Plan Review Stops For Permit 06090171 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
N |
Date |
2006-12-19 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2006-09-21 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2006-09-21 |
Time |
15:14 |
Sent To |
|
|
Notes |
2006-09-21 00:00:00 | EXT # 0001 CREATED FOR THIS UNIT:420 | | COLUMBIA DR # 110 | 2006-09-18 00:00:00 | NEEDS EXT, NO SUITE IN SYSTEM |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-02-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-02-28 |
Time |
17:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-02-28 |
Time |
17:17 |
Sent To |
|
|
Notes |
2007-02-28 17:18:31 | STAMP PLANS AND PRINT PERMIT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-02-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-02-05 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-02-05 |
Time |
10:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-12-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2006-12-19 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2006-12-19 |
Time |
09:53 |
Sent To |
|
|
Notes |
2006-12-19 10:40:19 | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) ON SHEET A1.0 EXIT CORRIDOR 105THAT LEADS TO THE | | EXISTING EXIT DOOR IS SPECIFIED AS FILE ROOM. FBC | | 1013.2 PROHIBITS EGRESS THROUGH STORAGE ROOMS OR SPACES | | USED FOR SIMILAR PURPOSES. PLEASE CORRECT AND INDICATE | | THAT 105 IS A CORRIDOR AND THE FILES ARE LOCATED IN THE | | CLOSET. | | | | 3) THE EXIT LIGHT LAYOUT ON A2.0 DOES NOT INDICATE THAT | | THE EXIT AT CORRIDOR 105 IS A REQUIRED EXIT ( DUE TO | | REQUIRED EXIT SEPARATION) . PLEASE CORRECT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-10-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2006-10-05 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2006-10-05 |
Time |
14:42 |
Sent To |
|
|
Notes |
2006-10-05 00:00:00 | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) SPECIFY THE LEVEL OF ALTERATION AS | | SPECIFIED IN CHAPTER 3 OF THE 2004 FBC | | EXISTING BUILDING CODE. | | | | 3) SPECIFY THE TYPE OF CONSTRUCTION FOR | | THE BUILDING. SEE 2004 FBC 602 AND | | TABLES 601 AND 602. | | | | 4) THERE ARE TWO DETAIL ELEVENS ON SHEET | | A5.0. PLEASE CORRECT. | | | | 5) SPECIFY THE INSULATION AND REQUIRED | | FIRE RESISTANCE RATING FOR THE NEW | | EXTERIOR MASONRY WALL SHOWN IN DETAIL | | 11/A5.0 | | | | 6) 2004 FBC 1014.2.1 TWO EXITS OR EXIT | | ACCESS DOORWAYS. | | WHERE TWO EXITS OR EXIT ACCESS DOORWAYS | | ARE REQUIRED FROM ANY PORTION OF THE | | EXIT ACCESS, THE EXIT DOORS OR EXIT | | ACCESS DOORWAYS SHALL BE PLACED A | | DISTANCE APART EQUAL TO NOT LESS THAN | | ONE-HALF OF THE LENGTH OF THE MAXIMUM | | OVERALL DIAGONAL DIMENSION OF THE | | BUILDING OR AREA TO BE SERVED MEASURED | | IN A STRAIGHT LINE BETWEEN EXIT DOORS OR | | EXIT ACCESS DOORWAYS. INTERLOCKING OR | | SCISSOR STAIRS SHALL BE COUNTED AS ONE | | EXIT STAIRWAY. | | EXCEPTIONS: | | 1.WHERE EXIT ENCLOSURES ARE | | PROVIDED AS A PORTION OF THE REQUIRED | | EXIT AND ARE