROVAL SHALL BE APPROVED IN | | WRITING BY THE DESIGNER OF RECORD IN ACCORDANCE WITH | | FBCB 106.3.3. FOR MORE INFORMATION ON THE FLORIDA | | PRODUCT APPROVAL SYSTEM PLEASE VISIT | | WWW.FLORIDABUILDING.ORG. | | B) OK | | | | 7. RTU FLOAT SWITCH IS OK. HOWEVER, MEANS AND LOCATION | | OF CONDENSATE DISPOSAL IS STILL NOT SHOWN ON PLANS AS | | PREVIOUSLY REQUESTED IN ACCORDANCE WITH FBCM 307.2. | | | | 8. OK EXCEPT, SEE COMMENT #2 ABOVE FOR COOLING LOAD | | CALCULATIONS WHICH SHALL BE APPENDED TO THE ENERGY | | CALCULATIONS IN ACCORDANCE WITH FBCB 13-407.1.ABC.1. | | | | 9. OK | | | | NOTE:F.S. 553.80(2)(B) WITH RESPECT TO EVALUATION OF | | DESIGN PROFESSIONALS' DOCUMENTS, IF A LOCAL GOVERNMENT | | FINDS IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH | | THE FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW. | | | | THIS SERVES ONLY AS A WARNING AT THIS TIME. SHOULD ANY | | SUBSEQUENT REVIEW FAIL FOR ANY OF THE PREVIOUSLY STATED | | CODE SECTION, A FINE OF FOUR TIMES THE PLAN REVIEW FEE | | SHALL BE IMPOSED. ONE SET OF PLANS IS BEING RETAINED AS | | A RECORD OF PREVIOUS CODE VIOLATIONS SHOULD IT BECOME | | NECESSARY TO IMPOSE THE FINE UNDER FS 553.80(2)(B) | | | | PLEASE RESPOND TO EACH COMMENT IN WRITING WITH A | | DESCRIPTION OF HOW EACH COMMENT HAS BEEN ADDRESSED AS | | WELL AS WHERE THE INFORMATION CAN BE FOUND. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2008-02-08 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2008-02-08 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2008-02-07 |
Time |
16:50 |
Sent To |
|
|
Notes |
2008-02-08 15:49:34 | REVIEW #: 4TH | | ACTION: DENIED | | | | FBC 2004 CODE FAMILY W/ 2005 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | NOTE: RESPONSE LETTER FROM GORDON BUCK INDICATES THE | | MECHANICAL PROJECT HAS BEEN COMPLETELY REDESIGNED. | | THEREFORE, A COMPLETE REVIEW OF THE MECHANICAL SYSTEM | | IS NECESSARY AND ADDITIONAL NEW COMMENTS ARE POSSIBLE. | | | | 1. BATHROOMS HAVE BEEN RECONFIGURED FROM WHAT WAS SHOWN | | ON PREVIOUS PLANS. THE WOMEN?S RESTROOM DOES NOT HAVE | | ADEQUATE EXHAUST. THE FLOOR PLAN ON PG M.2 NOW SHOWS | | THE WOMEN?S RESTROOM WITH 4 WATER CLOSETS. FLOOR PLAN | | ALSO SHOWS AN EXHAUST FAN PROVIDING 150 CFM OF EXHAUST. | | A MINIMUM OF 50 CFM PER WATER CLOSET IS REQUIRED IN | | ACCORDANCE WITH FBC, M TABLE 403.3. AS SUCH THE WOMEN?S | | RESTROOM REQUIRES A MINIMUM OF 200 CFM OF EXHAUST. | | ALSO, BOTH THE MEN?S AND WOMEN?S RESTROOMS SHOW SUPPLY | | AIR IN EXCESS OF THE EXHAUST AIR. ALL AIR SUPPLIED TO | | THE RESTROOMS SHALL BE EXHAUSTED IN ACCORDANCE WITH | | FBC, M 403.2.1. | | | | 2. OUTSIDE AIR CALCULATIONS ARE NOT IN CONFORMANCE WITH | | THE REQUIREMENTS OF TABLE 403.3. THE FOLLOWING ARE | | EXAMPLES ONLY. THE CALCULATIONS FOR THE ENTIRE BUILDING | | SHOULD BE CHECKED FOR ACCURACY PRIOR TO RESUBMITTAL. | | -AHU #1: THIS UNIT SERVES TWO CONFERENCE ROOMS AND A | | MEETING HALL. FBC, M TABLE 403.3 PUTS THE OCCUPANT LOAD | | IN THESE AREAS AT 50 PEOPLE PER 1000 SQUARE FEET. WITH | | ONE OF THE CONFERENCE ROOMS DIVIDED IN HALF (BECAUSE IT | | IS SERVED BY AHU 1 AND AHU 3, THE TOTAL SQUARE FEET OF | | THESE THREE AREAS IS 402 SF. AT 50/1000 THESE AREAS | | HAVE AN OCCUPANT LOAD OF 20 PEOPLE WITH AN OUTSIDE AIR | | RATE OF 20 CFM PER PERSON FOR A TOTAL REQUIRED OUTSIDE | | AIR VOLUME OF 400 CFM. | | -AHU #2 AND AHU #4: THE OCCUPANT LOAD OF THE ASSEMBLY | | AREAS ARE TO BE CALCULATED AT 150 PEOPLE PER 1000 | | SQUARE FEET. WHERE SPACES HAVING DIFFERENT VENTILATION | | RATE REQUIREMENTS ARE SERVED BY A COMMON VENTILATION | | SYSTEM, THE RATIO OF OUTDOOR AIR TO TOTAL SUPPLY AIR | | FOR THE SYSTEM SHALL BE DETERMINED BASED ON THE SPACE | | HAVING THE LARGEST OUTDOOR AIR REQUIREMENT IN | | ACCORDANCE WITH FBC, M 403.3.2. THEREFORE, THE ENTIRE | | SPACE SERVED BY AHU #2 AND AHU #4 SHALL BE CALCULATED | | AT THE RATE STATED ABOVE. ACCORDING TO THE TABLE ON PG | | M.1, THESE UNITS SERVE A COMBINED SPACE OF 4665 SQUARE | | FEET FOR A TOTAL OCCUPANT LOAD OF 700 PEOPLE. AT A RATE | | OF 15 CFM PER PERSON THE TOTAL REQUIRED VOLUME OF | | 10,500 CFM. AHU #2 AND AHU #4 ARE NOT CAPABLE OF | | SUPPLYING THESE QUANTITIES EVEN AT 100% OUTSIDE AIR. | | NOTE: THERE ARE DIFFERENT DESIGN PARAMETERS AND SYSTEM | | CONFIGURATIONS WHICH COULD SIGNIFICANTLY REDUCE THE | | AMOUNT OF OUTSIDE AIR REQUIRED FOR THESE SPACES. THESE | | NUMBERS ARE BASED SOLELY ON THE INFORMATION AND SYSTEMS | | SHOWN ON THE PLANS. PLEASE CALL IF THE DESIGNERS WOULD | | LIKE TO DISCUSS ALTERNATIVES OR OPTIONS. | | | | 3. AHU #2, AHU #4 AND PU #6 AT 5 TONS ARE CAPABLE OF | | PRODUCING CFM IN EXCESS OF 2,000 AND THEREFORE A FAN | | SHUT-DOWN BY SMOKE DETECTOR IS STILL REQUIRED ON THESE | | SYSTEMS IN ACCORDANCE WITH FBC, M 606.2.1. | | | | 