Plan Review Details - Permit 06090041
Plan Review Stops For Permit 06090041
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-10-18 Cont ID  
Sent By alange Date 2006-10-18 Time 09:28 Rev Time 0.00
Received By alange Date 2006-10-18 Time 09:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-09-14 Cont ID  
Sent By btrobaug Date 2006-09-14 Time 14:53 Rev Time 0.50
Received By btrobaug Date 2006-09-14 Time 14:13 Sent To M
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2006-10-24 Cont ID  
Sent By mperson Date 2006-10-24 Time 08:20 Rev Time 0.45
Received By mperson Date 2006-10-24 Time 08:20 Sent To PC
Notes
2006-10-24 08:27:12PROVISO
 GENERATOR SHALL BE INSTALLED PER MANUFACTURER
 SPECIFICATIONS AND INSTALLATION INSTRUCTIONS
 REGAUARDING CLEARENCES FOR THE GENERATOR IN RELATION TO
 PERMANENT STRUCTURES. INSTALLATION INSTRUCTIONS AND
 MANUFACTURER SPECIFICATIONS SHALL BE ON SITE FOR
 INSPECTIONS.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2006-09-20 Cont ID  
Sent By mperson Date 2006-09-20 Time 13:38 Rev Time 0.33
Received By mperson Date 2006-09-20 Time 13:38 Sent To B
Notes
2006-09-20 00:00:00******DENIED******
 REFERENCE: FBC-2004 FUEL GAS
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR GAS PLAN REVIEW:
  
 ******IMPORTANT INFORMATION******
 AS OF 8/25/06 GENERATOR (GEN/RES AND
 GEN/COM) PERMIT APPLICATIONS SHALL NOT
 BE ACCEPTED UNLESS THE ELECTRICAL INFOR-
 MATION AND GAS (OR DIESEL) INFORMATION
 IS ALL SUBMITTED AT THE SAME TIME. THE
 GENERATOR, ELECTRICAL AND GAS/DIESEL IN-
 FORMATION WILL BE ROUTED TOGETHER. THIS
 WILL ENSURE THAT ALL OF THE INFORMATION
 (PARTICULARLY THE MANUFACTURER'S SPECI-
 FICATIONS AND INSTALLATION INSTRUCTIONS)
 ARE AVAILABLE TO ALL PLAN REVIEWERS.
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 2. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 3. TYPE OF GAS, (LP OR NATURAL)
 4. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2004 FUEL GAS CODE SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU
 402.4(33). (NOTE: THIS INCLUDES THE
 EXISTING BTU'S AS WELL AS THE PROPOSED
 GENERATOR BTU'S)
 5. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4). (NOTE: THIS
 INCLUDES THE EXISTING GAS SYSTEM AS WELL
 AS THE PROPOSED DUE TO THE FACT THAT GAS
 SYSTEMS ARE SIZED BY THE LONGEST LENGTH
 METHOD.)
 6. SUBMIT CALCULATIONS FOR COMBUSTION
 AIR (IF APPLICABLE) PER FBC-2004 FUEL
 GAS CODE SECTION 304.
 7. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 8. SUBMIT A DETAIL SHOWING THE TYPE,
 LOCATION, SIZE AND TERMINATION OF THE
 GAS VENTS PER FBC-2004 FUEL GAS CODE
 SECS. 502 THRU 505. (IF APPLICABLE)
 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2
 (NOTE: THIS INCLUDES THE MANUFACTURER
 INSTALLATION INSTRUCTIONS TO VERIFY
 CLEARENCES.)
 10. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS, BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
 11. CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK AND
 APPURTENANCES PER NFPA 58. IF THE TANK
 IS BELOW GROUND THE CONTAINER SHALL BE
 SECURILY ANCHORED PER NFPA 58 SECTION
 3-2.2.7(H).
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  
  
  
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2006-09-01 Cont ID  
Sent By swurafti Date 2006-09-01 Time 15:13 Rev Time 0.00
Received By swurafti Date 2006-09-01 Time 15:13 Sent To  
Notes
2006-09-01 00:00:00HISTORIC APPROVED BY GJUDGE