INTERCONNECTED BY A 1-HOUR | | FIRE-RESISTANCE-RATED CORRIDOR | | CONFORMING TO THE REQUIREMENTS OF | | SECTION 1016 , THE REQUIRED EXIT | | SEPARATION SHALL BE MEASURED ALONG THE | | SHORTEST DIRECT LINE OF TRAVEL WITHIN | | THE CORRIDOR. | | 2.WHERE A BUILDING IS EQUIPPED | | THROUGHOUT WITH AN AUTOMATIC SPRINKLER | | SYSTEM IN ACCORDANCE WITH SECTION | | 903.3.1.1 OR 903.3.1.2 , THE SEPARATION | | DISTANCE OF THE EXIT DOORS OR EXIT | | ACCESS DOORWAYS SHALL NOT BE LESS THAN | | ONE-THIRD OF THE LENGTH OF THE MAXIMUM | | OVERALL DIAGONAL DIMENSION OF THE AREA | | SERVED. | | THE EXITS TO THIS SPACE DO NOT COMPLY. | | PLEASE REVISE. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2007-05-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-05-18 |
Time |
17:03 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-05-18 |
Time |
17:03 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2007-05-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-05-07 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-05-07 |
Time |
14:51 |
Sent To |
|
|
Notes |
2007-05-07 14:58:41 | ** UNSAT ** | | | | ** PLEASE SEE THE PREVIOUS *PROVISO* NOTES WHICH WERE | | REDLINED ON PLAN 2/4/07 WHICH REQUESTED CORRECTIONS TO | | BE MADE BEFORE ROUGH ELECTRICAL INSPECTION. | | PLEASE SEE ITEMS BELOW WHICH WERE ON PLANS TO BE | | ADDRESSED. | | | | 1) NOTE: PLEASE INDICATE ALL OVER RIDE TIMES AND ANY | | TIMES FOR OCCUPANCY TYPE DEVICES ON PLANS. | | PLEASE LIST ANY TIMED SCHEDULING. | | PLEASE SEE 13-415.1.ABC.1.1, 1.2 AND .1.3. | | | | 2) NOTE: PLEASE NOTE AND INDICATE ALL BRANCH CIRCUITING | | FOR EMERGENCY AND EXIT LIGHTS AHEAD OF ANY LOCAL | | SWITCHING INCLUDING NEW LIGHTING CONTROLS SUCH AS | | OCCUPANCY DEVICES, TIMER OVER RIDES ETC. | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-02-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-02-04 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-02-03 |
Time |
19:23 |
Sent To |
|
|
Notes |
2007-02-04 09:49:48 | *** PROVSIO/ REDLINED NOTES *** | | | | ** IMPORATANT** | | | | THE FOLLOWING MUST BE REVISED, SUBMITTED, REVIEWED AND | | STAMPED FOR JOB-SITE INSPECTION BEFORE ANY ROUGH | | ELECTRICAL INSPECTION IS CALLED IN. | | | | 1) NOTE: PLEASE SEE NO TIMES ARE STATED ON PLANS FOR | | OVER RIDE CONTROLS AS PREVIOUSLY REQUESTED. PLEASE SEE | | THE RESPONSE LETTER MENTIONS THIS WILL BE SET PER THE | | OWNERS? REQUEST: HOWEVER THE MAXIMUM TIMES ARE | | DETERMINED BY THE FLORIDA BUILDING CODE | | 13-415.1.ABC.1.1 AND .1.2. THIS IS NOT AN OPTION OF THE | | OWNER. | | PLEASE SEE MAXIMUM TIMES FOR ALL OCCUPANCY TYPE DEVICES | | ARE 30 MINUTES MAX. | | | | | | 2) NOTE: ALL EM/EXT LTS WIRED PER 700.12E. AHEAD OF ANY | | SWITCH OR OC DEVICE. | | | | ** RISER WAS REVISED TO SHOW CORRECTIONS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW AND | | STAMPING BEFORE ANY ELECTRICLA INSPECTION. IF THERE ARE | | ANY QUESTIONS, PLEASE DO NOT HESIATE ON CONTACTING THIS | | OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | 2007-02-03 19:23:42 | | | IN ELEC FOR REIVEW |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-12-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-12-03 |