4. OK. FLOOR PLAN NOW SHOWS DUCTED RETURNS, THUS | | ELIMINATING PLENUM CLOSETS. | | | | 5. PG M.3: PRIVATE BATH IS STILL MISSING EXHAUST AS | | REQUIRED IN ACCORDANCE WITH FBC, M TABLE 403.3. | | | | 6. A) CONDENSING UNITS SHOWN ON ROOF INSTALLED ON | | EXISTING A/C STANDS. AS STATED IN PREVIOUS REVIEW, WORK | | DONE WITHOUT A PERMIT WILL NOT BE CONSIDERED EXISTING. | | THEREFORE, PRE-ENGINEERED A/C STANDS ARE REQUIRED TO | | HAVE PRODUCT APPROVAL IN ACCORDANCE WITH FAC RULE | | 9B-72. PROVIDE PRODUCT APPROVAL DOCUMENTATION, REVIEWED | | AND APPROVED IN WRITING BY THE PROJECT DESIGN | | PROFESSIONAL IN ACCORDANCE WITH FBC 106.3.3. ALSO, PU | | #6 IS INSTALLED ON A ROOF CURB. PROVIDE DETAIL WITH | | WIND LOAD CALCULATIONS FOR BUILDING PLAN REVIEW TO SHOW | | HOW CURB IS TO BE ATTACHED TO STRUCTURE AND HOW UNIT IS | | TO BE ATTACHED TO CURB. MECHANICAL EQUIPMENT, | | APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO WIND SHALL | | BE DESIGNED AND INSTALLED TO RESIST THE WIND PRESSURES | | ON THE EQUIPMENT AND THE SUPPORTS AS DETERMINED IN | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING PER | | FBC, M 301.13. | | NOTE: THIS REQUIREMENT INCLUDES THE ROOFTOP PACKAGE | | UNIT ITSELF, WHICH MUST ALSO BE DESIGNED AND TESTED TO | | WITHSTAND WIND PRESSURES AS REQUIRED BY THIS SECTION. | | B) CU #4, CU #5 AND PU #6 ARE LOCATED ON SECOND STORY | | ROOF. HOW IS THIS EQUIPMENT TO BE ACCESSED FOR SERVICE? | | WHERE EQUIPMENT AND APPLIANCES REQUIRING ACCESS ARE | | INSTALLED ON ROOFS OR ELEVATED STRUCTURES AT A HEIGHT | | EXCEEDING 16 FEET, SUCH ACCESS SHALL BE PROVIDED BY A | | PERMANENT APPROVED MEANS OF ACCESS, THE EXTENT OF WHICH | | SHALL BE FROM GRADE OR FLOOR LEVEL TO THE EQUIPMENT AND | | APPLIANCES? LEVEL SERVICE SPACE IN ACCORDANCE WITH FBC, | | M 306.5. PLEASE SEE THIS CODE SECTION FOR ADDITIONAL | | SPECIFIC REQUIREMENTS. PROVIDE DETAIL ON PLANS SHOWING | | COMPLIANCE WITH THIS SECTION. | | | | 7. THIS COMMENT WAS NOT ADDRESSED. ALSO, ROOFTOP | | PACKAGE UNIT REQUIRES AUXILIARY DRAIN PROTECTION IN | | ACCORDANCE WITH FBC, M 307.2.3. A FLOAT SWITCH INSIDE | | THE UNIT ON THE PRIMARY DRAIN PAN WILL MEET THIS | | REQUIREMENT. | | | | 8. COMPLETION OF PROCEDURES DEMONSTRATING COMPLIANCE | | WITH THIS CODE FOR COMMERCIAL BUILDINGS SHALL BE SIGNED | | AND SEALED BY AN ARCHITECT OR ENGINEER LICENSED TO | | PRACTICE IN THE STATE OF FLORIDA IN ACCORDANCE WITH FBC | | 13-103.1.1.1. | | | | NEW COMMENT: GENERAL NOTE #2 ON PG M.1 STATES THAT | | OUTSIDE AIR IS PROVIDED BY OARTU 1 & 2. THIS NOTE IS | | NOT APPLICABLE TO THIS JOB AT THIS TIME AND SHOULD BE | | REMOVED FROM PLANS. FBC 106.1.1. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2007-11-06 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-11-06 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-11-05 |
Time |
16:29 |
Sent To |
|
|
Notes |
2007-11-06 13:33:12 | REVIEW #: 3RD | | ACTION: DENIED | | | | FBC 2004 CODE FAMILY W/ 2005 SUPPLEMENTS | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | *PLEASE NOTE* A FINE OF FOUR TIMES THE PERMIT FEE WAS | | ISSUED FOR MECHANICAL, ELECTRICAL AND PLUMBING FOR WORK | | DONE WITHOUT A PERMIT. PLEASE PROVIDE DETAILED | | INFORMATION REGARDING WORK DONE WITHOUT PERMITS AS WELL | | AS ALL WORK TO BE DONE UNDER THIS PERMIT. THERE HAS | | BEEN A CHANGE OF OCCUPANCY UNDERTAKEN WITHOUT PERMITS. | | THEREFORE THE NOTES ON THE PLANS REGARDING THE EXISTING | | CHURCH ARE NOT ACCURATE. THERE IS NO ASSEMBLY OCCUPANCY | | AT THIS LOCATION EXISTING OR OTHERWISE PRIOR TO THE | | ISSUANCE OF A CERTIFICATE OF OCCUPANCY BY THE BUILDING | | OFFICIAL. THE ISSUANCE OF PERMITS AND THE SUCCESSFUL | | COMPLETION OF ALL REQUIRED INSPECTIONS ARE REQUIRED | | BEFORE A CERTIFICATE OF OCCUPANCY CAN BE ISSUED. | | | | NOTE: ALL A/C SYSTEMS IN THIS PROPOSED BUILDING WERE | | INSTALLED WITHOUT A PERMIT. UNTIL THEY HAVE BEEN | | PERMITTED, INSPECTED AND PASSED, THEY ARE NOT TO BE | | CONSIDERED EXISTING. REMOVE NOTATIONS FROM PLANS | | CLAIMING THE MECHANICAL SYSTEMS ARE EXISTING. PLEASE | | PROVIDE THE REQUIRED DETAILS AND DOCUMENTATION FOR | | NEWLY INSTALLED A/C SYSTEMS. INCLUDE EQUIPMENT | | SCHEDULES, DUCT SIZES, CFMS AT ALL DIFFUSERS AND | | REGISTERS. SEE FBC,M 106.3.5.1.4. | | | | NOTE: ALL A/C SYSTEMS WILL BE REVIEWED AS NEW. HOWEVER, | | THE REVIEW WILL BE LIMITED BASED ON THE SMALL AMOUNT OF | | INFORMATION PROVIDED. ADDITIONAL COMMENTS ARE LIKELY | | ONCE ALL REQUIRED INFORMATION IS PROVIDED. | | | | 1. PG M.1: BATHROOM EXHAUST, HVAC NOTE # 6 INDICATES | | THAT BATH EXHAUST FANS ARE 100 CFM. THE WOMEN?S | | BATHROOM HAS 3 WATER CLOSETS AND THE MEN?S BATHROOM HAS | | 2 WATER CLOSETS AND 2 URINALS. THESE SPACES ARE | | REQUIRED TO HAVE EXHAUST RATES OF 50 CFM PER WATER | | CLOSET OR URINAL IN