Plan Review Stops For Permit 06082241 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2008-04-19 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-04-19 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-04-19 |
Time |
10:24 |
Sent To |
PC |
|
Notes |
2008-04-19 10:25:45 | | | | | PASSED | | | | REVISION ADDITION OF 4 DOORS TO SCOPE OF WORK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2008-03-19 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-03-19 |
Time |
18:24 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-03-19 |
Time |
18:24 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2008-03-11 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2008-03-11 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2008-03-11 |
Time |
15:37 |
Sent To |
PC |
|
Notes |
2008-03-11 16:21:44 | | | | | DENIED | | | | 1)PROVIDE WIND DESIGN DATA ON DRAWINGS PER 1603.1.4 | | FBC PLEASE NOTE THAT WIND EXPOSURE CATEGORY WAS NOT ON | | ORIGINAL SHEET A-1 AND SCOPE WAS FOR INTERIOR WORK | | ONLY | | | | 2)PROVIDE STRUCTURAL DETAILS FOR ANY REPAIRS TO | | WINDOW OPENINGS AND INFILL OF OPENINGS WHERE WINDOWS | | ARE REMOVED | | | | 3)PROVIDE CORRECT COMPLIANCE REPORT FOR THE STATEWIDE | | PRODUCT APPROVAL (SEE 2ND PAGE OF PRODUCT APPROVAL) | | MIAMI-DADE #05-0930.03 AND DRAWING 05-TRA-0003 THAT CAN | | BE DOWNLOADED FROM THE LINK ON PAGE 2 | | | | 4)EXTERIOR ELEVATION SHEETS ARE REQUIRED TO BE | | STAMPED BY THE HISTORIC PRESERVATION DIVISION | | | | 5)INCREASE VALUE ON ORIGINAL PERMIT FOR NEW SCOPE OF | | WORK TO INCLUDE ALL NEW MATERIAL, REPAIRS AND WINDOW | | INSTALLATION | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-05-13 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-05-13 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-05-13 |
Time |
14:32 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-03-26 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-03-26 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-03-26 |
Time |
17:56 |
Sent To |
PC |
|
Notes |
2007-03-26 18:02:01 | | | DENIED | | | | 1) IN AN EXISTING BUILDING A DESIGN PROFFESIONAL MUST | | ELECT THE LEVEL OF ALTERATION PER 301.5 OF EXISTING | | BUILDING CODE AND ALONG WITH THE TYPE OF CONSTRUCTION | | STATE ON THE DRAWINGS | | | | 2) THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | PER 108.3 FBC*. THE VALUE WAS NOT UPDATED FROM PREVIOUS | | REVIEW AND HAS NOW BEEN CHANGED TO REFLECT CORRECT | | VALUE AND ADDITIONAL FEES ARE DUE | | | | 3)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-10-11 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-10-11 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-10-11 |
Time |
09:06 |
Sent To |
|
|
Notes |
2006-10-11 09:19:21 | DENIED | | | | 1.PERMIT VALUATION:VALUE ON PERMIT SHOULD REFLECT | | ALL MATERIALS AND LABOR FOR THE PROJECT. IFTHE | | PERMIT VALUATION IS NOT CORRECTED THE VALUE WILL BE | | ADJUSTED ACCORDING TO MARSHALL AND SWIFTS ESTIMATING | | GUIDE. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-01-04 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-01-04 |
Time |
10:29 |
Rev Time |
1.00 |
Received By |
btrobaug |
Date |
2007-01-04 |
Time |
10:21 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-09-19 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-09-19 |
Time |
08:07 |
Rev Time |
1.00 |
Received By |
btrobaug |
Date |
2006-09-18 |
Time |
17:38 |
Sent To |
P |
|
Notes |