Time |
20:42 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-12-03 |
Time |
20:17 |
Sent To |
|
|
Notes |
2006-12-03 20:42:20 | *** UNSAT 2ND REVIEW**** | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW AND NEW | | NOTES DUE TO THE PLANS SUBMITTED. | | THE NOTES BELOW ARE TAKEN DIRECTLY FROM PREVIOUS REVIEW | | AND INDICATE A "NO OR OK". IF A "NO" IS SHOWN, FURTHER | | EXPLANATION/NOTES MAY BE PRESENT. | | ** PLEASE SEE ANY NEW NOTES ARE BEING ADDED TO THE | | BOTTOM OF FIRST REVIEW NOTES. | | | | 1) NOTE: OK | | | | 2) NOTE: OK. | | | | 3) NOTE: NO, LIGHTING CONTROLS ONLY SEEM TO BE SHOWN | | FOR SOME LOCATIONS. PLEASE SEE 13-415.1.ABC.1.2, WHICH | | REQUIRES CONTROL IN ALL AREAS WITH FLOOR TO CEILING | | HEIGHT PARTITIONS. | | PLEASE SEE RESPONSE LETTER MENTIONS LIGHTING DENSITIES | | SHOWN ON E5.1, HOWEVER RISER AND LOAD SUMMARY WERE THE | | ONLY ITEMS LOCATED ON 5.1. | | PLEASE SUBMIT AND SHOW IN DETAIL THE PROPOSED LIGHTING | | CONTROL SYSTEM. PLEASE INDICATE THE NORMAL TIME | | SCHEDULE(S), THE TIMES ON THE TYPES OF OVER RIDE | | DEVICES ETC. | | PLEASE SEE PREVIOUS REVIEW COMMENTS. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE FBC CHAPTER 13, 13-415.1.ABC.1.1, .1.2, AND | | .1.3. | | PLEASE SEE SOME NOTES ARE MENTIONED FOR SOME SORT OF | | LIGHTING CONTROL, HOWEVER ONLY IT SEEMS FOR COMMON | | AREAS? | | PLEASE SEE .1.3, FOR ALL SEPARATE AREAS, WITH FLR TO | | CEILING HEIGHT PARTITIONS. | | PLEASE SUBMIT AND SHOW THE ENTIRE SYSTEM BEING | | INSTALLED AND PROPOSED. PLEASE INCLUDE ALL LOCATIONS | | FOR OVER-RIDE DEVICES AS REQUIRED INCLUDING INGRESS/ | | EGRESS INTO SPACE, SO THE OCCUPANT MAY VISUALLY SEE | | LIGHTING BEING CONTROLLED. | | PLEASE SUBMIT THE SCHEDULING TO TIME OF OPERATION. | | PLEASE INDICATE THE MAXIMUM OF THE TIMES ALLOWED FOR | | EACH TYPE OF OVER-RIDE DEVICE WHICH MAY BE CHOSEN. | | (TIMER TYPE, 4HRS MAX, SENSOR TYPE 30 MINS MAX) | | PLEASE BE SURE TO UPDATE THE SYMBOL LEGEND FOR DEVICES | | CHOSEN. | | PLEASE PROVIDE LIGHTING POWER DENSITIES, PER | | 13-415.1.AB.1, 415.2.C.1, 415.2.B.1 ETC. | | | | 4) NOTE: OK. | | | | 5) NOTE: OK. | | | | | | *** NEW NOTES 2ND REVIEW*** | | | | 1) NOTE: PLEASE SEE PANEL "LA" HAS NOW BEEN CHANGED TO | | A 225A MLO, WITH 300A OVER CURRENT PROTECTION FEEDING | | THIS PANEL?? | | PLEASE SEE PREVIOUS PLANS INDICATED THIS PANEL AS A 400 | | MLO. | | PLEASE SEE RISER SHOWS "LA" FEEDING "LC", WHICH IS OK, | | HOWEVER SEE "LB" INDICATES THIS PANEL AS THE PANEL | | CONTAINING THE "FEED-THRU" LUGS? | | PLEASE SEE RISER AND CORRELATE ALL OF THE ABOVE. | | ADJUST PANEL SIZES AND/OR OVER CURRENT PROTECTION AS | | NEEDED. | | THIS IS A NEW COMMENT AS PLANS WERE CHANGED. | | 240.4, 310.16, 408 ETC. | | | | 2) NOTE: PLEASE SEE ATTACHED SHEET WITH RESPECT TO | | REPEAT COMMENTS FOR CODE COMPLIANCE. | | FLORIDA STATUTES 553.80(2)(B). THIS IS ONLY GIVEN AS A | | NOTICE AT THIS TIME. | | | | | | ** ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-09-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-09-18 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-09-17 |