ACCORDANCE WITH FBC,M TABLE 403.3. | | THE WOMEN?S RESTROOM REQUIRES MIN. 150 CFM AND THE | | MEN?S RESTROOM REQUIRES MIN. 200 CFM. SHOW HOW THESE | | FANS ARE TO BE CONTROLLED, THE SIZE AND LOCATION OF | | EXHAUST DUCTS AND THE DISCHARGE LOCATION. SHOW | | COMPLIANCE WITH FBC,M 401.3, 401.5, 401.6, 403.2.1(3). | | | | 2. PG M.1: OUTDOOR AIR CALCULATIONS SCHEDULE SHOWN ON | | PLANS DOES NOT ACTUALLY CONTAIN ANY CALCULATIONS. IT IS | | MERELY A LISTING OF THE REQUIREMENTS OF FBC,M TABLE | | 403.3. IT PROVIDES NO INFORMATION REGARDING THE AMOUNT | | OF OUTSIDE AIR REQUIRED FOR EACH LOCATION OR THE AMOUNT | | OF OUTSIDE AIR BEING PROVIDED FOR EACH AREA. SHOW THE | | CALCULATIONS BASED ON THE ACTUAL OCCUPANT LOAD OF THESE | | SPACES AND THE AMOUNT OF OUTSIDE AIR PROVIDED. ALSO, | | PROVIDE AN AIR BALANCE SCHEDULE SHOWING WHETHER OR NOT | | THE BUILDING IS PRESSURIZED WITH RESPECT TO THE | | OUTDOORS IN ACCORDANCE WITH FBC 13-409.1.ABC.2. | | | | 3. PG M.1: AHU?S IN CLOSET #2 ARE BOTH SHOWN SHARING A | | RETURN PLENUM CLOSET. WHERE MULTIPLE AIR-HANDLING | | SYSTEMS SHARE COMMON RETURN AIR PLENUMS WITH A COMBINED | | DESIGN CAPACITY GREATER THAN 2,000 CFM, THE RETURN AIR | | AND SUPPLY AIR SYSTEM SHALL BE PROVIDED WITH SMOKE | | DETECTORS IN ACCORDANCE WITH FBC,M 606.2.1. SEE FBC,M | | 606.2.2. | | ANY OF THE OTHER SMOKE DETECTORS SHALL BE INSTALLED IN | | ANY OF THE OTHER SUPPLY AIR SYSTEMS IN THE BUILDING | | WITH A DESIGN CAPACITY GREATER THAN 2,000 CFM IN THE | | SUPPLY AIR DUCT. FBC,M 606.2.1. | | 4. WHAT TYPE OF DOORS ARE TO BE USED ON THE A/C CLOSETS | | WHICH ARE BEING USED AS PLENUMS? MATERIALS EXPOSED | | WITHIN PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A | | FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A | | SMOKE-DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED | | IN ACCORDANCE WITH ASTM E 84. FBC,M 602.2.1. SHOW A | | DOOR SCHEDULE OR PROVIDE SOME INDICATION ON PLANS THAT | | DOORS USED AS PART OF PLENUM ENCLOSURES ARE IN | | COMPLIANCE WITH THIS SECTION. | | | | 5. PG M.2: FLOOR PLAN SHOWS TWO SEPARATE TOILET ROOMS. | | PROVIDE VENTILATION IN THESE AREAS IN ACCORDANCE WITH | | FBC,M TABLE 403.3. SEE COMMENT #1 FOR ADDITIONAL | | REQUIREMENTS. | | | | 6. LOCATIONS AND METHODS OF INSTALLATION FOR OUTDOOR | | MECHANICAL EQUIPMENT ARE NOT SHOWN ON PLANS. SHOW THE | | LOCATION OF ALL OUTDOOR EQUIPMENT ALONG WITH MEANS OF | | INSTALLATION WHICH IS IN COMPLIANCE WITH FBC,M 301.13 | | AND FBC SEC.1609. | | | | 7. SHOW MEANS AND LOCATION OF CONDENSATE DISPOSAL IN | | COMPLIANCE WITH FBC,M 307.2, INCLUDING MEANS OF | | AUXILIARY OR SECONDARY DRAIN PROTECTION IN ACCORDANCE | | WITH FBC,M 307.2.3. NOTE: ALL CONDENSATE DRAIN | | MATERIALS USED IN THE PLENUM CLOSETS SHALL BE | | NON-COMBUSTIBLE IN COMPLIANCE WITH FBC,M 602.2.1. | | | | 8. CHANGE OF OCUPANCY: BUILDINGS HAVING A CHANGE OF | | OCCUPANCY THAT WERE PERMITTED AFTER MARCH 15, 1979, | | SHALL COMPLY WITH THE REQUIREMENTS OF SUBCHAPTER 13-4 | | FOR COMMERCIAL APPLICATIONS. WHERE THE EFFICIENCY OF A | | BUILDING COMPONENT IS UNKNOWN, IT SHALL BE DETERMINED | | IN ACCORDANCE WITH THE CRITERIA SPECIFIED IN SECTION | | 101.4.2.1. SEE FBC 13-101.3. PROVIDE AN ENERGY CODE | | COMPLIANCE FORM IN ACCORDANCE WITH FBC 13-400.0.ABC. | | SEE ALSO FBC 13-400.3.ABC.1. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | RONALD J. REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-03-27 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-03-27 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-03-27 |
Time |
10:39 |
Sent To |
|
|
Notes |
2007-03-27 10:46:54 | PLEASE SEE PREVIOUS MECHANICAL REVIEW COMMENTS. NO | | INFORMATION HAS BEEN PROVIDED REGARDING THE SCOPE OF | | MECHANICAL WORK. NO ENERGY CALCULATIONS HAVE BEEN | | PROVIDED. | | | | *PLEASE NOTE* A FINE OF FOUR TIMES THE PERMIT FEE WAS | | ISSUED FOR MECHANICAL, ELECTRICAL AND PLUMBING FOR WORK | | DONE WITHOUT A PERMIT. PLEASE PROVIDE DETAILED | | INFORMATION REGARDING WORK DONE WITHOUT PERMITS AS WELL | | AS ALL WORK TO BE DONE UNDER THIS PERMIT. THERE HAS | | BEEN A CHANGE OF OCCUPANCY UNDERTAKEN WITHOUT PERMITS. | | THEREFORE THE NOTES ON THE PLANS REGARDING THE EXISTING | | CHURCH ARE NOT ACCURATE. THERE IS NO ASSEMBLY OCCUPANCY | | AT THIS LOCATION EXISTING OR OTHERWISE PRIOR TO THE | | ISSUANCE OF A CERETIFICATE OF OCCUPANCY BY THE BUILDING | | OFFICIAL. THE ISSUANCE OF PERMITS AND THE SUCCESSFUL | | COMPLETION OF ALL REQUIRED INSPECTIONS ARE REQUIRED | | BEFORE A CERTIFICATE OF OCCUPANCY CAN BE ISSUED. | | | | RONALD J REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-10-17 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-10-17 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-10-17 |
Time |
14:33 |
Sent To |
|
|
Notes |