2006-09-18 00:00:00 | | | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THE 3/0 SERVICE CONDUCTORS ARE NOT | | LARGE ENOUGH FOR THE CALCULATED LOAD. | | SEE 310.15(B)(6). | | | | 2} THERE IS NO WATER HEATER LISTED IN | | THE HOUSE PANEL, YET THE REQUIRED | | LAUNDRY CIRCUIT (WASHER) IS LISTED IN | | THAT PANEL. PLEASE VERIFY THERE IS NO | | HOT WATER TO BE SUPPLIED TO THE WASHER. | | THE GARAGE PLUMBING DOES NOT SEEM TO BE | | ON THE PLUMBING RISR. | | | | 3} THE BREAKFAST ROOM LISTED ON THE | | PANEL SCHEDULES,PANELS 1, 2, AND 3 MUST | | BE ON A 20AMP CIRCUIT PER 210.52(B)(1). | | | | 4} THE BATH CIRCUITS SHALL BE 20 AMP. | | 210.11(C)(3). | | | | 5} PLEASE SEE ALL KITCHEN RECEPTACLES | | MUST COMPLY WITH 210.52(B). TWO | | RECEPTACLES IN UNIT #1, ONE LISTED ON | | C13 AND THE OTHER NOT LISTED BUT ON WITH | | A LIVING ROOM OUTLET, DO NOT COMPLY. | | | | 6} THE BREAKFAST ROOM CIRCUIT IN UNIT #2 | | MAY NOT FEED THE LIVING ROOM OUTLETS. | | 210.52(B)(2). | | | | 7} UNIT #3 KITCHEN NEEDS A RECEPTACLE | | ADDED BY THE RANGE TO COMPLY WITH | | 210.52(C)(1). | | | | 8} THE SMOKE DETECTOR LOCATION OUTSIDE | | THE BEDROOMS DO NOT COMPLY WITH THE | | "IMMEDIATE VICINITY" INTENT OF R313.1.1 | | 2. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2008-04-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-04-14 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-04-14 |
Time |
16:52 |
Sent To |
B |
|
Notes |
2008-04-14 16:52:59 | TO "AMORSE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2008-03-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-14 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-14 |
Time |
10:20 |
Sent To |
B |
|
Notes |
2008-03-14 10:21:02 | TO "AMORSE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2008-02-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-02-29 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-02-29 |
Time |
16:14 |
Sent To |
B |
|
Notes |
2008-02-29 16:15:18 | TO "AMORSE" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-04-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-24 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-24 |
Time |
11:27 |
Sent To |
P |
|
Notes |
2007-04-24 11:27:41 | TO "P" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-12-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-29 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-29 |
Time |
08:36 |
Sent To |
E |
|
Notes |
2006-12-29 08:37:21 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-10-11 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-10-11 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-09-06 |
Time |
16:50 |
Sent To |
|
|
Notes |
2006-09-06 00:00:00 | TO "E" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2007-01-09 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-01-09 |
Time |
13:43 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-01-09 |
Time |
13:43 |
Sent To |
B |
|
Notes |
2007-01-09 13:44:38 | NO MECHANICAL PLANS SUBMITTED, AND NO | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | THIS TIME. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-05-02 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-05-02 |
Time |
16:38 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2007-05-02 |
Time |
16:37 |
Sent To |
B |
|
Notes |
2007-05-02 16:40:39 | ****************PROVISO**************** | | PER FBC-2001 PLUMBING, SECTION 1002.3 "S" TRAPS ARE | | PROHIBITED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2007-01-09 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-01-09 |
Time |
10:05 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2007-01-09 |
Time |
10:05 |
Sent To |
M |
|
Notes |