Time |
17:53 |
Sent To |
|
|
Notes |
2006-09-18 00:00:00 | *** UNSAT *** | | | | 1) NOTE: PLEASE PROIVDE THE YEARS FOR | | THE CODE BEING REFERENCED WHICH ARE | | CURRENTLY IN EFFECT AND RELEVANT TO | | DESIGN. | | NFPA-70 (NEC) 2002, NFPA-72 2002, | | NFPA-101 2003 AND THE 2004 FBC ON | | ELECTRICAL PLANS. | | FBC 106.1.2 ADMIN SECT. | | | | 2) NOTE: PLEASE VERIFY THE LOCATIONS OF | | THE EM LTS AND NIGHT LTS. | | PLEASE SEE THE SYMBOL BEING USED FOR THE | | NL'S APPEAR TO BE ON SOME FIXTURES WHICH | | ARE NOT THE EM LTS/W/ BATTERY BACK UP. | | IF THE EM LTS ARE NOT ON THE NL CIRCUIT, | | WIRED AHEAD OF ANY SWITCHABLE MEANS, | | THIS WOULD CAUSE EACH OF THESE TO BE RUN | | DOWN EACH NIGHT. PLEASE SEE THAT IT | | APPEARS IT MAY BE A MISPRINT FOR THE | | LOCATION OF THESE ON PLANS.?? | | 700.12E. | | | | 3) NOTE: PLEASE SEE FBC CHAPTER 13, 13-415.1.ABC.1.1, | | .1.2, AND .1.3. | | PLEASE SEE SOME NOTES ARE MENTIONED FOR | | SOME SORT OF LIGHTING CONTROL, HOWEVER | | ONLY IT SEEMS FOR COMMON AREAS? | | PLEASE SEE .1.3, FOR ALL SEPARATE AREAS, | | WITH FLR TO CEILING HEIGHT PARTITIONS. | | PLEASE SUBMIT AND SHOW THE ENTIRE SYSTEM | | BEING INSTALLED AND PROPOSED. PLEASE | | INCLUDE ALL LOCATIONS FOR OVER-RIDE | | DEVICES AS REQUIRED INCLUDING INGRESS/ | | EGRESS INTO SPACE, SO THE OCCUPANT MAY | | VISUALLY SEE LIGHTING BEING CONTROLLED. | | PLEASE SUBMIT THE SCHEDULING TO TIME OF OPERATION. | | PLEASE INDICATE TH MAXIMUM OF THE TIMES | | ALLOWED FOR EACH TYPE OF OVER-RIDE | | DEVICE WHICH MAY BE CHOOSEN. (TIMER | | TYPE, 4HRS MAX, SENSOR TYPE 30 MINS MAX) | | PLEASE BE SURE TO UPDATE THE SYMBOL | | LEGEND FOR DEVICES CHOSEN. | | PLEASE PROVIDE LIGHTING POWER DENSITIES, | | PER 13-415.1.AB.1, 415.2.C.1, 415.2.B.1 | | ETC. | | | | 4) NOTE: PLEASE INDICATE ALL CONTINUOUS | | LOADS AT 125%. | | 215.3,230.42 | | | | 5) NOTE: PLEASE SEE PANEL SCHEDULE | | MENTIONS THE FACP IS GOING TO HAVEA | | RECEPT AT THIS LOCATION.PLEASE VERIFY | | THE RECEPT AND WHERE IT WILL BE LCOATED. | | PLEASE SEE ELECTRICAL PLANS INDICATE THE | | CIRCUIT LOCATION, HOWEVER THE FACP IS | | NOT SHOWN. PLEASE SEE THE FOLLOWING TEXT | | FROM NFPA-72 | | 4.4.1.4.2.1THE DEDICATED BRANCH | | CIRCUIT(S) AND CONNECTIONS SHALL BE | | MECHANICALLY PROTECTED. | | 4.4.1.4.2.2CIRCUIT DISCONNECTING MEANS | | SHALL HAVE A RED MARKING, SHALL BE | | ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL, | | AND SHALL BE IDENTIFIED AS "FIRE ALARM | | CIRCUIT." | | 4.4.1.4.2.3THE LOCATION OF THE CIRCUIT DISCONNECTING | | MEANS SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM | | CONTROL | | UNIT. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | | | | 2006-09-17 00:00:00 | IN ELEC FOR REVIEW. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2007-06-14 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2007-06-14 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2007-06-14 |