2006-10-17 16:06:27 | DENIED: | | NO MECHANICAL WORK OR CONTRACTOR INDICATED HOWEVER, 4X | | FEE WAS ISSUED FOR MEP'S STARTING WORK WITHOUT PERMIT, | | THIS INDICATES MECHANICAL WORK HAS ALREADY BEEN DONE. | | PLEASE PROVIDE ENERGY CALCULATIONS PER 2004 FBC CHAPTER | | 13 SUB-CHAPTER 4. | | | | PLEASE PROVIDE PLANS WITH MECHANICAL PERMIT | | APPLICATION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT PATTY KRAUSS | | AT (561) 805-6719 OR E-MAIL [email protected]. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2008-07-29 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-07-29 |
Time |
06:21 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-07-29 |
Time |
06:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2008-02-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2008-02-05 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2008-02-05 |
Time |
15:28 |
Sent To |
|
|
Notes |
2008-02-05 15:35:06 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 BUILDING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | FBC-2004 EXISTING BLDG CODE | | | | ****FROM PREVIOUS REVIEW: | | COMMENT NUMBERS TO STAY THE SAME. | | | | ******FROM PREVIOUS REVIEWS: 3RD REVIEW*** | | | | ********FROM PREVIOUS REVIEWS: 4TH REVIEW*** | | | | 1. OK | | 2. OK | | 3. OK | | | | 4. SUBMIT CALCULATIONS FOR MINIMUM PLUMBING FACILITIES | | PER TABLES 1004.2 AND 403.1. | | ****NOT ADDRESSED. IT SEEMS THAT THERE IS MORE THAN A-3 | | OCCUPANCY. PLEASE SEE SECTION 403.1.1 POTTY PARITY FOR | | THE A-3 OCCUPANCY. INDICATE ALL OCUPANCIES AND INDICATE | | THE SQUARE FOOTAGE OF ALL OCCUPANCIES AS WELL AS THE | | TOTAL OCCUPANCY LOAD OF EACH OCCUPANCY. ******RESPONSE | | NOTED, BUT THE CALCULATIONS WERE NOT SUBMITTED. IS THE | | TOTAL AREA OF THE BUILDING TO BE A-3 OCCUPANCY | | INCLUDING ALL THE OFFICES ON THE SECOND FLOOR? THE | | TOTAL SQUARE FOOTAGE IS 10411SF @ 7NET THE TOTAL | | OCCUPANCY IS 1488. THIS NUMBER DIVIDED BY 2, (MEN & | | WOMEN), COMES TO 744 EACH. 744 DIVIDED BY 150 EQUALS 5 | | WATER CLOSETS FOR MEN AND 744 DIVIDED BY 75 EQUALS 10 | | WATER CLOSETS FOR WOMEN TO ACHIEVE POTTY PARITY | | REQUIRED BY SECTION 403.1.1. THAT SAID, IF THERE IS | | OTHER OCCUPANCIES BESIDES ASSEMBLY PLEASE INDICATE BY | | SUBMITTING CALCULATIONS FOR MINIMUM PLUMBING | | FACILITIES. | | ********RESPONSE NOTED, BUT THE CALCULATIONS ONLY | | ACCOUNT FOR 3233SF, BUT THE TOTAL AREA IS INDICATED AS | | 10,411SF. INDICATE WHERE THE OTHER 7178SF REQUIRED IN | | THE CALCULATION IS INDICATED. | | | | 5. OK | | 6. OK | | 7. OK | | 8. OK | | 9. OK | | 10. OK | | 11. OK | | 12. OK | | 13. OK | | 14. OK | | | | **********NEW COMMENTS********** | | | | 1B. OK | | 2B. OK | | | | **********NEW COMMENT********** | | | | 1C. IN RELATIONSHIP TO THE CHANGE OF OCCUPANCY, SECTION | | 806.1 OF THE FLORIDA BUILDING CODE EXISTING BUILDING | | INDICATES "ACCESSIBILITY IN PORTIONS OF BUILDINGS | | UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL | | COMPLY WITH CHAPTER 11 OF THE FLORIDA BUILDING CODE, | | BUILDING. IS THE SECOND FLOOR CONSIDERED ASSEMBLY | | OCCUPANCY, AND WHAT WAS THE OCCUPANCY PREVIOUSLY. | | PLEASE CLARIFY. | | ********RESPONSE NOTED, BUT THE TOILET ROOMS ON THE | | SECOND FLOOR SHALL BE ACCESSIBLE PER SECTION 806.1 OF | | THE EXISTING BUILDING CODE | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2007-11-24 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-11-24 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-11-24 |
Time |
17:14 |
Sent To |
|
|
Notes |
2007-11-24 17:23:29 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 BUILDING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | ****FROM PREVIOUS REVIEW: | | COMMENT NUMBERS TO STAY THE SAME. | | | | ******FROM PREVIOUS REVIEWS: 3RD REVIEW*** | | | | 1. OK | | 2. OK | | 3. OK | | | | 4. SUBMIT CALCULATIONS FOR MINIMUM PLUMBING FACILITIES | | PER TABLES 1004.2 AND 403.1. | | ****NOT ADDRESSED. IT SEEMS THAT THERE IS MORE THAN A-3 | | OCCUPANCY. PLEASE SEE SECTION 403.1.1 POTTY PARITY FOR | | THE A-3 OCCUPANCY. INDICATE ALL OCUPANCIES AND INDICATE | | THE SQUARE FOOTAGE OF ALL OCCUPANCIES AS WELL AS THE | | TOTAL OCCUPANCY LOAD OF EACH OCCUPANCY. ******RESPONSE | | NOTED, BUT THE CALCULATIONS WERE NOT SUBMITTED. IS THE | | TOTAL AREA OF THE BUILDING TO BE A-3 OCCUPANCY | | INCLUDING ALL THE OFFICES ON THE SECOND FLOOR? THE | | TOTAL SQUARE FOOTAGE IS 10411SF @ 7NET THE TOTAL | | OCCUPANCY IS 1488. THIS NUMBER DIVIDED BY 2, (MEN & | | WOMEN), COMES TO 744 EACH. 744 DIVIDED BY 150 EQUALS 5 | | WATER CLOSETS FOR MEN AND 744 DIVIDED BY 75 EQUALS 10 | | WATER CLOSETS FOR WOMEN TO ACHIEVE POTTY PARITY | | REQUIRED BY SECTION 403.1.1. THAT SAID, IF THERE IS | | OTHER OCCUPANCIES BESIDES ASSEMBLY PLEASE INDICATE BY | | SUBMITTING CALCULATIONS FOR