2007-01-09 11:22:34 | DENIED 2ND TIME | | REFERENCE: FBC-2001 PLUMBING | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | PLAN REVIEW ON THE RESUBMITTED SHEET P2 SANITARY RISER | | DIAGRAM TO MEET CODE COMPLIANCE: | | | | 1.SHEET P2 FIRST FLOOR UNIT #1: A} VENT REQUIRED FOR | | DOUBLE BOWL SINK W/DISHWASHER PER FBC-2001 PLUMBING, | | SEC. 901.2.1 B} PLEASE INDICATE DOUBLE BOWL SINK | | W/DISHWASHER AND ADD DRAIN FOR DISHWASHER PER FBC-2001 | | SEC. 409.3.1. | | | | 2.SHEET P2 FIRST FLOOR UNIT #2: A} VENT REQUIRED FOR | | DOUBLE BOWL SINK W/DISHWASHER PER FBC-2001 PLUMBING, | | SEC. 901.2.1. B} PLEASE INDICATE DOUBLE BOWL SINK | | W/DISHWASHER AND ADD DRAIN FOR DISHWASHER PER FBC-2001 | | PLUMBING SEC. 409.3.1. | | | | 3. SHEET P2 SECOND FLOOR UNIT #3: A} VENT REQUIRED FOR | | BATHROOM GROUP PER FBC-2001 PLUMBING SEC. 909.1. B} | | PLEASE INDICATE DOUBLE BOWL SINK W/ DISHWASHER AND ADD | | DRAIN FOR DISHWASHER PER FBC-2001 PLUMBING SEC. | | 409.3.1. | | | | 4. SHEET P2 GARAGE WASHING MACHINE: A} PLEASE INDICATE | | STANDPIPE FOR WASHING MACHINE DRAIN PER FBC-2001 | | PLUMBING, SEC. 802.4. B} PLEASE INDICATE CLEANOUT FOR | | WASHING MACHINE AT FOUR FEET ABOVE FINNISH FLOOR (4' | | A.F.F.) PER FBC-2001 PLUMBING SEC. 708.10. | | | | **********IMPORTANT INFORMATION | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-10-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-01-04 |
Time |
10:37 |
Rev Time |
0.55 |
Received By |
mperson |
Date |
2006-10-02 |
Time |
15:01 |
Sent To |
B |
|
Notes |
2006-10-02 00:00:00 | ******DENIED****** | | REFERENCE: FBC-2004 PLUMBING | | | | THE FOLLOWING INFORMATION IS REQUIRED | | FOR PLUMBING PLAN REVIEW. PLEASE | | REFERENCE THE CORRECTED DRAWINGS IN RED | | INK FOR RESUBMITTAL: | | | | 1. PLEASE CHANGE THE WORDING ON SHEET | | P-1, COPPER PIPE SCH. 40 TO READ, COPPER | | PIPE TYPE "L" FOR THE RESUBMITTAL. | | 2. PER FBC-2004 SEC. 608.15.4.2 HOSE | | CONNECTIONS: PLEASE CHANGE THE WORDING | | ON SHEET P-1, PLUMBING NOTE #4 TO READ | | VACUUM BREAKERS INSTEAD OF BACKFLOW | | PREVENTERS. | | 3. THE S.V.= STUDOR VENTS (AUTOMATIC AIR | | VENTS) INDICATED ON SHEET P-2 ARE NOT | | REQUIRED BECAUSE THE SANITARY ISOMETRIC | | PLUMBING RISER DIAGRAM INDICATES V.T.R. | | (VENTS THROUGH ROOF). PLEASE DELETE THE | | S.V. FOR THE RESUBMITTAL. | | 4. PER FBC-2004, PLUMBING, SECTION 909.1 | | WET VENT PERMITTED: ONLY THE FIXTURES | | WITHIN THE BATHROOM GROUPS SHALL CONNECT | | TO THE WET-VENTED HORIZONTAL BRANCH | | DRAIN. ANY ADDITIONAL FIXTURES SHALL | | DISCHARGE DOWNSTREAM OF THE WET VENT. | | NOTE: THE KITCHEN SINK INDICATED ON | | SHEET P-2 SANITARY RISER DIAGRAM FOR | | UNIT #2 IS PIPED WRONG, PLEASE REFERENCE | | THE CORRECTED DRAWING IN RED INK FOR | | RESUBMITTAL. | | 5. PER FBC-2004 PLUMBING, SECTION 1002.1 | | A FIXTURE SHALL NOT BE DOUBLE TRAPPED. | | NOTE: THE W.C. INDICATED ON SHEET P-2 | | SANITARY RISER DIAGRAM HAS AN INTREGRAL | | TRAP THEREFORE A TRAP NEED NOT BE | | INDICATED FOR THE W.C. ON THE SANITARY | | RISER DIAGRAM. PLEASE CORRECT FOR THE | | RESUBMITTAL. | | 6. PER FBC-2004 PLUMBING TABLE 403.1 | | MINIMUM NUMBER OF REQUIRED FIXTURES: | | ONE (1) AUTOMATIC CLOTHES WASHER | | REQUIRED PER TWENTY (20) DWELLING UNITS. | | PLEASE INDICATE ON THE RESUBMITTAL THE | | AUTOMATIC CLOTHES WASHER LOCATION. | | 7. PER FBC-2004 PLUMBING, SECTION | | 901.2.1 VENTING REQUIRED: THE TUBS | | INDICATED ON SHEET P-2, UNITS #1 AND #2 | | REQUIRE VENTS. | | 8. PLEASE INDICATE ON THE RESUBMITTAL IF | | THERE IS ANY PLUMBING IN THE EXISTING | | GARAGE. IF THERE IS PLUMBING IN THE | | GARAGE PLEASE INDICATE PLUMBING ON THE | | SANITARY ISOMETRIC RISER DIAGRAM. | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN | | RESUBMITTING, PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|