Plan Review Stops For Permit 06090190 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-10-04 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-10-04 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-10-04 |
Time |
13:15 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-09-26 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-09-26 |
Time |
07:18 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-09-26 |
Time |
06:11 |
Sent To |
PC |
|
Notes |
2006-09-26 00:00:00 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 1ST | | ACTION: DENIED | | | | 1) THE CLAIMED VALUAATION ON THE PERMIT | | APPLICATION IS LOW. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | COST EXCLUDING LAND VALUE. OUR VALUATION | | REFERENCE IS ICC (BVD) MARSHALL-SWIFT | | AND MEANS COST ANALYSIS SERVICES PER | | 108.3 FBC* | | | | 2) ADDITIONAL PERMITS WILL BE REQUIRED | | FOR THE PAVERS DECK/BABY FENCE ALARMS | | ETC. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | TEL:(561)805-6726 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-10-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-10-03 |
Time |
13:45 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-10-03 |
Time |
12:52 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-09-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-09-18 |
Time |
13:03 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-09-18 |
Time |
12:53 |
Sent To |
P |
|
Notes |
2006-09-18 00:00:00 | | | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | THE POOL SPECIFICATIONS CALL FOR A GAS | | HEATER. THE ELECTRICAL SCHEMATIC | | INDICATES AN ELECTRICAL HEAT PUMP. | | PLEASE CORRELATE THE PLAN WITH ACTUAL | | PROPOSED WORK. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2006-10-04 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-10-04 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-10-04 |
Time |
10:46 |
Sent To |
B |
|
Notes |
2006-10-04 00:00:00 | NOTE: PRIVIOUS COMMENTS ADRESSED, | | 400,000 BTU GAS HEATER |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2006-09-21 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-09-21 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-09-21 |
Time |
10:02 |
Sent To |
B |
|
Notes |
2006-09-21 00:00:00 | REFERENCE PLUMBING COMMENTS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-09-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-28 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-28 |
Time |
15:20 |
Sent To |
E |
|
Notes |
2006-09-28 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-09-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-14 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-14 |
Time |
13:53 |
Sent To |
E |
|
Notes |
2006-09-14 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-09-26 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-09 |
Time |
14:17 |
Sent To |
|
|
Notes |
2006-09-09 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-10-04 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-10-04 |
Time |
10:45 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-10-04 |
Time |
10:44 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-09-21 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-09-21 |
Time |
09:52 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-09-21 |
Time |
09:52 |
Sent To |
G |
|
Notes |
2006-09-21 00:00:00 | ******DENIED****** | | REFERENCE: FBC-2004 SEC. 424.2 SWIMMING | | POOLS | | | | THE FOLLOWING INFORMATION IS REQUIRED | | FOR PLUMBING PLAN REVIEW: | | | | 1. PLEASE CORRELATE THE PRINTS FOR | | RESUBMITTAL. THE POOL SPECIFICATIONS | | INDICATE A GAS POOL HEATER AND THE | | ELECTRICAL SCHEMATIC INDICATES AN | | ELECTRIC POOL HEATER. | | 2. FBC-2004 SEC. 424.2.14.1, OR | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | WATER HEATERS SHALL BEAR THE LABEL OF A | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | SHEETS REQUIRED, PLEASE SUBMIT) | | 3. FBC-2004 SEC. 424.2.14.2, OR | | FBCR-2004 SEC. R4101.14.2 WATER | | RETENTION, PROVIDE A POSITIVE MEANS OF | | RETAINING WATER IN THE HEATER WHEN PUMP | | IS SHUT OFF.(MANUFACTURE SHEETS | | REQUIRED, PLEASE SUBMIT) | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN | | RESUBMITTING, PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED PROVIDE ONE COPY OF | | ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2006-09-12 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-09-12 |
Time |
17:20 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-09-12 |
Time |
17:20 |
Sent To |
I |
|
Notes |
|
|