MINIMUM PLUMBING | | FACILITIES. | | | | 5. OK | | | | 6. POTTY PARITY IS REQUIRED PER SECTION 403.1.1. THIS | | IS NOT INDICATED ON PLANS. | | ****NOT ADDRESSED | | ******RESPONSE NOTED, BUT SECTION 403.1.1 IS NOT | | COMPLIED WITH. THE CODE SECTION STATES "IN ASSEMBLY | | OCCUPANCIES, RESTROOMS WHICH ARE OPEN TO THE PUBLIC | | MUST HAVE A RATIO OF 3:2 WATER CLOSETS PROVIDED FOR | | WOMEN AS THE TOTAL OF WATER CLOSETS AND URINALS | | PROVIDED FOR MEN". POTTY PARITY CALCULATIONS SUBMITTED | | HAVE 4 WATER CLOSETS FOR MEN TO 3 WATER CLOSETS FOR | | WOMEN. | | | | 7. OK | | 8. OK | | | | 9. SHT 3/5 NEW MEN'S TOILET ROOM STALL DOES NOT COMPLY | | WITH FIGURE 30E AS REQUIRED IN SECTION 11-4.17.3 | | EXCEPTION. ALSO A TURNING AREA IS REQUIRED IN THE | | TOILET ROOMS. PLEASE INDICATE ON PLANS. SECTION | | 11-4.22.3. | | ****RESPONSE NOTED, BUT THE TURNING AREA IS NOT SHOWN | | IN THE TOILET ROOMS AS REQUIRED. (NOT REQUIRED IN THE | | ACCESSIBLE STALL). | | ******RESPONSE NOTED, BUT THE STALL STILL DOES NOT | | COMPLY WITH FIGURE 30E. THE LAV IS NOT ALLOWED IN THE | | CLEAR FLOOR SPACE OF THE WATER CLOSET. FIVE FEET OF | | CLEAR FLOOR SPACE FROM THE WALL ADJACENT TO THE WATER | | CLOSET TO THE SIDE OF THE LAV. THE LAV CAN NOT BE IN | | THE CLEAR FLOOR SPACE OF THE WATER CLOSET. | | | | 10. OK | | | | 11. SUBMIT A DETAIL FOR THE URINAL SHOWING COMPLIANCE | | WITH 11-4.18 AND ALL SUBSECTIONS. | | ****RESPONSE NOTED, BUT THE FOLLOWING SECTIONS WERE NOT | | ADDRESSED: | | A. OK | | B. 11-4.18.4 FLUSH CONTROLS | | ******RESPONSE NOTED, BUT THE CONTROL HEIGHT IS | | REQUIRED. | | | | 12. OK | | 13. OK | | 14. OK | | | | **********NEW COMMENTS********** | | | | 1B. OK | | | | 2B. SHT 3/5 MEN'S TOILET ROOM ACCESSIBLE STALL. THE | | ACCESSIBLE W/C SHALL BE LOCATED IN THE CORNER, DIAGONAL | | TO THE DOOR. SECTION 11-4.17.3 EXCEPTION (2). | | ******RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. | | | | **********NEW COMMENT********** | | | | 1C. IN RELATIONSHIP TO THE CHANGE OF OCCUPANCY, SECTION | | 806.1 OF THE FLORIDA BUILDING CODE EXISTING BUILDING | | INDICATES "ACCESSIBILITY IN PORTIONS OF BUILDINGS | | UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL | | COMPLY WITH CHAPTER 11 OF THE FLORIDA BUILDING CODE, | | BUILDING. IS THE SECOND FLOOR CONSIDERED ASSEMBLY | | OCCUPANCY, AND WHAT WAS THE OCCUPANCY PREVIOUSLY. | | PLEASE CLARIFY. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-03-19 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-03-19 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-03-19 |
Time |
17:14 |
Sent To |
|
|
Notes |
2007-03-19 17:42:32 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 BUILDING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | ****FROM PREVIOUS REVIEW: | | COMMENT NUMBERS TO STAY THE SAME. | | | | 1. OK | | 2. OK | | 3. OK | | | | 4. SUBMIT CALCULATIONS FOR MINIMUM PLUMBING FACILITIES | | PER TABLES 1004.2 AND 403.1. | | ****NOT ADDRESSED. IT SEEMS THAT THERE IS MORE THAN A-3 | | OCCUPANCY. PLEASE SEE SECTION 403.1.1 POTTY PARITY FOR | | THE A-3 OCCUPANCY. INDICATE ALL OCUPANCIES AND INDICATE | | THE SQUARE FOOTAGE OF ALL OCCUPANCIES AS WELL AS THE | | TOTAL OCCUPANCY LOAD OF EACH OCCUPANCY. | | | | 5. OK | | | | 6. POTTY PARITY IS REQUIRED PER SECTION 403.1.1. THIS | | IS NOT INDICATED ON PLANS. | | ****NOT ADDRESSED | | | | 7. OK | | 8. OK | | | | 9. SHT 3/5 NEW MEN'S TOILET ROOM STALL DOES NOT COMPLY | | WITH FIGURE 30E AS REQUIRED IN SECTION 11-4.17.3 | | EXCEPTION. ALSO A TURNING AREA IS REQUIRED IN THE | | TOILET ROOMS. PLEASE INDICATE ON PLANS. SECTION | | 11-4.22.3. | | ****RESPONSE NOTED, BUT THE TURNING AREA IS NOT SHOWN | | IN THE TOILET ROOMS AS REQUIRED. (NOT REQUIRED IN THE | | ACCESSIBLE STALL). | | | | 10. SHT 3/5 ELEVATIONS FOR WATER CLOSETS AND LAVS. SHOW | | THE FOLLOWING INFORMATION: | | FOR W/C'S | | A. OK | | B. 11-4.16.3 HEIGHT (SHOWN AS 20") (NOT ADDRESSED) | | (17" TO 19") | | C. OK | | D. 11-4.16.5 FLUSH CONTROLS (NOT ADDRESSED) | | FOR LAV'S | | A. 11-4.19.3 CLEAR FLOOR SPACE (NOT ADDRESSED)B. | | 11-4.19.5 FAUCETS (NOT ADDRESSED) | | | | 11. SUBMIT A DETAIL FOR THE URINAL SHOWING COMPLIANCE | | WITH 11-4.18 AND ALL SUBSECTIONS. | | ****RESPONSE NOTED, BUT THE FOLLOWING SECTIONS WERE NOT | | ADDRESSED: | | A. 11-4.18.3 CLEAR FLOOR SPACE | | B. 11-4.18.4 FLUSH CONTROLS | | | | 12. SUBMIT A DETAIL FOR THE ACCESSIBLE DRINKING | | FOUNTAIN PER 11-4.15 AND ALL SUBSECTIONS, AS WELL AS | | 11-4.1.3(10)(B) PROVISIONS FOR THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING IF THE DRINKING FOUNTAIN | | IS NOT A HIGH/LOW UNIT. | | ****RESPONSE NOTED, BUT A DETAIL FOR THE ACCESSIBLE | | DRINKING FOUNTAIN HAS NOT BEEN SUBMITTED. | | | | 13. SHT 3/5 PLUMBING SANITARY RISER DIAGRAM. URINALS | | ARE NOT VENTED. SECTION 901.2.1. | | ****RESPONSE NOTED, BUT THE RISER DIAGRAM DOES NOT | | REFLECT THE FLOOR PLAN, NOR DOES IT MEET CODE | | REQUIREMENTS.