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-10-20 Cont ID  
Sent By adarroug Date 2006-10-20 Time 13:44 Rev Time 0.00
Received By adarroug Date 2006-10-20 Time 13:44 Sent To G
Notes
2006-10-20 13:45:24TO "G" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-09-11 Cont ID  
Sent By adarroug Date 2006-09-11 Time 14:38 Rev Time 0.00
Received By adarroug Date 2006-09-11 Time 14:38 Sent To E
Notes
2006-09-11 00:00:00TO "GEN-RES" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-10-18 Cont ID  
Sent By alange Date 2006-10-18 Time 09:29 Rev Time 0.00
Received By alange Date 2006-09-07 Time 08:24 Sent To  
Notes
2006-09-07 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-09-18 Cont ID  
Sent By tgordon Date 2006-09-18 Time 14:07 Rev Time 0.15
Received By tgordon Date 2006-09-18 Time 14:07 Sent To P
Notes
2006-09-18 00:00:00*** PROVISO ***
 1) PER 2004 FBC, FUEL GAS - POWERED
 EQUIPMENT - PERMANENTLY INSTALLED
 EQUIPMENT POWERED BY INTERNAL COMBUSTION
 ENGINES SHALL BE INSTALLED IN ACCORDANCE
 WITH MANUFACTURE'S INSTALLATION
 INSTRUCTIONS AND NFPA 37.
  
 NFPA 37 INSTALLATION & USE OF STATIONARY
 COMBUSTION ENGINES & GAS TURBINES:
 4.1.4ENGINES (GENERATORS) LOCATED
 OUTDOORS SHALL BE MINIMUM OF 5 FT FROM
 OPENINGS IN WALLS & AT LEAST 5 FT FROM
 STRUCTURES HAVING COMBUSTIBLE WALLS.A
 MINIMUM CLEARANCE IS NOT REQUIRED WHEN
 (1) THE ADJACENT WALL HAS A MINIMUM FIRE
 RESISTANCE RATING OF 1 HOUR OR (2) THE
 WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF
 NON-COMBUSTIBLE MATERIALS, AND IT HAS
 BEEN DEMONSTRATED THAT A FIRE WITHIN THE
 ENCLOSURE WILL NOT IGNITE COMBUSTIBLE
 MATERIALS OUTSIDE THE ENCLOSURE.
 INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS
 SHOULD NOT TERMINATE UNDER STRUCTURES OR
 WHERE THE EXHAUST MIGHT BE DRAWN INTO
 THE VENTILATION INTAKES.
  
 2004 FMC 804.3.5 #3, WHERE THE
 TERMINATION IS LOCATED BELOW AN ADJACENT
 ROOF STRUCTURE, THE TERMINATION POINT
 SHALL BE LOCATED AT LEAST 3 FT FROM THE
 ROOF STRUCTURE.
  
 PLEASE NOTE, WHILE ZONING ALLOWS
 MECHANICAL EQUIPMENT TO ENCROACH 4 FT
 INTO THE REQUIRED SETBACK, GENERATORS
 SHALL MAINTAIN THE REQUIRED ABOVE
 MENTIONED CLEARANCES TO THE ADJACENT
 PROPERTY STRUCTURES, I.E. FENCE,
 BUILDING, WINDOWS, DOORS, OR OPENINGS.
  
 FOLLOW MANUFACTURE'S RECOMMENDED
 CLEARANCES AROUND EQUIPMENT FOR
 SERVICING,AND PROVIDE MANUFACTURE'S
 INSTALLATION INSTRUCTIONS AT THE JOBSITE
 FOR THE FIELD INSPECTOR.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop Z ZONING
Rev No 1 Status P Date 2006-09-09 Cont ID  
Sent By mmclean Date 2006-09-09 Time 12:02 Rev Time 0.00
Received By mmclean Date 2006-09-09 Time 12:02 Sent To I
Notes
2006-09-09 00:00:00THE PROPOSED GENERATOR SHALL NOT BE
 CLOSER THAN 8FT FROM REAR PROPERTY LINE.