Time |
13:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2007-02-26 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-02-26 |
Time |
17:13 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-02-26 |
Time |
17:13 |
Sent To |
|
|
Notes |
2007-02-26 17:24:00 | *****APPROVED****** | | | | | | ALL OTHER PREVIOUS FIRE PLAN REVIEW COMMENTS HAVE BEEN | | SATISFIED.SHEET A3.0 STAMPED, INITIALED, AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2006-12-21 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-12-21 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-12-21 |
Time |
17:34 |
Sent To |
|
|
Notes |
2006-12-21 17:54:11 | *****UNSAT****** | | | | | | | | 1.CORRECT VERBAGE ON SHEET A3.0 AND SHEET A3.1 TO: | | INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE | | CLASS "A" OR CLASS "B" IN EXITS AND IN EXIT ACCESS | | CORRIDORS.ALL OTHER AREAS SHALL BE CLASS A, CLASS B, | | OR CLASS C. | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | SHEET INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-10-25 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-10-25 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-10-25 |
Time |
09:19 |
Sent To |
|
|
Notes |
2006-10-25 09:54:47 | *****DENIED***** | | | | | | | | | | 1.)CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL | | NOT INTERFERE OF HINDER EMERGENCY ACCESS TO THE SAID | | PROPERTY OR THE VICINITY THEREOF ( INCLUDING FIRE LANES | | ). | | | | 2.)WHERE THE BUILDING IS PROTECTED BY FIRE PROTECTION | | SYSTEM,SUCH SYSTEM SHALL BE MAINTAINED OPERATIONAL AT | | ALL TIMES DURING ALTERATION. | | | | 3.)THE FIRE DEPARTMENT WILL BE NOTIFIED WHEN A FIRE | | PROTECTION SYSTEM IS SHUT DOWN AND WHEN IT IS RETURNED | | TO SERVICE. | | | | 4.)ALL REQUIRED EXIT COMPONENTS SHALL BE MAINTAINED. | | | | 5.)IF THE SCOPE OF THE INTERIOR BUILDOUT REQUIRES | | MODIFICATION OF THE FIRE SPRINKLER OR FIRE ALARM SYSTEM | | , SEPARATE PERMIT AND PLANS ARE TO BE SUBMITTED FOR | | REVIEW. | | | | 6.)IF THIS BUILDING IS INDEED"UNSPRINKLERED" AS | | LISTED ON SHEET A3.1,THE INTERIOR FINISH | | CLASSIFICATION SHALL BE CLASS"A" OR CLASS "B". | | | | | | | | | | CAPT MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-06-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-07 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-07 |
Time |
11:55 |
Sent To |
M |
|
Notes |
2007-06-07 11:55:39 | TO "M" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-05-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-18 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-18 |
Time |
15:27 |
Sent To |
E |
|
Notes |
2007-05-18 15:27:36 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-04-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-24 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-24 |
Time |
16:05 |
Sent To |
|
|
Notes |