--THE FLOOR PLAN SHOWS TWO URINALS, | | BUT THE RISER DIAGRAM SHOW THREE URINALS.--THE | | DRINKING FOUNTAIN IS NOT SHOWN ON THE RISER DIAGRAM. -- | | THE LAV IN THEACCESSIBLE STALL IS NOT VENTED.-- THE | | URINALS STILL ARE NOT VENTED.SECTION 106.1.1. (SEE | | RED LINE MARKINGS ON THE COPY OF THE RISER DIAGRAM. | | | | 14. SUBMIT A WATER RISER DIAGRAM ISOMETRIC. SHOW ALL | | PIPE SIZES, VALVES, AND WATER HAMMER ARRESTORS AS | | REQUIRED BY SECTION 604.9. IF WATER HAMMER ARRESTORS | | ARE INSTALLED, THEY SHALL BE LOCATED NEAR THE FIXTURE | | IN AN "EFFECTIVE RANGE" NOT IN THE CEILING. PDI-WH 201 | | AND MANUF. INSTALLATION INSTRUCTIONS. | | ****NO RESPONSE. NOT ADDRESSED. | | | | **********NEW COMMENTS********** | | | | 1B. ALL SHEETS. THE ADDRESS FOR THE ENGINEER DOES NOT | | REFLECT THE ADDRESS ON THE FLORIDA DBPR WEBSITE. PLEASE | | UPDATE THE WEBSITE OR CHANGE THE TITLE BLOCK. FAC | | 61G15-23.002(2)&FS 471.025. (SEE ATTACHED DBPR | | WEBSITE SHEET). | | | | 2B. SHT 3/5 MEN'S TOILET ROOM ACCESSIBLE STALL. THE | | ACCESSIBLE W/C SHALL BE LOCATED IN THE CORNER, DIAGONAL | | TO THE DOOR. SECTION 11-4.17.3 EXCEPTION (2). | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-10-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-10-11 |
Time |
07:32 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-10-11 |
Time |
07:32 |
Sent To |
|
|
Notes |
2006-10-11 08:02:08 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 BUILDING | | FBC-2004 CHAPTER 1 | | FBC-2004 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1. AN ARCHITECT OR ENGINEER IS REQUIRED TO DESIGN THE | | PLANS PER FS 481.229 | | | | 2. HOLD DATED 2-9-05 INDICATES THAT COMPLETE PLANS ARE | | REQUIRED. THIS IS A CHANGE OF OCCUPANCY, AND WORK WAS | | DONE WITH PERMITS. PLEASE SUBMIT FLOOR PLANS FOR BOTH | | FLOORS SHOWING FLOOR PLANS PRIOR TO CHANGES MADE WITH | | OUT PERMITS. SECTION 106.1.1. | | | | 3. PER FBC-2004 EXISTING BUILDING CODE, INDICATE LEVEL | | OF ALTERATION. CHAPTER 3. | | | | 4. SUBMIT CALCULATIONS FOR MINIMUM PLUMBING FACILITIES | | PER TABLES 1004.2 AND 403.1. | | | | 5. SEPARATE FACILITIES ARE REQUIRED FOR MEN AND WOMEN. | | NO WOMEN'S TOILET ROOM INDICATED. SECTION 403.2. | | | | 6. POTTY PARITY IS REQUIRED PER SECTION 403.1.1. THIS | | IS NOT INDICATED ON PLANS. | | | | 7. PER TABLE 403.1 AT LEAST ONE DRINKING FOUNTAIN IS | | REQUIRED. | | | | 8. SHT 3/5 HAS A NOTE THAT STATES, "PLUMBING PERMIT ON | | RECORD". SEE ATTACHED SHEET. NO PLUMBING PERMIT IS | | INDICATED ON RECORD. | | | | 9. SHT 3/5 MEW MEN'S TOILET ROOM STALL DOES NOT COMPLY | | WITH FIGURE 30E AS REQUIRED IN SECTION 11-4.17.3 | | EXCEPTION. ALSO A TURNING AREA IS REQUIRED IN THE | | TOILET ROOMS. PLEASE INDICATE ON PLANS. SECTION | | 11-4.22.3. | | | | 10. SHT 3/5 ELEVATIONS FOR WATER CLOSETS AND LAVS. SHOW | | THE FOLLOWING INFORMATION: | | FOR W/C'S | | A. 11-4.16.2 CLEAR FLOOR SPACE | | B. 11-4.16.3 HEIGHT (SHOWN AS 20") | | C. 11-4.16.4 GRAB BARS (SHOW LENGTHS) | | D. 11-4.16.5 FLUSH CONTROLS | | FOR LAV'S | | A. 11-4.19.3 CLEAR FLOOR SPACE | | B. 11-4.19.5 FAUCETS | | | | 11. SUBMIT A DETAIL FOR THE URINAL SHOWING COMPLIANCE | | WITH 11-4.18 AND ALL SUBSECTIONS. | | | | 12. SUBMIT A DETAIL FOR THE ACCESSIBLE DRINKING | | FOUNTAIN PER 11-4.15 AND ALL SUBSECTIONS, AS WELL AS | | 11-4.1.3(10)(B) PROVISIONS FOR THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING IF THE DRINKING FOUNTAIN | | IS NOT A HIGH/LOW UNIT. | | | | 13. SHT 3/5 PLUMBING SANITARY RISER DIAGRAM. URINALS | | ARE NOT VENTED. SECTION 901.2.1. | | | | 14. SUBMIT A WATER RISER DIAGRAM ISOMETRIC. SHOW ALL | | PIPE SIZES, VALVES, AND WATER HAMMER ARRESTORS AS | | REQUIRED BY SECTION 604.9. IF WATER HAMMER ARRESTORS | | ARE INSTALLED, THEY SHALL BE LOCATED NEAR THE FIXTURE | | IN AN "EFFECTIVE RANGE" NOT IN THE CEILING. PDI-WH 201 | | AND MANUF. INSTALLATION INSTRUCTIONS. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
P |
Date |
2008-10-21 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2008-10-21 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2008-10-21 |
Time |
09:30 |
Sent To |
|
|
Notes |
2008-10-21 09:34:44 | PASSED W/PROVISO | | | | PROVISO: THE A/C LOUVERED SCREENS ARE TO BE PAINTED TO | | MATCH THE COLOR OF THE BUILDING. | | | | NOTES: | | | | 1) AN IRRIGATION PERMIT IS REQUIRED. REMEMBER THAT THE | | GRASS STRIP ON THE NORTH SIDE OF THE PROPERTY (IN THE | | RIGHT-OF-WAY) IS REQUIRED TO BE IRRIGATED. | | | | 2) THE SIDEWALK EASEMENT WILL NEED TO BE IN PLACE PRIOR | | TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | | CONTACT ERIC SCHNEIDER @ (5610 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
F |
Date |
2008-07-17 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2008-07-17 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2008-07-17 |
Time |
16:12 |
Sent To |
|
|
Notes |
2008-07-17 16:25:50 | FAILED | | | | 1) REPEAT COMMENT - THE 4'10" HIGH AC EQUIPMENT ON THE | | ROOF SHALL BE SCREENED. PLANS/ELEVATIONS/PICTURES TO | | DEMONSTRATE THIS HAVE NOT BEEN PROVIDED. ELEVATIONS DO | | NOT SHOW AC EQUIPMENT OR PARAPET HEIGHTS. | | | | 2) REPEAT COMMENT - THE TERMINAL LANDSCAPE ISLAND AT | | THE SOUTHWEST CORNER OF THE PROPERTY DOES NOT HAVE 5 | | FEET OF PLANTING AREA.THERE IS ROOM TO SHIFT THE ROW | | TO THE NORTH. | | | | 3) ONE ADDITIONAL PERIMETER TREE IS REQUIRED ALONG THE | | PROPERTY LINE AT THE SOUTH END OF THE REAR PARKING | | (WHERE THE DUMPSTER WAS FORMERLY SHOWN). | | | | 4) ALL LANDSCAPE IS TO BE PROTECTED FROM VEHICULAR | | ENCROACHMENT.THE PLANS DO NOT INDICATE THE CURB TYPE | | ALONG THE WEST PROPERTY BOUNDARIES.A TYPE "D" CURB IS | | REQUIRED.PLEASE REMEMBER THAT THE LANDSCAPE AREAS | | SHALL REMAIN AT LEAST 5 FEET WIDE OF PLANTING AREA. | | | | 5) AN IRRIGATION PERMIT IS REQUIRED.NOTE THAT THE | | GRASS STRIP ON THE NORTH SIDE OF THE PROPERTY (IN THE | | RIGHT-OF-WAY) IS REQUIRED TO BE IRRIGATED. | | | | 6) IT IS RECOMMENDED THAT THE SABAL PALMS BE | | UNDERPLANTED WITH SHRUBS OR GROUND COVER, NOT SOD AS | | SHOWN. | | | | 7) PLEASE NOTE THAT THE SIDEWALK EASEMENT WILL NEED TO | | BE IN PLACE PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF | | OCCUPANCY. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2008-01-23 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2008-01-23 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2008-01-23 |
Time |
09:00 |
Sent To |
|
|
Notes |
2008-01-23 09:48:44 | FAILED | | | | 1) THE SITE AND LANDSCAPE PLANS INCORRECTLY SHOW THE | | PROPERTY LINE INCORRECTLY IN RELATIONSHIP TO THE | | ADJACENT SIDEWALKS AND CURBLINES AS THEY ARE SHOWN ON | | THE SURVEY.THIS HAS CAUSED AN ISSUE WITH THE REQUIRED | | 8 FOOT SIDEWALK THAT IS REQUIRED ALONG BROADWAY AVENUE. | | THE SOUTH PARKING LOT WILL NEED TO BE ADJUSTED. | | | | 2) REPEAT COMMENT - BASED ON THE INFORMATION PROVIDED | | ON THE SURVEY, 3 FEET OF THE REQUIRED SIDEWALK WILL | | NEED TO BE ON THE SITE.THIS 3 FOOT STRIP WILL REQUIRE | | THE OWNER TO SIGN A PUBLIC ACCESS EASEMENT.PLEASE | | CONTACT VINCE NOEL, CITY SURVEYOR, AT 494-1040. | | | | 3) REPEAT COMMENT - THE DUMPSTER ENCLOSURE SHOWN ON THE | | PLANS DOES NOT MEET MINIMUM CITY STANDARDS.IT IS MY | | UNDERSTANDING FROM PREVIOUS MEETINGS THAT THIS IS AN | | EXISTING DUMPSTER AND LOCATION YOU ARE TRYING TO | | "VEST."THE ENGINEERING SERVICES DEPARTMENT, | | SPECIFICALLY, EMERY FABIAN @ 494-1040, SHALL APPROVE | | THE SIZE AND LOCATION PRIOR TO THE APPROVAL OF THIS | | BUILDING PERMIT.IF THE ENGINEERING SERVICES | | DEPARTMENT DOES NOT APPROVE THE DUMPSTER SIZE OR | | LOCATION, THEN THE SITE AND LANDSCAPE PLANS WILL NEED | | TO BE REDESIGNED. | | | | 4) THE AC EQUIPMENT ON THE ROOF SHALL BE SCREENED. | | PLANS/ELEVATIONS/PICTURES TO DEMONSTRATE THIS HAVE NOT | | BEEN PROVIDED. | | | | 5) REPEAT COMMENT - THE LANDSCAPE TERMINAL ISLANDS ARE | | REQUIRED TO HAVE 5 FEET OF PLANTING AREA.THE PLANS | | SHOW CURBING INCLUDED IN THE 5 FEET. | | | | 6) A SHADE OR FLOWERING TREE IS REQUIRED IN THE | | TERMINAL ISLAND ADJACENT TO THE HANDICAP PARKING | | SPACE. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2007-10-22 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2007-10-22 |
Time |
20:06 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2007-10-22 |
Time |
20:06 |
Sent To |
|
|
Notes |
2007-10-22 20:13:49 | FAILED | | | | 1) A SURVEY LESS THAN ONE YEAR OLD IS REQUIRED.THE | | SURVEY SHALL SHOW ALL EASEMENTS. (REPEAT COMMENT) | | | | 2) THE LANDSCAPE BUFFERS ARE REQUIRED TO BE PROVIDED ON | | THE PARCEL.IT APPEARS THAT SOME OF THE BUFFERS ALONG | | THE WEST AND SOUTH PROPERTY LINES MAY NOT BE ON THE | | SITE.THIS WILL BE CONFIRMED ONCE A SURVEY WILL BE | | PROVIDED. | | | | 3) PURSUANT TO SECTION 94-443(C)(3)(A), EACH ROW OF | | PARKING SPACES SHALL BE TERMINATED BY LANDSCAPE ISLANDS | | OF NOT LESS THAN FIVE (5) FEET IN WIDTH AND NOT LESS | | THAN THE LENGTH OF THE ADJACENT PARKING STALL.THE | | LANDSCAPE ISLAND SHALL HAVE A MINIMUM RADIUS OF 2 FEET | | AT ITS END SO AS TO ALLOW CAR MANEUVERING.THE | | LANDSCAPE ISLAND SHALL CONTAIN AT LEAST ONE SHADE OR | | FLOWERING TREE.NOTE THAT THE ISLANDS NEED TO BE ON | | THE PROPERTY LINE.ADDITIONALLY, THE MIDDLE ROW IN THE | | SOUTH PARKING LOT DOES NOT HAVE LANDSCAPE.(REPEAT | | COMMENT) | | | | 4) A PUBLIC ACCESS EASEMENT WILL BE REQUIRED FOR THE | | PORTION OF THE SIDEWALK ON THE SUBJECT PARCEL. | | | | 5) THE DUMPSTER, DUMPSTER ENCLOSURE AND LOCATION OF THE | | DUMPSTER SHALL BE APPROVED BY THE ENGINEERING SERVICES | | DEPARTMENT. (REPEAT COMMENT) | | A. PLEASE PROVIDE A COPY OF A SITE PLAN SIGNED APPROVED | | FROM THE ENGINEERING SERVICES DEPARTMENT. | | | | 6) THE IRRIGATION WILL REQUIRE A PERMIT. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-03-15 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2007-03-13 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2007-03-13 |