2007-05-04 08:58:20 | TO "COMM" BD#28 | 2007-04-24 16:06:12 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-01-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-20 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-20 |
Time |
15:44 |
Sent To |
|
|
Notes |
2007-02-02 09:09:11 | TO "COMM" BD#5 | 2007-01-20 15:44:59 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-11-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-20 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-20 |
Time |
10:42 |
Sent To |
|
|
Notes |
2006-11-29 14:56:57 | TO COMM BOARD SPACE #45 | 2006-11-20 10:43:15 | WAITING FOR "COMM"BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-10-25 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-10-25 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-09-09 |
Time |
16:02 |
Sent To |
|
|
Notes |
2006-09-15 00:00:00 | TO "COMM" BD#4 | 2006-09-09 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2007-06-22 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-06-22 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-06-22 |
Time |
14:56 |
Sent To |
|
|
Notes |
2007-06-22 15:42:45 | MECH REV P M2.1 AND T & B REPORT. | | | | ISSUE ON PROVISO FROM PREVIOUS REVIEW CORRECTED ON THS | | REVISION. NO LETTER FROM ENGINEER REQUIRED |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2007-06-08 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-06-08 |
Time |
13:00 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-06-08 |
Time |
09:15 |
Sent To |
|
|
Notes |
2007-06-08 13:00:31 | ***********PROVISO************ | | | | PLEASE PROVIDE 2 SIGNED/SEALED LETTERS FROM THE | | ENGINEER OF RECORD STATING THAT THE EXTRA GRILL/CFM | | DESIGNATION ON PLAN IN ROOM 132 WAS LEFT ON PLAN IN | | ERROR AND THE CFMS SHOWN WERE NOT USED IN THE AIR | | BALANCE CALCULATIONS. | | | | RONALD J REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2007-05-15 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2007-05-15 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2007-05-14 |
Time |
12:59 |
Sent To |
|
|
Notes |
2007-05-15 09:12:36 | --------------DENIED---------------- | | | | FBC 2004 CODE FAMILY W/2005 REVISIONS | | FBC 2004 CH.1 AS AMENDED BY THE CITY OF WEST PALM | | BEACH | | | | 1. WHAT IS THE SIZE OF THE FLEX DUCT FEEDING SUPPLY | | DISTRIBUTION BOX IN ROOM 104? | | | | 2. WHAT IS THE CFM OF THE 6" SUPPLY FLEX IN CORR. 105? | | | | 3. ROOM 113 SHOWS 8" FLEX SUPPLY AND RETURN WITH 320 | | AND 290 CFM RESPECTIVELY. THESE ARE OUTSIDE THE RANGES | | OF THE FLEX SCHEDULES FOR 8" ON PG M6.1. PLEASE | | CLARIFY. | | | | 4. ROOMS 107,109,115 ALSO SHOW FLEX DUCTS WITH CFM'S | | OUTSIDE OF THE RANGES ON THE M6.1 SCHEDULE. | | | | 5. RTU-3: 14" FLEX ATTACHED TO R/A RISER IS CARRYING | | 1230 CFM. SCHEDULE STATES A MAX. 700 CFM FOR 14" R/A | | FLEX. WHICH IS CORRECT? PLEASE CLARIFY. | | | | 6. RTU-4: WHAT IS THE SIZE OF THE SUPPLY FLEX FEEDING | | DISTRIBUTION BOX FOR ROOMS 149,153,155? | | | | 7. RTU-4: EQUIPMENT SCHEDULE CALLS FOR 2600 CFM. FLOOR | | PLAN SHOWS 2320 CFM. WHICH ONE IS CORRECT? ALSO, THERE | | ARE ONLY 755 CFM TOTAL RETURN AIR FOR THIS SYSTEM, | | LEAVING SOME AREAS WITHOUT BALANCED RETURN AS REQUIRED | | BY FBC,M 601.4. | | | | 8. ROOM 118 SHOWS 8" SUPPLY FLEX AT 260 CFM, OUTSIDE | | THE RANGE AS SHOWN ON FLEX SCHEDULE. PLEASE CLARIFY. | | | | 9. ROOM 152 SHOWS 6" R/A FLEX AT 120 CFM, OUTSIDE THE | | RANGE AS SHOWN ON FLEX SCHEDULE. PLEASE CLARIFY. | | | | 10. CORR. 140 SHOWS "AA" GRILL FOR 290 CFM WITH NO DUCT | | OR GRILL SHOWN IN CEILING. IS THIS TO BE THROUGH THE | | DOOR INTO ROOM 141? IF SO, HOW WILL 290 CFM BE DRAWN | | THROUGH THE DOOR? THERE IS ONLY 115 CFM OF EXHAUST IN | | THIS SPACE. PLEASE CLARIFY. | | | | 11. ROOM 132 SHOWS "AA" GRILL FOR 240 CFM. NO GRILL IS | | SHOWN IN CEILING AND NO DUCT IS SHOWN. PLEASE CLARIFY. | | | | 12. RTU-5: SCHEDULE SHOWS 1780 CFM SUPPLY. FLOOR PLAN | | SHOWS 2400 CFM SUPPLY WITH 2380 CFM RETURN. WHICH IS | | CORRECT? ALSO, HOW WILL 200 CFM OUTDOOR AIR BE | | INTRODUCED IF THE UNIT RETURNS ALL BUT 20 CFM OF INDOOR | | AIR? | | | | 13. THE AMOUNT OF SUPPLY AIR (INCLUDING OUTDOOR AIR) | | SHALL BE APPROXIMATELY EQUAL TO THE AMOUNT OF RETURN | | AND EXHAUST AIR PER FBC,M 403.1. | | BASED ON TOTAL CFM AS SHOWN ON FLOOR PLAN: | | | | SUPPLY: 11,040 CFM | | RETURN: 8,755 CFM | | EXHAUST: 325 CFM | | | | RETURN PLUS EXHAUST IS 9,080 CFM WHICH IS 1960 CFM LESS | | THAN THE SUPPLY. RETURN PLUS EXHAUST SHOULD APPROX. | | EQUAL 11,040 CFM, WITH THE EXHAUST BEING APPROX. EQUAL | | TO THE 1170 CFM OF OUTDOOR AIR SHOWN ON SCHEDULE TO | | ACHIEVE THE VENTILATION RATES REQUIRED BY FBC,M 403.3. | | NOTE: THE ABOVE R/A TOTAL DOES NOT INCLUDE THE RETURNS | | QUESTIONED IN COMMENTS 10 AND 11, BUT THIS IS NOT | | ENOUGH TO PUT THE SYSTEM IN BALANCE. | | | | IF YOU HAVE ANY QUESTIONS REGARDING THIS REVIEW, PLEASE | | CONTACT: | | | | RONALD J REGUEIRO | | 561.805.6719 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-12-04 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2006-12-04 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2006-12-04 |
Time |
17:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-10-14 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2006-10-14 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2006-10-14 |
Time |
10:42 |
Sent To |
|
|
Notes |
2006-10-14 10:48:53 | ---------------------DENIED----------------------- | | | | 1. PLEASE SHOW MEANS OF CONDENSATE DISPOSAL IN | | COMPLIANCE WITH FBC,M 307.2.1 AND FBC 1503.6. AUXILIARY | | DRAIN PROTECTION IS ALSO REQUIRED PER FBC,M 307.2.3. | | | | 2. ALL R/A GRILL CONNECTIONS ARE SHOWN ON PLAN TO BE | | RIGID RECTANGULAR DUCT EXCEPT ROOM 129. NO SIZES ARE | | GIVEN AS THERE IS ONLY A DUCT SIZE SCHEDULE FOR | | FLEXIBLE DUCT. IF THE INTENT IS TO USE FLEX, PLEASE | | INDICATE SO ON PLAN. IF THE INTENT IS TO USE | | RECTANGULAR RIGID DUCT, PLEASE PROVIDE SIZES FOR EACH | | R/A DROP. NOTE: IN THIS CASE, A RECTANGULAR VOLUME | | DAMPER WILL BE REQUIRED AT EACH DROP. | | | | 3. PAGE M7.1 ROOF CURB DETAIL NOTE #9 STATES THAT A | | STRUCTURAL ENGINEER WILL PROVIDE THE NUMBER AND SIZE OF | | ANCHORS TO BE USED FOR CURB ATTACHMENT. NO SUCH | | INFORMATION WAS PROVIDED. | | | | REVIEWED BY: | | RONALD J REGUEIRO | | 561.805.6734 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2007-06-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-06-09 |