Time |
09:48 |
Sent To |
|
|
Notes |
2007-03-13 15:09:36 | FAILED | | | | 1) A SURVEY LESS THAN ONE YEAR OLD IS REQUIRED.THE | | SURVEY SHALL SHOW ALL EASEMENTS. | | | | 2) A LANDSCAPE PLAN, PREPARED BY A LANDSCAPE ARCHITECT, | | IS REQUIRED. | | | | 3) AN ELEVATION OF THE BUILDING ALONG BROADWAY AVENUE | | SHALL BE PROVIDED. | | A. PLEASE STATE WHETHER ANY EXTERIOR IMPROVEMENTS WILL | | BE DONE TO THE BUILDING FA?ADE(S). | | | | 4) PURSUANT TO SECTION 94-219(D)(9)(B), ALL EXISTING | | SURFACE PARKING LOTS SHALL BE LANDSCAPED WITH A 36-INCH | | HIGH PERIMETER HEDGE AND SHADE TRESS AT EVERY THIRD | | PARKING SPACE.SHRUBS SHALL BE PLANTED AT TWO-FOOT | | INTERVALS. | | A. A LANDSCAPE BUFFER SHALL BE PROVIDED ALONG THE WEST | | AND SOUTH SIDES OF THE PARKING LOT TO THE SOUTH OF THE | | SITE. | | | | 5) PURSUANT TO SECTION 94-443(C)(3)(A), EACH ROW OF | | PARKING SPACES SHALL BE TERMINATED BY LANDSCAPE ISLANDS | | OF NOT LESS THAN FIVE (5) FEET IN WIDTH AND NOT LESS | | THAN THE LENGTH OF THE ADJACENT PARKING STALL.THE | | LANDSCAPE ISLAND SHALL HAVE A MINIMUM RADIUS OF 2? FEET | | AT ITS END SO AS TO ALLOW CAR MANEUVERING.THE | | LANDSCAPE ISLAND SHALL CONTAIN AT LEAST ONE SHADE OR | | FLOWERING TREE. | | | | 6) PURSUANT TO SECTION 94-443(C)(5)(A), LANDSCAPE AREAS | | SHALL BE SEPARATED FROM VEHICULAR USE AREAS BY | | NONMOUNTABLE, CONCRETE CURBING OF THE TYPE | | CHARACTERIZED AS ?TYPE D?.A ?TYPE D? CURB SHALL BE | | PROVIDED ALONG ALL VEHICULAR USE AREAS. | | | | 7) PURSUANT TO SECTION 94-221(B)(6), SIDEWALKS ALONG | | BROADWAY AVENUE SHALL BE A MINIMUM OF EIGHT FEET IN | | CLEAR WIDTH. | | | | 8) PROPOSED CBS WALL SHALL BE SIX (6) FEET HIGH FOR ITS | | ENTIRE LENGTH. | | | | 9) IN ORDER TO INCREASE A PEDESTRIAN ORIENTED MIXED USE | | DISTRICT ALONG BROADWAY AVENUE, THE BROADWAY MIXED USE | | DISTRICT REGULATIONS REQUIRES ALL BUILDINGS TO HAVE | | PRINCIPAL PEDESTRIAN ENTRANCES FACING THE BROADWAY | | FRONTAGE LINE.IF THERE IS AN OPPORTUNITY, PLEASE | | PROVIDE A DOORWAY TO BROADWAY AVENUE. | | | | 10) DUMPSTER, DUMPSTER ENCLOSURE AND LOCATION OF THE | | DUMPSTER SHALL BE APPROVED BY THE ENGINEERING SERVICES | | DEPARTMENT. | | A. PLEASE PROVIDE A COPY OF A SITE PLAN SIGNED APPROVED | | FROM THE ENGINEERING SERVICES DEPARTMENT. | | B. PURSUANT TO SECTION 94-221(D)(10), DUMPSTERS SHALL | | BE ENCLOSED IN A STRUCTURE CONSISTENT WITH THE | | ARCHITECTURE OF THE BUILDING.THE MATERIAL OF THE | | PROPOSED DUMPSTER ENCLOSURE (A WOOD FENCE) IS NOT | | CONSISTENT WITH THE ARCHITECTURE OF THE BUILDING. | | C. PURSUANT TO SECTION 94-444(B), DUMPSTER ENCLOSURE | | SHALL BE LANDSCAPED WITH SHRUBS AND HEDGES PLANTED AT | | TWO-FOOT INTERVALS. | | | | 11) THE PLANNING AND ZONING DEPARTMENT RECOGNIZES THAT | | THE EXISTING PARKING LOT IS NOT STRIPED AND THUS THE | | TOTAL NUMBER OF EXISTING PARKING SPACES IS NOT DEFINED. | | THEREFORE; THERE SHALL BE AS MANY PARKING SPACES | | MEETING CODE REQUIREMENT AS CAN BE PROVIDED IN THE | | RECONFIGURATION OF THE EXISTING PARKING LOT. | | | | 12) PARKING SPACES ON THE SOUTH SIDE OF THE SITE ARE | | ALONG THE CURB CUT ON 52ND ST AND THUS PRESENT AN | | UNSAFE SITUATION.THE CURB CUT SHALL BE RECONFIGURED | | WHERE CONFLICTS EXIST OR THE PARKING SPACES SHALL BE | | ELIMINATED. | | | | 13) PURSUANT TO SECTION 94-485(G), CURBS, WHEELSTOPS, | | OR BOLLARDS SHALL BE INSTALLED TO PROTECT LANDSCAPED | | AREAS, PEDESTRIAN AREA, BUILDINGS, AND PROPERTY LINES. | | PROVIDE A CURB AROUND THE BUILDING. | | | | 14) DELINEATE THE WALKWAY OR ACCESS AISLE FROM THE | | HANDICAP PARKING SPACES TO THE MAIN ENTRANCE OF THE | | BUILDING. | | | | 15) HANDICAP PARKING STALL DETAIL MEETING CODE | | REQUIREMENTS SHALL BE PROVIDED. | | A. HANDICAP SYMBOL SHALL BE TWO (2) FEET FROM THE OPEN | | END OF THE PARKING SPACE. | | B. HANDICAP SYMBOL SHALL FACE RIGHT. | | | | 16. WHEEL STOPS SHALL BE SIX (6) INCHES IN HEIGHT. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-10-03 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2006-10-03 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2006-10-03 |
Time |
14:53 |
Sent To |
|
|
Notes |
2006-10-03 00:00:00 | PARKING AND LANDSCAPE REVISIONS REQUIRED | | PER DISCUSSION WITH THE ZONING STAFF. | | | | CONTACT ERIC SCHNEIDER @ 561) 822-1435. | 2006-09-17 00:00:00 | CHANGE IN OCCUPANCY. |
|
|
|