Time |
07:19 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-06-09 |
Time |
07:19 |
Sent To |
|
|
Notes |
2007-06-09 07:24:36 | REVISION DENIED | | REFERENCE: FBC-2004 CHAPTER 1 | | | | 1. NO CHANGES FOUND. THE SAME NUMBERED TRIANGLE AND | | SAME CLOUDED AREAS ARE INDICATED ON THE REVISIED SHEETS | | AS ARE INDICATED ON THE STAMPED ISSUED PLANS FOR | | PERMIT. PLEASE CLOUD ALL REVISIONS AND INDICATE | | REVISIONS WITH A NEW NUMBERED TRANGLE. SECTION | | 106.1.1. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-02-17 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2007-02-17 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2007-02-17 |
Time |
14:17 |
Sent To |
|
|
Notes |
2007-02-17 14:52:59 | RE-SUB |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-01-10 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-01-10 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-01-10 |
Time |
09:08 |
Sent To |
|
|
Notes |
2007-01-10 09:10:15 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 BUILDING | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | FROM FIRST REVIEW: | | | | 1. OK | | | | 2. SHTS PO.1 & P2.1. ENGINEERS SIGNATURE | | IS REQUIRED ON THE SEAL. INITIALS ARE | | NOT ACCEPTABLE. FAC 61G15-23.002(1) AND | | FS 471.025. | | ****RESPONSE NOTED, BUT INITIALS ARE STILL SHOWN ON SHT | | P2.1. PLEASE COMPLY WITH FAC REQUIREMENT. | | | | 3. OK | | 4. OK | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 8O5-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-10-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-10-04 |
Time |
18:04 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-10-04 |
Time |
18:04 |
Sent To |
|
|
Notes |
2006-10-04 00:00:00 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FBC-2004 BUILDING | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1. SHT A3.1 ROOMS 136, & 138. INTERIOR | | FINISH SCHEDULE INDICATES THE WALLS TO | | BE EPOXY PAINT. SECTION 1210.2 STATES | | WALLS WITHIN 2' OF URINALS AND WATER | | CLOSETS SHALL HAVE A SMOOTH, HARD, | | NONABSORBENT SURFACE, TO A HEIGHT OF 4 | | FEET ABOVE THE FLOOR. PLEASE INDICATE | | HOW "PAINT" MEETS THE REQUIREMENT FOR A | | HARD SURFACE. | | | | 2. SHTS PO.1 & P2.1. ENGINEERS SIGNATURE | | IS REQUIRED ON THE SEAL. INITIALS ARE | | NOT ACCEPTABLE. FAC 61G15-23.002(1) AND | | FS 471.025. | | | | 3. SHT P5.1 DOMESTIC WATER ISOMETRIC. | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | NOT IN THE CEILING AS SHOWN. PDI-WH 201 | | AND MANUF. INSTALLLATION INSTRUCTIONS. | | | | 4. SHT P5.1 DOMESTIC WATER ISOMETRIC. | | MOP SINK HOT WATER IS PIPED TO THE RIGHT | | SIDE OF THE FIXTURE, NOT TO THE LEFT | | SIDE AS REQUIRED IN SECTION 607.4. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 8O5-6731 | | E-MAIL [email protected] |
|
|